James F. Antaki - Publications

Affiliations: 
Carnegie Mellon University, Pittsburgh, PA 
Area:
Biomedical Engineering, Biomechanics Biophysics, Applied Mathematics

174 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2021 Oberdier MT, Antaki JF, Kharlamov A, Jones SC. Closed cranial window rodent model for investigating hemodynamic response to elevated intracranial pressure. Animal Models and Experimental Medicine. 4: 391-397. PMID 34977490 DOI: 10.1002/ame2.12187  0.741
2020 Seese L, Movahedi F, Antaki J, Kilic A, Padman R, Zhang Y, Kanwar M, Burki S, Sciortino C, Keebler M, Hirji S, Kormos R. Delineating Pathways to Death by Multisystem Organ Failure in Patients with a Left Ventricular Assist Device. The Annals of Thoracic Surgery. PMID 32739256 DOI: 10.1016/J.Athoracsur.2020.05.164  0.306
2020 Rowlands G, Antaki J. High-Speed Visualization of Ingested, Ejected, Adherent, and Disintegrated Thrombus in Contemporary Ventricular Assist Devices. Artificial Organs. PMID 32530104 DOI: 10.1111/Aor.13753  0.399
2020 Rowlands GW, Pagani FD, Antaki JF. Classification of the Frequency, Severity, and Propagation of Thrombi in the HeartMate II Left Ventricular Assist Device. Asaio Journal (American Society For Artificial Internal Organs : 1992). PMID 32243265 DOI: 10.1097/Mat.0000000000001151  0.361
2020 Wu W, Zhussupbekov M, Aubry N, Antaki JF, Massoudi M. Simulation of thrombosis in a stenotic microchannel: The effects of vWF-enhanced shear activation of platelets International Journal of Engineering Science. 147: 103206. DOI: 10.1016/J.Ijengsci.2019.103206  0.319
2020 Wu W, Aubry N, Antaki JF, Massoudi M. Simulation of blood flow in a sudden expansion channel and a coronary artery Journal of Computational and Applied Mathematics. 376: 112856. DOI: 10.1016/J.Cam.2020.112856  0.35
2019 Movahedi F, Kormos RL, Lohmueller L, Seese L, Kanwar M, Murali S, Zhang Y, Padman R, Antaki JF. Sequential pattern mining of longitudinal adverse events after Left Ventricular Assist Device implant. Ieee Journal of Biomedical and Health Informatics. PMID 31831453 DOI: 10.1109/Jbhi.2019.2958714  0.332
2019 Wu WT, Aubry N, Antaki JF, Massoudi M. A non-linear fluid suspension model for blood flow. International Journal of Non-Linear Mechanics. 109: 32-39. PMID 31447489 DOI: 10.1016/J.Ijnonlinmec.2018.11.002  0.38
2019 Ranganath NK, Rashidi M, Antaki JF, Phillips KG, Kon ZN, Smith DE, Reyentovich A, Moazami N. Mechanical Blood-Immersed Bearings in Continuous-Flow Rotary Blood Pumps. Asaio Journal (American Society For Artificial Internal Organs : 1992). PMID 31192849 DOI: 10.1097/Mat.0000000000000994  0.393
2019 Kanwar MK, Lohmueller LC, Teuteberg J, Kormos RL, Rogers JG, Benza RL, Lindenfeld J, McIlvennan C, Bailey SH, Murali S, Antaki JF. Risk Assessment in Patients with a Left Ventricular Assist Device Across INTERMACS Profiles Using Bayesian Analysis. Asaio Journal (American Society For Artificial Internal Organs : 1992). PMID 30688695 DOI: 10.1097/Mat.0000000000000910  0.315
2019 Kanwar M, Khoo C, Lohmueller L, Bailey S, Murali S, Antaki J. Predicting Post LVAD Acute Severe Right Heart Failure Using Bayesian Analysis Journal of Heart and Lung Transplantation. 38. DOI: 10.1016/J.Healun.2019.01.907  0.302
2018 Lohmueller LC, Kanwar MK, Bailey S, Murali S, Antaki JF. Retrospective Evaluation of Bayesian Risk Models of LVAD Mortality at a Single Implant Center. Frontiers in Medicine. 5: 277. PMID 30333978 DOI: 10.3389/Fmed.2018.00277  0.315
2018 Kanwar MK, Lohmueller LC, Kormos RL, Teuteberg JJ, Rogers JG, Lindenfeld J, Bailey SH, McIlvennan CK, Benza R, Murali S, Antaki J. A Bayesian Model to Predict Survival After Left Ventricular Assist Device Implantation. Jacc. Heart Failure. PMID 30098967 DOI: 10.1016/J.Jchf.2018.03.016  0.327
2018 Olia SE, Wearden PD, Maul TM, Shankarraman V, Kocyildirim E, Snyder ST, Callahan PM, Kameneva MV, Wagner WR, Borovetz HS, Antaki JF. Preclinical performance of a pediatric mechanical circulatory support device: The PediaFlow ventricular assist device. The Journal of Thoracic and Cardiovascular Surgery. PMID 29807773 DOI: 10.1016/J.Jtcvs.2018.04.062  0.366
2018 Wu W, Aubry N, Antaki J, Massoudi M. Flow of a Dense Suspension Modeled as a Modified Second Grade Fluid Fluids. 3: 55. DOI: 10.3390/Fluids3030055  0.333
2018 Movahedi F, Lohmueller L, Sees L, Zhang Y, Kanwar M, Murali S, Kormos R, Padman R, Antaki J. Pattern Discovery of Most Common Sequential Adverse Events after Left Ventricular Assist Device (LVAD) Implant The Journal of Heart and Lung Transplantation. 37: S382-S383. DOI: 10.1016/J.Healun.2018.01.984  0.309
2017 Blue Martin A, Wu WT, Kameneva MV, Antaki JF. Development of a High-Throughput Magnetic Separation Device for Malaria-Infected Erythrocytes. Annals of Biomedical Engineering. PMID 28924724 DOI: 10.1007/S10439-017-1925-2  0.353
2017 Wu WT, Jamiolkowski MA, Wagner WR, Aubry N, Massoudi M, Antaki JF. Multi-Constituent Simulation of Thrombus Deposition. Scientific Reports. 7: 42720. PMID 28218279 DOI: 10.1038/Srep42720  0.33
2017 Hund S, Kameneva M, Antaki J. A Quasi-Mechanistic Mathematical Representation for Blood Viscosity Fluids. 2: 10. DOI: 10.3390/Fluids2010010  0.336
2017 Wu W, Aubry N, Antaki J, McKoy M, Massoudi M. Heat Transfer in a Drilling Fluid with Geothermal Applications Energies. 10: 1349. DOI: 10.3390/En10091349  0.301
2017 Wu W, Li Y, Aubry N, Massoudi M, Antaki JF. Numerical Simulation of Red Blood Cell-Induced Platelet Transport in Saccular Aneurysms Applied Sciences. 7: 484. DOI: 10.3390/App7050484  0.333
2017 Wu W, Aubry N, Antaki JF, Massoudi M. Flow of a fluid-solid mixture: Normal stress differences and slip boundary condition International Journal of Non-Linear Mechanics. 90: 39-49. DOI: 10.1016/J.Ijnonlinmec.2017.01.004  0.309
