Joseph P. Culver - Publications

Affiliations: 
Biomedical Engineering Washington University, Saint Louis, St. Louis, MO 
Area:
Biomedical Engineering

173 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2023 Markow ZE, Tripathy K, Svoboda AM, Schroeder ML, Rafferty SM, Richter EJ, Eggebrecht AT, Anastasio MA, Chevillet MA, Mugler EM, Naufel SN, Yin A, Trobaugh JW, Culver JP. Identifying Naturalistic Movies from Human Brain Activity with High-Density Diffuse Optical Tomography. Biorxiv : the Preprint Server For Biology. PMID 38076976 DOI: 10.1101/2023.11.27.566650  0.701
2023 Sherafati A, Bajracharya A, Jones MS, Speh E, Munsi M, Lin CP, Fishell AK, Hershey T, Eggebrecht AT, Culver JP, Peelle JE. A high-density diffuse optical tomography dataset of naturalistic viewing. Biorxiv : the Preprint Server For Biology. PMID 37986896 DOI: 10.1101/2023.11.07.565473  0.667
2023 Lin CP, Orukari I, Frisk LK, Verma M, Chetia S, Beslija F, Eggebrecht AT, Durduran T, Culver JP, Trobaugh JW. Anatomical Modeling and Optimization of Speckle Contrast Optical Tomography. Biorxiv : the Preprint Server For Biology. PMID 37732196 DOI: 10.1101/2023.09.06.556565  0.712
2023 Markow ZE, Trobaugh JW, Richter EJ, Tripathy K, Rafferty SM, Svoboda AM, Schroeder ML, Burns-Yocum TM, Bergonzi KM, Chevillet MA, Mugler EM, Eggebrecht AT, Culver JP. Ultra-high density imaging arrays for diffuse optical tomography of human brain improve resolution, signal-to-noise, and information decoding. Biorxiv : the Preprint Server For Biology. PMID 37547013 DOI: 10.1101/2023.07.21.549920  0.727
2023 Schroeder ML, Sherafati A, Ulbrich RL, Wheelock MD, Svoboda AM, Klein ED, George TG, Tripathy K, Culver JP, Eggebrecht AT. Mapping cortical activations underlying covert and overt language production using high-density diffuse optical tomography. Neuroimage. 120190. PMID 37245559 DOI: 10.1016/j.neuroimage.2023.120190  0.673
2023 Brier LM, Culver JP. Open-source statistical and data processing tools for wide-field optical imaging data in mice. Neurophotonics. 10: 016601. PMID 36874217 DOI: 10.1117/1.NPh.10.1.016601  0.34
2022 Ayaz H, Baker WB, Blaney G, Boas DA, Bortfeld H, Brady K, Brake J, Brigadoi S, Buckley EM, Carp SA, Cooper RJ, Cowdrick KR, Culver JP, Dan I, Dehghani H, et al. Optical imaging and spectroscopy for the study of the human brain: status report. Neurophotonics. 9: S24001. PMID 36052058 DOI: 10.1117/1.NPh.9.S2.S24001  0.685
2022 Sherafati A, Dwyer N, Bajracharya A, Hassanpour MS, Eggebrecht AT, Firszt JB, Culver JP, Peelle JE. Prefrontal cortex supports speech perception in listeners with cochlear implants. Elife. 11. PMID 35666138 DOI: 10.7554/eLife.75323  0.608
2021 Yücel MA, Lühmann AV, Scholkmann F, Gervain J, Dan I, Ayaz H, Boas D, Cooper RJ, Culver J, Elwell CE, Eggebrecht A, Franceschini MA, Grova C, Homae F, Lesage F, et al. Errata: Best practices for fNIRS publications. Neurophotonics. 8: 019802. PMID 33575435 DOI: 10.1117/1.NPh.8.1.019802  0.546
2021 Yücel MA, Lühmann AV, Scholkmann F, Gervain J, Dan I, Ayaz H, Boas D, Cooper RJ, Culver J, Elwell CE, Eggebrecht A, Franceschini MA, Grova C, Homae F, Lesage F, et al. Best practices for fNIRS publications. Neurophotonics. 8: 012101. PMID 33442557 DOI: 10.1117/1.NPh.8.1.012101  0.599
2020 Tripathy K, Markow ZE, Fishell AK, Sherafati A, Burns-Yocum TM, Schroeder ML, Svoboda AM, Eggebrecht AT, Anastasio MA, Schlaggar BL, Culver JP. Decoding visual information from high-density diffuse optical tomography neuroimaging data. Neuroimage. 117516. PMID 33137479 DOI: 10.1364/Brain.2018.Btu4C.3  0.747
2020 Sherafati A, Snyder AZ, Eggebrecht AT, Bergonzi KM, Burns-Yocum TM, Lugar HM, Ferradal SL, Robichaux-Viehoever A, Smyser CD, Palanca BJ, Hershey T, Culver JP. Global motion detection and censoring in high-density diffuse optical tomography. Human Brain Mapping. PMID 32648643 DOI: 10.1002/Hbm.25111  0.798
2020 Fishell AK, Arbeláez AM, Valdés CP, Burns-Yocum TM, Sherafati A, Richter EJ, Torres M, Eggebrecht AT, Smyser CD, Culver JP. Portable, field-based neuroimaging using high-density diffuse optical tomography. Neuroimage. 116541. PMID 31987995 DOI: 10.1016/J.Neuroimage.2020.116541  0.722
2020 Banks HB, Bumstead JR, Brier LM, Bice A, Culver JP. Speed Considerations for Large Field Two-photon Microscopy in the Brain Brain. DOI: 10.1364/Brain.2020.Btu1C.5  0.326
2020 Dragojević T, Hollmann JL, Rosas EEV, Pasquinelli K, Cusini I, Culver JP, Villa F, Durduran T. Fast, high-density functional speckle contrast optical tomography of the adult brain Brain. DOI: 10.1364/Brain.2020.Bth3C.3  0.436
2020 Sherafati A, Hassanpour MS, Dwyer N, Fishell AK, Eggebrecht AT, Firszt JB, Culver JP, Peelle JE. Optical Neuroimaging of Speech Perception in Listeners with Cochlear Implants Brain. DOI: 10.1364/Brain.2020.Bm4C.4  0.639
2020 Landsness EC, Brier LM, Hua RX, Chen K, Rosenthal ZP, Culver JP, Lee J. 0126 Local Slow Wave Sleep and Post-Stroke Brain Repair Sleep. 43: A50-A50. DOI: 10.1093/Sleep/Zsaa056.124  0.332
2019 Dragojević T, Vidal Rosas EE, Hollmann JL, Culver JP, Justicia C, Durduran T. High-density speckle contrast optical tomography of cerebral blood flow response to functional stimuli in the rodent brain. Neurophotonics. 6: 045001. PMID 31620545 DOI: 10.1117/1.Nph.6.4.045001  0.499
2019 Fishell AK, Burns-Yocum TM, Bergonzi KM, Eggebrecht AT, Culver JP. Mapping brain function during naturalistic viewing using high-density diffuse optical tomography. Scientific Reports. 9: 11115. PMID 31366956 DOI: 10.1038/S41598-019-45555-8  0.688
