Year |
Citation |
Score |
2016 |
DiNino M, Wright RA, Winn MB, Bierer JA. Vowel and consonant confusions from spectrally manipulated stimuli designed to simulate poor cochlear implant electrode-neuron interfaces. The Journal of the Acoustical Society of America. 140: 4404. PMID 28039993 DOI: 10.1121/1.4971420 |
0.487 |
|
2016 |
Thomas Roland J, Buchman C, Eisenberg L, Henderson L, He S, Firszt J, Francis H, Dunn C, Sladen D, Arndt S, May B, Zeitler D, Niparko JK, Emmett S, Tucci D, ... ... Bierer J, et al. Proceedings of the Annual Symposium of the American Cochlear Implant Alliance. Cochlear Implants International. 1-27. PMID 27635521 DOI: 10.1080/14670100.2016.1225348 |
0.453 |
|
2016 |
Bierer JA, Litvak L. Reducing Channel Interaction Through Cochlear Implant Programming May Improve Speech Perception: Current Focusing and Channel Deactivation. Trends in Hearing. 20. PMID 27317668 DOI: 10.1177/2331216516653389 |
0.417 |
|
2016 |
Bierer JA, Spindler E, Bierer SM, Wright R. An Examination of Sources of Variability Across the Consonant-Nucleus-Consonant Test in Cochlear Implant Listeners. Trends in Hearing. 20. PMID 27194155 DOI: 10.1177/2331216516646556 |
0.321 |
|
2016 |
Cosentino S, Carlyon RP, Deeks JM, Parkinson W, Bierer JA. Rate discrimination, gap detection and ranking of temporal pitch in cochlear implant users. Journal of the Association For Research in Otolaryngology : Jaro. PMID 27101997 DOI: 10.1007/S10162-016-0569-5 |
0.469 |
|
2016 |
DeVries L, Scheperle R, Bierer JA. Assessing the Electrode-Neuron Interface with the Electrically Evoked Compound Action Potential, Electrode Position, and Behavioral Thresholds. Journal of the Association For Research in Otolaryngology : Jaro. 17: 237-52. PMID 26926152 DOI: 10.1007/S10162-016-0557-9 |
0.658 |
|
2016 |
DiNino M, Winn MB, Bierer JA. Cochlear implant listener vowel identification performance and confusion patterns with selective channel activation programs The Journal of the Acoustical Society of America. 140: 3438-3438. DOI: 10.1121/1.4971082 |
0.571 |
|
2016 |
Bierer JA, DiNino M. Within-listener comparisons of vowel confusions in pediatric, bilateral cochlear implantees The Journal of the Acoustical Society of America. 140: 3438-3438. DOI: 10.1121/1.4971081 |
0.506 |
|
2016 |
DeVries L, Bierer JA. Psychophysical tuning curves as a measure of electrode position in cochlear implant listeners The Journal of the Acoustical Society of America. 140: 3157-3157. DOI: 10.1121/1.4969910 |
0.598 |
|
2016 |
O'Brien G, DiNino M, Biesheuvel JD, Briaire JJ, Frijns JH, Bierer JA. Comparing auditory perceptual thresholds in pediatric and adult cochlear implant populations The Journal of the Acoustical Society of America. 140: 3157-3157. DOI: 10.1121/1.4969908 |
0.556 |
|
2016 |
Carlyon RP, Cosentino S, Deeks JM, Parkinson W, Bierer JA. Limitations on temporal processing by cochlear implant users The Journal of the Acoustical Society of America. 139: 2154-2154. DOI: 10.1121/1.4950373 |
0.521 |
|
2016 |
DeVries L, Scheperle R, Bierer JA. Assessing the Electrode-Neuron Interface with the Electrically Evoked Compound Action Potential, Electrode Position, and Behavioral Thresholds Jaro - Journal of the Association For Research in Otolaryngology. 1-16. DOI: 10.1007/s10162-016-0557-9 |
0.407 |
|
2015 |
Bierer JA, Bierer SM, Kreft HA, Oxenham AJ. A fast method for measuring psychophysical thresholds across the cochlear implant array. Trends in Hearing. 19. PMID 25656797 DOI: 10.1177/2331216515569792 |
0.511 |
|