2017 Wu W, Zhou Z, Aubry N, Antaki JF, Massoudi M. Heat transfer and flow of a dense suspension between two cylinders International Journal of Heat and Mass Transfer. 112: 597-606. DOI: 10.1016/J.Ijheatmasstransfer.2017.05.017  0.302
2017 Wu W, Aubry N, Massoudi M, Antaki JF. Transport of platelets induced by red blood cells based on mixture theory International Journal of Engineering Science. 118: 16-27. DOI: 10.1016/J.Ijengsci.2017.05.002  0.326
2017 Movahedi F, Lohmueller L, Zhang Y, Padman R, Antaki J. Clinical Journey of Severe Heart Failure Patients after Left Ventricular Assistance Device Implant Journal of Cardiac Failure. 23: S107. DOI: 10.1016/J.Cardfail.2017.07.313  0.316
2016 Wu WT, Yang F, Wu J, Aubry N, Massoudi M, Antaki JF. High fidelity computational simulation of thrombus formation in Thoratec HeartMate II continuous flow ventricular assist device. Scientific Reports. 6: 38025. PMID 27905492 DOI: 10.1038/Srep38025  0.39
2016 Wu WT, Martin AB, Gandini A, Aubry N, Massoudi M, Antaki JF. Design of microfluidic channels for magnetic separation of malaria-infected red blood cells. Microfluidics and Nanofluidics. 20. PMID 27761107 DOI: 10.1007/S10404-016-1707-4  0.361
2016 Loghmanpour NA, Kormos RL, Kanwar MK, Teuteberg JJ, Murali S, Antaki JF. A Bayesian Model to Predict Right Ventricular Failure Following Left Ventricular Assist Device Therapy. Jacc. Heart Failure. PMID 27289403 DOI: 10.1016/J.Jchf.2016.04.004  0.304
2016 Jamiolkowski MA, Pedersen DD, Wu WT, Antaki JF, Wagner WR. Visualization and analysis of biomaterial-centered thrombus formation within a defined crevice under flow. Biomaterials. 96: 72-83. PMID 27156141 DOI: 10.1016/J.Biomaterials.2016.04.022  0.422
2016 Olia SE, Maul TM, Antaki JF, Kameneva MV. Mechanical blood trauma in assisted circulation: sublethal RBC damage preceding hemolysis. The International Journal of Artificial Organs. 0. PMID 27034320 DOI: 10.5301/Ijao.5000478  0.375
2016 Lohmueller LE, Kanwar MK, Loghmanpour NL, Murali S, Antaki JF. An Updated Bayesian Model for Predicting Mortality in Continuous Flow-Left Ventricular Assist Device Patients Journal of Heart and Lung Transplantation. 35. DOI: 10.1016/J.Healun.2016.01.063  0.364
2016 Kim J, Antaki JF, Massoudi M. Computational study of blood flow in microchannels Journal of Computational and Applied Mathematics. 292: 174-187. DOI: 10.1016/J.Cam.2015.06.017  0.349
2016 Wu W, Aubry N, Antaki JF, Massoudi M. Flow of blood in micro-channels: recent results based on mixture theory International Journal of Advances in Engineering Sciences and Applied Mathematics. 9: 40-50. DOI: 10.1007/S12572-016-0173-2  0.342
2015 Shu F, Tian R, Vandenberghe S, Antaki JF. Experimental Study of Micro-Scale Taylor Vortices Within a Co-Axial Mixed-Flow Blood Pump. Artificial Organs. PMID 26713514 DOI: 10.1111/Aor.12663  0.344
2015 Shu F, Vandenberghe S, Brackett J, Antaki JF. Classification of Unsteady Flow Patterns in a Rotodynamic Blood Pump: Introduction of Non-Dimensional Regime Map. Cardiovascular Engineering and Technology. 6: 230-41. PMID 26577357 DOI: 10.1007/S13239-015-0231-0  0.409
2015 Wu WT, Yang F, Antaki JF, Aubry N, Massoudi M. Study of blood flow in several benchmark micro-channels using a two-fluid approach. International Journal of Engineering Science. 95: 49-59. PMID 26240438 DOI: 10.1016/J.Ijengsci.2015.06.004  0.349
2015 Yang F, Kormos RL, Antaki JF. High-speed visualization of disturbed pathlines in axial flow ventricular assist device under pulsatile conditions. The Journal of Thoracic and Cardiovascular Surgery. 150: 938-44. PMID 26208892 DOI: 10.1016/J.Jtcvs.2015.06.049  0.381
2015 Montidoro TA, Burgess JE, Antaki JF. Characterizing Pressure and Flow Rate for Aqueous Immersion Surgery. Surgical Innovation. PMID 25969434 DOI: 10.1177/1553350615585415  0.339
2015 Loghmanpour NA, Kanwar MK, Druzdzel MJ, Benza RL, Murali S, Antaki JF. A new Bayesian network-based risk stratification model for prediction of short-term and long-term LVAD mortality. Asaio Journal (American Society For Artificial Internal Organs : 1992). 61: 313-23. PMID 25710772 DOI: 10.1097/Mat.0000000000000209  0.302
2015 Jamiolkowski MA, Woolley JR, Kameneva MV, Antaki JF, Wagner WR. Real time visualization and characterization of platelet deposition under flow onto clinically relevant opaque surfaces. Journal of Biomedical Materials Research. Part A. 103: 1303-11. PMID 24753320 DOI: 10.1002/Jbm.A.35202  0.348
2014 Loghmanpour NA, Druzdzel MJ, Antaki JF. Cardiac Health Risk Stratification System (CHRiSS): a Bayesian-based decision support system for left ventricular assist device (LVAD) therapy. Plos One. 9: e111264. PMID 25397576 DOI: 10.1371/Journal.Pone.0111264  0.332
2014 Wu WT, Aubry N, Massoudi M, Kim J, Antaki JF. A numerical study of blood flow using mixture theory. International Journal of Engineering Science. 76: 56-72. PMID 24791016 DOI: 10.1016/J.Ijengsci.2013.12.001  0.374
2014 Wang Y, Loghmanpour N, Vandenberghe S, Ferreira A, Keller B, Gorcsan J, Antaki J. Simulation of dilated heart failure with continuous flow circulatory support. Plos One. 9: e85234. PMID 24465511 DOI: 10.1371/Journal.Pone.0085234  0.347
2014 Jahren SE, Ochsner G, Shu F, Amacher R, Antaki JF, Vandenberghe S. Analysis of pressure head-flow loops of pulsatile rotodynamic blood pumps. Artificial Organs. 38: 316-26. PMID 23889536 DOI: 10.1111/Aor.12139  0.344
2014 Loghmanpour NA, Kanwar MK, Benza RL, Murali S, Antaki JF. Development of Predictive Models for Continuous Flow Left Ventricular Assist Device Patients using Bayesian Networks International Journal of Statistics in Medical Research. 3: 423-434. DOI: 10.6000/1929-6029.2014.03.04.11  0.35
