Year |
Citation |
Score |
2023 |
Khan MMR, Fan Y, Dawant BM, Noble JH. Cochlear Implant Fold Detection in Intra-operative CT Using Weakly Supervised Multi-task Deep Learning. Medical Image Computing and Computer-Assisted Intervention : Miccai ... International Conference On Medical Image Computing and Computer-Assisted Intervention. 14228: 249-259. PMID 38515783 DOI: 10.1007/978-3-031-43996-4_24 |
0.716 |
|
2023 |
Smetak MR, Fernando SJ, O'Malley MR, Bennett ML, Haynes DS, Wootten CT, Virgin FW, Dwyer RT, Dawant BM, Noble JH, Labadie RF. Electrode array positioning after cochlear reimplantation from single manufacturer. Cochlear Implants International. 24: 273-281. PMID 37489512 DOI: 10.1080/14670100.2023.2179756 |
0.677 |
|
2023 |
Banalagay RA, Labadie RF, Noble JH. Validation of active shape model techniques for intracochlear anatomy segmentation in computed tomography images. Journal of Medical Imaging (Bellingham, Wash.). 10: 044003. PMID 37476645 DOI: 10.1117/1.JMI.10.4.044003 |
0.432 |
|
2023 |
Berg KA, Chen C, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Effects of the Number of Channels and Channel Stimulation Rate on Speech Recognition and Sound Quality Using Precurved Electrode Arrays. American Journal of Audiology. 1-14. PMID 37249492 DOI: 10.1044/2023_AJA-22-00032 |
0.676 |
|
2023 |
Smetak MR, Riojas KE, Whittenbarger N, Noble JH, Labadie RF. Dynamic Behavior and Insertional Forces of a Precurved Electrode Using the Pull-Back Technique in a Fresh Microdissected Cochlea. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. PMID 36728107 DOI: 10.1097/MAO.0000000000003812 |
0.359 |
|
2022 |
Bratu EL, Sunderhaus LW, Berg KA, Dwyer RT, Labadie RF, Gifford RH, Noble JH. Activation region overlap visualization for image-guided cochlear implant programming. Biomedical Physics & Engineering Express. 9. PMID 36594887 DOI: 10.1088/2057-1976/ac9aba |
0.452 |
|
2022 |
Cleary M, Bernstein JGW, Stakhovskaya OA, Noble J, Kolberg E, Jensen KK, Hoa M, Kim HJ, Goupell MJ. The Relationship Between Interaural Insertion-Depth Differences, Scalar Location, and Interaural Time-Difference Processing in Adult Bilateral Cochlear-Implant Listeners. Trends in Hearing. 26: 23312165221129165. PMID 36379607 DOI: 10.1177/23312165221129165 |
0.472 |
|
2022 |
Gifford RH, Sunderhaus LW, Holder JT, Berg KA, Dawant BM, Noble JH, Perkins E, Camarata S. Speech recognition as a function of the number of channels for pediatric cochlear implant recipients. Jasa Express Letters. 2: 094403. PMID 36182337 DOI: 10.1121/10.0013428 |
0.68 |
|
2022 |
Gifford RH, Sunderhaus LW, Dawant BM, Labadie RF, Noble JH. Cochlear implant spectral bandwidth for optimizing electric and acoustic stimulation (EAS). Hearing Research. 108584. PMID 35985964 DOI: 10.1016/j.heares.2022.108584 |
0.693 |
|
2022 |
Berg KA, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Speech recognition as a function of the number of channels for Mid-Scala electrode array recipients. The Journal of the Acoustical Society of America. 152: 67. PMID 35931512 DOI: 10.1121/10.0012163 |
0.7 |
|
2022 |
Goupell MJ, Noble JH, Phatak SA, Kolberg E, Cleary M, Stakhovskaya OA, Jensen KK, Hoa M, Kim HJ, Bernstein JGW. Computed-Tomography Estimates of Interaural Mismatch in Insertion Depth and Scalar Location in Bilateral Cochlear-Implant Users. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 43: 666-675. PMID 35761459 DOI: 10.1097/MAO.0000000000003538 |
0.454 |
|
2022 |
Perkins EL, Labadie RF, O'Malley M, Bennett M, Noble JH, Haynes DS, Gifford R. The Relation of Cochlear Implant Electrode Array Type and Position on Continued Hearing Preservation. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 43: e634-e640. PMID 35709407 DOI: 10.1097/MAO.0000000000003547 |
0.463 |
|
2022 |
Dorman MF, Natale SC, Noble JH, Zeitler DM. Upward Shifts in the Internal Representation of Frequency Can Persist Over a 3-Year Period for Cochlear Implant Patients Fit With a Relatively Short Electrode Array. Frontiers in Human Neuroscience. 16: 863891. PMID 35399353 DOI: 10.3389/fnhum.2022.863891 |
0.369 |
|
2021 |
Wang J, Su D, Fan Y, Chakravorti S, Noble JH, Dawant BM. Atlas-based Segmentation of Intracochlear Anatomy in Metal Artifact Affected CT Images of the Ear with Co-trained Deep Neural Networks. Medical Image Computing and Computer-Assisted Intervention : Miccai ... International Conference On Medical Image Computing and Computer-Assisted Intervention. 12904: 14-23. PMID 35360271 DOI: 10.1007/978-3-030-87202-1_2 |
0.673 |
|
2021 |
Fan Y, Banalagay RA, Cass ND, Noble JH, Tawfik KO, Labadie RF, Dawant BM. Automatic Segmentation of Intracochlear Anatomy in MR Images Using a Weighted Active Shape Model. Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual International Conference. 2021: 3573-3576. PMID 34892011 DOI: 10.1109/EMBC46164.2021.9630332 |
0.657 |
|
2021 |
Fan Y, Zhang D, Banalagay R, Wang J, Noble JH, Dawant BM. Hybrid active shape and deep learning method for the accurate and robust segmentation of the intracochlear anatomy in clinical head CT and CBCT images. Journal of Medical Imaging (Bellingham, Wash.). 8: 064002. PMID 34853805 DOI: 10.1117/1.JMI.8.6.064002 |
0.654 |
|
2021 |
Bernstein JGW, Jensen KK, Stakhovskaya OA, Noble JH, Hoa M, Kim HJ, Shih R, Kolberg E, Cleary M, Goupell MJ. Interaural place-of-stimulation mismatch estimates using CT scans and binaural perception, but not pitch, are consistent in cochlear-implant users. The Journal of Neuroscience : the Official Journal of the Society For Neuroscience. PMID 34725189 DOI: 10.1523/JNEUROSCI.0359-21.2021 |