2019 Wheelock MD, Culver JP, Eggebrecht AT. High-density diffuse optical tomography for imaging human brain function. The Review of Scientific Instruments. 90: 051101. PMID 31153254 DOI: 10.1063/1.5086809  0.773
2018 Bergonzi KM, Burns-Yocum TM, Bumstead JR, Buckley EM, Mannion PC, Tracy CH, Mennerick E, Ferradal SL, Dehghani H, Eggebrecht AT, Culver JP. Lightweight sCMOS-based high-density diffuse optical tomography. Neurophotonics. 5: 035006. PMID 30137925 DOI: 10.1117/1.Nph.5.3.035006  0.822
2018 Mitra A, Kraft A, Wright P, Acland B, Snyder AZ, Rosenthal Z, Czerniewski L, Bauer A, Snyder L, Culver J, Lee JM, Raichle ME. Spontaneous Infra-slow Brain Activity Has Unique Spatiotemporal Dynamics and Laminar Structure. Neuron. PMID 29606579 DOI: 10.1016/J.Neuron.2018.03.015  0.4
2018 Bumstead JR, Park JJ, Rosen IA, Kraft AW, Wright PW, Reisman MD, Côté DC, Culver JP. Designing a large field-of-view two-photon microscope using optical invariant analysis. Neurophotonics. 5: 025001. PMID 29487876 DOI: 10.1117/1.Nph.5.2.025001  0.43
2018 Dragojević T, Hollmann JL, Tamborini D, Portaluppi D, Buttafava M, Culver JP, Villa F, Durduran T. Compact, multi-exposure speckle contrast optical spectroscopy (SCOS) device for measuring deep tissue blood flow. Biomedical Optics Express. 9: 322-334. PMID 29359106 DOI: 10.1364/Boe.9.000322  0.321
2018 Rahn RM, Bice AR, Brier LM, Dougherty JD, Culver JP. Optical Imaging of Functional Connectivity Across Development in the Mouse Cortex Brain. DOI: 10.1364/Brain.2018.Btu2C.6  0.467
2018 Orukari I, Siegel JS, Bauer AQ, Baxter GA, Shimony JS, Rubin JB, Culver JP. Optical Imaging in a Mouse Model of Glioma Identifies Different Causes for Proximal and Distal Disruptions to Functional Connectivity Brain. DOI: 10.1364/Brain.2018.Bth2C.4  0.482
2017 Miller J, Wang ST, Orukari I, Prior J, Sudlow G, Su X, Liang K, Tang R, Hillman EMC, Weilbaecher KN, Culver JP, Berezin MY, Achilefu S. Perfusion-based fluorescence imaging method delineates diverse organs and identifies multifocal tumors using generic near infrared molecular probes. Journal of Biophotonics. PMID 29206348 DOI: 10.1002/Jbio.201700232  0.552
2017 Doulgerakis M, Eggebrecht A, Wojtkiewicz S, Culver J, Dehghani H. Toward real-time diffuse optical tomography: accelerating light propagation modeling employing parallel computing on GPU and CPU. Journal of Biomedical Optics. 22: 1-11. PMID 29197176 DOI: 10.1117/1.Jbo.22.12.125001  0.687
2017 Bauer AQ, Kraft AW, Baxter GA, Wright PW, Reisman MD, Bice AR, Park JJ, Bruchas MR, Snyder AZ, Lee JM, Culver JP. Effective Connectivity Measured Using Optogenetically Evoked Hemodynamic Signals Exhibits Topography Distinct from Resting State Functional Connectivity in the Mouse. Cerebral Cortex (New York, N.Y. : 1991). 1-17. PMID 29136125 DOI: 10.1093/Cercor/Bhx298  0.349
2017 Wright PW, Brier LM, Bauer AQ, Baxter GA, Kraft AW, Reisman MD, Bice AR, Snyder AZ, Lee JM, Culver JP. Functional connectivity structure of cortical calcium dynamics in anesthetized and awake mice. Plos One. 12: e0185759. PMID 29049297 DOI: 10.1371/Journal.Pone.0185759  0.421
2017 Hassanpour MS, Eggebrecht AT, Peelle JE, Culver JP. Mapping effective connectivity within cortical networks with diffuse optical tomography. Neurophotonics. 4: 041402. PMID 28744475 DOI: 10.1117/1.Nph.4.4.041402  0.71
2017 Wright PW, Archambault AS, Peek S, Bauer AQ, Culican SM, Ances BM, Culver JP, Wu GF. Functional connectivity alterations in a murine model of optic neuritis. Experimental Neurology. PMID 28502610 DOI: 10.1016/J.Expneurol.2017.05.004  0.354
2017 Reisman MD, Markow ZE, Bauer AQ, Culver JP. Structured illumination diffuse optical tomography for noninvasive functional neuroimaging in mice. Neurophotonics. 4: 021102. PMID 28439519 DOI: 10.1117/1.Nph.4.2.021102  0.506
2017 Dragojevi T, Varma HM, Hollmann JL, Valdes CP, Culver JP, Justicia C, Durduran T. High-density speckle contrast optical tomography (SCOT) for three dimensional tomographic imaging of the small animal brain. Neuroimage. PMID 28389382 DOI: 10.1016/J.Neuroimage.2017.04.003  0.473
2017 Bumstead JR, Rosen IA, Kraft AW, Wright PW, Côté D, Culver JP. Designing large field-of-view two photon microscopy using optical invariant analysis and off-the-shelf components Brain. DOI: 10.1364/Brain.2017.Brm4B.2  0.336
2017 Bauer AQ, Kraft A, Baxter GA, Bruchas MR, Lee J, Culver JP. Contralesional homotopic activity negatively influences functional recovery after stroke (Conference Presentation) Proceedings of Spie. 10052. DOI: 10.1117/12.2253719  0.344
2017 Bauer AQ, Kraft A, Baxter GA, Bruchas M, Lee J, Culver JP. Mapping cell-specific functional connections in the mouse brain using ChR2-evoked hemodynamics (Conference Presentation) Proceedings of Spie. 10051. DOI: 10.1117/12.2253100  0.403
2017 Orukari IE, Bauer AQ, Baxter GA, Rubin JB, Culver JP. An optical assessment of the effects of glioma growth on resting state networks in mice (Conference Presentation) Proceedings of Spie. 10051. DOI: 10.1117/12.2252817  0.368
2017 Sherafati A, Eggebrecht AT, Burns-Yocum TM, Culver JP. A global metric to detect motion artifacts in optical neuroimaging data (Conference Presentation) Proceedings of Spie. 10051: 1005112. DOI: 10.1117/12.2252417  0.662
2017 Bumstead J, Côté DC, Culver JP. Development of large field-of-view two photon microscopy for imaging mouse cortex (Conference Presentation) Proceedings of Spie. 10069. DOI: 10.1117/12.2251433  0.472