2014 Loghmanpour NA, Kanwar MK, Bailey SH, Benza RL, Antaki JF, Murali S. Development of a Novel Predictive Model for Mortality Post Continuous Flow LVAD Implant using Bayesian Networks (BN) Journal of Heart and Lung Transplantation. 33. DOI: 10.1016/J.Healun.2014.01.232  0.306
2013 Menon PG, Antaki JF, Undar A, Pekkan K. Aortic outflow cannula tip design and orientation impacts cerebral perfusion during pediatric cardiopulmonary bypass procedures. Annals of Biomedical Engineering. 41: 2588-602. PMID 23817768 DOI: 10.1007/S10439-013-0857-8  0.315
2013 Amacher R, Weber A, Brinks H, Axiak S, Ferreira A, Guzzella L, Carrel T, Antaki J, Vandenberghe S. Control of ventricular unloading using an electrocardiogram-synchronized Thoratec paracorporeal ventricular assist device. The Journal of Thoracic and Cardiovascular Surgery. 146: 710-7. PMID 23317942 DOI: 10.1016/J.Jtcvs.2012.12.048  0.336
2012 Ruder WC, Pratt ED, Brandy NZ, LaVan DA, LeDuc PR, Antaki JF. Calcium signaling is gated by a mechanical threshold in three-dimensional environments. Scientific Reports. 2: 554. PMID 22870383 DOI: 10.1038/Srep00554  0.708
2012 Massoudi M, Kim J, Antaki JF. Modeling and numerical simulation of blood flow using the Theory of Interacting Continua. International Journal of Non-Linear Mechanics. 47: 506-520. PMID 22611284 DOI: 10.1016/J.Ijnonlinmec.2011.09.025  0.368
2012 Ferreira AL, Yu YC, Arnold DK, Vandenberghe S, Grashow J, Kitano T, Borzelleca D, Antaki JF. In vitro hemodynamic evaluation of ventricular suction conditions of the EVAHEART ventricular assist pump. The International Journal of Artificial Organs. 35: 263-271. PMID 22505201 DOI: 10.5301/Ijao.5000066  0.363
2012 Ruder WC, Pratt ED, Bakhru S, Sitti M, Zappe S, Cheng CM, Antaki JF, LeDuc PR. Three-dimensional microfiber devices that mimic physiological environments to probe cell mechanics and signaling. Lab On a Chip. 12: 1775-9. PMID 22374375 DOI: 10.1039/C2Lc21117C  0.727
2012 Kim J, Massoudi M, Antaki JF, Gandini A. Removal of malaria-infected red blood cells using magnetic cell separators: A computational study. Applied Mathematics and Computation. 218: 6841-6850. PMID 22345827 DOI: 10.1016/J.Amc.2011.12.057  0.318
2012 Wang Y, Simon MA, Bonde P, Harris BU, Teuteberg JJ, Kormos RL, Antaki JF. Decision tree for adjuvant right ventricular support in patients receiving a left ventricular assist device. The Journal of Heart and Lung Transplantation : the Official Publication of the International Society For Heart Transplantation. 31: 140-9. PMID 22168963 DOI: 10.1016/J.Healun.2011.11.003  0.325
2012 Wu J, Antaki JF, Verkaik J, Snyder S, Ricci M. Computational fluid dynamics-based design optimization for an implantable miniature maglev pediatric ventricular assist device Journal of Fluids Engineering, Transactions of the Asme. 134. DOI: 10.1115/1.4005765  0.408
2011 Bachman TN, Bhama JK, Verkaik J, Vandenberghe S, Kormos RL, Antaki JF. In-vitro Evaluation of Ventricular Cannulation for Rotodynamic Cardiac Assist Devices. Cardiovascular Engineering and Technology. 2: 203-211. PMID 22563363 DOI: 10.1007/S13239-011-0050-X  0.391
2011 Maul TM, Kocyildirim E, Johnson CA, Daly AR, Olia SE, Woolley JR, Snyder S, Bengston SG, Kameneva MV, Antaki JF, Wagner WR, Borovetz HS, Wearden PD. In Vitro and In Vivo Performance Evaluation of the Second Developmental Version of the PediaFlow Pediatric Ventricular Assist Device. Cardiovascular Engineering and Technology. 2: 253-262. PMID 22211150 DOI: 10.1007/S13239-011-0061-7  0.393
2011 Gwak KW, Antaki JF, Paden BE, Kang B. Safety-enhanced optimal control of turbodynamic blood pumps. Artificial Organs. 35: 725-32. PMID 21749412 DOI: 10.1111/J.1525-1594.2011.01230.X  0.308
2011 Cleveland JC, Naftel DC, Reece TB, Murray M, Antaki JF, Pagani FD, Kirklin JK. Survival after biventricular assist device implantation: An analysis of the Interagency Registry for Mechanically Assisted Circulatory Support database Journal of Heart and Lung Transplantation. 30: 862-869. PMID 21621423 DOI: 10.1016/J.Healun.2011.04.004  0.309
2011 Johnson CA, Vandenberghe S, Daly AR, Woolley JR, Snyder ST, Verkaik JE, Ye SH, Borovetz HS, Antaki JF, Wearden PD, Kameneva MV, Wagner WR. Biocompatibility assessment of the first generation PediaFlow pediatric ventricular assist device. Artificial Organs. 35: 9-21. PMID 20626737 DOI: 10.1111/J.1525-1594.2010.01023.X  0.371
2011 Antaki JF, Kim J, Singhal A, Burgreen G, Shu F. Aeroelastic analysis of a closing reed of the mouth organ (harmonica) The Journal of the Acoustical Society of America. 130: 2342-2342. DOI: 10.1121/1.3654372  0.329
2011 Wearden P, Maul T, Wu J, Verkaik J, Snyder S, Ricci M, Woodard J, Kameneva M, Wagner W, Antaki J, Borovetz H. 650 The PediaFlow™ Pediatric Ventricular Assist Device The Journal of Heart and Lung Transplantation. 30: S216-S217. DOI: 10.1016/J.Healun.2011.01.663  0.308
2010 Hund SJ, Antaki JF, Massoudi M. On the Representation of Turbulent Stresses for Computing Blood Damage. International Journal of Engineering Science. 48: 1325-1331. PMID 21318093 DOI: 10.1016/J.Ijengsci.2010.09.003  0.34
2010 Zhao R, Marhefka JN, Antaki JF, Kameneva MV. Drag-reducing polymers diminish near-wall concentration of platelets in microchannel blood flow Biorheology. 47: 193-203. PMID 21084744 DOI: 10.3233/Bir-2010-0570  0.345
2010 Antaki JF, Ricci MR, Verkaik JE, Snyder ST, Maul TM, Kim J, Paden DB, Kameneva MV, Paden BE, Wearden PD, Borovetz HS. PediaFlow™ Maglev Ventricular Assist Device: A Prescriptive Design Approach. Cardiovascular Engineering (Dordrecht, Netherlands). 1: 104-121. PMID 20544002 DOI: 10.1007/S13239-010-0011-9  0.385
2010 Wu J, Paden BE, Borovetz HS, Antaki JF. Computational fluid dynamics analysis of blade tip clearances on hemodynamic performance and blood damage in a centrifugal ventricular assist device. Artificial Organs. 34: 402-11. PMID 19832736 DOI: 10.1111/J.1525-1594.2009.00875.X  0.408