0.485 |
|
2021 |
Labadie RF, Riojas K, Von Wahlde K, Mitchell J, Bruns T, Webster R, Dawant B, Fitzpatrick JM, Noble J. Clinical Implementation of Second-generation Minimally Invasive Image-guided Cochlear Implantation Surgery. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 42: 702-705. PMID 33967246 DOI: 10.1097/MAO.0000000000003025 |
0.648 |
|
2021 |
Berg KA, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Speech recognition as a function of the number of channels for an array with large inter-electrode distances. The Journal of the Acoustical Society of America. 149: 2752. PMID 33940865 DOI: 10.1121/10.0004244 |
0.695 |
|
2021 |
Morrel WG, Manzoor NF, Dawant BM, Noble JH, Labadie RF. Intraoperative Correction of Cochlear Implant Electrode Translocation. Audiology & Neuro-Otology. 1-5. PMID 33915536 DOI: 10.1159/000515684 |
0.753 |
|
2020 |
Liu Z, Cakir A, Noble JH. Auditory Nerve Fiber Health Estimation Using Patient Specific Cochlear Implant Stimulation Models. Simulation and Synthesis in Medical Imaging : ... International Workshop, Sashimi ..., Held in Conjunction With Miccai ..., Proceedings. Sashimi (Workshop). 12417: 184-194. PMID 33884380 DOI: 10.1007/978-3-030-59520-3_19 |
0.329 |
|
2020 |
Bratu E, Dwyer R, Noble J. A Graph-Based Method for Optimal Active Electrode Selection in Cochlear Implants. Medical Image Computing and Computer-Assisted Intervention : Miccai ... International Conference On Medical Image Computing and Computer-Assisted Intervention. 12263: 34-43. PMID 33884379 DOI: 10.1007/978-3-030-59716-0_4 |
0.512 |
|
2020 |
Banalagay RA, Labadie RF, Chakravorti S, Noble JH. Insertion Depth for Optimized Positioning of Precurved Cochlear Implant Electrodes. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. PMID 32569133 DOI: 10.1097/Mao.0000000000002726 |
0.533 |
|
2020 |
Khan MMR, Labadie RF, Noble JH. Preoperative prediction of angular insertion depth of lateral wall cochlear implant electrode arrays. Journal of Medical Imaging (Bellingham, Wash.). 7: 031504. PMID 32509912 DOI: 10.1117/1.Jmi.7.3.031504 |
0.578 |
|
2020 |
Berg KA, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Speech recognition with cochlear implants as a function of the number of channels: Effects of electrode placement. The Journal of the Acoustical Society of America. 147: 3646. PMID 32486813 DOI: 10.1121/10.0001316 |
0.731 |
|
2020 |
Gafford J, Freeman M, Fichera L, Noble J, Labadie R, Webster RJ. Eyes in Ears: A Miniature Steerable Digital Endoscope for Trans-Nasal Diagnosis of Middle Ear Disease. Annals of Biomedical Engineering. PMID 32458223 DOI: 10.1007/S10439-020-02518-9 |
0.358 |
|
2020 |
Morrel WG, Riojas KE, Webster RJ, Noble JH, Labadie RF. Custom mastoid-fitting templates to improve cochlear implant electrode insertion trajectory. International Journal of Computer Assisted Radiology and Surgery. PMID 32409852 DOI: 10.1007/S11548-020-02193-0 |
0.573 |
|
2020 |
Dorman MF, Natale SC, Baxter L, Zeitler DM, Carlson ML, Lorens A, Skarzynski H, Peters JPM, Torres JH, Noble JH. Approximations to the Voice of a Cochlear Implant: Explorations With Single-Sided Deaf Listeners. Trends in Hearing. 24: 2331216520920079. PMID 32339072 DOI: 10.1177/2331216520920079 |
0.505 |
|
2020 |
Morrel WG, Holder JT, Dawant BM, Noble JH, Labadie RF. Effect of Scala Tympani Height on Insertion Depth of Straight Cochlear Implant Electrodes. Otolaryngology--Head and Neck Surgery : Official Journal of American Academy of Otolaryngology-Head and Neck Surgery. 194599820904941. PMID 32093543 DOI: 10.1177/0194599820904941 |
0.74 |
|
2020 |
Carton FX, Chabanas M, Le Lann F, Noble JH. Automatic segmentation of brain tumor resections in intraoperative ultrasound images using U-Net. Journal of Medical Imaging (Bellingham, Wash.). 7: 031503. PMID 32090137 DOI: 10.1117/1.Jmi.7.3.031503 |
0.338 |
|
2020 |
Zhang D, Wang J, Noble JH, Dawant BM. HeadLocNet: Deep convolutional neural networks for accurate classification and multi-landmark localization of head CTs. Medical Image Analysis. 61: 101659. PMID 32062157 DOI: 10.1016/J.Media.2020.101659 |
0.766 |
|
2019 |
Labadie RF, Schefano AD, Holder JT, Dwyer RT, Rivas A, O'Malley MR, Noble JH, Dawant BM. Use of intraoperative CT scanning for quality control assessment of cochlear implant electrode array placement. Acta Oto-Laryngologica. 1-6. PMID 31859576 DOI: 10.1080/00016489.2019.1698768 |
0.741 |
|
2019 |
Dorman MF, Cook Natale S, Baxter L, Zeitler DM, Carlson ML, Noble JH. Cochlear Place of Stimulation Is One Determinant of Cochlear Implant Sound Quality. Audiology & Neuro-Otology. 24: 264-269. PMID 31661682 DOI: 10.1159/000503217 |
0.499 |
|
2019 |
Berg K, Noble J, Dawant B, Dwyer R, Labadie R, Richards V, Gifford R. Musical Sound Quality as a Function of the Number of Channels in Modern Cochlear Implant Recipients. Frontiers in Neuroscience. 13: 999. PMID 31607846 DOI: 10.3389/Fnins.2019.00999 |
0.687 |
|
2019 |
Zhang D, Banalagay R, Wang J, Zhao Y, Noble JH, Dawant BM. Two-level Training of a 3d U-Net for Accurate Segmentation of the Intra-cochlear Anatomy in Head CTs with Limited Ground Truth Training Data. Proceedings of Spie--the International Society For Optical Engineering. 10949. PMID 31571720 DOI: 10.1117/12.2512529 |
0.852 |