2016 Culver JP, Bergonzi KM, Eggebrecht AE, Fishell AK, Jin-Moo Lee. Optical imaging of functional connectivity at the bedside. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2016: 65-67. PMID 28268282 DOI: 10.1109/EMBC.2016.7590641  0.454
2016 Culver JP, Bergonzi KM, Eggebrecht AE, Fishell AK, Lee JM, Culver JP, Bergonzi KM, Eggebrecht AE, Fishell AK, Jin-Moo Lee, Fishell AK, Culver JP, Lee JM, Bergonzi KM, Eggebrecht AE. Optical imaging of functional connectivity at the bedside. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2016: 65-67. PMID 28226439 DOI: 10.1109/EMBC.2016.7590641  0.454
2016 Ferrari M, Culver JP, Hoshi Y, Wabnitz H. Special Section Guest Editorial:Clinical near-infrared spectroscopy and imaging of the brain. Neurophotonics. 3: 031401. PMID 27725945 DOI: 10.1117/1.Nph.3.3.031401  0.399
2016 Ferrari M, Culver JP, Hoshi Y, Wabnitz H. Special Section Guest Editorial:Clinical near-infrared spectroscopy and imaging of the brain. Journal of Biomedical Optics. 21: 91301. PMID 27653998 DOI: 10.1117/1.Jbo.21.9.091301  0.399
2016 Bumstead JR, Bauer AQ, Wright PW, Culver JP. Cerebral functional connectivity and Mayer waves in mice: Phenomena and separability. Journal of Cerebral Blood Flow and Metabolism : Official Journal of the International Society of Cerebral Blood Flow and Metabolism. PMID 26868180 DOI: 10.1177/0271678X16629977  0.306
2016 Fishell AK, Eggebrecht AT, Petersen SE, Culver JP. Response Reproducibility and Functional Localization using High-Density Diffuse Optical Tomography During Naturalistic Viewing Brain. DOI: 10.1364/Brain.2016.Bth4D.6  0.686
2016 Hollmann JL, Dragojević T, Varma HM, Justicia C, Valdes CP, Culver JP, Durduran T. High density speckle contrast optical tomography for transcranial, three-dimensional imaging of cerebral blood flow in rodents Brain. DOI: 10.1364/Brain.2016.Bth2D.5  0.428
2016 Bauer AQ, Baxter GA, Kraft AW, Bruchas MR, Lee J, Culver JP. Mapping Large-Scale, Cell-Specific Functional Connections with Chr2-evoked Hemodynamic Signals Brain. DOI: 10.1364/Brain.2016.Bm4D.5  0.376
2015 Wu X, Eggebrecht AT, Ferradal SL, Culver JP, Dehghani H. Fast and efficient image reconstruction for high density diffuse optical imaging of the human brain. Biomedical Optics Express. 6: 4567-4584. PMID 26601019 DOI: 10.1364/Boe.6.004567  0.82
2015 Wu X, Eggebrecht AT, Ferradal SL, Culver JP, Dehghani H. Evaluation of rigid registration methods for whole head imaging in diffuse optical tomography. Neurophotonics. 2: 035002. PMID 26217675 DOI: 10.1117/1.Nph.2.3.035002  0.843
2015 Hassanpour MS, Eggebrecht AT, Culver JP, Peelle JE. Mapping cortical responses to speech using high-density diffuse optical tomography. Neuroimage. 117: 319-26. PMID 26026816 DOI: 10.1016/J.Neuroimage.2015.05.058  0.707
2015 Ferradal SL, Liao SM, Eggebrecht AT, Shimony JS, Inder TE, Culver JP, Smyser CD. Functional Imaging of the Developing Brain at the Bedside Using Diffuse Optical Tomography. Cerebral Cortex (New York, N.Y. : 1991). PMID 25595183 DOI: 10.1093/Cercor/Bhu320  0.832
2015 Culver JP. Optical imaging of functional connectivity Optics and the Brain, Brain 2015. DOI: 10.1364/Brain.2015.Brm4B.1  0.515
2015 Wu X, Eggebrecht AT, Ferradal SL, Culver JP, Dehghani H. Efficient method for near real-time diffuse optical tomography of the human brain Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9538. DOI: 10.1117/12.2183723  0.811
2015 Wu X, Eggebrecht AT, Ferradal SL, Culver JP, Dehghani H. Atlas-based high-density diffuse optical tomography for imaging the whole human cortex Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9319. DOI: 10.1117/12.2075339  0.825
2014 Wu X, Eggebrecht AT, Ferradal SL, Culver JP, Dehghani H. Quantitative evaluation of atlas-based high-density diffuse optical tomography for imaging of the human visual cortex. Biomedical Optics Express. 5: 3882-900. PMID 25426318 DOI: 10.1364/Boe.5.003882  0.82
2014 Maji D, Solomon M, Nguyen A, Pierce RA, Woodard PK, Akers WJ, Achilefu S, Culver JP, Abendschein DR, Shokeen M. Noninvasive imaging of focal atherosclerotic lesions using fluorescence molecular tomography. Journal of Biomedical Optics. 19: 110501. PMID 25389566 DOI: 10.1117/1.Jbo.19.11.110501  0.526
2014 Valdes CP, Varma HM, Kristoffersen AK, Dragojevic T, Culver JP, Durduran T. Speckle contrast optical spectroscopy, a non-invasive, diffuse optical method for measuring microvascular blood flow in tissue. Biomedical Optics Express. 5: 2769-84. PMID 25136500 DOI: 10.1364/Boe.5.002769  0.412
2014 Eggebrecht AT, Ferradal SL, Robichaux-Viehoever A, Hassanpour MS, Dehghani H, Snyder AZ, Hershey T, Culver JP. Mapping distributed brain function and networks with diffuse optical tomography. Nature Photonics. 8: 448-454. PMID 25083161 DOI: 10.1038/Nphoton.2014.107  0.834
2014 Liao SM, Culver JP. Near infrared optical technologies to illuminate the status of the neonatal brain. Current Pediatric Reviews. 10: 73-86. PMID 25055866 DOI: 10.2174/157339631001140408121507  0.433
2014 Bauer AQ, Kraft AW, Wright PW, Snyder AZ, Lee JM, Culver JP. Optical imaging of disrupted functional connectivity following ischemic stroke in mice. Neuroimage. 99: 388-401. PMID 24862071 DOI: 10.1016/J.Neuroimage.2014.05.051  0.386
2014 Varma HM, Valdes CP, Kristoffersen AK, Culver JP, Durduran T. Speckle contrast optical tomography: A new method for deep tissue three-dimensional tomography of blood flow. Biomedical Optics Express. 5: 1275-89. PMID 24761306 DOI: 10.1364/Boe.5.001275  0.37
