John A. Nyenhuis - Publications

Affiliations: 
Electrical and Computer Engineering Purdue University, West Lafayette, IN, United States 
Area:
Electronics and Electrical Engineering
Website:
https://engineering.purdue.edu/ECE/People/ptProfile?resource_id=3073

58 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2011 Nyenhuis JA, Miller CR. Calculation of heating of passive implants by the RF electromagnetic field in MRI 2011 30th Ursi General Assembly and Scientific Symposium, Ursigass 2011. DOI: 10.1109/URSIGASS.2011.6051329  0.373
2010 Mohsin SA, Nyenhuis JA, Masood R. INTERACTION OF MEDICAL IMPLANTS WITH THE MRI ELECTROMAGNETIC FIELDS Progress in Electromagnetics Research C. 13: 195-202. DOI: 10.2528/PIERC10041805  0.32
2009 Nyenhuis J, Duan L. An Evaluation of MRI Safety and Compatibility of a Silver-Impregnated Antimicrobial Wound Dressing Journal of the American College of Radiology. 6: 500-505. DOI: 10.1016/J.Jacr.2009.02.013  0.371
2007 Park SM, Kamondetdacha R, Nyenhuis JA. Calculation of MRI-induced heating of an implanted medical lead wire with an electric field transfer function. Journal of Magnetic Resonance Imaging : Jmri. 26: 1278-85. PMID 17969143 DOI: 10.1002/Jmri.21159  0.72
2005 Rezai AR, Baker KB, Tkach JA, Phillips M, Hrdlicka G, Sharan AD, Nyenhuis J, Ruggieri P, Shellock FG, Henderson J. Is magnetic resonance imaging safe for patients with neurostimulation systems used for deep brain stimulation? Neurosurgery. 57: 1056-62; discussion . PMID 16284576 DOI: 10.1227/01.Neu.0000186935.87971.2A  0.357
2005 Baker KB, Tkach J, Hall JD, Nyenhuis JA, Shellock FG, Rezai AR. Reduction of magnetic resonance imaging-related heating in deep brain stimulation leads using a lead management device. Neurosurgery. 57: 392-7; discussion 39. PMID 16234691 DOI: 10.1227/01.Neu.0000176877.26994.0C  0.434
2005 Bailey WH, Nyenhuis JA. Thresholds for 60 Hz magnetic field stimulation of peripheral nerves in human subjects. Bioelectromagnetics. 26: 462-8. PMID 15887260 DOI: 10.1002/Bem.20106  0.526
2005 Baker KB, Nyenhuis JA, Hrdlicka G, Rezai AR, Tkach JA, Shellock FG. Neurostimulation systems: assessment of magnetic field interactions associated with 1.5- and 3-Tesla MR systems. Journal of Magnetic Resonance Imaging : Jmri. 21: 72-7. PMID 15611943 DOI: 10.1002/Jmri.20224  0.492
2005 Amjad A, Kamondetdacha R, Kildishev AV, Park SM, Nyenhuis JA. Power deposition inside a phantom for testing of MRI heating Ieee Transactions On Magnetics. 41: 4185-4187. DOI: 10.1109/TMAG.2005.854840  0.333
2005 Nyenhuis JA, Park SM, Kamondetdacha R, Amjad A, Shellock FG, Rezai AR. MRI and implanted medical devices: Basic interactions with an emphasis on heating Ieee Transactions On Device and Materials Reliability. 5: 467-479. DOI: 10.1109/Tdmr.2005.859033  0.734
2004 So PP, Stuchly MA, Nyenhuis JA. Peripheral nerve stimulation by gradient switching fields in magnetic resonance imaging. Ieee Transactions On Bio-Medical Engineering. 51: 1907-14. PMID 15536892 DOI: 10.1109/TBME.2004.834251  0.451
2004 Shellock FG, Cosendai G, Park SM, Nyenhuis JA. Implantable microstimulator: magnetic resonance safety at 1.5 Tesla. Investigative Radiology. 39: 591-9. PMID 15377938 DOI: 10.1097/01.Rli.0000138090.43450.Ec  0.492
2004 Baker KB, Tkach JA, Nyenhuis JA, Phillips M, Shellock FG, Gonzalez-Martinez J, Rezai AR. Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating. Journal of Magnetic Resonance Imaging : Jmri. 20: 315-20. PMID 15269959 DOI: 10.1002/Jmri.20103  0.415