2010 Gwak KW, Paden BE, Antaki JF, Ahn IS. Experimental verification of the feasibility of the cardiovascular impedance simulator. Ieee Transactions On Bio-Medical Engineering. 57: 1176-83. PMID 19709951 DOI: 10.1109/Tbme.2009.2030498  0.324
2010 Ruder WC, Hsu C, Chou S, Dawson JT, Gonzalez LM, Antaki JF, LeDuc PR. Micropatterning Biomanufactured Single-Domain Nanoparticles using Self-Assembly to form Artificial Magnetosome Chains Biophysical Journal. 98: 730a. DOI: 10.1016/J.Bpj.2009.12.4001  0.695
2009 Hund SJ, Antaki JF. An extended convection diffusion model for red blood cell-enhanced transport of thrombocytes and leukocytes Physics in Medicine and Biology. 54: 6415-6435. PMID 19809124 DOI: 10.1088/0031-9155/54/20/024  0.328
2009 Shu F, Vandenberghe S, Antaki JF. The importance of dQ/dt on the flow field in a turbodynamic pump with pulsatile flow. Artificial Organs. 33: 757-62. PMID 19775268 DOI: 10.1111/J.1525-1594.2009.00849.X  0.386
2009 Marhefka JN, Zhao R, Wu ZJ, Velankar SS, Antaki JF, Kameneva MV. Drag reducing polymers improve tissue perfusion via modification of the RBC traffic in microvessels Biorheology. 46: 281-292. PMID 19721190 DOI: 10.3233/Bir-2009-0543  0.336
2009 Bhama JK, Bachman TN, Kormos RL, Borovetz H, Antaki JF. Development of an ex vivo ovine ventricular assist device model for intraventricular visualization of the inflow cannula. The Journal of Heart and Lung Transplantation : the Official Publication of the International Society For Heart Transplantation. 28: 860-1. PMID 19632587 DOI: 10.1016/J.Healun.2009.04.027  0.305
2009 Kim NJ, Diao C, Ahn KH, Lee SJ, Kameneva MV, Antaki JF. Parametric study of blade tip clearance, flow rate, and impeller speed on blood damage in rotary blood pump. Artificial Organs. 33: 468-74. PMID 19473143 DOI: 10.1111/J.1525-1594.2009.00754.X  0.392
2009 Shu F, Parks R, Maholtz J, Ash S, Antaki JF. Multimodal flow visualization and optimization of pneumatic blood pump for sorbent hemodialysis system. Artificial Organs. 33: 334-45. PMID 19335410 DOI: 10.1111/J.1525-1594.2009.00724.X  0.378
2009 Ferreira A, Boston JR, Antaki JF. A control system for rotary blood pumps based on suction detection. Ieee Transactions On Bio-Medical Engineering. 56: 656-65. PMID 19272919 DOI: 10.1109/Tbme.2008.2005960  0.378
2009 Gottlieb RK, Shu F, Kameneva MV, Antaki JF, Wu ZJ, Burgreen GW. Liquid crystal shear stress sensor for blood and other opaque viscous fluids Journal of Flow Visualization and Image Processing. 16: 51-71. DOI: 10.1615/Jflowvisimageproc.V16.I1.40  0.303
2009 Simaan MA, Ferreira A, Chen S, Antaki JF, Galati DG. A dynamical state space representation and performance analysis of a feedback-controlled rotary left ventricular assist device Ieee Transactions On Control Systems Technology. 17: 15-28. DOI: 10.1109/Tcst.2008.912123  0.389
2009 Ruder WC, Pratt ED, Sitti M, Leduc PR, Antaki JF. Investigation of calcium mechanotransduction by quasi 3-D microfiber mechanical stimulation of cells Proceedings of the Asme Summer Bioengineering Conference, Sbc2008. 1049-1050.  0.707
2008 Zhao R, Marhefka JN, Shu F, Hund SJ, Kameneva MV, Antaki JF. Micro-flow visualization of red blood cell-enhanced platelet concentration at sudden expansion. Annals of Biomedical Engineering. 36: 1130-41. PMID 18418710 DOI: 10.1007/S10439-008-9494-Z  0.37
2008 Noh MD, Antaki JF, Ricci M, Gardiner J, Paden D, Wu J, Prem E, Borovetz H, Paden BE. Magnetic design for the PediaFlow ventricular assist device. Artificial Organs. 32: 127-35. PMID 18005272 DOI: 10.1111/J.1525-1594.2007.00501.X  0.33
2008 Massoudi M, Antaki JF. An anisotropic constitutive equation for the stress tensor of blood based on mixture theory Mathematical Problems in Engineering. 2008. DOI: 10.1155/2008/579172  0.313
2008 Paden BE, Wu J, Noh MD, Paden D, Ricci M, Snyder S, Maul TM, Webber S, Shu F, Verkaik J, Khanwilkar P, Boston JR, Antaki JF, Keller BB, Kameneva MV, et al. The PediaFlow Pediatric Ventricular Assist Device Ieee Transactions On Biomedical Engineering. 53-54. DOI: 10.1115/Biomed2008-38042  0.331
2008 Drummond A, Antaki J. Virtual fit study of pediatric heart assist system Lecture Notes in Computer Science (Including Subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics). 4650: 71-89. DOI: 10.1007/978-3-540-89430-8_5  0.522
2007 Choi S, Boston JR, Antaki JF. Hemodynamic controller for left ventricular assist device based on pulsatility ratio. Artificial Organs. 31: 114-25. PMID 17298400 DOI: 10.1111/J.1525-1594.2007.00350.X  0.353
2007 Gardiner JM, Wu J, Noh MD, Antaki JF, Snyder TA, Paden DB, Paden BE. Thermal Analysis of the PediaFlow pediatric ventricular assist device. Asaio Journal (American Society For Artificial Internal Organs : 1992). 53: 65-73. PMID 17237651 DOI: 10.1097/01.Mat.0000247156.94587.6C  0.31
2007 Lee SS, Antaki JF, Kameneva MV, Dobbe JG, Hardeman MR, Ahn KH, Lee SJ. Strain hardening of red blood cells by accumulated cyclic supraphysiological stress. Artificial Organs. 31: 80-6. PMID 17209965 DOI: 10.1111/J.1525-1594.2007.00344.X  0.353
2007 Ruder WC, Pratt ED, Brandy NZ, LaVan DA, LeDuc PR, Antaki JF. Stretch-activated calcium signal propagation following mechanical stimulation of focal adhesions Proceedings of the Asme Summer Bioengineering Conference 2007, Sbc 2007. 271-272.  0.698
2006 Uber BE, Webber SA, Morell VO, Antaki JF. Hemodynamic guidelines for design and control of a turbodynamic pediatric ventricular assist device. Asaio Journal (American Society For Artificial Internal Organs : 1992). 52: 471-8. PMID 16883130 DOI: 10.1097/01.Mat.0000227730.00085.36  0.343
