Year |
Citation |
Score |
2021 |
Makowski N, Campean A, Lambrecht JM, Buckett JR, Coburn J, Hart RL, Miller ME, Montague FW, Crish T, Fu MJ, Kilgore KL, Peckham PH, Smith B. Design and Testing of Stimulation and Myoelectric Recording Modules in an Implanted Distributed Neuroprosthetic System. Ieee Transactions On Biomedical Circuits and Systems. PMID 33729949 DOI: 10.1109/TBCAS.2021.3066838 |
0.735 |
|
2020 |
Kilgore KL, Smith B, Campean A, Hart RL, Lambrecht JM, Buckett JR, Peckham PH. Powering strategies for implanted multi-function neuroprostheses for spinal cord injury. Healthcare Technology Letters. 7: 81-86. PMID 32754342 DOI: 10.1049/Htl.2019.0113 |
0.645 |
|
2020 |
Kilgore KL, Anderson KD, Peckham PH. Neuroprosthesis for individuals with spinal cord injury. Neurological Research. 1-13. PMID 32727296 DOI: 10.1080/01616412.2020.1798106 |
0.626 |
|
2019 |
Bullard AJ, Nason SR, Irwin ZT, Nu CS, Smith B, Campean A, Peckham PH, Kilgore KL, Willsey MS, Patil PG, Chestek CA. Design and testing of a 96-channel neural interface module for the Networked Neuroprosthesis system. Bioelectronic Medicine. 5: 3. PMID 32232094 DOI: 10.1186/s42234-019-0019-x |
0.643 |
|
2019 |
Heald E, Kilgore K, Hart R, Moss C, Peckham PH. Myoelectric signal from below the level of spinal cord injury as a command source for an implanted upper extremity neuroprosthesis - a case report. Journal of Neuroengineering and Rehabilitation. 16: 100. PMID 31375143 DOI: 10.1186/S12984-019-0571-3 |
0.751 |
|
2018 |
Kilgore KL, Bryden A, Keith MW, Hoyen HA, Hart RL, Nemunaitis GA, Peckham PH. Evolution of Neuroprosthetic Approaches to Restoration of Upper Extremity Function in Spinal Cord Injury. Topics in Spinal Cord Injury Rehabilitation. 24: 252-264. PMID 29997428 DOI: 10.1310/Sci2403-252 |
0.688 |
|
2017 |
Heald E, Hart R, Kilgore K, Peckham PH. Characterization of Volitional Electromyographic Signals in the Lower Extremity After Motor Complete Spinal Cord Injury. Neurorehabilitation and Neural Repair. 1545968317704904. PMID 28443786 DOI: 10.1177/1545968317704904 |
0.609 |
|
2017 |
Ajiboye AB, Willett FR, Young DR, Memberg WD, Murphy BA, Miller JP, Walter BL, Sweet JA, Hoyen HA, Keith MW, Peckham PH, Simeral JD, Donoghue JP, Hochberg LR, Kirsch RF. Restoration of reaching and grasping movements through brain-controlled muscle stimulation in a person with tetraplegia: a proof-of-concept demonstration. Lancet (London, England). PMID 28363483 DOI: 10.1016/S0140-6736(17)30601-3 |
0.467 |
|
2016 |
Ilfeld BM, Gabriel RA, Saulino MF, Chae J, Peckham PH, Grant SA, Gilmore CA, Donohue MC, deBock MG, Wongsarnpigoon A, Boggs JW. Infection Rates of Electrical Leads Used for Percutaneous Neurostimulation of the Peripheral Nervous System. Pain Practice : the Official Journal of World Institute of Pain. PMID 27676323 DOI: 10.1111/Papr.12523 |
0.318 |
|
2013 |
Ommaya AK, Adams KM, Allman RM, Collins EG, Cooper RA, Dixon CE, Fishman PS, Henry JA, Kardon R, Kerns RD, Kupersmith J, Lo A, Macko R, McArdle R, McGlinchey RE, ... ... Peckham PH, et al. Guest editorial: Opportunities in rehabilitation research. Journal of Rehabilitation Research and Development. 50: vii-xxxii. PMID 24203548 DOI: 10.1682/Jrrd.2012.09.0167 |