2014 Nasiriavanaki M, Xia J, Wan H, Bauer AQ, Culver JP, Wang LV. High-resolution photoacoustic tomography of resting-state functional connectivity in the mouse brain. Proceedings of the National Academy of Sciences of the United States of America. 111: 21-6. PMID 24367107 DOI: 10.1073/Pnas.1311868111  0.503
2014 Hassanpour MS, White BR, Eggebrecht AT, Ferradal SL, Snyder AZ, Culver JP. Statistical analysis of high density diffuse optical tomography. Neuroimage. 85: 104-16. PMID 23732886 DOI: 10.1016/J.Neuroimage.2013.05.105  0.821
2014 Ferradal SL, Eggebrecht AT, Hassanpour M, Snyder AZ, Culver JP. Atlas-based head modeling and spatial normalization for high-density diffuse optical tomography: in vivo validation against fMRI. Neuroimage. 85: 117-26. PMID 23578579 DOI: 10.1016/J.Neuroimage.2013.03.069  0.828
2014 Varma HM, Valdes CP, Kristoffersen AK, Culver JP, Durduran T. Speckle contrast optical tomography (SCOT): Reconstructing the three dimensional distribution of blood flow in deep tissues Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2014.Bw3B.2  0.416
2014 Ferradal SL, Liao SM, Eggebrecht AT, Shimony J, Inder TE, Culver JP, Smyser CD. DOT imaging of the developing brain: A validation study against functional MRI Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2014.Bw2B.2  0.815
2014 Eggebrecht AT, Ferradal SL, Robichaux-Viehoever A, Hassanpour MS, Dehghani H, Snyder AZ, Hershey T, Culver JP. Mapping higher-order brain function and resting-state networks with diffuse optical tomography Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2014.Bt5B.1  0.831
2014 Bumstead JR, Bauer AQ, Culver JP. Cerebral functional connectivity and vasomotion: phenomena and separability Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2014.Bt4B.6  0.305
2014 Hassanpour MS, Eggebrecht AT, Peelle JE, Culver JP. Modulation of effective connectivity by cognitive demands in an auditory speech processing task: A functional high density diffuse optical tomography study Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2014.Bt3A.36  0.671
2014 Wu X, Eggebrecht AT, Ferradal SL, Culver JP, Dehghani H. Evaluation of Atlas-Based Diffuse Optical Tomography Using Different Registration Methods for Image Recovery Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2014.Bm3A.7  0.816
2014 Hassanpour MS, Eggebrecht AT, Peelle JE, Culver JP. Imaging speech comprehension in quiet with high density diffuse optical tomography Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2014.Bm3A.5  0.725
2014 Wright PW, Bauer AQ, Culver JP. Spontaneous FAD Dynamics Reveal Functional Connectivity Patterns In Mice Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2014.Bm3A.4  0.366
2014 Bergonzi KM, Bauer AQ, Wright PW, Culver JP. Simultaneous CBF and [HbO] Resting-State Functional Connectivity in Mice Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2014.Bm3A.3  0.305
2014 Bauer AQ, Kraft AW, Wright PW, Snyder AZ, Lee J, Culver JP. Functional connectivity disruption in a mouse model of ischemic stroke Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2014.Bm3A.2  0.337
2014 Erpelding TN, Maslov K, Appleton C, Margenthaler JA, Pashley MD, Zou J, Culver JP, Akers WJ, Achilefu S, Pan D, Lanza GM, Wang LV. Clinical translation of photoacoustic tomography Translational Research in Biophotonics: Four National Cancer Institute Case Studies. 83-157. DOI: 10.1117/3.1002515.ch5  0.402
2014 Avanaki MRN, Xia J, Wan HW, Bauer AQ, Culver JP, Wang LV. Imaging technology in mice enhances human brain research Spie Newsroom. DOI: 10.1117/2.1201402.005349  0.449
2014 Nasiriavanaki M, Xia J, Wan H, Bauer AQ, Culver JP, Wang LV. Resting-state functional connectivity imaging of the mouse brain using photoacoustic tomography Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8943. DOI: 10.1117/12.2036606  0.508
2013 Liu Y, Akers WJ, Bauer AQ, Mondal S, Gullicksrud K, Sudlow GP, Culver JP, Achilefu S. Intraoperative detection of liver tumors aided by a fluorescence goggle system and multimodal imaging. The Analyst. 138: 2254-7. PMID 23467534 DOI: 10.1039/C3An00165B  0.549
2013 Solomon M, Nothdruft RE, Akers W, Edwards WB, Liang K, Xu B, Suddlow GP, Deghani H, Tai YC, Eggebrecht AT, Achilefu S, Culver JP. Multimodal fluorescence-mediated tomography and SPECT/CT for small-animal imaging. Journal of Nuclear Medicine : Official Publication, Society of Nuclear Medicine. 54: 639-46. PMID 23447655 DOI: 10.2967/Jnumed.112.105742  0.765
2013 Wu X, Eggebrecht AT, Culver JP, Zhan Y, Basevi H, Dehghani H. Quantitative evaluation of registration methods for atlas-based Diffuse Optical Tomography Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8799. DOI: 10.1117/12.2033277  0.675
2012 Liao SM, Ferradal SL, White BR, Gregg N, Inder TE, Culver JP. High-density diffuse optical tomography of term infant visual cortex in the nursery. Journal of Biomedical Optics. 17: 081414. PMID 23224175 DOI: 10.1117/1.Jbo.17.8.081414  0.776
2012 Zhan Y, Eggebrecht AT, Culver JP, Dehghani H. Singular value decomposition based regularization prior to spectral mixing improves crosstalk in dynamic imaging using spectral diffuse optical tomography. Biomedical Optics Express. 3: 2036-49. PMID 23024899 DOI: 10.1364/Boe.3.002036  0.712
2012 Nothdurft R, Sarder P, Bloch S, Culver J, Achilefu S. Fluorescence lifetime imaging microscopy using near-infrared contrast agents. Journal of Microscopy. 247: 202-7. PMID 22788550 DOI: 10.1111/J.1365-2818.2012.03634.X  0.543