|
2019 |
Wang J, Noble JH, Dawant BM. Metal artifact reduction for the segmentation of the intra cochlear anatomy in CT images of the ear with 3D-conditional GANs. Medical Image Analysis. 58: 101553. PMID 31525672 DOI: 10.1016/J.Media.2019.101553 |
0.758 |
|
2019 |
Dorman MF, Natale SC, Zeitler DM, Baxter L, Noble JH. Looking for Mickey Mouse™ But Finding a Munchkin: The Perceptual Effects of Frequency Upshifts for Single-Sided Deaf, Cochlear Implant Patients. Journal of Speech, Language, and Hearing Research : Jslhr. 1-7. PMID 31415186 DOI: 10.1044/2019_Jslhr-H-18-0389 |
0.47 |
|
2019 |
Riggs WJ, Dwyer RT, Holder JT, Mattingly JK, Ortmann A, Noble JH, Dawant BM, Valenzuela CV, O'Connell BP, Harris MS, Litvak LM, Koka K, Buchman CA, Labadie RF, Adunka OF. Intracochlear Electrocochleography: Influence of Scalar Position of the Cochlear Implant Electrode on Postinsertion Results. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 40: e503-e510. PMID 31083085 DOI: 10.1097/Mao.0000000000002202 |
0.772 |
|
2019 |
Chakravorti S, Noble JH, Gifford RH, Dawant BM, O'Connell BP, Wang J, Labadie RF. Further Evidence of the Relationship Between Cochlear Implant Electrode Positioning and Hearing Outcomes. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 40: 617-624. PMID 31083083 DOI: 10.1097/Mao.0000000000002204 |
0.772 |
|
2019 |
Berg KA, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Speech recognition as a function of the number of channels in perimodiolar electrode recipients. The Journal of the Acoustical Society of America. 145: 1556. PMID 31067952 DOI: 10.1121/1.5092350 |
0.675 |
|
2019 |
Riggs WJ, Dwyer RT, Holder JT, Mattingly JK, Ortmann A, Noble JH, Dawant BM, Valenzuela CV, O'Connell BP, Harris MS, Litvak LM, Koka K, Buchman CA, Labadie RF, Adunka OF. Intracochlear Electrocochleography: Influence of Scalar Position of the Cochlear Implant Electrode on Postinsertion Results. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. PMID 31033920 DOI: 10.1097/MAO.0000000000002202 |
0.751 |
|
2019 |
Chakravorti S, Noble JH, Gifford RH, Dawant BM, O'Connell BP, Wang J, Labadie RF. Further Evidence of the Relationship Between Cochlear Implant Electrode Positioning and Hearing Outcomes. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. PMID 30889115 DOI: 10.1097/MAO.0000000000002204 |
0.751 |
|
2019 |
Berg KA, Noble JH, Dawant B, Dwyer R, Labadie R, Gifford RH. Effect of number of channels and speech coding strategy on speech recognition in mid-scala electrode recipients The Journal of the Acoustical Society of America. 145: 1796-1797. DOI: 10.1121/1.5101574 |
0.65 |
|
2018 |
Zhang D, Wang J, Noble JH, Dawant BM. Accurate Detection of Inner Ears in Head CTs Using a Deep Volume-to-Volume Regression Network with False Positive Suppression and a Shape-Based Constraint. Medical Image Computing and Computer-Assisted Intervention : Miccai ... International Conference On Medical Image Computing and Computer-Assisted Intervention. 11073: 703-711. PMID 33733250 DOI: 10.1007/978-3-030-00937-3_80 |
0.746 |
|
2018 |
Noble JH, Labadie RF, Dawant BM. Automatic classification of cochlear implant electrode cavity positioning. Medical Image Computing and Computer-Assisted Intervention : Miccai ... International Conference On Medical Image Computing and Computer-Assisted Intervention. 11073: 47-54. PMID 31573001 DOI: 10.1007/978-3-030-00937-3_6 |
0.775 |
|
2018 |
Zhang D, Noble JH, Dawant BM. Automatic Detection of the Inner Ears in Head CT Images Using Deep Convolutional Neural Networks. Proceedings of Spie--the International Society For Optical Engineering. 10574. PMID 31007337 DOI: 10.1117/12.2293383 |
0.75 |
|
2018 |
Zhao Y, Labadie RF, Dawant BM, Noble JH. Validation of automatic cochlear implant electrode localization techniques using . Journal of Medical Imaging (Bellingham, Wash.). 5: 035001. PMID 30840722 DOI: 10.1117/1.Jmi.5.3.035001 |
0.864 |
|
2018 |
Wang J, Zhao Y, Noble JH, Dawant BM. Conditional Generative Adversarial Networks for Metal Artifact Reduction in CT Images of the Ear. Medical Image Computing and Computer-Assisted Intervention : Miccai ... International Conference On Medical Image Computing and Computer-Assisted Intervention. 11070: 3-11. PMID 30693351 DOI: 10.1007/978-3-030-00928-1_1 |
0.828 |
|
2018 |
Morrel WG, Jayawardena ADL, M Amberg S, Dawant BM, Noble JH, Labadie RF. Revision surgery following minimally invasive image-guided cochlear implantation. The Laryngoscope. PMID 30582165 DOI: 10.1002/Lary.27636 |
0.716 |
|
2018 |
Zhao Y, Chakravorti S, Labadie RF, Dawant BM, Noble JH. Automatic graph-based method for localization of cochlear implant electrode arrays in clinical CT with sub-voxel accuracy. Medical Image Analysis. 52: 1-12. PMID 30468968 DOI: 10.1016/J.Media.2018.11.005 |
0.862 |
|
2018 |
Zhao Y, Dawant BM, Labadie RF, Noble JH. Automatic localization of closely-spaced cochlear implant electrode arrays in clinical CTs. Medical Physics. PMID 30218461 DOI: 10.1002/Mp.13185 |
0.867 |
|
2018 |
Koka K, Riggs WJ, Dwyer R, Holder JT, Noble JH, Dawant BM, Ortmann A, Valenzuela CV, Mattingly JK, Harris MM, O'Connell BP, Litvak LM, Adunka OF, Buchman CA, Labadie RF. Intra-Cochlear Electrocochleography During Cochear Implant Electrode Insertion Is Predictive of Final Scalar Location. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 39: e654-e659. PMID 30113557 DOI: 10.1097/Mao.0000000000001906 |
0.764 |