2006 Borovetz HS, Badylak S, Boston JR, Johnson C, Kormos R, Kameneva MV, Simaan M, Snyder TA, Tsukui H, Wagner WR, Woolley J, Antaki J, Diao C, Vandenberghe S, Keller B, et al. Towards the development of a pediatric ventricular assist device. Cell Transplantation. 15: S69-74. PMID 16826798 DOI: 10.3727/000000006783982304  0.342
2006 Wearden PD, Morell VO, Keller BB, Webber SA, Borovetz HS, Badylak SF, Boston JR, Kormos RL, Kameneva MV, Simaan M, Snyder TA, Tsukui H, Wagner WR, Antaki JF, Diao C, et al. The PediaFlow pediatric ventricular assist device. Seminars in Thoracic and Cardiovascular Surgery. Pediatric Cardiac Surgery Annual. 92-8. PMID 16638553 DOI: 10.1053/J.Pcsu.2006.02.001  0.343
2006 Vandenberghe S, Segers P, Steendijk P, Meyns B, Dion RA, Antaki JF, Verdonck P. Modeling ventricular function during cardiac assist: does time-varying elastance work? Asaio Journal (American Society For Artificial Internal Organs : 1992). 52: 4-8. PMID 16436883 DOI: 10.1097/01.Mat.0000196525.56523.B8  0.386
2006 Wu J, Antaki JF, Gardiner J, Paden D, Paden BE, Borovetz HS. CFD-BASED OPTIMIZATION OF MAGNETICALLY LEVITATED PEDIAFLOW VENTRICULAR ASSIST DEVICE Asaio Journal. 52: 43A. DOI: 10.1097/00002480-200603000-00186  0.31
2006 Kameneva M, Marascalco P, Snyder T, Antaki J. VALIDITY OF NORMALIZED INDEX OF HEMOLYSIS IN PEDIATRIC MECHANICAL CIRCULATORY ASSIST DEVICES Asaio Journal. 52: 41A. DOI: 10.1097/00002480-200603000-00179  0.308
2005 Vandenberghe S, Segers P, Antaki JF, Meyns B, Verdonck PR. Hemodynamic modes of ventricular assist with a rotary blood pump: continuous, pulsatile, and failure. Asaio Journal (American Society For Artificial Internal Organs : 1992). 51: 711-8. PMID 16340355 DOI: 10.1097/01.Mat.0000179251.40649.45  0.372
2005 Wu J, Antaki JF, Wagner WR, Snyder TA, Paden BE, Borovetz HS. Elimination of adverse leakage flow in a miniature pediatric centrifugal blood pump by computational fluid dynamics-based design optimization. Asaio Journal (American Society For Artificial Internal Organs : 1992). 51: 636-43. PMID 16322730 DOI: 10.1097/01.Mat.0000178966.79876.3D  0.395
2005 Gwak KW, Ricci M, Snyder S, Paden BE, Boston JR, Simaan MA, Antaki JF. In vitro evaluation of multiobjective hemodynamic control of a heart-assist pump. Asaio Journal (American Society For Artificial Internal Organs : 1992). 51: 329-35. PMID 16156294 DOI: 10.1097/01.Mat.0000169122.64794.28  0.367
2005 Wu J, Antaki JF, Snyder TA, Wagner WR, Borovetz HS, Paden BE. Design optimization of blood shearing instrument by computational fluid dynamics. Artificial Organs. 29: 482-9. PMID 15926986 DOI: 10.1111/J.1525-1594.2005.29082.X  0.379
2005 Antaki JF, Wu J, Snyder TA, Wagner WR, Borovetz HS, Paden BE, Diao C. CFD ANALYSIS OF BLADE TIP CLEARANCES ON HEMODYNAMIC PERFORMANCE AND BLOOD DAMAGE IN A MINIATURE PEDIATRIC BLOOD PUMP Asaio Journal. 51: 44A. DOI: 10.1097/00002480-200503000-00172  0.338
2005 Wu J, Antaki JF, Snyder TA, Wagner WR, Borovetz HS, Paden BE, Diao C. ELIMINATION OF REVERSAL FLOW IN BACK CLEARANCE GAPS OF A MINIATURE PEDIATRIC CENTRIFUGALBLOOD PUMP BY CFD Asaio Journal. 51: 40A. DOI: 10.1097/00002480-200503000-00159  0.343
2005 Antaki JF, Diao C, Wu J, Borovetz HS, Wagner W, Snyder T. MICROSCOPIC FLOW VISUALIZATION OF RED BLOOD CELL TRAJECTORY IN THE BLADE TIP AND BACK CLEARANCE OF A MINI BLOOD PUMP Asaio Journal. 51: 6A. DOI: 10.1097/00002480-200503000-00021  0.363
2005 Chen S, Antaki JF, Simaan MA, Boston JR. Physiological control of left ventricular assist devices based on gradient of flow Proceedings of the American Control Conference. 6: 3829-3834.  0.314
2004 Kameneva MV, Burgreen GW, Kono K, Repko B, Antaki JF, Umezu M. Effects of turbulent stresses upon mechanical hemolysis: experimental and computational analysis. Asaio Journal (American Society For Artificial Internal Organs : 1992). 50: 418-23. PMID 15497379 DOI: 10.1097/01.Mat.0000136512.36370.B5  0.38
2004 Song X, Wood HG, Allaire PE, Antaki JF, Olsen DB. Inlet and outlet devices for rotary blood pumps. Artificial Organs. 28: 911-5. PMID 15384997 DOI: 10.1111/J.1525-1594.2004.07399.X  0.408
2004 Smith WA, Allaire P, Antaki J, Butler KC, Kerkhoffs W, Kink T, Loree H, Reul H. Collected nondimensional performance of rotary dynamic blood pumps. Asaio Journal. 50: 25-32. PMID 14763488 DOI: 10.1097/01.Mat.0000104817.39941.9C  0.387
2004 Song X, Throckmorton AL, Wood HG, Antaki JF, Olsen DB. Quantitative evaluation of blood damage in a centrifugal VAD by computational fluid dynamics Journal of Fluids Engineering, Transactions of the Asme. 126: 410-418. DOI: 10.1115/1.1758259  0.4
2004 Gwak KW, Paden BE, Antaki JF. Fluidic operational amplifier for mock circulatory systems Proceedings of the Ieee Conference On Decision and Control. 1: 1061-1068. DOI: 10.1109/Tcst.2006.876624  0.351
2004 Hund S, Antaki JF, Ghattas O. OPTIMAL FLOW PATH DESIGN OF A CANNULA Asaio Journal. 50: 143. DOI: 10.1097/00002480-200403000-00131  0.303
2004 Zhao R, Antaki JF, Wu ZJ, Kameneva MV, Bachman TN. INVESTIGATION OF MICRO-SCALE BLOOD FLOW BEHAVIOR AND SHEAR-INDUCED BLOOD DAMAGE BY CELL TRACKING VELOCIM-ETRY Asaio Journal. 50: 111. DOI: 10.1097/00002480-200403000-00004  0.348
2003 Song X, Throckmorton AL, Wood HG, Antaki JF, Olsen DB. Computational fluid dynamics prediction of blood damage in a centrifugal pump. Artificial Organs. 27: 938-41. PMID 14616540 DOI: 10.1046/J.1525-1594.2003.00026.X  0.407
2003 CHEN C, PADEN B, ANTAKI J, LUDLOW J, BEARNSON G. Optimal Design of Permanent Magnet Bearings with Application to the HeartQuest Ventricular Assist Device Jsme International Journal Series C. 46: 403-408. DOI: 10.1299/Jsmec.46.403  0.31
2003 Boston JR, Antaki JF, Simaan MA. Hierarchical control of heart-assist devices Ieee Robotics and Automation Magazine. 10: 54-64. DOI: 10.1109/Mra.2003.1191711  0.324
2003 Bearnson GB, Jacobs GB, Antaki JF, Paden BE, Long JW. SENSORLESS ANTISUCTION CONTROL AND FLOW ESTIMATION IN AN IMPLANTABLE MAGNETICALLY LEVITATED LVAD Asaio Journal. 49: 223. DOI: 10.1097/00002480-200303000-00326  0.31