2004 Rezai AR, Phillips M, Baker KB, Sharan AD, Nyenhuis J, Tkach J, Henderson J, Shellock FG. Neurostimulation system used for deep brain stimulation (DBS): MR safety issues and implications of failing to follow safety recommendations. Investigative Radiology. 39: 300-3. PMID 15087724 DOI: 10.1097/01.Rli.0000124940.02340.Ab  0.411
2004 Kamondetdacha R, Kildishev AV, Nyenhuis JA. Multipole characterization of a magnetic source using a truncated SVD Ieee Transactions On Magnetics. 40: 2176-2178. DOI: 10.1109/Tmag.2004.832365  0.763
2003 Sharan A, Rezai AR, Nyenhuis JA, Hrdlicka G, Tkach J, Baker K, Turbay M, Rugieri P, Phillips M, Shellock FG. MR safety in patients with implanted deep brain stimulation systems (DBS). Acta Neurochirurgica. Supplement. 87: 141-5. PMID 14518542 DOI: 10.1007/978-3-7091-6081-7_30  0.381
2003 Park SM, Nyenhuis JA, Smith CD, Lim EJ, Foster KS, Baker KB, Hrdlicka G, Rezai AR, Ruggieri P, Sharan A, Shellock FG, Stypulkowski PH, Tkach J. Gelled Versus Nongelled Phantom Material for Measurement of MRI-Induced Temperature Increases with Bioimplants Ieee Transactions On Magnetics. 39: 3367-3371. DOI: 10.1109/Tmag.2003.816259  0.415
2003 Kildishev AV, Kamondetdacha R, Nyenhuis JA. Prediction of the magnetic field beyond a rectangular array of sensors Journal of Applied Physics. 93: 7074-7076. DOI: 10.1063/1.1540143  0.758
2003 Kildishev AV, Nyenhuis JA, Zhilichev YN. Extended multipole image of a nonideal permanent magnet rotor Journal of Applied Physics. 93: 8668-8670. DOI: 10.1063/1.1537705  0.522
2003 Nyenhuis JA. Interactions of Medical Implants with the Magnetic Fields in MRI Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 4: 3767-3770.  0.523
2002 Den Boer JA, Bourland JD, Nyenhuis JA, Ham CL, Engels JM, Hebrank FX, Frese G, Schaefer DJ. Comparison of the threshold for peripheral nerve stimulation during gradient switching in whole body MR systems. Journal of Magnetic Resonance Imaging : Jmri. 15: 520-5. PMID 11997892 DOI: 10.1002/Jmri.10110  0.345
2002 Rezai AR, Finelli D, Nyenhuis JA, Hrdlicka G, Tkach J, Sharan A, Rugieri P, Stypulkowski PH, Shellock FG. Neurostimulation systems for deep brain stimulation: in vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla. Journal of Magnetic Resonance Imaging : Jmri. 15: 241-50. PMID 11891968 DOI: 10.1002/Jmri.10069  0.444
2002 Kildishev AV, Nyenhuis JA, Morgan MA. Multipole analysis of an elongated magnetic source by a cylindrical sensor array Ieee Transactions On Magnetics. 38: 2465-2467. DOI: 10.1109/Tmag.2002.803602  0.581
2002 Kamondetdacha R, Nyenhuis JA, Kildishev AV. Effect of noise and localization error of magnetic field sensors on the characterization of complex sources Journal of Applied Physics. 91: 8891-8893. DOI: 10.1063/1.1453333  0.765
2002 Kildishev AV, Nyenhuis JA. Fast magnetic multipole imaging of elementary sources on the disk Journal of Applied Physics. 91: 8721-8723. DOI: 10.1063/1.1447486  0.53
2002 Kildishev AV, Kamondetdacha R, Nyenhuis JA. Prediction of the magnetic field below an axissymetrical planar sensor array with a magnetic source located above the measurement plane Digests of the Intermag Conference 0.779
2002 Kildishev AV, Nyenhuis JA, Morgan MA. Multipole imaging of an elongated magnetic source by a cylindrical sensor array Digests of the Intermag Conference 0.529
