Year |
Citation |
Score |
2022 |
Motamarry A, Wolfe AM, Ramajayam KK, Pattanaik S, Benton T, Peterson Y, Faridi P, Prakash P, Twombley K, Haemmerich D. Extracorporeal Removal of Thermosensitive Liposomal Doxorubicin from Systemic Circulation after Tumor Delivery to Reduce Toxicities. Cancers. 14. PMID 35267630 DOI: 10.3390/cancers14051322 |
0.518 |
|
2020 |
Faridi P, Bossmann SH, Prakash P. Simulation-based design and characterization of a microwave applicator for MR-guided hyperthermia experimental studies in small animals. Biomedical Physics & Engineering Express. 6. PMID 32999735 DOI: 10.1088/2057-1976/Ab36Dd |
0.362 |
|
2020 |
Fallahi H, Sebek J, Prakash P. Broadband Dielectric Properties of Ex Vivo Bovine Liver Tissue Characterized at Ablative Temperatures. Ieee Transactions On Bio-Medical Engineering. PMID 32746009 DOI: 10.1109/Tbme.2020.2996825 |
0.332 |
|
2020 |
Faridi P, Keselman P, Fallahi H, Prakash P. Experimental assessment of microwave ablation computational modeling with MR thermometry. Medical Physics. PMID 32506550 DOI: 10.1002/Mp.14318 |
0.361 |
|
2020 |
Pfannenstiel A, Sebek J, Fallahi H, Beard WL, Ganta CK, Dupuy DE, Prakash P. Directional Microwave Ablation: Experimental Evaluation of a 2.45-GHz Applicator in Ex Vivo and In Vivo Liver. Journal of Vascular and Interventional Radiology : Jvir. PMID 32171539 DOI: 10.1016/J.Jvir.2020.01.016 |
0.383 |
|
2019 |
Donlon PT, Fallahi H, Beard WL, Shahzad A, Heflin L, Cox W, Bloomberg B, Lillich JD, Ganta CK, O'Sullivan GJ, Ruvio G, O'Shea PM, O'Halloran M, Prakash P, Dennedy MC. Using microwave thermal ablation to develop a subtotal, cortical-sparing approach to the management of primary aldosteronism. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 36: 905-914. PMID 31466482 DOI: 10.1080/02656736.2019.1650205 |
0.303 |
|
2019 |
Sebek J, Bortel R, Prakash P. Broadband lung dielectric properties over the ablative temperature range: experimental measurements and parametric models. Medical Physics. PMID 31286530 DOI: 10.1002/Mp.13704 |
0.327 |
|
2019 |
Almekkawy M, Chen J, Ellis M, Haemmerich D, Holmes D, Linte C, Panescu D, Pearce J, Prakash P, Zderic V. Therapeutic Systems and Technologies: State-of-the-Art, Applications, Opportunities and Challenges. Ieee Reviews in Biomedical Engineering. PMID 30951478 DOI: 10.1109/Rbme.2019.2908940 |
0.561 |
|
2019 |
Fallahi H, Clausing D, Shahzad A, O’Halloran M, Dennedy MC, Prakash P. Microwave antennas for thermal ablation of benign adrenal adenomas Biomedical Physics & Engineering Express. 5: 25044. DOI: 10.1088/2057-1976/Ab068B |
0.354 |
|
2018 |
Fallahi H, Prakash P. Antenna Designs for Microwave Tissue Ablation. Critical Reviews in Biomedical Engineering. 46: 495-521. PMID 30806212 DOI: 10.1615/Critrevbiomedeng.2018028554 |
0.398 |
|
2017 |
McWilliams BT, Wang H, Binns VJ, Curto S, Bossmann SH, Prakash P. Experimental Investigation of Magnetic Nanoparticle-Enhanced Microwave Hyperthermia. Journal of Functional Biomaterials. 8. PMID 28640198 DOI: 10.3390/Jfb8030021 |
0.332 |
|
2017 |
Curto S, Garcia-Miquel A, Suh M, Vidal N, Lopez-Villegas JM, Prakash P. Design and characterization of a phased antenna array for intact breast hyperthermia. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 1-35. PMID 28605946 DOI: 10.1080/02656736.2017.1337935 |
0.305 |
|
2017 |
Deshazer G, Hagmann M, Merck D, Sebek J, Moore KB, Prakash P. Computational modeling of 915 MHz microwave ablation: comparative assessment of temperature-dependent tissue dielectric models. Medical Physics. PMID 28543540 DOI: 10.1002/Mp.12359 |