2012 Zhan Y, Eggebrecht AT, Culver JP, Dehghani H. Image quality analysis of high-density diffuse optical tomography incorporating a subject-specific head model. Frontiers in Neuroenergetics. 4: 6. PMID 22654754 DOI: 10.3389/Fnene.2012.00006  0.751
2012 Aldrich MB, Marshall MV, Sevick-Muraca EM, Lanza G, Kotyk J, Culver J, Wang LV, Uddin J, Crews BC, Marnett LJ, Liao JC, Contag C, Crawford JM, Wang K, Reisdorph B, et al. Seeing it through: translational validation of new medical imaging modalities. Biomedical Optics Express. 3: 764-76. PMID 22574264 DOI: 10.1364/Boe.3.000764  0.388
2012 Bero AW, Bauer AQ, Stewart FR, White BR, Cirrito JR, Raichle ME, Culver JP, Holtzman DM. Bidirectional relationship between functional connectivity and amyloid-β deposition in mouse brain. The Journal of Neuroscience : the Official Journal of the Society For Neuroscience. 32: 4334-40. PMID 22457485 DOI: 10.1523/Jneurosci.5845-11.2012  0.341
2012 Eggebrecht AT, White BR, Ferradal SL, Chen C, Zhan Y, Snyder AZ, Dehghani H, Culver JP. A quantitative spatial comparison of high-density diffuse optical tomography and fMRI cortical mapping. Neuroimage. 61: 1120-8. PMID 22330315 DOI: 10.1016/J.Neuroimage.2012.01.124  0.838
2012 White BR, Liao SM, Ferradal SL, Inder TE, Culver JP. Bedside optical imaging of occipital resting-state functional connectivity in neonates. Neuroimage. 59: 2529-38. PMID 21925609 DOI: 10.1016/J.Neuroimage.2011.08.094  0.754
2012 Patwardhan S, Bloch S, Achilefu S, Culver J. Time-dependent whole-body fluorescence tomography of probe bio-distributions in mice. Optics Express. 13: 2564-77. PMID 19495147 DOI: 10.1364/opex.13.002564  0.502
2012 Culver JP, Ntziachristos V, Holboke MJ, Yodh AG. Optimization of optode arrangements for diffuse optical tomography: A singular-value analysis. Optics Letters. 26: 701-3. PMID 18040425 DOI: 10.1364/Ol.26.000701  0.441
2012 Zhan Y, Eggebrecht A, Culver J, Dehghani H. Spectrally constrained functional diffuse optical tomography of the adult brain Biomedical Optics, Biomed 2012. JM3A.68. DOI: 10.1364/Biomed.2012.Jm3A.68  0.719
2012 Liu Y, Akers W, Bauer AQ, Sudlow G, Liang K, Culver JP, Achilefu S. Fluorescence goggle system for surgical navigation Biomedical Optics, Biomed 2012. BW1B.2. DOI: 10.1364/Biomed.2012.Bw1B.2  0.513
2012 Ferradal SL, Liao SM, Eggebrecht AT, Inder TE, Culver JP. Functional connectivity mapping in hospitalized infants using diffuse optical tomography Biomedical Optics, Biomed 2012. BSu4A.7. DOI: 10.1364/Biomed.2012.Bsu4A.7  0.8
2012 Hassanpour M, White BR, Eggebrecht AT, Ferradal S, Culver JP. Optimizing statistical analysis for DOT to image rapid brain function events Biomedical Optics, Biomed 2012. Bsu3A.71. DOI: 10.1364/Biomed.2012.Bsu3A.71  0.801
2012 Bauer AQ, White BR, Snyder AZ, Schlaggar BL, Lee JM, Culver JP. Optical intrinsic signal imaging of functional connectivity in the mouse brain Biomedical Optics, Biomed 2012. BM4A.7. DOI: 10.1364/Biomed.2012.Bm4A.7  0.46
2012 Solomon M, Nothdruft RE, Akers W, Edwards WB, Liang K, Xu B, Deghani H, Tai Y, Achilefu S, Culver JP. Multimodal video-rate fluorescence DOT and SPECT/CT for small animals Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2012.Bm2A.6  0.564
2012 Liu Y, Bauer AQ, Akers W, Sudlow G, Liang K, Charanya T, Mondal S, Culver JP, Achilefu S. Fluorescence goggle for intraoperative breast cancer imaging Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8215. DOI: 10.1117/12.910509  0.52
2011 Solomon M, White BR, Nothdruft RE, Akers W, Sudlow G, Eggebrecht AT, Achilefu S, Culver JP. Video-rate fluorescence diffuse optical tomography for in vivo sentinel lymph node imaging. Biomedical Optics Express. 2: 3267-77. PMID 22162817 DOI: 10.1364/Boe.2.003267  0.75
2011 Bauer AQ, Nothdurft RE, Erpelding TN, Wang LV, Culver JP. Quantitative photoacoustic imaging: correcting for heterogeneous light fluence distributions using diffuse optical tomography. Journal of Biomedical Optics. 16: 096016. PMID 21950930 DOI: 10.1117/1.3626212  0.49
2011 Berezin MY, Guo K, Akers W, Northdurft RE, Culver JP, Teng B, Vasalatiy O, Barbacow K, Gandjbakhche A, Griffiths GL, Achilefu S. Near-infrared fluorescence lifetime pH-sensitive probes. Biophysical Journal. 100: 2063-72. PMID 21504743 DOI: 10.1016/J.Bpj.2011.02.050  0.481
2011 Liu Y, Bauer AQ, Akers WJ, Sudlow G, Liang K, Shen D, Berezin MY, Culver JP, Achilefu S. Hands-free, wireless goggles for near-infrared fluorescence and real-time image-guided surgery. Surgery. 149: 689-98. PMID 21496565 DOI: 10.1016/J.Surg.2011.02.007  0.516
2011 White BR, Bauer AQ, Snyder AZ, Schlaggar BL, Lee JM, Culver JP. Imaging of functional connectivity in the mouse brain. Plos One. 6: e16322. PMID 21283729 DOI: 10.1371/Journal.Pone.0016322  0.42
2011 Liu Y, Bauer AQ, Akers W, Sudlow G, Liang K, Shen D, Berezin M, Culver JP, Achilefu S. Compact intraoperative imaging device for sentinel lymph node mapping Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7910. DOI: 10.1117/12.886226  0.527
2011 Bauer AQ, Nothdurft RE, Erpelding TN, Wang LV, Culver JP. Quantitative, high-resolution photoacoustic spectroscopy by combining photoacoustic imaging with diffuse optical tomography Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7899. DOI: 10.1117/12.875549  0.496