2001 Rezai AR, Finelli D, Rugieri P, Tkach J, Nyenhuis JA, Shellock FG. Neurostimulators: potential for excessive heating of deep brain stimulation electrodes during magnetic resonance imaging. Journal of Magnetic Resonance Imaging : Jmri. 14: 488-9. PMID 11599076 DOI: 10.1002/Jmri.1212  0.456
2001 Kildishev AV, Nyenhuis JA. Fast spheroidal multipole imaging of elementary magnetic sources on the axis Journal of Applied Physics. 89: 6716-6718. DOI: 10.1063/1.1358816  0.513
2001 Smith CD, Nyenhuis JA, Foster KS. A comparison of phantom materials used in evaluation of radiofrequency heating of implanted medical devices during MRI Annual Reports of the Research Reactor Institute, Kyoto University. 3: 2311-2314.  0.369
2000 Schaefer DJ, Bourland JD, Nyenhuis JA. Review of patient safety in time-varying gradient fields. Journal of Magnetic Resonance Imaging : Jmri. 12: 20-9. PMID 10931561 DOI: 10.1002/1522-2586(200007)12:1<20::Aid-Jmri3>3.0.Co;2-Y  0.425
2000 Kildishev AV, Nyenhuis JA. Multipole imaging of an elongated magnetic source Ieee Transactions On Magnetics. 36: 3108-3111. DOI: 10.1109/20.908701  0.469
2000 Smith CD, Kildishev AV, Nyenhuis JA, Foster KS, Bourland JD. Interactions of magnetic resonance imaging radio frequency magnetic fields with elongated medical implants Journal of Applied Physics. 87: 6188-6190. DOI: 10.1063/1.372651  0.518
1999 Bourland JD, Nyenhuis JA, Schaefer DJ. Physiologic effects of intense MR imaging gradient fields. Neuroimaging Clinics of North America. 9: 363-77. PMID 10318720  0.318
1999 Kildishev AV, Nyenhuis JA, Dobrodeyev PN, Volokhov SA. Deperming Technology in Large Ferromagnetic Pipes Ieee Transactions On Magnetics. 35: 3907-3909. DOI: 10.1109/20.800704  0.4
1999 Nyenhuis JA, Bourland JD, Foster KS, Graber GP, Kildishev AV, Schaefer DJ. Magnetic stimulation in humans by MRI pulsed gradient fields Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 2: 1074.  0.422
1999 Kildishev AV, Nyenhuis JA, Boyko DL, Dobrodeyev PN, Volokhov A. Application of magnetic signature processing to magnetic center pinpointing in marine vehicles Oceans Conference Record (Ieee). 3: 1532-1536.  0.537
1997 Havel WJ, Nyenhuis JA, Bourland JD, Foster KS, Geddes LA, Graber GP, Waninger MS. Comparison of rectangular and damped sinusoidal db/dt waveforms in magnetic stimulation Ieee Transactions On Magnetics. 33: 4269-4271. DOI: 10.1109/20.619732  0.373
1997 Nyenhuis JA, Bourland JD, Schaefer DJ. Analysis from a stimulation perspective of the field patterns of magnetic resonance imaging gradient coils Journal of Applied Physics. 81: 4314-4316. DOI: 10.1063/1.364759  0.589
1996 Heller JW, Brackmann DE, Tucci DL, Nyenhuis JA, Chou CK. Evaluation of MRI compatibility of the modified nucleus multichannel auditory brainstem and cochlear implants American Journal of Otology. 17: 724-729. PMID 8892568  0.311
1995 Yee OP, Wai WK, Nyenhuis JA, Stroshine RL. Magnetic Field Inhomogeneity Effects On Spin Echo NMR Diffusion Measurements Ieee Transactions On Magnetics. 31: 3584-3586. DOI: 10.1109/20.489577  0.445
1994 Nyenhuis JA, Yee OP. Simulation of nuclear magnetic resonance spin echoes using the Bloch equation: Influence of magnetic field inhomogeneities Journal of Applied Physics. 76: 6909-6911. DOI: 10.1063/1.358112  0.324
1993 Geddes LA, Mouchawar G, Bourland JD, ElAbbady T, Nyenhuis J. Magnetic (eddy-current) electroventilation in the dog. Annals of Biomedical Engineering. 21: 193-7. PMID 8328720 DOI: 10.1007/Bf02368176  0.415