0.328 |
|
2013 |
Peckham PH, Kilgore KL. Challenges and opportunities in restoring function after paralysis. Ieee Transactions On Bio-Medical Engineering. 60: 602-9. PMID 23481680 DOI: 10.1109/Tbme.2013.2245128 |
0.62 |
|
2011 |
Moss CW, Kilgore KL, Peckham PH. Training to improve volitional muscle activity in clinically paralyzed muscles for neuroprosthesis control. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2011: 5794-7. PMID 22255657 DOI: 10.1109/IEMBS.2011.6091434 |
0.742 |
|
2011 |
Moss CW, Kilgore KL, Peckham PH. A novel command signal for motor neuroprosthetic control. Neurorehabilitation and Neural Repair. 25: 847-54. PMID 21693772 DOI: 10.1177/1545968311410067 |
0.77 |
|
2011 |
Hart RL, Bhadra N, Montague FW, Kilgore KL, Peckham PH. Design and testing of an advanced implantable neuroprosthesis with myoelectric control. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 19: 45-53. PMID 20876029 DOI: 10.1109/Tnsre.2010.2079952 |
0.801 |
|
2009 |
Kilgore KL, Peckham P, Keith MW. Twenty year experience with implanted neuroprostheses. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2009: 7212-5. PMID 19965280 DOI: 10.1109/IEMBS.2009.5335272 |
0.614 |
|
2009 |
Wheeler CA, Peckham PH. Wireless wearable controller for upper-limb neuroprosthesis. Journal of Rehabilitation Research and Development. 46: 243-56. PMID 19533538 DOI: 10.1682/Jrrd.2008.03.0037 |
0.504 |
|
2009 |
Pancrazio JJ, Peckham PH. Neuroprosthetic devices: how far are we from recovering movement in paralyzed patients? Expert Review of Neurotherapeutics. 9: 427-30. PMID 19344294 DOI: 10.1586/Ern.09.12 |
0.445 |
|
2009 |
Kilgore KL, Peckham PH, Keith MW. Twenty year experience with implanted neuroprostheses Proceedings of the 31st Annual International Conference of the Ieee Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, Embc 2009. 7212-7215. DOI: 10.1109/IEMBS.2009.5335272 |
0.554 |
|
2009 |
Peckham PH, Ackermann DM. Implantable Neural Stimulators Neuromodulation. 215-228. DOI: 10.1016/B978-0-12-374248-3.00019-7 |
0.395 |
|
2008 |
Kilgore KL, Hoyen HA, Bryden AM, Hart RL, Keith MW, Peckham PH. An implanted upper-extremity neuroprosthesis using myoelectric control. The Journal of Hand Surgery. 33: 539-50. PMID 18406958 DOI: 10.1016/J.Jhsa.2008.01.007 |
0.723 |
|
2008 |
Ackermann DM, Smith B, Wang XF, Kilgore KL, Peckham PH. Designing the optical interface of a transcutaneous optical telemetry link. Ieee Transactions On Bio-Medical Engineering. 55: 1365-73. PMID 18390327 DOI: 10.1109/Tbme.2007.913411 |
0.568 |
|
2008 |
Bryden AM, Kilgore KL, Keith MW, Peckham PH. Assessing activity of daily living performance after implantation of an upper extremity neuroprosthesis Topics in Spinal Cord Injury Rehabilitation. 13: 37-53. DOI: 10.1310/Sci1304-37 |
0.626 |
|
2006 |
Ackermann DM, Smith B, Kilgore KL, Peckham PH. Design of a high speed transcutaneous optical telemetry link. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 2932-5. PMID 17946536 DOI: 10.1109/IEMBS.2006.260398 |