2011 Zhan Y, Eggebrecht A, Dehghani H, Culver J. Quantitative evaluation of systematic imaging error due to uncertainty in tissue optical properties in high-density diffuse optical tomography Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7896. DOI: 10.1117/12.873746  0.742
2010 Gregg NM, White BR, Zeff BW, Berger AJ, Culver JP. Brain specificity of diffuse optical imaging: improvements from superficial signal regression and tomography. Frontiers in Neuroenergetics. 2. PMID 20725524 DOI: 10.3389/Fnene.2010.00014  0.509
2010 Liao SM, Gregg NM, White BR, Zeff BW, Bjerkaas KA, Inder TE, Culver JP. Neonatal hemodynamic response to visual cortex activity: high-density near-infrared spectroscopy study. Journal of Biomedical Optics. 15: 026010. PMID 20459255 DOI: 10.1117/1.3369809  0.31
2010 White BR, Culver JP. Quantitative evaluation of high-density diffuse optical tomography: in vivo resolution and mapping performance. Journal of Biomedical Optics. 15: 026006. PMID 20459251 DOI: 10.1364/Biomed.2010.Jma54  0.548
2010 White BR, Culver JP. Phase-encoded retinotopy as an evaluation of diffuse optical neuroimaging. Neuroimage. 49: 568-77. PMID 19631755 DOI: 10.1016/J.Neuroimage.2009.07.023  0.532
2010 Ferradal SL, White BR, Dosenbach R, Culver JP. Bedside monitoring of cerebral oxygenation using DOT Optics Infobase Conference Papers. DOI: 10.1364/Biomed.2010.Jma85  0.749
2010 Zhan Y, Dehghani H, White BR, Culver JP. Application of subject specific models for mapping brain function with diffuse optical tomography Optics Infobase Conference Papers. DOI: 10.1364/Biomed.2010.Jma62  0.53
2010 Bauer AQ, Nothdurft RE, Li C, Wang LV, Culver JP. Correcting for Heterogeneous Fluence Profiles in Photoacoustic Imaging with Diffuse Optical Tomography Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2010.Btud24  0.477
2010 White BR, Liao SM, Ferradal SL, Inder TE, Culver JP. Functional Connectivity DOT: Development and Clinical Implications in Infants Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2010.Btub1  0.705
2010 Nothdurft RE, Berezin MY, Achilefu S, Culver JP. Diffuse Optical Tomography of Heterogeneous Fluorophore Lifetimes Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2010.Bsud50  0.582
2010 Chen C, Wu J, Eggebrecht AT, White BR, Chen B, Achilefu S, Culver JP. Hybrid Level-Set Segmentation of MRI on Optical Properties Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2010.Bsud32  0.712
2010 Ptaszek M, Kee HL, Muthiah C, Nothdurft R, Akers W, Achilefu S, Culver JP, Holten D. Near-infrared molecular imaging probes based on chlorin-bacteriochlorin dyads Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7576. DOI: 10.1117/12.842007  0.546
2010 White BR, Culver JP. Noninvasive diffuse optics for brain mapping Access Science. DOI: 10.1036/1097-8542.Yb100115  0.439
2010 White BR, Culver JP. A quantitative evaluation of high-density diffuse optical tomography: In vivo resolution and mapping performance Optics Infobase Conference Papers 0.458
2009 White BR, Snyder AZ, Cohen AL, Petersen SE, Raichle ME, Schlaggar BL, Culver JP. Mapping the human brain at rest with diffuse optical tomography. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2009: 4070-2. PMID 19964102 DOI: 10.1109/IEMBS.2009.5333199  0.413
2009 Lee H, Akers WJ, Cheney PP, Edwards WB, Liang K, Culver JP, Achilefu S. Complementary optical and nuclear imaging of caspase-3 activity using combined activatable and radio-labeled multimodality molecular probe. Journal of Biomedical Optics. 14: 040507. PMID 19725712 DOI: 10.1117/1.3207156  0.551
2009 Zhang Z, Fan J, Cheney PP, Berezin MY, Edwards WB, Akers WJ, Shen D, Liang K, Culver JP, Achilefu S. Activatable molecular systems using homologous near-infrared fluorescent probes for monitoring enzyme activities in vitro, in cellulo, and in vivo. Molecular Pharmaceutics. 6: 416-27. PMID 19718795 DOI: 10.1021/Mp800264K  0.49
2009 Choe R, Konecky SD, Corlu A, Lee K, Durduran T, Busch DR, Pathak S, Czerniecki BJ, Tchou J, Fraker DL, Demichele A, Chance B, Arridge SR, Schweiger M, Culver JP, et al. Differentiation of benign and malignant breast tumors by in-vivo three-dimensional parallel-plate diffuse optical tomography. Journal of Biomedical Optics. 14: 024020. PMID 19405750 DOI: 10.1117/1.3103325  0.397
2009 Nothdurft RE, Patwardhan SV, Akers W, Ye Y, Achilefu S, Culver JP. In vivo fluorescence lifetime tomography. Journal of Biomedical Optics. 14: 024004. PMID 19405734 DOI: 10.1117/1.3086607  0.621
2009 White BR, Snyder AZ, Cohen AL, Petersen SE, Raichle ME, Schlaggar BL, Culver JP. Resting-state functional connectivity in the human brain revealed with diffuse optical tomography. Neuroimage. 47: 148-56. PMID 19344773 DOI: 10.1016/J.Neuroimage.2009.03.058  0.521
2009 Culver JP, Drexler W, Drezek RA, Georgakoudi I, Hillman EM, Richards-Kortum R. Topics in Biomedical Optics: introduction to the feature issue. Applied Optics. 48: TBO1-2. PMID 19340130 DOI: 10.1364/Ao.48.00Tbo1  0.362
2009 Dehghani H, White BR, Zeff BW, Tizzard A, Culver JP. Depth sensitivity and image reconstruction analysis of dense imaging arrays for mapping brain function with diffuse optical tomography. Applied Optics. 48: D137-43. PMID 19340101 DOI: 10.1364/Ao.48.00D137  0.533
2009 Markham J, White BR, Zeff BW, Culver JP. Blind identification of evoked human brain activity with independent component analysis of optical data. Human Brain Mapping. 30: 2382-92. PMID 19180556 DOI: 10.1002/Hbm.20678  0.476
2009 Dehghani H, White BR, Zeff BW, Tizzard A, Culver JP. Depth sensitivity analysis of high-density imaging arrays for mapping brain function with diffuse optical tomography Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7174. DOI: 10.1117/12.807746  0.429
