17 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2019 Javidmehr S, Maunder AM, Daneshmand M, De Zanche N. Toward Automated Manufacturing of RF Coils: Microstrip Resonators for 4.7 T Using 3D-Printed Dielectrics and Conductors Applied Magnetic Resonance. 50: 663-675. DOI: 10.1007/S00723-018-1108-9  0.344
2017 Kordzadeh A, De Zanche N. Optimal-permittivity dielectric liners for a 4.7T Transceiver Array. Magnetic Resonance Imaging. PMID 29278763 DOI: 10.1016/j.mri.2017.12.016  0.358
2014 De Zanche N, Pruessmann KP. Algebraic method to synthesize specified modal currents in ladder resonators: Application to noncircular birdcage coils. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. PMID 25393911 DOI: 10.1002/mrm.25503  0.394
2013 Yahya A, De Zanche N, Allen PS. A dual-tuned transceive resonator for (13) C{(1) H} MRS: two open coils in one. Nmr in Biomedicine. 26: 533-41. PMID 23401299 DOI: 10.1002/Nbm.2890  0.479
2013 Maunder AM, Daneshmand M, Mousavi P, Fallone BG, De Zanche N. Stray capacitance between magnetic resonance imaging coil elements: Models and application to array decoupling Ieee Transactions On Microwave Theory and Techniques. 61: 4667-4677. DOI: 10.1109/Tmtt.2013.2288236  0.311
2009 Barmet C, De Zanche N, Wilm BJ, Pruessmann KP. A transmit/receive system for magnetic field monitoring of in vivo MRI. Magnetic Resonance in Medicine. 62: 269-76. PMID 19449383 DOI: 10.1002/mrm.21996  0.329
2009 Brunner DO, De Zanche N, Fröhlich J, Paska J, Pruessmann KP. Travelling-wave nuclear magnetic resonance. Nature. 457: 994-8. PMID 19225521 DOI: 10.1038/nature07752  0.369
2009 Nordmeyer-Massner JA, De Zanche N, Pruessmann KP. Mechanically adjustable coil array for wrist MRI. Magnetic Resonance in Medicine. 61: 429-38. PMID 19161134 DOI: 10.1002/mrm.21868  0.312
2008 De Zanche N, Chhina N, Teh K, Randell C, Pruessmann KP, Wild JM. Asymmetric quadrature split birdcage coil for hyperpolarized 3He lung MRI at 1.5T. Magnetic Resonance in Medicine. 60: 431-8. PMID 18666111 DOI: 10.1002/mrm.21664  0.371
2008 De Zanche N, Barmet C, Nordmeyer-Massner JA, Pruessmann KP. NMR probes for measuring magnetic fields and field dynamics in MR systems. Magnetic Resonance in Medicine. 60: 176-86. PMID 18581363 DOI: 10.1002/mrm.21624  0.318
2008 Barmet C, De Zanche N, Pruessmann KP. Spatiotemporal magnetic field monitoring for MR. Magnetic Resonance in Medicine. 60: 187-97. PMID 18581361 DOI: 10.1002/mrm.21603  0.314
2008 De Zanche N, Massner JA, Leussler C, Pruessmann KP. Modular design of receiver coil arrays. Nmr in Biomedicine. 21: 644-54. PMID 18157799 DOI: 10.1002/nbm.1237  0.311
2006 Wiesinger F, Van de Moortele PF, Adriany G, De Zanche N, Ugurbil K, Pruessmann KP. Potential and feasibility of parallel MRI at high field. Nmr in Biomedicine. 19: 368-78. PMID 16705638 DOI: 10.1002/Nbm.1050  0.373
2005 De Zanche N, Yahya A, Vermeulen FE, Allen PS. Analytical approach to noncircular section birdcage coil design: verification with a Cassinian oval coil. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 53: 201-11. PMID 15690520 DOI: 10.1002/Mrm.20317  0.496
2002 De Zanche N, Allen PS. Sensitivity calculations and comparisons for shielded elliptical and circular birdcage coils. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 47: 364-71. PMID 11810681 DOI: 10.1002/Mrm.10039  0.44
1999 Riauka TA, De Zanche NF, Thompson R, Vermeulen FE, Capjack CE, Allen PS. A numerical approach to non-circular birdcage RF coil optimization: verification with a fourth-order coil. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 41: 1180-8. PMID 10371450 DOI: 10.1002/(Sici)1522-2594(199906)41:6<1180::Aid-Mrm14>3.0.Co;2-D  0.431
1999 De Zanche N, Allen PS. Confocally shielded elliptical RF resonators: application to in-vivo nuclear magnetic resonance Canadian Conference On Electrical and Computer Engineering. 3: 1521-1524.  0.429
Show low-probability matches.