0.536 |
|
2006 |
Kilgore KL, Hart RL, Montague FW, Bryden AM, Keith MW, Hoyen HA, Sams CJ, Peckham PH. An implanted myoelectrically-controlled neuroprosthesis for upper extremity function in spinal cord injury. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 1630-3. PMID 17946056 DOI: 10.1109/IEMBS.2006.259939 |
0.702 |
|
2005 |
Peckham PH, Knutson JS. Functional electrical stimulation for neuromuscular applications. Annual Review of Biomedical Engineering. 7: 327-60. PMID 16004574 DOI: 10.1146/Annurev.Bioeng.6.040803.140103 |
0.732 |
|
2005 |
Bryden AM, Kilgore KL, Kirsch RF, Memberg WD, Peckham PH, Keith MW. An implanted neuroprosthesis for high tetraplegia Topics in Spinal Cord Injury Rehabilitation. 10: 38-52. DOI: 10.1310/G9T5-Cck9-Y0Wt-4714 |
0.668 |
|
2005 |
Smith B, Crish TJ, Buckett JR, Kilgore KL, Peckham PH. Development of an implantable networked neuroprosthesis 2nd International Ieee Embs Conference On Neural Engineering. 2005: 454-457. DOI: 10.1109/CNE.2005.1419657 |
0.542 |
|
2005 |
Kilgore KL, Peckham PH, Montague FW, Hart RL, Bryden AM, Keith MW, Hoyen H, Bhadra N. An implanted upper extremity neuroprosthesis utilizing myoelectric control 2nd International Ieee Embs Conference On Neural Engineering. 2005: 368-371. DOI: 10.1109/CNE.2005.1419634 |
0.791 |
|
2004 |
Knutson JS, Hoyen HA, Kilgore KL, Peckham PH. Simulated neuroprosthesis state activation and hand-position control using myoelectric signals from wrist muscles. Journal of Rehabilitation Research and Development. 41: 461-72. PMID 15543464 DOI: 10.1682/Jrrd.2003.04.0053 |
0.776 |
|
2004 |
Peckham PH, Gorman PH. Functional electrical stimulation in the 21st century Topics in Spinal Cord Injury Rehabilitation. 10: 126-150. DOI: 10.1310/Ppjq-Cm9N-P80M-Dedq |
0.447 |
|
2003 |
Kilgore KL, Peckham PH, Keith MW, Montague FW, Hart RL, Gazdik MM, Bryden AM, Snyder SA, Stage TG. Durability of implanted electrodes and leads in an upper-limb neuroprosthesis. Journal of Rehabilitation Research and Development. 40: 457-68. PMID 15077658 DOI: 10.1682/Jrrd.2003.11.0457 |
0.636 |
|
2003 |
Wuolle KS, Bryden AM, Peckham PH, Murray PK, Keith M. Satisfaction with upper-extremity surgery in individuals with tetraplegia. Archives of Physical Medicine and Rehabilitation. 84: 1145-9. PMID 12917852 DOI: 10.1016/S0003-9993(03)00292-2 |
0.311 |
|
2002 |
Knutson JS, Naples GG, Peckham PH, Keith MW. Electrode fracture rates and occurrences of infection and granuloma associated with percutaneous intramuscular electrodes in upper-limb functional electrical stimulation applications. Journal of Rehabilitation Research and Development. 39: 671-83. PMID 17943669 |
0.67 |
|
2002 |
Bhadra N, Peckham PH, Keith MW, Kilgore KL, Montague F, Gazdik M, Stage T. Implementation of an implantable joint-angle transducer. Journal of Rehabilitation Research and Development. 39: 411-22. PMID 12173761 |
0.8 |
|
2002 |