0.338 |
|
2017 |
Prakash P, Haemmerich D. Introduction to microwave tumour ablation special issue. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 33: 1-2. PMID 28081679 DOI: 10.1080/02656736.2016.1221147 |
0.562 |
|
2017 |
Garcia-Miquel A, Curto S, Vidal N, Lopez-Villegas JM, Ramos FM, Prakash P. Multilayered broadband antenna for compact embedded implantable medical devices: Design and characterization Progress in Electromagnetics Research-Pier. 159: 1-13. DOI: 10.2528/Pier16121507 |
0.363 |
|
2017 |
Sebek J, Curto S, Eaton-Evans J, Bouchier-Hayes J, Ruvio G, Ganta C, Beard W, Buttar N, Song LWK, Prakash P. Feasibility Assessment of Microwave Ablation for Treating Esophageal Varices Journal of Medical Devices. 11. DOI: 10.1115/1.4037187 |
0.413 |
|
2016 |
Deshazer G, Prakash P, Merck D, Haemmerich D. Experimental measurement of microwave ablation heating pattern and comparison to computer simulations. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 1-9. PMID 27431040 DOI: 10.1080/02656736.2016.1206630 |
0.605 |
|
2016 |
Sebek J, Curto S, Bortel R, Prakash P. Analysis of minimally invasive directional antennas for microwave tissue ablation. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 1-10. PMID 27380439 DOI: 10.1080/02656736.2016.1195519 |
0.407 |
|
2016 |
Sebek J, Albin N, Bortel R, Natarajan B, Prakash P. Sensitivity of microwave ablation models to tissue biophysical properties: A first step toward probabilistic modeling and treatment planning. Medical Physics. 43: 2649. PMID 27147374 DOI: 10.1118/1.4947482 |
0.352 |
|
2016 |
Deshazer G, Merck D, Hagmann M, Dupuy DE, Prakash P. Physical modeling of microwave ablation zone clinical margin variance. Medical Physics. 43: 1764. PMID 27036574 DOI: 10.1118/1.4942980 |
0.348 |
|
2015 |
Curto S, Taj-Eldin M, Fairchild D, Prakash P. Microwave ablation at 915 MHz vs 2.45 GHz: A theoretical and experimental investigation. Medical Physics. 42: 6152. PMID 26520708 DOI: 10.1118/1.4931959 |
0.326 |
|
2015 |
McWilliams B, Schnell E, Curto S, Fahrbach T, Prakash P. A directional interstitial antenna for microwave tissue ablation: theoretical and experimental investigation. Ieee Transactions On Bio-Medical Engineering. PMID 25794385 DOI: 10.1109/Tbme.2015.2413672 |
0.409 |
|
2015 |
Salgaonkar V, Ozhinsky E, Rieke V, Prakash P, Hsu I, Kurhanewicz J, Diederich C. Implementation of sonication and feedback control strategies for targeted hyperthermia in prostate with a commercial MR-guided endorectal ultrasound ablation array Journal of Therapeutic Ultrasound. 3. DOI: 10.1186/2050-5736-3-S1-O62 |
0.3 |
|
2015 |
Deshazer G, Prakash P, Hagmann M, Dupuy D, Merck D. SU-E-T-394: Evaluation of Microwave Ablation Zone Variance Based On Reported Changes in Thermal and Electrical Properties of Tissues Medical Physics. 42: 3424-3424. DOI: 10.1118/1.4924755 |
0.387 |
|
2015 |
Mukherjee S, Curto S, Albin N, Natarajan B, Prakash P. Multiple-antenna microwave ablation: Analysis of non-parallel antenna implants Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9326. DOI: 10.1117/12.2080349 |
0.361 |
|
2015 |
Curto S, Ramasamy M, Suh M, Prakash P. Design and analysis of a conformal patch antenna for a wearable breast hyperthermia treatment system Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9326. DOI: 10.1117/12.2079718 |
0.369 |
|
2015 |