|
2018 |
Labadie RF, Noble JH. Preliminary Results With Image-guided Cochlear Implant Insertion Techniques. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 39: 922-928. PMID 29995013 DOI: 10.1097/Mao.0000000000001850 |
0.609 |
|
2018 |
Braga GPB, Gebrim E, Balachandran R, Noble J, Labadie R, Bento RF. Evaluation of the Facial Recess and Cochlea on the Temporal Bone of Stillbirths regarding the Percutaneous Cochlear Implant. International Archives of Otorhinolaryngology. 22: 260-265. PMID 29983766 DOI: 10.1055/S-0037-1606612 |
0.487 |
|
2018 |
Holder JT, Kessler DM, Noble JH, Gifford RH, Labadie RF. Prevalence of Extracochlear Electrodes: Computerized Tomography Scans, Cochlear Implant Maps, and Operative Reports. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 39: e325-e331. PMID 29738386 DOI: 10.1097/Mao.0000000000001818 |
0.576 |
|
2018 |
Gifford RH, Noble JH, Camarata SM, Sunderhaus LW, Dwyer RT, Dawant BM, Dietrich MS, Labadie RF. The Relationship Between Spectral Modulation Detection and Speech Recognition: Adult Versus Pediatric Cochlear Implant Recipients. Trends in Hearing. 22: 2331216518771176. PMID 29716437 DOI: 10.1177/2331216518771176 |
0.673 |
|
2018 |
Zhang D, Zhao Y, Noble JH, Dawant BM. Selecting electrode configurations for image-guided cochlear implant programming using template matching. Journal of Medical Imaging (Bellingham, Wash.). 5: 021202. PMID 29250568 DOI: 10.1117/1.Jmi.5.2.021202 |
0.863 |
|
2018 |
Stakhovskaya OA, Bernstein JG, Noble JH, Jensen KK, Hoa M, Kim HJ, Goupell M. Does electrode placement affect the interaural-time-difference acuity in bilateral cochlear-implant listeners? The Journal of the Acoustical Society of America. 144: 1710-1710. DOI: 10.1121/1.5067591 |
0.545 |
|
2017 |
Zhang D, Liu Y, Noble JH, Dawant BM. Localizing landmark sets in head CTs using random forests and a heuristic search algorithm for registration initialization. Journal of Medical Imaging (Bellingham, Wash.). 4: 044007. PMID 29250565 DOI: 10.1117/1.Jmi.4.4.044007 |
0.755 |
|
2017 |
Chakravorti S, Bussey BJ, Zhao Y, Dawant BM, Labadie RF, Noble JH. Cochlear implant phantom for evaluating computed tomography acquisition parameters. Journal of Medical Imaging (Bellingham, Wash.). 4: 045002. PMID 29181432 DOI: 10.1117/1.Jmi.4.4.045002 |
0.862 |
|
2017 |
Wang J, Liu Y, Noble JH, Dawant BM. Automatic selection of landmarks in T1-weighted head MRI with regression forests for image registration initialization. Journal of Medical Imaging (Bellingham, Wash.). 4: 044005. PMID 29181430 DOI: 10.1117/1.Jmi.4.4.044005 |
0.654 |
|
2017 |
Wang J, Liu Y, Noble JH, Dawant BM. Automatic selection of landmarks in T1-weighted head MRI with regression forests for image registration initialization. Proceedings of Spie--the International Society For Optical Engineering. 10133. PMID 28781410 DOI: 10.1117/12.2254769 |
0.65 |
|
2017 |
Cakir A, Dwyer RT, Noble JH. Evaluation of a high-resolution patient-specific model of the electrically stimulated cochlea. Journal of Medical Imaging (Bellingham, Wash.). 4: 025003. PMID 28630884 DOI: 10.1117/1.Jmi.4.2.025003 |
0.531 |
|
2017 |
McBrayer KL, Wanna GB, Dawant BM, Balachandran R, Labadie RF, Noble JH. Resection planning for robotic acoustic neuroma surgery. Journal of Medical Imaging (Bellingham, Wash.). 4: 025002. PMID 28612038 DOI: 10.1117/1.Jmi.4.2.025002 |
0.648 |
|
2017 |
O'Connell BP, Holder JT, Dwyer RT, Gifford RH, Noble JH, Bennett ML, Rivas A, Wanna GB, Haynes DS, Labadie RF. Intra- and Postoperative Electrocochleography May Be Predictive of Final Electrode Position and Postoperative Hearing Preservation. Frontiers in Neuroscience. 11: 291. PMID 28611574 DOI: 10.3389/Fnins.2017.00291 |
0.538 |
|
2017 |
McRackan TR, Noble JH, Wilkinson EP, Mills D, Dietrich MS, Dawant BM, Gifford RH, Labadie RF. Implementation of Image-Guided Cochlear Implant Programming at a Distant Site. Otolaryngology--Head and Neck Surgery : Official Journal of American Academy of Otolaryngology-Head and Neck Surgery. 194599817698435. PMID 28374640 DOI: 10.1177/0194599817698435 |
0.766 |
|
2017 |
Wang J, Dawant BM, Labadie RF, Noble JH. Retrospective Evaluation of a Technique for Patient-Customized Placement of Precurved Cochlear Implant Electrode Arrays. Otolaryngology--Head and Neck Surgery : Official Journal of American Academy of Otolaryngology-Head and Neck Surgery. 194599817697298. PMID 28374623 DOI: 10.1177/0194599817697298 |
0.777 |
|
2017 |
O'Connell BP, Hunter JB, Haynes DS, Holder JT, Dedmon MM, Noble JH, Dawant BM, Wanna GB. Insertion depth impacts speech perception and hearing preservation for lateral wall electrodes. The Laryngoscope. PMID 28304096 DOI: 10.1002/Lary.26467 |
0.713 |
|
2017 |
Rivas A, Cakir A, Hunter JB, Labadie RF, Zuniga MG, Wanna GB, Dawant BM, Noble JH. Automatic Cochlear Duct Length Estimation for Selection of Cochlear Implant Electrode Arrays. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. PMID 28146009 DOI: 10.1097/Mao.0000000000001329 |
0.768 |
|
2017 |
Chakravorti S, Bussey BJ, Zhao Y, Dawant BM, Labadie RF, Noble JH. A cochlear implant phantom for evaluating CT acquisition parameters Proceedings of Spie. 10135. DOI: 10.1117/12.2255742 |
0.865 |
|
2017 |
Zhao Y, Dawant BM, Noble JH. Automatic localization of cochlear implant electrodes in CTs with a limited intensity range Proceedings of Spie. 10133. DOI: 10.1117/12.2254569 |
0.862 |
|
2016 |