Peckham PH, Kilgore KL, Keith MW, Bryden AM, Bhadra N, Montague FW. An advanced neuroprosthesis for restoration of hand and upper arm control using an implantable controller. The Journal of Hand Surgery. 27: 265-76. PMID 11901386 DOI: 10.1053/Jhsu.2002.30919 |
0.813 |
|
2002 |
Knutson JS, Peckham PH. Feasibility of using myoelectric signals from wrist muscles for control of a hand grasp neuroprosthesis Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 3: 2562-2563. |
0.694 |
|
2001 |
Grill WM, McDonald JW, Peckham PH, Heetderks W, Kocsis J, Weinrich M. At the interface: convergence of neural regeneration and neural prostheses for restoration of function. Journal of Rehabilitation Research and Development. 38: 633-9. PMID 11767971 |
0.44 |
|
2001 |
Peckham PH, Keith MW, Kilgore KL, Grill JH, Wuolle KS, Thrope GB, Gorman P, Hobby J, Mulcahey MJ, Carroll S, Hentz VR, Wiegner A. Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: a multicenter study. Archives of Physical Medicine and Rehabilitation. 82: 1380-8. PMID 11588741 DOI: 10.1053/Apmr.2001.25910 |
0.668 |
|
2001 |
Bhadra N, Kilgore KL, Peckham PH. Implanted stimulators for restoration of function in spinal cord injury. Medical Engineering & Physics. 23: 19-28. PMID 11344004 DOI: 10.1016/S1350-4533(01)00012-1 |
0.81 |
|
2000 |
Creasey GH, Kilgore KL, Brown-Triolo DL, Dahlberg JE, Peckham PH, Keith MW. Reduction of costs of disability using neuroprostheses. Assistive Technology : the Official Journal of Resna. 12: 67-75. PMID 11067579 DOI: 10.1080/10400435.2000.10132010 |
0.545 |
|
2000 |
Lauer RT, Peckham PH, Kilgore KL, Heetderks WJ. Applications of cortical signals to neuroprosthetic control: a critical review. Ieee Transactions On Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 8: 205-8. PMID 10896188 DOI: 10.1109/86.847817 |
0.716 |
|
1999 |
Lauer RT, Peckham PH, Kilgore KL. EEG-based control of a hand grasp neuroprosthesis. Neuroreport. 10: 1767-71. PMID 10501572 |
0.741 |
|
1999 |
Johnson MW, Peckham PH, Bhadra N, Kilgore KL, Gazdik MM, Keith MW, Strojnik P. Implantable transducer for two-degree of freedom joint angle sensing. Ieee Transactions On Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 7: 349-59. PMID 10498380 DOI: 10.1109/86.788471 |
0.792 |
|
1999 |
Bhadra N, Keith MW, Peckham PH. Variations in innervation of the flexor digitorum profundus muscle. The Journal of Hand Surgery. 24: 700-3. PMID 10447160 DOI: 10.1053/Jhsu.1999.0700 |
0.738 |
|
1999 |
Lauer RT, Kilgore KL, Peckham PH, Bhadra N, Keith MW. The function of the finger intrinsic muscles in response to electrical stimulation. Ieee Transactions On Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 7: 19-26. PMID 10188604 DOI: 10.1109/86.750547 |
0.795 |
|
1999 |
Stroh Wuolle K, Van Doren CL, Bryden AM, Peckham PH, Keith MW, Kilgore KL, Grill JH. Satisfaction with and usage of a hand neuroprosthesis. Archives of Physical Medicine and Rehabilitation. 80: 206-13. PMID 10025499 DOI: 10.1016/S0003-9993(99)90123-5 |
0.659 |
|
1999 |
Peckham PH, Keith MW, Kilgore KL. Restoration of upper extremity function in tetraplegia Topics in Spinal Cord Injury Rehabilitation. 5: 33-43. DOI: 10.1310/Uckb-Nvgc-G71T-Hjew |
0.68 |