Scott SJ, Salgaonkar VA, Prakash P, Curto S, Hsu IC, Diederich CJ. Development of a fast 3D treatment planning platform for clinical interstitial microwave hyperthermia within free-hand obliquely implanted HDR catheters Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9326. DOI: 10.1117/12.2079701 |
0.367 |
|
2014 |
Scott SJ, Salgaonkar V, Prakash P, Burdette EC, Diederich CJ. Interstitial ultrasound ablation of vertebral and paraspinal tumours: parametric and patient-specific simulations. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 30: 228-44. PMID 25017322 DOI: 10.3109/02656736.2014.915992 |
0.331 |
|
2014 |
Salgaonkar VA, Prakash P, Rieke V, Ozhinsky E, Plata J, Kurhanewicz J, Hsu IC, Diederich CJ. Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MR-guided endorectal HIFU ablation array. Medical Physics. 41: 033301. PMID 24593742 DOI: 10.1118/1.4866226 |
0.371 |
|
2013 |
Prakash P, Salgaonkar VA, Scott SJ, Jones P, Hensley D, Holbrook A, Plata J, Sommer G, Diederich CJ. MR guided thermal therapy of pancreatic tumors with endoluminal, intraluminal and interstitial catheter-based ultrasound devices: Preliminary theoretical and experimental investigations. Proceedings of Spie--the International Society For Optical Engineering. 8584: 85840V. PMID 24860246 DOI: 10.1117/12.2004669 |
0.404 |
|
2013 |
Scott SJ, Prakash P, Salgaonkar V, Jones PD, Cam RN, Han M, Rieke V, Burdette EC, Diederich CJ. Approaches for modelling interstitial ultrasound ablation of tumours within or adjacent to bone: theoretical and experimental evaluations. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 29: 629-42. PMID 24102393 DOI: 10.3109/02656736.2013.841327 |
0.346 |
|
2013 |
Prakash P, Salgaonkar VA, Diederich CJ. Modelling of endoluminal and interstitial ultrasound hyperthermia and thermal ablation: applications for device design, feedback control and treatment planning. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 29: 296-307. PMID 23738697 DOI: 10.3109/02656736.2013.800998 |
0.399 |
|
2013 |
Salgaonkar VA, Rieke V, Ozhinsky E, Prakash P, Plata J, Kurhanewicz J, Hsu IC, Diederich CJ. Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MRI-guided endorectal high intensity focused ultrasound ablation array Journal of the Acoustical Society of America. 134: 4180-4180. DOI: 10.1121/1.4831325 |
0.335 |
|
2013 |
Diederich C, Salgaonkar V, Prakash P, Adams M, Scott S, Jones P, Hensley D, Chen H, Plata J, Holbrook A, Butts Pauly K, Sommer G. Catheter-based and endoluminal ultrasound applicators for magnetic resonance image-guided thermal therapy of pancreatic cancer: Preliminary investigations The Journal of the Acoustical Society of America. 134: 4089-4089. DOI: 10.1121/1.4830933 |
0.392 |
|
2013 |
Salgaonkar VA, Prakash P, Plata J, Holbrook A, Rieke V, Kurhanewicz J, Hsu IC, Diederich CJ. Targeted hyperthermia in prostate with an MR-guided endorectal ultrasound phased array: Patient specific modeling and preliminary experiments Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8584. DOI: 10.1117/12.2004609 |
0.338 |
|
2012 |
Prakash P, Salgaonkar VA, Clif Burdette E, Diederich CJ. Multiple applicator hepatic ablation with interstitial ultrasound devices: theoretical and experimental investigation. Medical Physics. 39: 7338-49. PMID 23231283 DOI: 10.1118/1.4765459 |
0.396 |
|
2012 |