Zhang D, Liu Y, Noble JH, Dawant BM. Automatic localization of landmark sets in head CT images with regression forests for image registration initialization. Proceedings of Spie--the International Society For Optical Engineering. 9784. PMID 28503017 DOI: 10.1117/12.2216925 |
0.737 |
|
2016 |
Zuniga MG, Rivas A, Hedley-Williams A, Gifford RH, Dwyer R, Dawant BM, Sunderhaus LW, Hovis KL, Wanna GB, Noble JH, Labadie RF. Tip Fold-over in Cochlear Implantation: Case Series. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. PMID 27918363 DOI: 10.1097/Mao.0000000000001283 |
0.732 |
|
2016 |
Cakir A, Labadie RF, Zuniga MG, Dawant BM, Noble JH. Evaluation of Rigid Cochlear Models for Measuring Cochlear Implant Electrode Position. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. PMID 27755453 DOI: 10.1097/Mao.0000000000001245 |
0.766 |
|
2016 |
Zhao Y, Dawant BM, Noble JH. Automatic selection of the active electrode set for image-guided cochlear implant programming. Journal of Medical Imaging (Bellingham, Wash.). 3: 035001. PMID 27704031 DOI: 10.1117/1.Jmi.3.3.035001 |
0.854 |
|
2016 |
Hunter JB, O'Connell BP, Wang J, Chakravorti S, Makowiec K, Carlson ML, Dawant B, McCaslin DL, Noble JH, Wanna GB. Correlation of Superior Canal Dehiscence Surface Area With Vestibular Evoked Myogenic Potentials, Audiometric Thresholds, and Dizziness Handicap. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 37: 1104-1110. PMID 27525621 DOI: 10.1097/Mao.0000000000001126 |
0.591 |
|
2016 |
O'Connell BP, Hunter JB, Gifford RH, Rivas A, Haynes DS, Noble JH, Wanna GB. Electrode Location and Audiologic Performance After Cochlear Implantation: A Comparative Study Between Nucleus CI422 and CI512 Electrode Arrays. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 37: 1032-1035. PMID 27525618 DOI: 10.1097/Mao.0000000000001140 |
0.516 |
|
2016 |
O'Connell BP, Cakir A, Hunter JB, Francis DO, Noble JH, Labadie RF, Zuniga G, Dawant BM, Rivas A, Wanna GB. Electrode Location and Angular Insertion Depth Are Predictors of Audiologic Outcomes in Cochlear Implantation. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. PMID 27348391 DOI: 10.1097/Mao.0000000000001125 |
0.744 |
|
2016 |
Sweeney AD, Hunter JB, Carlson ML, Rivas A, Bennett ML, Gifford RH, Noble JH, Haynes DS, Labadie RF, Wanna GB. Durability of Hearing Preservation after Cochlear Implantation with Conventional-Length Electrodes and Scala Tympani Insertion. Otolaryngology--Head and Neck Surgery : Official Journal of American Academy of Otolaryngology-Head and Neck Surgery. PMID 26908553 DOI: 10.1177/0194599816630545 |
0.572 |
|
2016 |
Noble JH, Hedley-Williams AJ, Sunderhaus L, Dawant BM, Labadie RF, Camarata SM, Gifford RH. Initial Results With Image-guided Cochlear Implant Programming in Children. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 37: e63-9. PMID 26756157 DOI: 10.1097/Mao.0000000000000909 |
0.737 |
|
2016 |
Davis TJ, Zhang D, Gifford RH, Dawant BM, Labadie RF, Noble JH. Relationship Between Electrode-to-Modiolus Distance and Current Levels for Adults With Cochlear Implants. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 37: 31-37. PMID 26649603 DOI: 10.1097/Mao.0000000000000896 |
0.729 |
|
2016 |
Cakir A, Dawant BM, Noble JH. Evaluation of a μcT-based electro-anatomical cochlear implant model Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9786. DOI: 10.1117/12.2217275 |
0.743 |
|
2016 |
Zhang D, Liu Y, Noble JH, Dawant BM. Automatic localization of landmark sets in head CT images with regression forests for image registration initialization Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9784. DOI: 10.1117/12.2216925 |
0.713 |
|
2016 |
McBrayer KL, Wanna GB, Dawant BM, Balachandran R, Labadie RF, Noble JH. Resection planning for robotic acoustic neuroma surgery Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9786. DOI: 10.1117/12.2216867 |
0.648 |
|
2015 |
Noble JH, Dawant BM. Automatic graph-based localization of cochlear implant electrodes in CT. Medical Image Computing and Computer-Assisted Intervention : Miccai ... International Conference On Medical Image Computing and Computer-Assisted Intervention. 9350: 152-159. PMID 27158686 DOI: 10.1007/978-3-319-24571-3_19 |
0.768 |
|
2015 |
Labadie RF, Noble JH, Hedley-Williams AJ, Sunderhaus LW, Dawant BM, Gifford RH. Results of Postoperative, CT-based, Electrode Deactivation on Hearing in Prelingually Deafened Adult Cochlear Implant Recipients. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. PMID 26719955 DOI: 10.1097/Mao.0000000000000926 |
0.77 |
|
2015 |
Wanna GB, Noble JH, Gifford RH, Dietrich MS, Sweeney AD, Zhang D, Dawant BM, Rivas A, Labadie RF. Impact of Intrascalar Electrode Location, Electrode Type, and Angular Insertion Depth on Residual Hearing in Cochlear Implant Patients: Preliminary Results. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 36: 1343-8. PMID 26176556 DOI: 10.1097/Mao.0000000000000829 |
0.765 |
|
2015 |
Zhao Y, Dawant BM, Noble JH. Automatic electrode configuration selection for image-guided cochlear implant programming Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9415. DOI: 10.1117/12.2081473 |
0.859 |
|
2015 |
Ali H, Noble JH, Gifford RH, Labadie RF, Dawant BM, Hansen JHL, Tobey E. Image-guided customization of frequency-place mapping in cochlear implants Icassp, Ieee International Conference On Acoustics, Speech and Signal Processing - Proceedings. 2015: 5843-5847. DOI: 10.1109/ICASSP.2015.7179092 |