|
1999 |
Peckham PH. Principles of electrical stimulation Topics in Spinal Cord Injury Rehabilitation. 5: 1-5. DOI: 10.1310/981Y-E0Ud-Jkpv-Gxpc |
0.38 |
|
1998 |
Kilgore KL, Lauer RT, Peckham PH. A transducer for the measurement of finger joint moments. Ieee Transactions On Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 6: 424-9. PMID 9865890 DOI: 10.1109/86.736157 |
0.709 |
|
1998 |
Hart RL, Kilgore KL, Peckham PH. A comparison between control methods for implanted FES hand-grasp systems. Ieee Transactions On Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 6: 208-18. PMID 9631329 DOI: 10.1109/86.681187 |
0.602 |
|
1998 |
Grill JH, Peckham PH. Functional neuromuscular stimulation for combined control of elbow extension and hand grasp in C5 and C6 quadriplegics. Ieee Transactions On Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 6: 190-9. PMID 9631327 DOI: 10.1109/86.681185 |
0.361 |
|
1998 |
Smith B, Tang Z, Johnson MW, Pourmehdi S, Gazdik MM, Buckett JR, Peckham PH. An externally powered, multichannel, implantable stimulator-telemeter for control of paralyzed muscle. Ieee Transactions On Bio-Medical Engineering. 45: 463-75. PMID 9556963 DOI: 10.1109/10.664202 |
0.36 |
|
1997 |
Bhadra N, Peckham PH. Peripheral nerve stimulation for restoration of motor function. Journal of Clinical Neurophysiology : Official Publication of the American Electroencephalographic Society. 14: 378-93. PMID 9415385 DOI: 10.1097/00004691-199709000-00004 |
0.761 |
|
1997 |
Scott TR, Bhadra N, Kilgore KL, Peckham PH. The monitoring of tendon tension with an implantable intratendon probe and its use in the control of neuroprostheses. Ieee Transactions On Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 5: 233-5. PMID 9184908 DOI: 10.1109/86.593303 |
0.812 |
|
1997 |
Kilgore KL, Peckham PH, Keith MW, Thrope GB, Wuolle KS, Bryden AM, Hart RL. An implanted upper-extremity neuroprosthesis. Follow-up of five patients. The Journal of Bone and Joint Surgery. American Volume. 79: 533-41. PMID 9111397 |
0.656 |
|
1996 |
Scott TR, Peckham PH, Kilgore KL. Tri-state myoelectric control of bilateral upper extremity neuroprostheses for tetraplegic individuals. Ieee Transactions On Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 4: 251-63. PMID 8973951 DOI: 10.1109/86.547925 |
0.629 |
|
1996 |
Keith MW, Kilgore KL, Peckham PH, Wuolle KS, Creasey G, Lemay M. Tendon transfers and functional electrical stimulation for restoration of hand function in spinal cord injury. The Journal of Hand Surgery. 21: 89-99. PMID 8775202 DOI: 10.1016/S0363-5023(96)80160-2 |
0.688 |
|
1996 |
Creasey G, Elefteriades J, DiMarco A, Talonen P, Bijak M, Girsch W, Kantor C, Peckham PH. Electrical stimulation to restore respiration Journal of Rehabilitation Research and Development. 33: 123-132. PMID 8724168 |
0.324 |
|
1994 |
Tang Z, Peckham PH. Multichannel implantable stimulation and telemetry system for neuromuscular control Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 16: 442-443. |
0.332 |
|
1994 |
