Peter T. A. Reilly - Publications

Affiliations: 
Chemistry Washington State University, Pullman, WA, United States 
Website:
https://chem.wsu.edu/faculty/reilly-peter/

18 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2018 Hoffman NM, Opačić B, Reilly PT. Note: An inexpensive square waveform ion funnel driver. The Review of Scientific Instruments. 88: 016104. PMID 28147692 DOI: 10.1063/1.4974345  0.803
2017 Gotlib ZP, Brabeck GF, Reilly PT. Methodology and Characterization of Isolation and Preconcentration in a Gas-Filled Digital Linear Ion Guide. Analytical Chemistry. 89: 4287-4293. PMID 28282114 DOI: 10.1021/acs.analchem.7b00356  0.715
2016 Brabeck GF, Reilly PT. Computational Analysis of Quadrupole Mass Filters Employing Nontraditional Waveforms. Journal of the American Society For Mass Spectrometry. 27: 1122-7. PMID 27091594 DOI: 10.1007/s13361-016-1358-4  0.667
2014 Brabeck GF, Chen H, Hoffman NM, Wang L, Reilly PT. Development of MS(n) in digitally operated linear ion guides. Analytical Chemistry. 86: 7757-63. PMID 24964342 DOI: 10.1021/ac501685v  0.642
2012 Wang X, Chen H, Lee J, Reilly PT. Increasing the Trapping Mass Range to m/z = 10(9)-A Major Step Toward High Resolution Mass Analysis of Intact RNA, DNA and Viruses. International Journal of Mass Spectrometry. 328: 28-35. PMID 23129992 DOI: 10.1016/j.ijms.2012.07.024  0.702
2012 Chen H, Lee J, Reilly PT. High-resolution ultra-high mass spectrometry: increasing the m/z range of protein analysis. Proteomics. 12: 3020-9. PMID 22930644 DOI: 10.1002/pmic.201270136  0.732
2012 Liu T, Nedrow-Byers JR, Hopkins MR, Wu LY, Lee J, Reilly PT, Berkman CE. Targeting prostate cancer cells with a multivalent PSMA inhibitor-guided streptavidin conjugate. Bioorganic & Medicinal Chemistry Letters. 22: 3931-4. PMID 22607680 DOI: 10.1016/J.Bmcl.2012.04.110  0.357
2011 Lee J, Chen H, Liu T, Berkman CE, Reilly PT. High resolution time-of-flight mass analysis of the entire range of intact singly-charged proteins. Analytical Chemistry. 83: 9406-12. PMID 22047146 DOI: 10.1021/Ac202001Z  0.709
2011 Lee J, Marino MA, Koizumi H, Reilly PT. Simulation of Duty Cycle-Based Trapping and Ejection of Massive Ions Using Linear Digital Quadrupoles: the Enabling Technology for High Resolution Time-of-Flight Mass Spectrometry in the Ultra High Mass Range. International Journal of Mass Spectrometry. 304: 36-40. PMID 21731427 DOI: 10.1016/j.ijms.2011.03.011  0.714
2011 Lee J, Reilly PT. Limitation of time-of-flight resolution in the ultra high mass range. Analytical Chemistry. 83: 5831-3. PMID 21728303 DOI: 10.1021/ac201537b  0.525
2010 Koizumi H, Wang X, Whitten WB, Reilly PT. Controlling the expansion into vacuum-the enabling technology for trapping atmosphere-sampled particulate ions. Journal of the American Society For Mass Spectrometry. 21: 242-8. PMID 19926300 DOI: 10.1016/j.jasms.2009.10.009  0.498
2008 Koizumi H, Whitten WB, Reilly PT. Trapping of intact, singly-charged, bovine serum albumin ions injected from the atmosphere with a 10-cm diameter, frequency-adjusted linear quadrupole ion trap. Journal of the American Society For Mass Spectrometry. 19: 1942-7. PMID 18783963 DOI: 10.1016/j.jasms.2008.08.007  0.591
2007 Harris WA, Reilly PT, Whitten WB. Detection of chemical warfare-related species on complex aerosol particles deposited on surfaces using an ion trap-based aerosol mass spectrometer. Analytical Chemistry. 79: 2354-8. PMID 17269653 DOI: 10.1021/ac0620664  0.664
2005 Harris WA, Reilly PT, Whitten WB. MALDI of individual biomolecule-containing airborne particles in an ion trap mass spectrometer. Analytical Chemistry. 77: 4042-50. PMID 15987109 DOI: 10.1021/ac050187i  0.638
2004 Whitten WB, Reilly PT, Ramsey JM. High-pressure ion trap mass spectrometry. Rapid Communications in Mass Spectrometry : Rcm. 18: 1749-52. PMID 15282774 DOI: 10.1002/Rcm.1549  0.654
2004 Moxom J, Reilly PT, Whitten WB, Ramsey JM. Sample pressure effects in a micro ion trap mass spectrometer. Rapid Communications in Mass Spectrometry : Rcm. 18: 721-3. PMID 15052585 DOI: 10.1002/Rcm.1389  0.654
2003 Moxom J, Reilly PT, Whitten WB, Ramsey JM. Analysis of volatile organic compounds in air with a micro ion trap mass analyzer. Analytical Chemistry. 75: 3739-43. PMID 14572038  0.638
2002 Moxom J, Reilly PT, Whitten WB, Ramsey JM. Double resonance ejection in a micro ion trap mass spectrometer. Rapid Communications in Mass Spectrometry : Rcm. 16: 755-60. PMID 11921259 DOI: 10.1002/Rcm.635  0.679
Show low-probability matches.