0.365 |
|
2015 |
Wanna GB, Noble JH, Gifford RH, Dietrich MS, Sweeney AD, Zhang D, Dawant BM, Rivas A, Labadie RF. Impact of Intrascalar Electrode Location, Electrode Type, and Angular Insertion Depth on Residual Hearing in Cochlear Implant Patients: Preliminary Results Otology and Neurotology. 36: 1343-1348. DOI: 10.1097/MAO.0000000000000829 |
0.464 |
|
2014 |
Noble JH, Gifford RH, Hedley-Williams AJ, Dawant BM, Labadie RF. Clinical evaluation of an image-guided cochlear implant programming strategy. Audiology & Neuro-Otology. 19: 400-11. PMID 25402603 DOI: 10.1159/000365273 |
0.775 |
|
2014 |
Zhao Y, Dawant BM, Labadie RF, Noble JH. Automatic localization of cochlear implant electrodes in CT. Medical Image Computing and Computer-Assisted Intervention : Miccai ... International Conference On Medical Image Computing and Computer-Assisted Intervention. 17: 331-8. PMID 25333135 DOI: 10.1007/978-3-319-10404-1_42 |
0.867 |
|
2014 |
Reda FA, Noble JH, Labadie RF, Dawant BM. An artifact-robust, shape library-based algorithm for automatic segmentation of inner ear anatomy in post-cochlear-implantation CT. Proceedings of Spie--the International Society For Optical Engineering. 9034: 90342V. PMID 25076827 DOI: 10.1117/12.2043260 |
0.795 |
|
2014 |
Liu Y, Konrad PE, Neimat JS, Tatter SB, Yu H, Datteri RD, Landman BA, Noble JH, Pallavaram S, Dawant BM, D'Haese PF. Multisurgeon, multisite validation of a trajectory planning algorithm for deep brain stimulation procedures. Ieee Transactions On Bio-Medical Engineering. 61: 2479-87. PMID 24833411 DOI: 10.1109/Tbme.2014.2322776 |
0.789 |
|
2014 |
Wanna GB, Noble JH, Carlson ML, Gifford RH, Dietrich MS, Haynes DS, Dawant BM, Labadie RF. Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes. The Laryngoscope. 124: S1-7. PMID 24764083 DOI: 10.1002/Lary.24728 |
0.754 |
|
2014 |
McRackan TR, Carlson ML, Reda FA, Noble JH, Rivas A. Bifid facial nerve in congenital stapes footplate fixation. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 35: e199-201. PMID 24751739 DOI: 10.1097/Mao.0000000000000274 |
0.368 |
|
2014 |
Reda FA, McRackan TR, Labadie RF, Dawant BM, Noble JH. Automatic segmentation of intra-cochlear anatomy in post-implantation CT of unilateral cochlear implant recipients. Medical Image Analysis. 18: 605-15. PMID 24650801 DOI: 10.1016/j.media.2014.02.001 |
0.777 |
|
2014 |
Balachandran R, Tsai BS, Ramachandra T, Noble JH, Dawant BM, Labadie RF, Bennett ML. Minimally invasive image-guided access for drainage of petrous apex lesions: a case report. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 35: 649-55. PMID 24622019 DOI: 10.1097/Mao.0000000000000328 |
0.66 |
|
2014 |
Balachandran R, Reda FA, Noble JH, Blachon GS, Dawant BM, Fitzpatrick JM, Labadie RF. Minimally invasive image-guided cochlear implantation for pediatric patients: clinical feasibility study. Otolaryngology--Head and Neck Surgery : Official Journal of American Academy of Otolaryngology-Head and Neck Surgery. 150: 631-7. PMID 24449796 DOI: 10.1177/0194599813519050 |
0.744 |
|
2014 |
Labadie RF, Balachandran R, Noble JH, Blachon GS, Mitchell JE, Reda FA, Dawant BM, Fitzpatrick JM. Minimally invasive image-guided cochlear implantation surgery: first report of clinical implementation. The Laryngoscope. 124: 1915-22. PMID 24272427 DOI: 10.1002/Lary.24520 |
0.739 |
|
2014 |
Levo H, Kentala E, Rasku J, PyykkF I, Stevens MN, Baudhuin JE, Hullar TE, Rask-Andersen H, Atturo F, Barbara M, Colletti L, Shannon RV, Colletti V, Kuo C, Lien C, ... ... Noble JH, et al. Contents Vol. 19, 2014 Audiology and Neuro-Otology. 19. DOI: 10.1159/000371361 |
0.544 |
|
2014 |
Turok RL, Labadie RF, Wanna GB, Dawant BM, Noble JH. Cochlear implant simulator for surgical technique analysis Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9036. DOI: 10.1117/12.2044205 |
0.749 |
|
2013 |
Stayman JW, Dang H, Otake Y, Zbijewski W, Noble J, Dawant B, Labadie R, Carey JP, Siewerdsen JH. Overcoming Nonlinear Partial Volume Effects in Known-Component Reconstruction of Cochlear Implants. Proceedings of Spie--the International Society For Optical Engineering. 8668: 86681L. PMID 24949189 DOI: 10.1117/12.2007945 |
0.726 |
|
2013 |
Pelosi S, Noble JH, Dawant BM, Labadie RF. Analysis of intersubject variations in intracochlear and middle ear surface anatomy for cochlear implantation. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 34: 1675-80. PMID 24232065 DOI: 10.1097/Mao.0B013E3182A1A7E6 |
0.752 |
|
2013 |
Deeley MA, Chen A, Datteri RD, Noble J, Cmelak A, Donnelly E, Malcolm A, Moretti L, Jaboin J, Niermann K, Yang ES, Yu DS, Dawant BM. Segmentation editing improves efficiency while reducing inter-expert variation and maintaining accuracy for normal brain tissues in the presence of space-occupying lesions. Physics in Medicine and Biology. 58: 4071-97. PMID 23685866 DOI: 10.1088/0031-9155/58/12/4071 |
0.794 |
|
2013 |
McRackan TR, Balachandran R, Blachon GS, Mitchell JE, Noble JH, Wright CG, Fitzpatrick JM, Dawant BM, Labadie RF. Validation of minimally invasive, image-guided cochlear implantation using Advanced Bionics, Cochlear, and Medel electrodes in a cadaver model. International Journal of Computer Assisted Radiology and Surgery. 8: 989-95. PMID 23633113 DOI: 10.1007/s11548-013-0842-6 |
0.754 |
|
2013 |