Kilgore KL, Lauer RT, Peckham PH. Transducer for measurement of finger joint torques Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 16: 938-939. |
0.617 |
|
1993 |
Kilgore KL, Peckham PH. Grasp synthesis for upper-extremity FNS. Part 2. Evaluation of the influence of electrode recruitment properties. Medical & Biological Engineering & Computing. 31: 615-22. PMID 8145588 DOI: 10.1007/BF02441810 |
0.604 |
|
1993 |
Kilgore KL, Peckham PH. Grasp synthesis for upper-extremity FNS. Part 1. Automated method for synthesising the stimulus map. Medical & Biological Engineering & Computing. 31: 607-14. PMID 8145587 DOI: 10.1007/BF02441809 |
0.569 |
|
1992 |
Betz RR, Mulcahey MJ, Smith BT, Triolo RJ, Weiss AA, Moynahan M, Keith MW, Peckham PH. Bipolar latissimus dorsi transposition and functional neuromuscular stimulation to restore elbow flexion in an individual with C4 quadriplegia and C5 denervation. The Journal of the American Paraplegia Society. 15: 220-8. PMID 1431869 DOI: 10.1080/01952307.1992.11761522 |
0.471 |
|
1992 |
Peckham PH. Opportunities and Challenges for the Clinical Utilization of Functional Electrical Stimulation Assistive Technology. 4: 46-48. DOI: 10.1080/10400435.1992.10132192 |
0.346 |
|
1991 |
Gorman PH, Peckham PH. Upper Extremity Functional Neuromuscular Stimulation Neurorehabilitation and Neural Repair. 5: 3-11. DOI: 10.1177/136140969100500102 |
0.474 |
|
1991 |
Peckham PH, Keith MW, Crago PE. B. Upper limb applications [137] Functional neuromuscular systems (FNS) for upper extremity control Journal of Rehabilitation Research and Development. 28: 113-114. |
0.572 |
|
1990 |
Kilgore KL, Peckham PH, Keith MW, Thrope GB. Electrode characterization for functional application to upper extremity FNS. Ieee Transactions On Bio-Medical Engineering. 37: 12-21. PMID 2154398 DOI: 10.1109/10.43606 |
0.633 |
|
1989 |
Miller LJ, Peckham PH, Keith MW. Elbow extension in the C5 quadriplegic using functional neuromuscular stimulation. Ieee Transactions On Bio-Medical Engineering. 36: 771-80. PMID 2787285 DOI: 10.1109/10.32110 |
0.363 |
|
1989 |
Kilgore KL, Peckham PH, Thrope GB, Keith MW, Gallaher-Stone KA. Synthesis of hand grasp using functional neuromuscular stimulation. Ieee Transactions On Bio-Medical Engineering. 36: 761-70. PMID 2787284 DOI: 10.1109/10.32109 |
0.617 |
|
1989 |
Keith MW, Peckham PH, Thrope GB, Stroh KC, Smith B, Buckett JR, Kilgore KL, Jatich JW. Implantable functional neuromuscular stimulation in the tetraplegic hand. The Journal of Hand Surgery. 14: 524-30. PMID 2786897 DOI: 10.1016/S0363-5023(89)80017-6 |
0.675 |
|
1989 |
Kilgore KL, Keith MW, Peckham PH. Surgical alterations and functional neuromuscular stimulation for enhancement of hand function in spinal cord injury Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 11: 1496-1497. |
0.591 |
|
1988 |
Freehafer AA, Peckham PH, Keith MW, Mendelson LS. The brachioradialis: anatomy, properties, and value for tendon transfer in the tetraplegic. The Journal of Hand Surgery. 13: 99-104. PMID 3351238 DOI: 10.1016/0363-5023(88)90210-9 |
0.375 |
|
1988 |