2003 Antaki JF, Ludlow JC, Miles SD, Wu J, Burgreen GW, Wu Z, Khanwilkar P, Long J. LOW-PROFILE INLET FOR CENTRIFUGAL BLOOD PUMP Asaio Journal. 49: 154. DOI: 10.1097/00002480-200303000-00054  0.334
2002 Chen C, Paden B, Antaki J, Ludlow J, Paden D, Crowson R, Bearnson G. A magnetic suspension theory and its application to the HeartQuest ventricular assist device Artificial Organs. 26: 947-951. PMID 12406149 DOI: 10.1046/J.1525-1594.2002.07125.X  0.319
2002 Wu J, Ludlow J, Chen C, Paden B, Antaki J. BLADE TIP OPTIMIZATION FOR ROTARY BLOOD PUMP VIA CFD Asaio Journal. 48: 128. DOI: 10.1097/00002480-200203000-00014  0.316
2002 Paden B, Antaki J, Groom N. Mechatronic Design and Optimization of an Artificial Heart Ifac Proceedings Volumes. 35: 301-305. DOI: 10.1016/S1474-6670(17)33957-5  0.357
2001 Burgreen GW, Antaki JF, Wu ZJ, Holmes AJ. Computational fluid dynamics as a development tool for rotary blood pumps. Artificial Organs. 25: 336-40. PMID 11403661 DOI: 10.1046/J.1525-1594.2001.025005336.X  0.411
2001 Yu YC, Boston JR, Simaan MA, Miller PJ, Antaki JF. Pressure-volume relationship of a pulsatile blood pump for ventricular assist device development. Asaio Journal (American Society For Artificial Internal Organs : 1992). 47: 293-301. PMID 11374776 DOI: 10.1097/00002480-200105000-00027  0.34
2001 Baloa LA, Boston JR, Antaki JF. Elastance-based control of a mock circulatory system. Annals of Biomedical Engineering. 29: 244-51. PMID 11310786 DOI: 10.1114/1.1355275  0.318
2001 Griffith BP, Kormos RL, Borovetz HS, Litwak K, Antaki JF, Poirier VL, Butler KC. HeartMate II left ventricular assist system: from concept to first clinical use. The Annals of Thoracic Surgery. 71: S116-20; discussion . PMID 11265845 DOI: 10.1016/S0003-4975(00)02639-4  0.351
2001 Snyder TA, Wu J, Antaki JF, Burgreen GW, Wagner WR. IN VITRO INVESTIGATION OF SHEAR-INDUCED PLATELET ACTIVATION IN AXIAL FLOW VADS Asaio Journal. 47: 137. DOI: 10.1097/00002480-200103000-00147  0.319
2001 Antaki JF, Liu Y, Wu ZJ, Diegel P, Long J. Cannula Design Can Reduce Regurgitant Flow During Vad Stoppage: When A Check Valve Is Not A Check Valve Asaio Journal. 47: 127. DOI: 10.1097/00002480-200103000-00105  0.319
2001 Wu ZJ, Gottlieb RK, Burgreen GW, Holmes JA, Borzelleca DC, Kameneva MV, Griffith BP, Antaki JF. Investigation of fluid dynamics within a miniature mixed flow blood pump Experiments in Fluids. 31: 615-629. DOI: 10.1007/S003480100308  0.373
2000 Akimoto T, Yamazaki K, Litwak P, Litwak KN, Tagusari O, Mori T, Antaki JF, Kameneva MV, Watach MJ, Umezu M, Tomioka J, Kormos RL, Koyanagi H, Griffith BP. Relationship of blood pressure and pump flow in an implantable centrifugal blood pump during hypertension Asaio Journal. 46: 596-599. PMID 11016515 DOI: 10.1097/00002480-200009000-00018  0.344
2000 Akimoto T, Yamazaki K, Litwak P, Litwak KN, Tagusari O, Mori T, Antaki JF, Kameneva MV, Watach MJ, Umezu M, Tomioka J, Kormos RL, Koyanagi H, Griffith BP. Continuously maintaining positive flow avoids endocardial suction of a rotary blood pump with left ventricular bypass Artificial Organs. 24: 606-610. PMID 10971245 DOI: 10.1046/J.1525-1594.2000.06581.X  0.373
2000 Antaki JF, Burgreen GW, Wu ZJ, Borzelleca D, Kameneva MV, Holmes JA, Litwak P, Litwak K, Watach M, Paden BE, Dragnes T, Groom NJ, Griffith BP. Development progress of the University of Pittsburgh streamliner: a mixed flow blood pump with magnetic bearings Asaio Journal. 46: 194. DOI: 10.1097/00002480-200003000-00174  0.417
1999 Wu ZJ, Antaki JF, Burgreen GW, Butler KC, Thomas DC, Griffith BP. Fluid dynamic characterization of operating conditions for continuous flow blood pumps Asaio Journal. 45: 442-449. PMID 10503623 DOI: 10.1097/00002480-199909000-00015  0.375
1999 Sorensen EN, Burgreen GW, Wagner WR, Antaki JF. Computational Simulation of Platelet Deposition and Activation: II. Results for Poiseuille Flow over Collagen Annals of Biomedical Engineering. 27: 449-458. PMID 10468229 DOI: 10.1114/1.201  0.338
1999 Akimoto T, Yamazaki K, Litwak P, Litwak KN, Tagusari O, Mori T, Antaki JF, Kameneva MV, Watach MJ, Umezu M, Tomioka J, Kormos RL, Koyanagi H, Griffith BP. Rotary blood pump flow spontaneously increases during exercise under constant pump speed: Results of a chronic study Artificial Organs. 23: 797-801. PMID 10463510 DOI: 10.1046/J.1525-1594.1999.06426.X  0.368
1999 Burgreen GW, Antaki JF, Wu J, Le Blanc P, Butler KC. A computational and experimental comparison of two outlet stators for the Nimbus LVAD Asaio Journal. 45: 328-333. PMID 10445740 DOI: 10.1097/00002480-199907000-00014  0.353
1999 Kameneva MV, Watach MJ, Litwak P, Antaki JF, Butler KC, Thomas DC, Taylor LP, Borovetz HS, Kormos RL, Griffith BP. Chronic animal health assessment during axial ventricular assistance: Importance of hemorheologic parameters Asaio Journal. 45: 183-188. PMID 10360720 DOI: 10.1097/00002480-199905000-00015  0.37
1999 Wu Z, Antaki J, Ewing B, Kameneva M, Repko B, Thomas D, Putler K. OPERATING RANGE FOR AXIAL FLOW BLOOD PUMP: RELATIONSHIP OF FLUID DYNAMICS, EFFICIENCY, AND HEMOLYSIS Asaio Journal. 45: 165. DOI: 10.1097/00002480-199903000-00183  0.354
1999 Antaki J, Wu J, Boston J, Baloa L, Choi S, Litwak K, Litwak P, Watach M, McCuc L, Thomas D, Butler K. IN CONTINUED SEARCH OF… CONTROL FOR TURBODYNAMIC BLOOD PUMPS Asaio Journal. 45: 164. DOI: 10.1097/00002480-199903000-00181  0.307
1999 Akimoto T, Yamazaki K, Litwak P, Litwak K, Tagusari O, Mori T, Antaki JF, Kameneva M, Watach M, Umezu M, Tomioka J, Kormos RK, Koyanagi H, Griffith BP. THE CENTRIFUGAL BLOOD PUMP WORKS AT THE LOWER PUMP DIFFERENTIAL PRESSURE POINT EVEN UNDER HYPERTENSION Asaio Journal. 45: 163. DOI: 10.1097/00002480-199903000-00175  0.301