2015 |
Bierer JA, Deeks JM, Billig AJ, Carlyon RP. Comparison of signal and gap-detection thresholds for focused and broad cochlear implant electrode configurations. Journal of the Association For Research in Otolaryngology : Jaro. 16: 273-84. PMID 25644786 DOI: 10.1007/S10162-015-0507-Y |
0.507 |
|
2014 |
Bierer JA, Nye AD. Comparisons between detection threshold and loudness perception for individual cochlear implant channels. Ear and Hearing. 35: 641-51. PMID 25036146 DOI: 10.1097/Aud.0000000000000058 |
0.527 |
|
2011 |
Bierer JA, Faulkner KF, Tremblay KL. Identifying cochlear implant channels with poor electrode-neuron interfaces: electrically evoked auditory brain stem responses measured with the partial tripolar configuration. Ear and Hearing. 32: 436-44. PMID 21178633 DOI: 10.1097/Aud.0B013E3181Ff33Ab |
0.642 |
|
2011 |
Bierer JA, Bierer SM, Maloff ES, Lin A. Cochlear implant channels with high thresholds degrade medial vowel perception. The Journal of the Acoustical Society of America. 129: 2656-2656. DOI: 10.1121/1.3588867 |
0.543 |
|
2010 |
Bierer JA, Bierer SM, Middlebrooks JC. Partial tripolar cochlear implant stimulation: Spread of excitation and forward masking in the inferior colliculus. Hearing Research. 270: 134-42. PMID 20727397 DOI: 10.1016/J.Heares.2010.08.006 |
0.655 |
|
2010 |
Bierer JA. Probing the electrode-neuron interface with focused cochlear implant stimulation. Trends in Amplification. 14: 84-95. PMID 20724356 DOI: 10.1177/1084713810375249 |
0.628 |
|
2010 |
Goldwyn JH, Bierer SM, Bierer JA. Modeling the electrode-neuron interface of cochlear implants: effects of neural survival, electrode placement, and the partial tripolar configuration. Hearing Research. 268: 93-104. PMID 20580801 DOI: 10.1016/J.Heares.2010.05.005 |
0.591 |
|
2010 |
Bierer JA, Faulkner KF. Identifying cochlear implant channels with poor electrode-neuron interface: partial tripolar, single-channel thresholds and psychophysical tuning curves. Ear and Hearing. 31: 247-58. PMID 20090533 DOI: 10.1097/Aud.0B013E3181C7Daf4 |
0.591 |
|
2007 |
Bierer JA. Threshold and channel interaction in cochlear implant users: evaluation of the tripolar electrode configuration. The Journal of the Acoustical Society of America. 121: 1642-53. PMID 17407901 DOI: 10.1121/1.2436712 |
0.604 |
|
2005 |
Middlebrooks JC, Bierer JA, Snyder RL. Cochlear implants: the view from the brain. Current Opinion in Neurobiology. 15: 488-93. PMID 16009544 DOI: 10.1016/J.Conb.2005.06.004 |
0.662 |
|
2004 |
Snyder RL, Bierer JA, Middlebrooks JC. Topographic spread of inferior colliculus activation in response to acoustic and intracochlear electric stimulation. Journal of the Association For Research in Otolaryngology : Jaro. 5: 305-22. PMID 15492888 DOI: 10.1007/S10162-004-4026-5 |
0.693 |
|
2004 |
Bierer JA, Middlebrooks JC. Cortical responses to cochlear implant stimulation: channel interactions. Journal of the Association For Research in Otolaryngology : Jaro. 5: 32-48. PMID 14564662 DOI: 10.1007/s10162-003-3057-7 |
0.693 |
|
2002 |
Middlebrooks JC, Bierer JA. Auditory cortical images of cochlear-implant stimuli: coding of stimulus channel and current level. Journal of Neurophysiology. 87: 493-507. PMID 11784765 DOI: 10.1152/Jn.00211.2001 |
0.719 |
|
2002 |
Bierer JA, Middlebrooks JC. Auditory cortical images of cochlear-implant stimuli: dependence on electrode configuration. Journal of Neurophysiology. 87: 478-92. PMID 11784764 DOI: 10.1152/Jn.00212.2001 |
0.678 |
|
Show low-probability matches. |