Mendelson LS, Peckham PH, Freehafer AA, Keith MW. Intraoperative assessment of wrist extensor muscle force. The Journal of Hand Surgery. 13: 832-6. PMID 3225409 DOI: 10.1016/0363-5023(88)90256-0 |
0.447 |
|
1988 |
Keith MW, Peckham PH, Thrope GB, Buckett JR, Stroh KC, Menger V. Functional neuromuscular stimulation neuroprostheses for the tetraplegic hand. Clinical Orthopaedics and Related Research. 25-33. PMID 3042233 DOI: 10.1097/00003086-198808000-00005 |
0.466 |
|
1987 |
Smith B, Peckham PH, Keith MW, Roscoe DD. An externally powered, multichannel, implantable stimulator for versatile control of paralyzed muscle. Ieee Transactions On Bio-Medical Engineering. 34: 499-508. PMID 3610200 DOI: 10.1109/Tbme.1987.325979 |
0.41 |
|
1987 |
Peckham PH. Functional electrical stimulation: current status and future prospects of applications to the neuromuscular system in spinal cord injury. Paraplegia. 25: 279-88. PMID 3496576 DOI: 10.1038/Sc.1987.52 |
0.402 |
|
1987 |
Crago PE, Mortimer JT, Peckham PH, Chizeck HJ. Authors’ Reply Ieee Transactions On Biomedical Engineering. 261-263. DOI: 10.1109/TBME.1987.325958 |
0.647 |
|
1987 |
Hart RL, Peckham PH, Crago PE. EVALUATION OF A THREE-DIMENSIONAL TRACKING SYSTEM TO MONITOR HAND KINEMATICS. Ieee/Engineering in Medicine and Biology Society Annual Conference. 353-354. |
0.514 |
|
1986 |
Lacey SH, Wilber RG, Peckham PH, Freehafer AA. The posterior deltoid to triceps transfer: a clinical and biomechanical assessment. The Journal of Hand Surgery. 11: 542-7. PMID 3722768 DOI: 10.1016/S0363-5023(86)80195-2 |
0.411 |
|
1986 |
Kilgore KL, Peckham PH, Keith MW, Thrope GB. CHARACTERIZATION OF A LATERAL PREHENSION-RELEASE GRASP USING FUNCTIONAL NEUROMUSCULAR STIMULATION. . 451-453. |
0.564 |
|
1986 |
Crago PE, Owens NE, Tills K, Thrope GB, Peckham PH, Keith MW. OPEN AND CLOSED-LOOP CONTROL OF FNS HAND GRASP. Ieee/Engineering in Medicine and Biology Society Annual Conference. 683-686. |
0.563 |
|
1985 |
Kelly CM, Freehafer AA, Peckham PH, Stroh K. Postoperative results of opponensplasty and flexor tendon transfer in patients with spinal cord injuries. The Journal of Hand Surgery. 10: 890-4. PMID 4078275 DOI: 10.1016/S0363-5023(85)80168-4 |
0.363 |
|
1985 |
Thrope GB, Peckham PH, Crago PE. A computer-controlled multichannel stimulation system for laboratory use in functional neuromuscular stimulation. Ieee Transactions On Bio-Medical Engineering. 32: 363-70. PMID 3874146 DOI: 10.1109/Tbme.1985.325461 |
0.662 |
|
1984 |
Freehafer AA, Kelly CM, Peckham PH. Tendon transfer for the restoration of upper limb function after a cervical spinal cord injury. The Journal of Hand Surgery. 9: 887-93. PMID 6512207 DOI: 10.1016/S0363-5023(84)80073-8 |
0.383 |
|
1984 |
Peckham PH, Crago PE, Riso RR. FUNCTIONAL ACTIVATION OF THE PARALYZED EXTREMITIES. . 54-55. |
0.533 |
|
1984 |
Smith B, Braswell SD, Buckett JR, Jackson KC, Peckham PH. PORTABLE MICROPROCESSOR CONTROLLED IMPLANTABLE FUNCTIONAL NEUROMUSCULAR STIMULATION SYSTEM . 531-532. |
0.355 |
|
1983 |
Peckham PH. Restoration of Upper Extremity Function Ieee Engineering in Medicine and Biology Magazine. 2: 30-32. DOI: 10.1109/Emb-M.1983.5005951 |
