Year |
Citation |
Score |
2020 |
Gu Z, Taschereau R, Vu NT, Prout DL, Lee J, Chatziioannou AF. Performance evaluation of HiPET, a high sensitivity and high resolution preclinical PET tomograph. Physics in Medicine and Biology. PMID 31935693 DOI: 10.1088/1361-6560/Ab6B44 |
0.557 |
|
2018 |
Gu Z, Taschereau R, Vu N, Prout DL, Silverman RW, Lee J, Chatziioannou AF. Performance evaluation of G8, a high sensitivity benchtop preclinical PET/CT tomograph. Journal of Nuclear Medicine : Official Publication, Society of Nuclear Medicine. PMID 29903933 DOI: 10.2967/Jnumed.118.208827 |
0.544 |
|
2015 |
Chang YC, Berry-Pusey B, Yasin R, Vu N, Maraglia B, Chatziioannou AX, Tsao TC. An Automated Mouse Tail Vascular Access System by Vision and Pressure Feedback. Ieee/Asme Transactions On Mechatronics : a Joint Publication of the Ieee Industrial Electronics Society and the Asme Dynamic Systems and Control Division. 20: 1616-1623. PMID 26478693 DOI: 10.1109/Tmech.2014.2360886 |
0.677 |
|
2013 |
Gu Z, Taschereau R, Vu NT, Wang H, Prout DL, Silverman RW, Bai B, Stout DB, Phelps ME, Chatziioannou AF. NEMA NU-4 performance evaluation of PETbox4, a high sensitivity dedicated PET preclinical tomograph. Physics in Medicine and Biology. 58: 3791-814. PMID 23666034 DOI: 10.1088/0031-9155/58/11/3791 |
0.526 |
|
2013 |
Dooraghi AA, Vu NT, Silverman RW, Farrell R, Shah KS, Wang J, Heath JR, Chatziioannou AF. Betabox: a beta particle imaging system based on a position sensitive avalanche photodiode. Physics in Medicine and Biology. 58: 3739-53. PMID 23656911 DOI: 10.1088/0031-9155/58/11/3739 |
0.427 |
|
2012 |
Wang H, Stout DB, Taschereau R, Gu Z, Vu NT, Prout DL, Chatziioannou AF. MARS: a mouse atlas registration system based on a planar x-ray projector and an optical camera. Physics in Medicine and Biology. 57: 6063-77. PMID 22968224 DOI: 10.1088/0031-9155/57/19/6063 |
0.419 |
|
2012 |
Gu Z, Taschereau R, Vu NT, Wang H, Prout DL, Silverman RW, Stout DB, Phelps ME, Chatziioannou AF. Design and initial performance of PETbox4, a high sensitivity preclinical imaging tomograph Ieee Nuclear Science Symposium Conference Record. 2328-2331. DOI: 10.1109/NSSMIC.2011.6153873 |
0.311 |
|
2011 |
Vu NT, Yu ZT, Comin-Anduix B, Søndergaard JN, Silverman RW, Chang CY, Ribas A, Tseng HR, Chatziioannou AF. A beta-camera integrated with a microfluidic chip for radioassays based on real-time imaging of glycolysis in small cell populations. Journal of Nuclear Medicine : Official Publication, Society of Nuclear Medicine. 52: 815-21. PMID 21536929 DOI: 10.2967/Jnumed.110.078725 |
0.339 |
|
2011 |
Zhang H, Bao Q, Vu NT, Silverman RW, Taschereau R, Berry-Pusey BN, Douraghy A, Rannou FR, Stout DB, Chatziioannou AF. Performance evaluation of PETbox: a low cost bench top preclinical PET scanner. Molecular Imaging and Biology : Mib : the Official Publication of the Academy of Molecular Imaging. 13: 949-61. PMID 20812031 DOI: 10.1007/S11307-010-0413-Y |
0.638 |
|
2010 |
Zhang H, Vu NT, Bao Q, Silverman RW, Berry-Pusey BN, Douraghy A, Williams DA, Rannou FR, Stout DB, Chatziioannou AF. Performance Characteristics of BGO Detectors for a Low Cost Preclinical PET Scanner. Ieee Transactions On Nuclear Science. 57: 1038-1044. PMID 21165154 DOI: 10.1109/Tns.2010.2046753 |
0.616 |
|
2009 |
Zhang H, Vu NT, Bao Q, Silverman RW, Stout DB, Taschereau R, Berry-Pusey BN, Williams DA, Douraghy A, Rannou FR, Phelps ME, Chatziioannou AF. Performance evaluation of PETbox: A low cost bench top PET scanner dedicated to high throughput preclinical imaging Ieee Nuclear Science Symposium Conference Record. 4013-4016. DOI: 10.1109/NSSMIC.2009.5401918 |
0.649 |
|
2008 |
Yu ZTF, Vu NT, Shu CJ, Kamei KI, Silverman RW, Witte ON, Radu CG, Chatziioannou AF, Tseng HR. Design and characterization of a biomedical device capable of pico-CI level beta detection for the study of cell metabolism Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 280-283. DOI: 10.1109/MEMSYS.2008.4443647 |
0.345 |
|
2007 |
Cho JS, Vu NT, Yu ZT, Silverman RW, Tseng HR, Chatziioannou AF. Optimization of design parameters of a prototype CCD-based lens-coupled imaging system for the detection of beta particles in a microfluidic chip Ieee Nuclear Science Symposium Conference Record. 6: 4615-4619. DOI: 10.1109/NSSMIC.2007.4437137 |
0.304 |
|
2007 |
Vu NT, Yu ZTF, Silverman RW, Farrell R, Shah KS, Tseng HR, Chatziioannou AF. Performance of an integrated microfluidic chip and position sensitive APD for the detection of beta emitting probes in cell cultures Ieee Nuclear Science Symposium Conference Record. 6: 4057-4061. DOI: 10.1109/NSSMIC.2007.4437019 |
0.301 |
|
2007 |
Cho JS, Vu NT, Chung YH, Yu ZT, Silverman RW, Taschereau R, Tseng HR, Chatziioannou AF. Detection of beta particles in a microfluidic chip using a scintillator and CCD Ieee Nuclear Science Symposium Conference Record. 4: 1977-1981. DOI: 10.1109/NSSMIC.2006.354301 |
0.309 |
|
2006 |
Vu NT, Silverman RW, Chatziioannou AF. Preliminary performance of optical PET (OPET) detectors for the detection of visible light photons Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 569: 563-566. DOI: 10.1016/J.Nima.2006.08.138 |
0.446 |
|
Show low-probability matches. |