2009 White B, Dosenbach R, Snyder A, Raichle M, Culver J. Examining resting-state physiology with functional diffuse optical tomography Neuroimage. 47. DOI: 10.1016/S1053-8119(09)71729-X  0.419
2009 Gregg N, White B, Culver J. High-density diffuse optical imaging improves brain-specificity and resolution of functional neuroimaging Neuroimage. 47. DOI: 10.1016/S1053-8119(09)71410-7  0.532
2008 Kee HL, Nothdurft R, Muthiah C, Diers JR, Fan D, Ptaszek M, Bocian DF, Lindsey JS, Culver JP, Holten D. Examination of chlorin-bacteriochlorin energy-transfer dyads as prototypes for near-infrared molecular imaging probes. Photochemistry and Photobiology. 84: 1061-72. PMID 18673324 DOI: 10.1111/J.1751-1097.2008.00409.X  0.326
2008 Ntziachristos V, Culver JP, Rice BW. Small-animal optical imaging. Journal of Biomedical Optics. 13: 011001. PMID 18456953 DOI: 10.1117/1.2890838  0.456
2008 Patwardhan SV, Culver JP. Quantitative diffuse optical tomography for small animals using an ultrafast gated image intensifier. Journal of Biomedical Optics. 13: 011009. PMID 18315358 DOI: 10.1117/1.2830656  0.486
2008 Culver J, Akers W, Achilefu S. Multimodality molecular imaging with combined optical and SPECT/PET modalities Journal of Nuclear Medicine. 49: 169-172. PMID 18199608 DOI: 10.2967/Jnumed.107.043331  0.614
2008 Nothdurft RE, Akers SVPW, Achilefu S, Culver JP. Fluorescence lifetime tomography for whole body small animal imaging Biomedical Optics, Biomed 2008. DOI: 10.1364/Biomed.2008.Bwe2  0.566
2008 White BR, Zeff BW, Schlaggar BL, Dehghani H, Culver JP. Phase-encoded retinotopic mapping in humans with DOT Biomedical Optics, Biomed 2008. BME3. DOI: 10.1364/Biomed.2008.Bme3  0.319
2008 Dehghani H, White BR, Zeff BW, Culver JP. Depth sensitivity analysis of high-density imaging arrays for mapping brain function with diffuse optical tomography Biomedical Optics, Biomed 2008. DOI: 10.1364/Biomed.2008.Bmd27  0.554
2008 Achilefu S, Akers W, Edwards WB, Ye Y, Zhang Z, Cheney P, Bloch S, Xu B, Berezin M, Tai YC, Culver JP. Multimodal optical-nuclear molecular imaging of tumors Conference Proceedings - Lasers and Electro-Optics Society Annual Meeting-Leos. 31-32. DOI: 10.1109/LEOS.2008.4688473  0.412
2007 Zeff BW, White BR, Dehghani H, Schlaggar BL, Culver JP. Retinotopic mapping of adult human visual cortex with high-density diffuse optical tomography. Proceedings of the National Academy of Sciences of the United States of America. 104: 12169-74. PMID 17616584 DOI: 10.1073/Pnas.0611266104  0.516
2007 Dehghani H, Carpenter CM, Yalavarthy PK, Pogue BW, Culver JP. Structural a-priori information in near infrared optical tomography Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6431. DOI: 10.1117/12.699547  0.431
2006 Patwardhan SV, Bloch S, Achilefu S, Culver JP. Quantitative small animal fluorescence tomography using an ultrafast gated image intensifier. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 2675-8. PMID 17946130 DOI: 10.1109/IEMBS.2006.259942  0.588
2006 Patwardhan SV, Culver JP. High-frequency, ICCD diffuse optical tomography system for separation of optical properties in small tissue volumes Optics Infobase Conference Papers. DOI: 10.1364/Bio.2006.Wd5  0.313
2006 Bjoern S, Patwardhan SV, Culver JP. The influence of heterogeneous optical properties on fluorescence diffusion tomography of small animals Optics Infobase Conference Papers. DOI: 10.1364/Bio.2006.Tug2  0.423
2006 Culver JP, Zeff BW, Dehghani H. Diffuse optical tomography of visual cortex activation in humans Optics Infobase Conference Papers. DOI: 10.1364/Bio.2006.Md5  0.478
2006 Culver JP, Schlaggar BL, Dehghani H, Zeff BW. Diffuse optical tomography for mapping human brain function 2006 Ieee/Nlm Life Science Systems and Applications Workshop, Lisa 2006. DOI: 10.1109/LSSA.2006.250436  0.371
2005 Culver JP, Siegel AM, Franceschini MA, Mandeville JB, Boas DA. Evidence that cerebral blood volume can provide brain activation maps with better spatial resolution than deoxygenated hemoglobin. Neuroimage. 27: 947-59. PMID 16084112 DOI: 10.1016/J.Neuroimage.2005.05.052  0.452
2005 Patwardhan SV, Bloch SR, Achilefu S, Culver JP. Time-dependent whole-body fluorescence tomography of probe bio-distributions in mice Optics Express. 13: 2564-2571. DOI: 10.1364/Opex.13.002564  0.572
2005 Culver JP, Patwardhan SV, Bloch SR, Achilefu S. Fast scanning fluorescence optical tomography for small animal whole body biodistribution assays Optics Infobase Conference Papers. DOI: 10.1364/Fio.2005.Fmi5  0.609
2005 Durduran T, Yu G, Zhou C, Furuya D, Culver JP, Yodh AG, Greenberg JH. Development of diffuse correlation techniques for non-invasive measurement of cerebral blood flow and oxygen metabolism in rats Journal of Cerebral Blood Flow & Metabolism. 25: S413-S413. DOI: 10.1038/Sj.Jcbfm.9591524.0413  0.456
2004 Graves EE, Culver JP, Ripoll J, Weissleder R, Ntziachristos V. Singular-value analysis and optimization of experimental parameters in fluorescence molecular tomography. Journal of the Optical Society of America. a, Optics, Image Science, and Vision. 21: 231-41. PMID 14763766 DOI: 10.1364/Josaa.21.000231  0.421
2004 Li A, Zhang Q, Culver JP, Miller EL, Boas DA. Reconstructing chromosphere concentration images directly by continuous-wave diffuse optical tomography. Optics Letters. 29: 256-8. PMID 14759043 DOI: 10.1364/Bio.2004.Wb5  0.439
