Year |
Citation |
Score |
2024 |
Raj J, Millardet MB, Krishnamoorthy S, Karp JS, Surti S, Matej S. Recovery of the spatially-variant deformations in dual-panel PET reconstructions using deep-learning. Physics in Medicine and Biology. PMID 38330448 DOI: 10.1088/1361-6560/ad278e |
0.402 |
|
2023 |
Krishnamoorthy S, Surti S. Advances in Breast PET Instrumentation. Pet Clinics. 19: 37-47. PMID 37949606 DOI: 10.1016/j.cpet.2023.09.001 |
0.364 |
|
2021 |
Krishnamoorthy S, Teo BK, Zou W, McDonough J, Karp JS, Surti S. A proof-of-concept study of an in-situ partial-ring time-of-flight PET scanner for proton beam verification. Ieee Transactions On Radiation and Plasma Medical Sciences. 5: 694-702. PMID 34746539 DOI: 10.1109/trpms.2020.3044326 |
0.454 |
|
2020 |
Krishnamoorthy S, Vent T, Barufaldi B, Maidment ADA, Karp JS, Surti S. Evaluating attenuation correction strategies in a dedicated, single-gantry breast PET-tomosynthesis scanner. Physics in Medicine and Biology. PMID 33113520 DOI: 10.1088/1361-6560/abc5a8 |
0.344 |
|
2019 |
Gravel P, Surti S, Krishnamoorthy S, Karp JS, Matej S. Spatially-variant image-based modeling of PSF deformations with application to a limited angle geometry from a dual-panel breast-PET imager. Physics in Medicine and Biology. PMID 31569078 DOI: 10.1088/1361-6560/Ab4914 |
0.401 |
|
2018 |
Krishnamoorthy S, Blankemeyer E, Mollet P, Surti S, Van Holen R, Karp JS. Performance evaluation of the MOLECUBES β-CUBE - a high spatial resolution and high sensitivity small animal PET scanner utilizing monolithic LYSO scintillation detectors. Physics in Medicine and Biology. PMID 29938684 DOI: 10.1088/1361-6560/Aacec3 |
0.607 |
|
2014 |
Krishnamoorthy S, LeGeyt B, Werner ME, Kaul M, Newcomer FM, Karp JS, Surti S. Design and performance of a high spatial resolution, time-of-flight PET detector. Ieee Transactions On Nuclear Science. 61: 1092-1098. PMID 25246711 DOI: 10.1109/Tns.2014.2302580 |
0.467 |
|
2013 |
Krishnamoorthy S, Werner ME, Legeyt B, Kaul M, Karp JS, Surti S. Initial imaging results from a high spatial-resolution time-of-flight PET detector designed for dedicated breast imaging Ieee Nuclear Science Symposium Conference Record. DOI: 10.1109/NSSMIC.2013.6829091 |
0.449 |
|
2013 |
Krishnamoorthy S, Banu W. Discrimination metric for Bi-Histogram equalization of contrast enhancement 2013 Ieee 2nd International Conference On Image Information Processing, Ieee Iciip 2013. 267-270. DOI: 10.1109/ICIIP.2013.6707596 |
0.345 |
|
2012 |
Krishnamoorthy S, Wiener RI, Kaul M, Panetta J, Karp JS, Surti S. Development of a high-resolution and depth-of-interaction capable detector for time-of-flight PET Ieee Nuclear Science Symposium Conference Record. 2457-2461. DOI: 10.1109/NSSMIC.2011.6152667 |
0.333 |
|
2011 |
Schulz D, Southekal S, Junnarkar SS, Pratte JF, Purschke ML, Stoll SP, Ravindranath B, Maramraju SH, Krishnamoorthy S, Henn FA, O'Connor P, Woody CL, Schlyer DJ, Vaska P. Simultaneous assessment of rodent behavior and neurochemistry using a miniature positron emission tomograph. Nature Methods. 8: 347-52. PMID 21399637 DOI: 10.1038/Nmeth.1582 |
0.663 |
|
2011 |
Alexoff DL, Dewey SL, Vaska P, Krishnamoorthy S, Ferrieri R, Schueller M, Schlyer DJ, Fowler JS. PET imaging of thin objects: measuring the effects of positron range and partial-volume averaging in the leaf of Nicotiana tabacum. Nuclear Medicine and Biology. 38: 191-200. PMID 21315274 DOI: 10.1016/J.Nucmedbio.2010.08.004 |
0.648 |
|
2010 |
Smith SD, Maramraju SH, Southekal S, Ravindranath B, Krishnamoorthy S, Purschke M, Junnarkar S, Rescia S, Schulz D, Woody C, Stoll S, Vaska P, Carrion J, Schlyer D, Benveniste H. Simultaneous acquisition of MRI and PET cardiac cine 3D images at 9.4 Tesla Journal of Cardiovascular Magnetic Resonance. 12. DOI: 10.1186/1532-429X-12-S1-O59 |
0.691 |
|
2007 |
Pratte JF, Junnarkar S, Deptuch G, Fried J, O'Connor P, Radeka V, Vaska P, Woody C, Schlyer D, Stoll S, Maramraju SH, Krishnamoorthy S, Lecomte R, Fontaine R. The RatCAP front-end ASIC Ieee Nuclear Science Symposium Conference Record. 1: 19-25. DOI: 10.1109/Tns.2008.2004275 |
0.552 |
|
2007 |
Woody C, Schlyer D, Vaska P, Tomasi D, Solis-Najera S, Rooney W, Pratte JF, Junnarkar S, Stoll S, Master Z, Purschke M, Park SJ, Southekal S, Kriplani A, Krishnamoorthy S, et al. Preliminary studies of a simultaneous PET/MRI scanner based on the RatCAP small animal tomograph Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 571: 102-105. DOI: 10.1016/J.Nima.2006.10.039 |
0.685 |
|
2007 |
Woody C, Vaska P, Schlyer D, Pratte JF, Junnarkar S, Park SJ, Stoll S, Purschke M, Southekal S, Kriplani A, Krishnamoorthy S, Maramraju S, Lee D, Schiffer W, Dewey S, et al. Initial studies using the RatCAP conscious animal PET tomograph Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 571: 14-17. DOI: 10.1016/J.Nima.2006.10.019 |
0.681 |
|
Show low-probability matches. |