1999 Thomas D, Butler K, Taylor L, leBlanc P, Rintoul T, Petersen T, Griffith B, Kormos R, Borovetz H, Litwak P, Litwak K, Kameneva M, Choi S, Burgreen G, Wu J, ... Antaki J, et al. THE NIMBUS-UNIVERSITY OF PITTSBURGH (UOP) AXIAL FLOW LEFT VENTRICULAR ASSIST SYSTEM Asaio Journal. 45: 162. DOI: 10.1097/00002480-199903000-00172  0.348
1998 Curtis AS, Wu ZJ, Kormos RL, Griffith BP, Antaki JF. Novel ventricular apical cannula: In vitro evaluation using transparent, compliant ventricular casts Asaio Journal. 44. PMID 9804523 DOI: 10.1097/00002480-199809000-00078  0.41
1998 Amin DV, Antaki JF, Litwak P, Thomas D, Wu ZJ, Watach M. Induction of ventricular collapse by an axial flow blood pump. Asaio Journal (American Society For Artificial Internal Organs : 1992). 44: M685-90. PMID 9804522 DOI: 10.1097/00002480-199809000-00077  0.37
1998 Thomas DC, Butler KC, Taylor LP, Le Blanc P, Rintoul TC, Petersen TV, Griffith BP, Kormos RL, Borovetz HS, Litwak P, Kameneva MV, Choi S, Burgreen GW, Wu Z, Antaki JF. Progress on development of the Nimbus-University of Pittsburgh axial flow left ventricular assist system Asaio Journal. 44. PMID 9804485 DOI: 10.1097/00002480-199809000-00040  0.348
1998 Yamazaki K, Litwak P, Tagusari O, Mori T, Kono K, Kameneva M, Watach M, Gordon L, Miyagishima M, Tomioka J, Umezu M, Outa E, Antaki JF, Kormos RL, Koyanagi H, et al. An implantable centrifugal blood pump with a recirculating purge system (Cool-Seal System) Artificial Organs. 22: 466-474. PMID 9650667 DOI: 10.1046/J.1525-1594.1998.06156.X  0.375
1998 Tagusari O, Yamazaki K, Litwak P, Antaki JF, Watach M, Gordon LM, Kono K, Mori T, Koyanagi H, Griffith BP, Kormos RL. Effect of pressure-flow relationship of centrifugal pump on in vivo hemodynamics: A consideration for design Artificial Organs. 22: 399-404. PMID 9609348 DOI: 10.1046/J.1525-1594.1998.06157.X  0.34
1998 Yu YC, Boston JR, Simaan MA, Antaki JF. Estimation of systemic vascular bed parameters for artificial heart control Ieee Transactions On Automatic Control. 43: 765-778. DOI: 10.1109/9.679017  0.307
1998 Yeleswarapu KK, Kameneva MV, Rajagopal KR, Antaki JF. The flow of blood in tubes: Theory and experiment Mechanics Research Communications. 25: 257-262. DOI: 10.1016/S0093-6413(98)00036-6  0.501
1997 Yamazaki K, Kormos RL, Litwak P, Tagusari O, Mori T, Antaki JF, Kameneva M, Watach M, Gordon L, Mukuo H, Umezu M, Tomioka J, Outa E, Griffith BP, Koyanagai H. Long term animal experiments with an intraventricular axial flow blood pump Asaio Journal. 43. PMID 9360136 DOI: 10.1097/00002480-199709000-00074  0.392
1997 Yamazaki K, Litwak P, Kormos RL, Mori T, Tagusari O, Antaki JF, Kameneva M, Watach M, Gordon L, Umezu M, Tomioka J, Koyanagi H, Griffith BP. An implantable centrifugal blood pump for long term circulatory support Asaio Journal. 43. PMID 9360134 DOI: 10.1097/00002480-199709000-00072  0.382
1997 Kameneva MV, Antaki JF, Yeleswarapu KK, Watach MJ, Griffith BP, Borovetz HS. Plasma protective effect on red blood cells exposed to mechanical stress Asaio Journal. 43. PMID 9360109 DOI: 10.1097/00002480-199703000-00186  0.303
1997 Yamazaki K, Mori T, Tomioka J, Litwak P, Antaki JF, Tagusari O, Koyanagi H, Griffith BP, Kormos RL. The cool seal system: A practical solution to the shaft seal problem and heat related complications with implantable rotary blood pumps Asaio Journal. 43. PMID 9360108 DOI: 10.1097/00002480-199709000-00046  0.334
1997 Kameneva MV, Borovetz HS, Antaki JF, Litwak P, Federspiel WJ, Kormos RL, Griffith BP. Effect of perfluorochemical emulsion on hemorheology and shear induced blood trauma: Possible mechanisms and future applications Advances in Experimental Medicine and Biology. 411: 383-390. PMID 9269453 DOI: 10.1007/978-1-4615-5865-1_49  0.346
1997 Macha M, Litwak P, Yamazaki K, Kameneva M, Kerrigan JP, Antaki JF, Butler KC, Thomas DC, Taylor LP, Kormos RL, Griffith BP, Borovetz HS. Survival for up to six months in calves supported with an implantable axial flow ventricular assist device. Asaio Journal (American Society For Artificial Internal Organs : 1992). 43: 311-5. PMID 9242945 DOI: 10.1097/00002480-199707000-00009  0.4
1997 Butler K, Thomas D, Antaki J, Borovetz H, Griffith B, Kameneva M, Kormos R, Litwak P. Development of the Nimbus/Pittsburgh axial flow left ventricular assist system. Artificial Organs. 21: 602-10. PMID 9212925 DOI: 10.1111/J.1525-1594.1997.Tb03708.X  0.408
1997 Thomas D, Butler K, Taylor L, Blanc Pl, Griffith B, Kormos R, Borovetz H, Litwak P, Kameneva M, Choi S, Burgreen G, Wu J, Antaki J. Continued Development Of The Nimbus-Pittsburgh (Uop) Axial Flow Left Ventricular Assist System Asaio Journal. 43: 52. DOI: 10.1097/00002480-199703000-00190  0.359
1997 Yamazaki K, Litwak P, Kormos RL, Tagusari O, Antaki JF, Kameneva M, Watach M, Gordon L, Mori T, Umezu M, Tomioka J, Koyanagi H, Griffith BP. A TOTALLY IMPLANTABLE CENTRIFUGAL BLOOD PUMP FOR LONG-TERM CIRCULATORY SUPPORT Asaio Journal. 43: 51. DOI: 10.1097/00002480-199703000-00185  0.306
1997 Burgreen GW, Antaki JF, Griffith BP. COMPUTATIONAL FLUID DYNAMICS BASED DESIGN OPTIMIZATION OF AN AXIAL FLOW BLOOD PUMP Asaio Journal. 43: 46. DOI: 10.1097/00002480-199703000-00166  0.356
1997 Yamazaki K, Mori T, Tomioka J, Antaki JF, Litwak P, Tagusari O, Griffith BP, Koyanagi H, Kormos RL. The “Cool Seal” Concept: A Low-Temperature Mechanical Seal with Recirculating Purge System for Rotary Blood Pumps Asaio Journal. 43: 337-343. DOI: 10.1007/978-4-431-65921-1_49  0.345
1996 Kerrigan JP, Yamazaki K, Meyer RK, Mori T, Otake Y, Outa E, Umezu M, Borovetz HS, Kormos RL, Griffith BP, Koyanagi H, Antaki JF. High-Resolution Fluorescent Particle-Tracking Flow Visualization within an Intraventricular Axial Flow Left Ventricular Assist Device. Artificial Organs. 20: 534-540. PMID 28868728 DOI: 10.1111/J.1525-1594.1996.Tb04476.X  0.378