Salgaonkar VA, Prakash P, Diederich CJ. Temperature superposition for fast computation of 3D temperature distributions during optimization and planning of interstitial ultrasound hyperthermia treatments. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 28: 235-49. PMID 22515345 DOI: 10.3109/02656736.2012.662666 |
0.313 |
|
2012 |
Prakash P, Diederich CJ. Considerations for theoretical modelling of thermal ablation with catheter-based ultrasonic sources: implications for treatment planning, monitoring and control. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 28: 69-86. PMID 22235787 DOI: 10.3109/02656736.2011.630337 |
0.372 |
|
2011 |
Diederich CJ, Wootton J, Prakash P, Salgaonkar V, Juang T, Scott S, Chen X, Cunha A, Pouliot J, Hsu IC. Catheter-based ultrasound hyperthermia with HDR brachytherapy for treatment of locally advanced cancer of the prostate and cervix. Proceedings of Spie--the International Society For Optical Engineering. 7901: 79010O. PMID 25076820 DOI: 10.1117/12.876401 |
0.374 |
|
2011 |
Wootton JH, Prakash P, Hsu IC, Diederich CJ. Implant strategies for endocervical and interstitial ultrasound hyperthermia adjunct to HDR brachytherapy for the treatment of cervical cancer. Physics in Medicine and Biology. 56: 3967-84. PMID 21666290 DOI: 10.1088/0031-9155/56/13/014 |
0.359 |
|
2011 |
Prakash P, Salgaonkar VA, Burdette EC, Diederich CJ. Hepatic ablation with multiple interstitial ultrasound applicators: Initial ex vivo and computational studies Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7901. DOI: 10.1117/12.876522 |
0.335 |
|
2011 |
Salgaonkar VA, Prakash P, Diederich CJ. Fast optimization and planning of clinical interstitial ultrasound hyperthermia using superposition and surrogate models of temperature distributions Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7901. DOI: 10.1117/12.876410 |
0.351 |
|
2010 |
Prakash P. Theoretical modeling for hepatic microwave ablation. The Open Biomedical Engineering Journal. 4: 27-38. PMID 20309393 DOI: 10.2174/1874120701004020027 |
0.405 |
|
2010 |
Burdette EC, Rucker DC, Prakash P, Diederich CJ, Croom JM, Clarke C, Stolka P, Juang T, Boctor EM, Webster RJ. The ACUSITT ultrasonic ablator: The first steerable needle with an integrated interventional tool Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7629. DOI: 10.1117/12.845972 |
0.361 |
|
2009 |
Prakash P, Converse MC, Webster JG, Mahvi DM. An optimal sliding choke antenna for hepatic microwave ablation. Ieee Transactions On Bio-Medical Engineering. 56: 2470-6. PMID 19535312 DOI: 10.1109/Tbme.2009.2025264 |
0.528 |
|
2008 |
Prakash P, Deng G, Converse MC, Webster JG, Mahvi DM, Ferris MC. Design optimization of a robust sleeve antenna for hepatic microwave ablation. Physics in Medicine and Biology. 53: 1057-69. PMID 18263958 DOI: 10.1088/0031-9155/53/4/016 |
0.499 |
|
2008 |
Prakash P, Converse MC, Webster JG, Mahvi DM. Design optimization of coaxial antennas for hepatic microwave ablation using genetic algorithms 2008 Ieee International Symposium On Antennas and Propagation and Usnc/Ursi National Radio Science Meeting, Apsursi. DOI: 10.1109/APS.2008.4619693 |
0.412 |
|
2007 |
O'Rourke AP, Haemmerich D, Prakash P, Converse MC, Mahvi DM, Webster JG. Current status of liver tumor ablation devices. Expert Review of Medical Devices. 4: 523-37. PMID 17605688 DOI: 10.1586/17434440.4.4.523 |
0.628 |
|
2006 |
Prakash P, Converse MC, Mahvi DM, Webster JG. Measurement of the specific heat capacity of liver phantom. Physiological Measurement. 27: N41-6. PMID 16951451 DOI: 10.1088/0967-3334/27/10/N01 |
0.504 |
|
Show low-probability matches. |