Punit Prakash, Ph.D. - Publications

Affiliations: 
2008 University of Wisconsin, Madison, Madison, WI 

49 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2022 Motamarry A, Wolfe AM, Ramajayam KK, Pattanaik S, Benton T, Peterson Y, Faridi P, Prakash P, Twombley K, Haemmerich D. Extracorporeal Removal of Thermosensitive Liposomal Doxorubicin from Systemic Circulation after Tumor Delivery to Reduce Toxicities. Cancers. 14. PMID 35267630 DOI: 10.3390/cancers14051322  0.518
2020 Faridi P, Bossmann SH, Prakash P. Simulation-based design and characterization of a microwave applicator for MR-guided hyperthermia experimental studies in small animals. Biomedical Physics & Engineering Express. 6. PMID 32999735 DOI: 10.1088/2057-1976/Ab36Dd  0.362
2020 Fallahi H, Sebek J, Prakash P. Broadband Dielectric Properties of Ex Vivo Bovine Liver Tissue Characterized at Ablative Temperatures. Ieee Transactions On Bio-Medical Engineering. PMID 32746009 DOI: 10.1109/Tbme.2020.2996825  0.332
2020 Faridi P, Keselman P, Fallahi H, Prakash P. Experimental assessment of microwave ablation computational modeling with MR thermometry. Medical Physics. PMID 32506550 DOI: 10.1002/Mp.14318  0.361
2020 Pfannenstiel A, Sebek J, Fallahi H, Beard WL, Ganta CK, Dupuy DE, Prakash P. Directional Microwave Ablation: Experimental Evaluation of a 2.45-GHz Applicator in Ex Vivo and In Vivo Liver. Journal of Vascular and Interventional Radiology : Jvir. PMID 32171539 DOI: 10.1016/J.Jvir.2020.01.016  0.383
2019 Donlon PT, Fallahi H, Beard WL, Shahzad A, Heflin L, Cox W, Bloomberg B, Lillich JD, Ganta CK, O'Sullivan GJ, Ruvio G, O'Shea PM, O'Halloran M, Prakash P, Dennedy MC. Using microwave thermal ablation to develop a subtotal, cortical-sparing approach to the management of primary aldosteronism. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 36: 905-914. PMID 31466482 DOI: 10.1080/02656736.2019.1650205  0.303
2019 Sebek J, Bortel R, Prakash P. Broadband lung dielectric properties over the ablative temperature range: experimental measurements and parametric models. Medical Physics. PMID 31286530 DOI: 10.1002/Mp.13704  0.327
2019 Almekkawy M, Chen J, Ellis M, Haemmerich D, Holmes D, Linte C, Panescu D, Pearce J, Prakash P, Zderic V. Therapeutic Systems and Technologies: State-of-the-Art, Applications, Opportunities and Challenges. Ieee Reviews in Biomedical Engineering. PMID 30951478 DOI: 10.1109/Rbme.2019.2908940  0.561
2019 Fallahi H, Clausing D, Shahzad A, O’Halloran M, Dennedy MC, Prakash P. Microwave antennas for thermal ablation of benign adrenal adenomas Biomedical Physics & Engineering Express. 5: 25044. DOI: 10.1088/2057-1976/Ab068B  0.354
2018 Fallahi H, Prakash P. Antenna Designs for Microwave Tissue Ablation. Critical Reviews in Biomedical Engineering. 46: 495-521. PMID 30806212 DOI: 10.1615/Critrevbiomedeng.2018028554  0.398
2017 McWilliams BT, Wang H, Binns VJ, Curto S, Bossmann SH, Prakash P. Experimental Investigation of Magnetic Nanoparticle-Enhanced Microwave Hyperthermia. Journal of Functional Biomaterials. 8. PMID 28640198 DOI: 10.3390/Jfb8030021  0.332
2017 Curto S, Garcia-Miquel A, Suh M, Vidal N, Lopez-Villegas JM, Prakash P. Design and characterization of a phased antenna array for intact breast hyperthermia. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 1-35. PMID 28605946 DOI: 10.1080/02656736.2017.1337935  0.305
2017 Deshazer G, Hagmann M, Merck D, Sebek J, Moore KB, Prakash P. Computational modeling of 915 MHz microwave ablation: comparative assessment of temperature-dependent tissue dielectric models. Medical Physics. PMID 28543540 DOI: 10.1002/Mp.12359  0.338
2017 Prakash P, Haemmerich D. Introduction to microwave tumour ablation special issue. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 33: 1-2. PMID 28081679 DOI: 10.1080/02656736.2016.1221147  0.562
2017 Garcia-Miquel A, Curto S, Vidal N, Lopez-Villegas JM, Ramos FM, Prakash P. Multilayered broadband antenna for compact embedded implantable medical devices: Design and characterization Progress in Electromagnetics Research-Pier. 159: 1-13. DOI: 10.2528/Pier16121507  0.363
2017 Sebek J, Curto S, Eaton-Evans J, Bouchier-Hayes J, Ruvio G, Ganta C, Beard W, Buttar N, Song LWK, Prakash P. Feasibility Assessment of Microwave Ablation for Treating Esophageal Varices Journal of Medical Devices. 11. DOI: 10.1115/1.4037187  0.413
2016 Deshazer G, Prakash P, Merck D, Haemmerich D. Experimental measurement of microwave ablation heating pattern and comparison to computer simulations. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 1-9. PMID 27431040 DOI: 10.1080/02656736.2016.1206630  0.605