1993 Mouchawar GA, Nyenhuis JA, Bourland JD, Geddes LA, Schaefer DJ, Riehl ME. Magnetic Stimulation of Excitable Tissue: Calculation of Induced Eddy-Currents with a Three-Dimensional Finite-Element Model Ieee Transactions On Magnetics. 29: 3355-3357. DOI: 10.1109/20.281174  0.44
1992 Mouchawar GA, Bourland JD, Nyenhuis JA, Geddes LA, Foster KS, Jones JT, Graber GP. Closed-chest cardiac stimulation with a pulsed magnetic field. Medical & Biological Engineering & Computing. 30: 162-8. PMID 1453781 DOI: 10.1007/Bf02446126  0.554
1991 Mouchawar GA, Bourland JD, Geddes LA, Nyenhuis JA. Magnetic electrophrenic nerve stimulation to produce inspiration. Annals of Biomedical Engineering. 19: 219-21. PMID 2048779 DOI: 10.1007/Bf02368471  0.415
1991 Mouchawar GA, Nyenhuis JA, Bourland JD, Geddes LA. Guidelines for energy-efficient coils: coils designed for magnetic stimulation of the heart. Electroencephalography and Clinical Neurophysiology. Supplement. 43: 255-67. PMID 1773763  0.329
1991 Nyenhuis JA, Mouchawar GA, Bourland JD, Geddes LA. Energy considerations in the magnetic (eddy-current) stimulation of tissues Ieee Transactions On Magnetics. 27: 680-687. DOI: 10.1109/20.101117  0.525
1990 Bourland JD, Mouchawar GA, Nyenhuis JA, Geddes LA, Foster KS, Jones JT, Graber GP. Transchest magnetic (eddy-current) stimulation of the dog heart. Medical & Biological Engineering & Computing. 28: 196-8. PMID 2376996 DOI: 10.1007/Bf02441778  0.434
1990 Nepokoichitsky G, Bettinger T, Fernandez-de-Castro JJ, Nyenhuis JA, Friedlaender FJ. Influence of Bias Field on Dynamic Conversion of Bubbles Ieee Transactions On Magnetics. 26: 2825-2827. DOI: 10.1109/20.104889  0.361
1990 Fedyunin Y, Friedlaender FJ, Nyenhuis JA. Investigation of the Magnetization Process of Domain Walls in an Iron-Garnet Film by Direct Optical Observation of Vertical Bloch Lines Ieee Transactions On Magnetics. 26: 2523-2525. DOI: 10.1109/20.104784  0.423
1990 Mouchawar GA, Nyenhuis JA, Bourland JD, Geddes LA. Influence of Coil Geometry on Localization of the Induced Electric Field in Magnetic (Eddy-Current) Stimulation of Excitable Tissue Ieee Transactions On Magnetics. 26: 1545-1547. DOI: 10.1109/20.104439  0.444
1988 Yanai M, Friedlaender FJ, Nyenhuis JA, Theile J. Resonance effects for different states of a circulating bubble Ieee Transactions On Magnetics. 24: 3054-3056. DOI: 10.1109/20.92332  0.405
1987 Nyenhuis JA, Treece JC, Drynan JM, Sabbagh HA, Sabbagh LD. Data acquisition for experimental verification of aneddy current model for three dimensional inversion Ieee Transactions On Magnetics. 23: 3789-3791. DOI: 10.1109/Tmag.1987.1065508  0.552
1986 Fernandez de Castro J, Matsumoto S, Nyenhuis J, Friedlaender F. Motion of a magnetic bubble in the presence of a modulated bias field: Resonance effects Ieee Transactions On Magnetics. 22: 781-783. DOI: 10.1109/TMAG.1986.1064547  0.393
1986 Nyenhuis JA, Treece JC, Drynan JM, Sabbagh HA. MEASUREMENT OF THE INDUCED MAGNETIC FIELD IN A FLAWED TUBE Review of Progress in Quantitative Nondestructive Evaluation. 5: 241-248.  0.551
1984 Nyenhuis JA, Friedlaender FJ, Matsumoto S. Influence of a modulated bias field on dynamic conversion in a rotating gradient experiment Journal of Applied Physics. 55: 2572-2574. DOI: 10.1063/1.333238  0.344
1983 Nyenhuis JA, Friedlaender FJ, Sato H. Wall states in a bubble moving in a rotating field gradient Ieee Transactions On Magnetics. 19: 1796-1801. DOI: 10.1109/Tmag.1983.1062655  0.421
Show low-probability matches.