Noble JH, Labadie RF, Gifford RH, Dawant BM. Image-guidance enables new methods for customizing cochlear implant stimulation strategies. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 21: 820-9. PMID 23529109 DOI: 10.1109/Tnsre.2013.2253333 |
0.758 |
|
2013 |
Wanna GB, Carlson ML, Blachon GS, Noble JH, Dawant BM, Labadie RF, Balachandran R. Implantation of the completely ossified cochlea: an image-guided approach. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 34: 522-5. PMID 23370556 DOI: 10.1097/Mao.0B013E31827D8Aa0 |
0.739 |
|
2013 |
Reda FA, Dawant BM, McRackan TR, Labadie RF, Noble JH. Automatic segmentation of intra-cochlear anatomy in post-implantation CT Proceedings of Spie. 8671. DOI: 10.1117/12.2008098 |
0.792 |
|
2013 |
Noble JH, Labadie RF, Wanna GB, Dawant BM. Image guidance could aid performance of atraumatic cochlear implantation surgical techniques Proceedings of Spie - the International Society For Optical Engineering. 8671. DOI: 10.1117/12.2007946 |
0.744 |
|
2012 |
Lecoeur J, Noble JH, Balachandran R, Labadie RF, Dawant BM. Variability of the temporal bone surface's topography: implications for otologic surgery. Proceedings of Spie--the International Society For Optical Engineering. 8316: 83161B. PMID 24027621 DOI: 10.1117/12.911373 |
0.629 |
|
2012 |
Noble JH, Gifford RH, Labadie RF, Dawant BM. Statistical shape model segmentation and frequency mapping of cochlear implant stimulation targets in CT. Medical Image Computing and Computer-Assisted Intervention : Miccai ... International Conference On Medical Image Computing and Computer-Assisted Intervention. 15: 421-8. PMID 23286076 |
0.737 |
|
2012 |
Reda FA, Noble JH, Labadie RF, Dawant BM. Automatic pre- to intra-operative CT registration for image-guided cochlear implant surgery. Ieee Transactions On Bio-Medical Engineering. 59: 3070-7. PMID 22922692 DOI: 10.1109/Tbme.2012.2214775 |
0.737 |
|
2012 |
Kratchman LB, Schurzig D, McRackan TR, Balachandran R, Noble JH, Webster RJ, Labadie RF. A manually operated, advance off-stylet insertion tool for minimally invasive cochlear implantation surgery. Ieee Transactions On Bio-Medical Engineering. 59: 2792-800. PMID 22851233 DOI: 10.1109/Tbme.2012.2210220 |
0.583 |
|
2012 |
McRackan TR, Reda FA, Rivas A, Noble JH, Dietrich MS, Dawant BM, Labadie RF. Comparison of cochlear implant relevant anatomy in children versus adults. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 33: 328-34. PMID 22377644 DOI: 10.1097/Mao.0B013E318245Cc9F |
0.703 |
|
2012 |
Noble JH, D'Haese PF, Dawant BM. Segmentation of the optic tracts using graph-based techniques Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8314. DOI: 10.1117/12.912016 |
0.681 |
|
2012 |
Liu Y, Dawant BM, Pallavaram S, Neimat JS, Konrad PE, D'Haese PF, Datteri RD, Landman BA, Noble JH. A surgeon specific automatic path planning algorithm for deep brain stimulation Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8316. DOI: 10.1117/12.911705 |
0.788 |
|
2012 |
Chen A, Noble JH, Niermann KJ, Deeley MA, Dawant BM. Segmentation of parotid glands in head and neck CT images using a constrained active shape model with landmark uncertainty Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8314. DOI: 10.1117/12.911534 |
0.665 |
|
2012 |
Reda FA, Noble JH, Labadie RF, Dawant BM. Fully automatic surface-based pre- to intra-operative CT registration for cochlear implant Lecture Notes in Computer Science (Including Subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics). 7359: 89-98. DOI: 10.1007/978-3-642-31340-0_10 |
0.69 |
|
2011 |
Noble JH, Schuman TA, Wright CG, Labadie RF, Dawant BM. Automatic Identification of Cochlear Implant Electrode Arrays for Post-Operative Assessment. Proceedings of Spie--the International Society For Optical Engineering. 7962. PMID 26041945 DOI: 10.1117/12.878490 |
0.782 |
|
2011 |
Noble JH, Dawant BM. A new approach for tubular structure modeling and segmentation using graph-based techniques. Medical Image Computing and Computer-Assisted Intervention : Miccai ... International Conference On Medical Image Computing and Computer-Assisted Intervention. 14: 305-12. PMID 22003713 DOI: 10.1007/978-3-642-23626-6_38 |
0.601 |
|
2011 |
Reda FA, Noble JH, Rivas A, McRackan TR, Labadie RF, Dawant BM. Automatic segmentation of the facial nerve and chorda tympani in pediatric CT scans. Medical Physics. 38: 5590-600. PMID 21992377 DOI: 10.1118/1.3634048 |
0.745 |
|
2011 |
Deeley MA, Chen A, Datteri R, Noble JH, Cmelak AJ, Donnelly EF, Malcolm AW, Moretti L, Jaboin J, Niermann K, Yang ES, Yu DS, Yei F, Koyama T, Ding GX, et al. Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: a multi-expert study. Physics in Medicine and Biology. 56: 4557-77. PMID 21725140 DOI: 10.1088/0031-9155/56/14/021 |
0.784 |
|
2011 |
Noble JH, Labadie RF, Majdani O, Dawant BM. Automatic segmentation of intracochlear anatomy in conventional CT. Ieee Transactions On Bio-Medical Engineering. 58: 2625-32. PMID 21708495 DOI: 10.1109/Tbme.2011.2160262 |
0.771 |
|
2011 |
Noble JH, Dawant BM. An atlas-navigated optimal medial axis and deformable model algorithm (NOMAD) for the segmentation of the optic nerves and chiasm in MR and CT images. Medical Image Analysis. 15: 877-84. PMID 21684796 DOI: 10.1016/J.Media.2011.05.001 |
0.669 |
|
2011 |
Wanna GB, Noble JH, McRackan TR, Dawant BM, Dietrich MS, Watkins LD, Rivas A, Schuman TA, Labadie RF. Assessment of electrode placement and audiological outcomes in bilateral cochlear implantation. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 32: 428-32. PMID 21283037 DOI: 10.1097/Mao.0B013E3182096Dc2 |