0.461 |
|
1983 |
Thrope GB, Peckham PH, Crago PE, Braswell SD, Buckett JR. LINEARIZATION OF AN OPEN LOOP FUNCTIONAL NEUROMUSCULAR STIMULATION SYSTEM THROUGH A PIECEWISE LINEAR APPROXIMATION. . 66-68. |
0.565 |
|
1981 |
Peckham PH, Poon CW, Ko WH, Marsolais EB, Rosen JJ. Multichannel implantable stimulator for control of paralyzed muscle. Ieee Transactions On Bio-Medical Engineering. 28: 530-6. PMID 7275134 DOI: 10.1109/Tbme.1981.324740 |
0.458 |
|
1980 |
Crago PE, Mortimer JT, Peckham PH. Closed-loop control of force during electrical stimulation of muscle. Ieee Transactions On Bio-Medical Engineering. 27: 306-12. PMID 7390527 DOI: 10.1109/Tbme.1980.326738 |
0.761 |
|
1980 |
Peckham PH, Mortimer JT, Marsolais EB. Controlled prehension and release in the C5 quadriplegic elicited by functional electrical stimulation of the paralyzed forearm musculature. Annals of Biomedical Engineering. 8: 369-88. PMID 7294457 DOI: 10.1007/BF02363440 |
0.621 |
|
1980 |
Crago PE, Peckham PH, Thrope GB. Modulation of muscle force by recruitment during intramuscular stimulation. Ieee Transactions On Bio-Medical Engineering. 27: 679-84. PMID 6970162 DOI: 10.1109/Tbme.1980.326592 |
0.646 |
|
1980 |
Peckham PH, Marsolais EB, Mortimer JT. Restoration of key grip and release in the C6 tetraplegic patient through functional electrical stimulation. The Journal of Hand Surgery. 5: 462-9. PMID 6968764 DOI: 10.1016/S0363-5023(80)80076-1 |
0.731 |
|
1979 |
Freehafer AA, Peckham PH, Keith MW. Determination of muscle-tendon unit properties during tendon transfer. The Journal of Hand Surgery. 4: 331-9. PMID 469208 DOI: 10.1016/S0363-5023(79)80069-6 |
0.401 |
|
1976 |
Peckham PH, Mortimer JT, Marsolais EB. Alteration in the force and fatigability of skeletal muscle in quadriplegic humans following exercise induced by chronic electrical stimulation. Clinical Orthopaedics and Related Research. 326-33. PMID 1083324 |
0.632 |
|
1976 |
Peckham PH, Mortimer JT, Marsolais EB. Upper and lower motor neuron lesions in the upper extremity muscles of tetraplegics. Paraplegia. 14: 115-21. PMID 972757 DOI: 10.1038/sc.1976.19 |
0.647 |
|
1974 |
Van der Meulen JP, Peckham PH, Mortimer JT. Trophic functions of the neuron. 3. Mechanisms of neurotrophic interactions. Use and disuse of muscle. Annals of the New York Academy of Sciences. 228: 177-89. PMID 4526353 DOI: 10.1111/j.1749-6632.1974.tb20509.x |
0.592 |
|
1974 |
Crago PE, Peckham PH, Mortimer JT, Van der Meulen JP. The choice of pulse duration for chronic electrical stimulation via surface, nerve, and intramuscular electrodes. Annals of Biomedical Engineering. 2: 252-64. PMID 4499993 DOI: 10.1007/Bf02368496 |
0.734 |
|
1974 |
Peckham PH, Marsolais EB, Mortimer JT. Electrical stimulation of hand muscles in quadriplegic man Federation Proceedings. 33: 613. |
0.656 |
|
1973 |
Peckham PH, Mortimer JT, Van Der Meulen JP. Physiologic and metabolic changes in white muscle of cat following induced exercise. Brain Research. 50: 424-9. PMID 4705510 DOI: 10.1016/0006-8993(73)90745-2 |
0.57 |
|
Show low-probability matches. |