2004 Culver JP, Siegel AM, Stott JJ, Boas DA. Volumetric diffuse optical tomography of brain activity in rat Biosilico. DOI: 10.1364/Bio.2004.Wf1  0.488
2003 Friedberg JS, Skema C, Burdick J, Yodh AG, Carr SR, Culver JP. A novel technique for light delivery through branched or bent anatomic structures. The Journal of Thoracic and Cardiovascular Surgery. 126: 1963-7. PMID 14688713 DOI: 10.1016/S0022-5223(03)01320-5  0.313
2003 Culver JP, Siegel AM, Stott JJ, Boas DA. Volumetric diffuse optical tomography of brain activity. Optics Letters. 28: 2061-3. PMID 14587815 DOI: 10.1364/Ol.28.002061  0.514
2003 Franceschini MA, Fantini S, Thompson JH, Culver JP, Boas DA. Hemodynamic evoked response of the sensorimotor cortex measured noninvasively with near-infrared optical imaging. Psychophysiology. 40: 548-60. PMID 14570163 DOI: 10.1111/1469-8986.00057  0.413
2003 Culver JP, Durduran T, Furuya D, Cheung C, Greenberg JH, Yodh AG. Diffuse optical tomography of cerebral blood flow, oxygenation, and metabolism in rat during focal ischemia. Journal of Cerebral Blood Flow and Metabolism : Official Journal of the International Society of Cerebral Blood Flow and Metabolism. 23: 911-24. PMID 12902835 DOI: 10.1097/01.Wcb.0000076703.71231.Bb  0.422
2003 Siegel AM, Culver JP, Mandeville JB, Boas DA. Temporal comparison of functional brain imaging with diffuse optical tomography and fMRI during rat forepaw stimulation. Physics in Medicine and Biology. 48: 1391-403. PMID 12812454 DOI: 10.1088/0031-9155/48/10/311  0.469
2003 Stott JJ, Culver JP, Arridge SR, Boas DA. Optode positional calibration in diffuse optical tomography. Applied Optics. 42: 3154-62. PMID 12790466 DOI: 10.1364/Ao.42.003154  0.373
2003 Bamett AH, Culver JP, Sorensen AG, Dale A, Boas DA. Robust inference of baseline optical properties of the human head with three-dimensional segmentation from magnetic resonance imaging. Applied Optics. 42: 3095-108. PMID 12790461 DOI: 10.1364/Ao.42.003095  0.432
2003 Culver JP, Choe R, Holboke MJ, Zubkov L, Durduran T, Slemp A, Ntziachristos V, Chance B, Yodh AG. Three-dimensional diffuse optical tomography in the parallel plane transmission geometry: evaluation of a hybrid frequency domain/continuous wave clinical system for breast imaging. Medical Physics. 30: 235-47. PMID 12607841 DOI: 10.1118/1.1534109  0.432
2003 Culver JP, Durduran T, Cheung C, Furuya D, Greenberg JH, Yodh AG. Diffuse optical measurement of hemoglobin and cerebral blood flow in rat brain during hypercapnia, hypoxia and cardiac arrest. Advances in Experimental Medicine and Biology. 510: 293-7. PMID 12580443 DOI: 10.1007/978-1-4615-0205-0_48  0.343
2003 Barnett AH, Culver JP, Sorensen AG, Dale AM, Boas DA. Bayesian estimation of optical properties of the human head via 3D structural MRI Proceedings of Spie - the International Society For Optical Engineering. 5138: 139-147.  0.349
2002 Strangman G, Culver JP, Thompson JH, Boas DA. A quantitative comparison of simultaneous BOLD fMRI and NIRS recordings during functional brain activation. Neuroimage. 17: 719-31. PMID 12377147 DOI: 10.1006/Nimg.2002.1227  0.422
2002 Durduran T, Choe R, Culver JP, Zubkov L, Holboke MJ, Giammarco J, Chance B, Yodh AG. Bulk optical properties of healthy female breast tissue. Physics in Medicine and Biology. 47: 2847-61. PMID 12222850 DOI: 10.1088/0031-9155/47/16/302  0.351
2002 Intes X, Ntziachristos V, Culver JP, Yodh A, Chance B. Projection access order in algebraic reconstruction technique for diffuse optical tomography. Physics in Medicine and Biology. 47: N1-10. PMID 11814231 DOI: 10.1088/0031-9155/47/1/401  0.412
2001 Cheung C, Culver JP, Takahashi K, Greenberg JH, Yodh AG. In vivo cerebrovascular measurement combining diffuse near-infrared absorption and correlation spectroscopies. Physics in Medicine and Biology. 46: 2053-65. PMID 11512610 DOI: 10.1088/0031-9155/46/8/302  0.369
2001 Ripoll J, Ntziachristos V, Culver JP, Pattanayak DN, Yodh AG, Nieto-Vesperinas M. Recovery of optical parameters in multiple-layered diffusive media: Theory and experiments Journal of the Optical Society of America a: Optics and Image Science, and Vision. 18: 821-830. PMID 11318332 DOI: 10.1364/Josaa.18.000821  0.356
2001 Culver JP, Ntziachristos V, Holboke MJ, Yodh AG. Optimization of optode arrangements for diffuse optical tomography: A singular-value analysis Optics Letters. 26: 701-703.  0.342
2000 Li X, Pattanayak DN, Durduran T, Culver JP, Chance B, Yodh AG. Near-field diffraction tomography with diffuse photon density waves. Physical Review. E, Statistical Physics, Plasmas, Fluids, and Related Interdisciplinary Topics. 61: 4295-309. PMID 11088226 DOI: 10.1103/Physreve.61.4295  0.36
1999 Durduran T, Culver J, Holboke M, Li X, Zubkov L, Chance B, Pattanayak D, Yodh A. Algorithms for 3D localization and imaging using near-field diffraction tomography with diffuse light. Optics Express. 4: 247-62. PMID 19396282 DOI: 10.1364/Oe.4.000247  0.416
1999 Durduran T, Culver JP, Holboke MJ, Li XD, Zubkov L, Chance B, Pattanayak DN, Yodh AG. Algorithms for 3D localization and imaging using near-field diffraction tomography with diffuse light Optics Express. 4: 247-262.  0.335
1998 Li XD, Culver JP, Pattanayak DN, Chance B, Yodh AG. Photon density waves imaging with K-space spectrum analysis: clinical studies, background subtraction, and boundary effects Conference On Lasers and Electro-Optics Europe - Technical Digest. 88-89.  0.314
Show low-probability matches.