0.774 |
|
2011 |
McRackan TR, Dawant B, Blachon GS, Labadie RF, Noble J, Balachandran R. Cadaveric Percutaneous CI with AB, Cochlear, and Medel Electrodes Otolaryngology–Head and Neck Surgery. 145: P87-P88. DOI: 10.1177/0194599811416318A148 |
0.776 |
|
2011 |
Balachandran R, Mitchell JE, Noble J, Schurzig D, Blachon G, McRackan TR, Webster RJ, Dawant BM, Fitzpatrick JM, Labadie RF. Insertion of electrode array using percutaneous cochlear implantation technique: A cadaveric study Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7964. DOI: 10.1117/12.878786 |
0.777 |
|
2011 |
Reda FA, Noble JH, Rivas A, Labadie RF, Dawant BM. Model-based segmentation of the facial nerve and chorda tympani in pediatric CT scans Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7962. DOI: 10.1117/12.877599 |
0.71 |
|
2010 |
Schuman TA, Noble JH, Wright CG, Wanna GB, Dawant B, Labadie RF. Anatomic verification of a novel method for precise intrascalar localization of cochlear implant electrodes in adult temporal bones using clinically available computed tomography. The Laryngoscope. 120: 2277-83. PMID 20939074 DOI: 10.1002/Lary.21104 |
0.738 |
|
2010 |
Noble JH, Majdani O, Labadie RF, Dawant B, Fitzpatrick JM. Automatic determination of optimal linear drilling trajectories for cochlear access accounting for drill-positioning error. The International Journal of Medical Robotics + Computer Assisted Surgery : Mrcas. 6: 281-90. PMID 20812268 DOI: 10.1002/Rcs.330 |
0.763 |
|
2010 |
Balachandran R, Mitchell JE, Blachon G, Noble JH, Dawant BM, Fitzpatrick JM, Labadie RF. Percutaneous cochlear implant drilling via customized frames: an in vitro study. Otolaryngology--Head and Neck Surgery : Official Journal of American Academy of Otolaryngology-Head and Neck Surgery. 142: 421-6. PMID 20172392 DOI: 10.1016/J.Otohns.2009.11.029 |
0.709 |
|
2010 |
Labadie RF, Balachandran R, Mitchell JE, Noble JH, Majdani O, Haynes DS, Bennett ML, Dawant BM, Fitzpatrick JM. Clinical validation study of percutaneous cochlear access using patient-customized microstereotactic frames. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 31: 94-9. PMID 20019561 DOI: 10.1097/Mao.0B013E3181C2F81A |
0.7 |
|
2010 |
Deeley M, Datteri R, Chen A, Moretti L, Niermann K, Noble J, Ding G, Dawant B. MO-D-204B-06: Segmentation Evaluation in the Context of Inter-Physician Variance Medical Physics. 37: 3342-3342. DOI: 10.1118/1.3469067 |
0.774 |
|
2010 |
Noble JH, Rutherford RB, Labadie RF, Majdani O, Dawant BM. Modeling and segmentation of intra-cochlear anatomy in conventional CT Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7623. DOI: 10.1117/12.844747 |
0.781 |
|
2010 |
Noble JH, Datteri RD, Dawant BM, D'Haese PF. Automatic segmentation of the optic tracts for computer assistance of deep brain stimulation procedures 2010 7th Ieee International Symposium On Biomedical Imaging: From Nano to Macro, Isbi 2010 - Proceedings. 864-867. DOI: 10.1109/ISBI.2010.5490123 |
0.802 |
|
2009 |
Noble JH, Dawant BM, Warren FM, Labadie RF. Automatic identification and 3D rendering of temporal bone anatomy. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 30: 436-42. PMID 19339909 DOI: 10.1097/Mao.0B013E31819E61Ed |
0.625 |
|
2009 |
Ding S, Miga MI, Noble JH, Cao A, Dumpuri P, Thompson RC, Dawant BM. Semiautomatic registration of pre- and postbrain tumor resection laser range data: method and validation. Ieee Transactions On Bio-Medical Engineering. 56: 770-80. PMID 19272895 DOI: 10.1109/Tbme.2008.2006758 |
0.737 |
|
2009 |
Noble JH, Dawant BM. Automatic segmentation of the optic nerves and chiasm in CT and MR using the atlas-navigated optimal medial axis and deformable-model algorithm Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7259. DOI: 10.1117/12.810941 |
0.663 |
|
2009 |
Balachandran R, Majdani O, Noble J, Mitchell J, Dawant BM, Fitzpatrick JM, Labadie R. Percutaneous cochlear implant drilling via customized frames Otolaryngology - Head and Neck Surgery. 141: P89-P89. DOI: 10.1016/J.Otohns.2009.06.272 |
0.728 |
|
2008 |
Noble JH, Warren FM, Labadie RF, Dawant BM. Automatic segmentation of the facial nerve and chorda tympani in CT images using spatially dependent feature values. Medical Physics. 35: 5375-84. PMID 19175097 DOI: 10.1118/1.3005479 |
0.73 |
|
2008 |
Labadie RF, Noble JH, Dawant BM, Balachandran R, Majdani O, Fitzpatrick JM. Clinical validation of percutaneous cochlear implant surgery: initial report. The Laryngoscope. 118: 1031-9. PMID 18401279 DOI: 10.1097/Mlg.0B013E31816B309E |
0.712 |
|
2008 |
Noble JH, Warren FM, Labadie RF, Dawant BM. Automatic segmentation of the facial nerve and chorda tympani using image registration and statistical priors Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6914. DOI: 10.1117/12.772034 |
0.705 |
|
2007 |
Al-Marzouqi H, Noble JH, Warren FM, Labadie RF, Fitzpatrick JM, Dawant B. Planning a safe drilling path for cochlear implantation surgery using image registration techniques Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6509. DOI: 10.1117/12.710672 |
0.367 |
|
2007 |
Noble JH, Warren FM, Labadie RF, Dawant B, Fitzpatrick JM. Determination of drill paths for percutaneous cochlear access accounting for target positioning error Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6509. DOI: 10.1117/12.709605 |
0.431 |
|
Show low-probability matches. |