2016 Sebek J, Curto S, Bortel R, Prakash P. Analysis of minimally invasive directional antennas for microwave tissue ablation. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 1-10. PMID 27380439 DOI: 10.1080/02656736.2016.1195519  0.407
2016 Sebek J, Albin N, Bortel R, Natarajan B, Prakash P. Sensitivity of microwave ablation models to tissue biophysical properties: A first step toward probabilistic modeling and treatment planning. Medical Physics. 43: 2649. PMID 27147374 DOI: 10.1118/1.4947482  0.352
2016 Deshazer G, Merck D, Hagmann M, Dupuy DE, Prakash P. Physical modeling of microwave ablation zone clinical margin variance. Medical Physics. 43: 1764. PMID 27036574 DOI: 10.1118/1.4942980  0.348
2015 Curto S, Taj-Eldin M, Fairchild D, Prakash P. Microwave ablation at 915 MHz vs 2.45 GHz: A theoretical and experimental investigation. Medical Physics. 42: 6152. PMID 26520708 DOI: 10.1118/1.4931959  0.326
2015 McWilliams B, Schnell E, Curto S, Fahrbach T, Prakash P. A directional interstitial antenna for microwave tissue ablation: theoretical and experimental investigation. Ieee Transactions On Bio-Medical Engineering. PMID 25794385 DOI: 10.1109/Tbme.2015.2413672  0.409
2015 Salgaonkar V, Ozhinsky E, Rieke V, Prakash P, Hsu I, Kurhanewicz J, Diederich C. Implementation of sonication and feedback control strategies for targeted hyperthermia in prostate with a commercial MR-guided endorectal ultrasound ablation array Journal of Therapeutic Ultrasound. 3. DOI: 10.1186/2050-5736-3-S1-O62  0.3
2015 Deshazer G, Prakash P, Hagmann M, Dupuy D, Merck D. SU-E-T-394: Evaluation of Microwave Ablation Zone Variance Based On Reported Changes in Thermal and Electrical Properties of Tissues Medical Physics. 42: 3424-3424. DOI: 10.1118/1.4924755  0.387
2015 Mukherjee S, Curto S, Albin N, Natarajan B, Prakash P. Multiple-antenna microwave ablation: Analysis of non-parallel antenna implants Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9326. DOI: 10.1117/12.2080349  0.361
2015 Curto S, Ramasamy M, Suh M, Prakash P. Design and analysis of a conformal patch antenna for a wearable breast hyperthermia treatment system Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9326. DOI: 10.1117/12.2079718  0.369
2015 Scott SJ, Salgaonkar VA, Prakash P, Curto S, Hsu IC, Diederich CJ. Development of a fast 3D treatment planning platform for clinical interstitial microwave hyperthermia within free-hand obliquely implanted HDR catheters Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9326. DOI: 10.1117/12.2079701  0.367
2014 Scott SJ, Salgaonkar V, Prakash P, Burdette EC, Diederich CJ. Interstitial ultrasound ablation of vertebral and paraspinal tumours: parametric and patient-specific simulations. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 30: 228-44. PMID 25017322 DOI: 10.3109/02656736.2014.915992  0.331
2014 Salgaonkar VA, Prakash P, Rieke V, Ozhinsky E, Plata J, Kurhanewicz J, Hsu IC, Diederich CJ. Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MR-guided endorectal HIFU ablation array. Medical Physics. 41: 033301. PMID 24593742 DOI: 10.1118/1.4866226  0.371
2013 Prakash P, Salgaonkar VA, Scott SJ, Jones P, Hensley D, Holbrook A, Plata J, Sommer G, Diederich CJ. MR guided thermal therapy of pancreatic tumors with endoluminal, intraluminal and interstitial catheter-based ultrasound devices: Preliminary theoretical and experimental investigations. Proceedings of Spie--the International Society For Optical Engineering. 8584: 85840V. PMID 24860246 DOI: 10.1117/12.2004669  0.404
2013 Scott SJ, Prakash P, Salgaonkar V, Jones PD, Cam RN, Han M, Rieke V, Burdette EC, Diederich CJ. Approaches for modelling interstitial ultrasound ablation of tumours within or adjacent to bone: theoretical and experimental evaluations. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 29: 629-42. PMID 24102393 DOI: 10.3109/02656736.2013.841327  0.346
2013 Prakash P, Salgaonkar VA, Diederich CJ. Modelling of endoluminal and interstitial ultrasound hyperthermia and thermal ablation: applications for device design, feedback control and treatment planning. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 29: 296-307. PMID 23738697 DOI: 10.3109/02656736.2013.800998  0.399
2013 Salgaonkar VA, Rieke V, Ozhinsky E, Prakash P, Plata J, Kurhanewicz J, Hsu IC, Diederich CJ. Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MRI-guided endorectal high intensity focused ultrasound ablation array Journal of the Acoustical Society of America. 134: 4180-4180. DOI: 10.1121/1.4831325  0.335