1996 Konishi H, Antaki JF, Amin DV, Boston JR, Kerrigan JP, Mandarino WA, Litwak P, Yamazaki K, Macha M, Butler KC, Borovetz HS, Kormos RL. Controller for an Axial Flow Blood Pump. Artificial Organs. 20: 618-620. PMID 28868686 DOI: 10.1111/J.1525-1594.1996.Tb04491.X  0.354
1996 Konishi H, Yland MJ, Brown M, Yamazaki K, Macha M, Konishi R, Kerrigan JP, Zhang S, Randhawa PS, Antaki JF, Fuse K, Kormos RL. Effect of pulsatility and hemodynamic power on recovery of renal function. Asaio Journal (American Society For Artificial Internal Organs : 1992). 42: M720-3. PMID 8944975 DOI: 10.1097/00002480-199609000-00082  0.321
1996 Burgreen GW, Antaki JF, Griffith BP. A design improvement strategy for axial blood pumps using computational fluid dynamics Asaio Journal. 42. PMID 8944906 DOI: 10.1097/00002480-199609000-00010  0.38
1996 Konishi H, Antaki JF, Litwak P, Kameneva M, Yamazaki K, Macha M, Kerrigan JP, Mandarino WA, Butler KC, Borovetz HS, Kormos RL. Long-term animal survival with an implantable axial flow pump as a left ventricular assist device. Artificial Organs. 20: 124-7. PMID 8712955 DOI: 10.1111/J.1525-1594.1996.Tb00713.X  0.399
1996 Butler K, Taylor L, Thomas D, Litwak P, Antaki J, Kameneva M, Macha M, Borovetz H, Kormos R, Griffith B. An Axial Flow Pump-Based Lvas For Bridge To Cardiac Transplantation Asaio Journal. 42: 124. DOI: 10.1097/00002480-199603000-00412  0.309
1996 Macha M, Litwak P, Yamazaki K, Kameneva M, Kerrigan J, Antaki J, Borovetz H, Butler K, Thomas D, Taylor L, Kormos R, Griffith B. SIX MONTH SURVIVAL IN A CALF SUPPORTED WITH AN IMPLANTABLE AXIAL FLOW VENTRICULAR ASSIST DEVICE Asaio Journal. 42: 40. DOI: 10.1097/00002480-199603000-00146  0.359
1996 Yamazaki K, Kormos RL, Tagusari O, Litwak P, Mori T, Antaki JF, Kameneva M, Watach M, Gordon L, Mukuo H, Umezu M, Tomioka J, Outa E, Griffith B, Koyanagi H. In Vivo Evaluation of an Intraventricular Axial Flow Blood Pump Asaio Journal. 42: 396-400. DOI: 10.1007/978-4-431-65921-1_59  0.395
1995 Kameneva MV, Antaki JF, Borovetz HS, Griffith BP, Butler KC, Yelleswarapu KK, Watach MJ, Kormos RL. Mechanisms of red blood cell trauma in assisted circulation. Rheologic similarities of red blood cell transformations due to natural aging and mechanical stress Asaio Journal. 41. PMID 8573845 DOI: 10.1097/00002480-199507000-00051  0.353
1995 Yamazaki K, Kormos R, Mori T, Umezu M, Kameneva M, Antaki J, Outa E, Litwak P, Kerrigan J, Tomczak J. An intraventricular axial flow blood pump integrated with a bearing purge system. Asaio Journal (American Society For Artificial Internal Organs : 1992). 41: M327-32. PMID 8573818 DOI: 10.1097/00002480-199507000-00024  0.427
1995 Antaki JF, Dennis TJ, Konishi H, Brown ME, Maher TR, Tomczak JP, Kerrigan JP, Kormos RL. An improved left ventricular cannula for chronic dynamic blood pump support. Artificial Organs. 19: 671-5. PMID 8572971 DOI: 10.1111/J.1525-1594.1995.Tb02400.X  0.385
1995 Antaki JF, Ghattas O, Burgreen GW, He B. Computational flow optimization of rotary blood pump components Artificial Organs. 19: 608-615. PMID 8572960 DOI: 10.1111/J.1525-1594.1995.Tb02389.X  0.388
1995 Yeleswarapu KK, Antaki JF, Kameneva MV, Rajagopal KR. A mathematical model for shear-induced hemolysis. Artificial Organs. 19: 576-82. PMID 8572955 DOI: 10.1111/J.1525-1594.1995.Tb02384.X  0.483
1994 Kameneva MV, Antaki JF, Watach MJ, Borovetz HS, Kormos RL. Heparin effect on red blood cell aggregation Biorheology. 31: 297-304. PMID 8729489 DOI: 10.3233/Bir-1994-31307  0.305
1994 Kameneva MV, Antaki JF, Konishi H, Whalen JJ, Kerrigan JP, Watach MJ, Kormos RL, Griffith BP, Borovetz HS. Effect of perfluorochemical emulsion on blood trauma and hemorheology. Asaio Journal (American Society For Artificial Internal Organs : 1992). 40: M576-9. PMID 8555580 DOI: 10.1097/00002480-199407000-00064  0.371
1994 Konishi H, Antaki JF, Boston JR, Kerrigan JP, Mandarino WA, Yamazaki K, Oe M, Litwak P, Borovetz HS, Butler KC. Dynamic systemic vascular resistance in a sheep supported with a Nimbus AxiPump. Asaio Journal (American Society For Artificial Internal Organs : 1992). 40: M299-302. PMID 8555528 DOI: 10.1097/00002480-199407000-00012  0.369
1994 Kameneva MV, Antaki JF, Butler KC, Watach MJ, Kormos RL, Griffith BP, Borovetz HS. A sheep model for the study of hemorheology with assisted circulation: Effect of an axial flow blood pump Asaio Journal. 40: 959-963. PMID 7858332 DOI: 10.1097/00002480-199410000-00009  0.385
1993 Kerrigan JP, Shaffer FD, Maher TR, Dennis TJ, Borovetz HS, Antaki JF. Fluorescent image tracking velocimetry of the Nimbus AxiPump. Asaio Journal (American Society For Artificial Internal Organs : 1992). 39: M639-43. PMID 8268616 DOI: 10.1097/00002480-199307000-00100  0.378
1993 Antaki JF, Butler KC, Kormos RL, Kawai A, Konishi H, Kerrigan JP, Borovetz HS, Maher TR, Kameneva MV, Griffith BP. In vivo evaluation of the Nimbus axial flow ventricular assist system. Criteria and methods. Asaio Journal (American Society For Artificial Internal Organs : 1992). 39: M231-6. PMID 8268534 DOI: 10.1097/00002480-199307000-00016  0.377
1992 Butler KC, Maher TR, Borovetz HS, Kormos RL, Antaki JF, Kameneva M, Griffith BP, Zerbe T, Schaffer FD. Development of an axial flow blood pump LVAS. Asaio Journal (American Society For Artificial Internal Organs : 1992). 38: M296-300. PMID 1457869 DOI: 10.1097/00002480-199207000-00041  0.384
1990 Kormos RL, Borovetz HS, Gasior T, Antaki JF, Armitage JM, Pristas JM, Hardesty RL, Griffith BP. Experience with univentricular support in mortally ill cardiac transplant candidates The Annals of Thoracic Surgery. 49: 261-272. PMID 2306148 DOI: 10.1016/0003-4975(90)90148-Y  0.304
Show low-probability matches.