2013 Diederich C, Salgaonkar V, Prakash P, Adams M, Scott S, Jones P, Hensley D, Chen H, Plata J, Holbrook A, Butts Pauly K, Sommer G. Catheter-based and endoluminal ultrasound applicators for magnetic resonance image-guided thermal therapy of pancreatic cancer: Preliminary investigations The Journal of the Acoustical Society of America. 134: 4089-4089. DOI: 10.1121/1.4830933  0.392
2013 Salgaonkar VA, Prakash P, Plata J, Holbrook A, Rieke V, Kurhanewicz J, Hsu IC, Diederich CJ. Targeted hyperthermia in prostate with an MR-guided endorectal ultrasound phased array: Patient specific modeling and preliminary experiments Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8584. DOI: 10.1117/12.2004609  0.338
2012 Prakash P, Salgaonkar VA, Clif Burdette E, Diederich CJ. Multiple applicator hepatic ablation with interstitial ultrasound devices: theoretical and experimental investigation. Medical Physics. 39: 7338-49. PMID 23231283 DOI: 10.1118/1.4765459  0.396
2012 Salgaonkar VA, Prakash P, Diederich CJ. Temperature superposition for fast computation of 3D temperature distributions during optimization and planning of interstitial ultrasound hyperthermia treatments. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 28: 235-49. PMID 22515345 DOI: 10.3109/02656736.2012.662666  0.313
2012 Prakash P, Diederich CJ. Considerations for theoretical modelling of thermal ablation with catheter-based ultrasonic sources: implications for treatment planning, monitoring and control. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 28: 69-86. PMID 22235787 DOI: 10.3109/02656736.2011.630337  0.372
2011 Diederich CJ, Wootton J, Prakash P, Salgaonkar V, Juang T, Scott S, Chen X, Cunha A, Pouliot J, Hsu IC. Catheter-based ultrasound hyperthermia with HDR brachytherapy for treatment of locally advanced cancer of the prostate and cervix. Proceedings of Spie--the International Society For Optical Engineering. 7901: 79010O. PMID 25076820 DOI: 10.1117/12.876401  0.374
2011 Wootton JH, Prakash P, Hsu IC, Diederich CJ. Implant strategies for endocervical and interstitial ultrasound hyperthermia adjunct to HDR brachytherapy for the treatment of cervical cancer. Physics in Medicine and Biology. 56: 3967-84. PMID 21666290 DOI: 10.1088/0031-9155/56/13/014  0.359
2011 Prakash P, Salgaonkar VA, Burdette EC, Diederich CJ. Hepatic ablation with multiple interstitial ultrasound applicators: Initial ex vivo and computational studies Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7901. DOI: 10.1117/12.876522  0.335
2011 Salgaonkar VA, Prakash P, Diederich CJ. Fast optimization and planning of clinical interstitial ultrasound hyperthermia using superposition and surrogate models of temperature distributions Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7901. DOI: 10.1117/12.876410  0.351
2010 Prakash P. Theoretical modeling for hepatic microwave ablation. The Open Biomedical Engineering Journal. 4: 27-38. PMID 20309393 DOI: 10.2174/1874120701004020027  0.405
2010 Burdette EC, Rucker DC, Prakash P, Diederich CJ, Croom JM, Clarke C, Stolka P, Juang T, Boctor EM, Webster RJ. The ACUSITT ultrasonic ablator: The first steerable needle with an integrated interventional tool Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7629. DOI: 10.1117/12.845972  0.361
2009 Prakash P, Converse MC, Webster JG, Mahvi DM. An optimal sliding choke antenna for hepatic microwave ablation. Ieee Transactions On Bio-Medical Engineering. 56: 2470-6. PMID 19535312 DOI: 10.1109/Tbme.2009.2025264  0.528
2008 Prakash P, Deng G, Converse MC, Webster JG, Mahvi DM, Ferris MC. Design optimization of a robust sleeve antenna for hepatic microwave ablation. Physics in Medicine and Biology. 53: 1057-69. PMID 18263958 DOI: 10.1088/0031-9155/53/4/016  0.499
2008 Prakash P, Converse MC, Webster JG, Mahvi DM. Design optimization of coaxial antennas for hepatic microwave ablation using genetic algorithms 2008 Ieee International Symposium On Antennas and Propagation and Usnc/Ursi National Radio Science Meeting, Apsursi. DOI: 10.1109/APS.2008.4619693  0.412
2007 O'Rourke AP, Haemmerich D, Prakash P, Converse MC, Mahvi DM, Webster JG. Current status of liver tumor ablation devices. Expert Review of Medical Devices. 4: 523-37. PMID 17605688 DOI: 10.1586/17434440.4.4.523  0.628
2006 Prakash P, Converse MC, Mahvi DM, Webster JG. Measurement of the specific heat capacity of liver phantom. Physiological Measurement. 27: N41-6. PMID 16951451 DOI: 10.1088/0967-3334/27/10/N01  0.504
Show low-probability matches.