F E. Offeciers - Publications

Affiliations: 
Universiteit Antwerpen (Belgium) 
Area:
Neuroscience Biology, Biomedical Engineering, Audiology

18 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2023 Zarowski A, Leblans M, Sismono F, Dinther JV, Offeciers FE. Calculation of the Faradaic Impedance of the Electrode-Tissue Interface Improves Prediction of Behavioral T/C Levels in Cochlear Implant Patients. The Journal of International Advanced Otology. 19: 368-375. PMID 37789622 DOI: 10.5152/iao.2023.23695  0.465
2021 Zarowski A, Molisz A, Cardinael E, Vermeiren A, Theunen T, De Coninck L, Theuwis L, Siebert J, Offeciers FE. Prediction of Behavioral T/C Levels in Cochlear Implant Patients Based Upon Analysis of Electrode Impedances. Journal of the American Academy of Audiology. 31: 674-679. PMID 33556966 DOI: 10.1055/s-0040-1718701  0.356
2020 Zarowski A, Molisz A, De Coninck L, Vermeiren A, Theunen T, Theuwis L, Przewoźny T, Siebert J, Offeciers FE. Influence of the pre- or postlingual status of cochlear implant recipients on behavioural T/C-levels. International Journal of Pediatric Otorhinolaryngology. 131: 109867. PMID 31999994 DOI: 10.1016/j.ijporl.2020.109867  0.302
2010 Van Deun L, van Wieringen A, Scherf F, Deggouj N, Desloovere C, Offeciers FE, Van de Heyning PH, Dhooge IJ, Wouters J. Earlier intervention leads to better sound localization in children with bilateral cochlear implants. Audiology & Neuro-Otology. 15: 7-17. PMID 19451705 DOI: 10.1159/000218358  0.38
2009 Van Deun L, van Wieringen A, Francart T, Scherf F, Dhooge IJ, Deggouj N, Desloovere C, Van de Heyning PH, Offeciers FE, De Raeve L, Wouters J. Bilateral cochlear implants in children: binaural unmasking. Audiology & Neuro-Otology. 14: 240-7. PMID 19141992 DOI: 10.1159/000190402  0.376
2006 Postnov A, Zarowski A, De Clerck N, Vanpoucke F, Offeciers FE, Van Dyck D, Peeters S. High resolution micro-CT scanning as an innovative tool for evaluation of the surgical positioning of cochlear implant electrodes. Acta Oto-Laryngologica. 126: 467-74. PMID 16698695 DOI: 10.1080/00016480500437377  0.555
2004 Deman PR, Dirckx JJ, Peeters SA, Zarowski AJ, Offeciers FE. Overview of safety imaging methods for newly designed cochlear implant electrodes. Cochlear Implants International. 5: 58-70. PMID 18792196 DOI: 10.1179/cim.2004.5.2.58  0.676
2004 Deman PR, van Dijk B, Offeciers FE, Govaerts PJ. Pitch estimation of a deeply inserted cochlear implant electrode. International Journal of Audiology. 43: 363-8. PMID 15457819 DOI: 10.1080/14992020400050046  0.684
2004 Deman PR, Daemers K, Yperman M, Offeciers FE, Plasmans A, Van Dijk B, Govaerts PJ. Basic fitting and evaluation parameters of a newly designed cochlear implant electrode. Acta Oto-Laryngologica. 124: 281-5. PMID 15141756 DOI: 10.1080/00016480310016910  0.683
2003 De Ceulaer G, Johnson S, Yperman M, Daemers K, Offeciers FE, O'Donoghue GM, Govaerts PJ. Long-term evaluation of the effect of intracochlear steroid deposition on electrode impedance in cochlear implant patients. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 24: 769-74. PMID 14501455 DOI: 10.1097/00129492-200309000-00014  0.54
2003 Deman PR, Kaiser TM, Dirckx JJ, Offeciers FE, Peeters SA. Design, construction and mechanical optimisation process of electrode with radial current flow in the scala tympani. Journal of Neuroscience Methods. 128: 143-50. PMID 12948557 DOI: 10.1016/S0165-0270(03)00170-5  0.67
2002 Govaerts PJ, De Beukelaer C, Daemers K, De Ceulaer G, Yperman M, Somers T, Schatteman I, Offeciers FE. Outcome of cochlear implantation at different ages from 0 to 6 years. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 23: 885-90. PMID 12438851 DOI: 10.1097/00129492-200211000-00013  0.393
1998 Offeciers FE, Govaerts P, Daemers K, De Beukelaer C, Standaert V, Zarowski A, Somers T, Peeters S. The LAURA Pediatric Cochlear Implant Program in Antwerp: what have we learnt in 5 years? Acta Oto-Rhino-Laryngologica Belgica. 52: 105-9. PMID 9651610  0.438
1996 Janssens S, Govaerts PJ, Casselman J, Van Rompaey W, Van Langenhove A, Somers T, Offeciers FE. The LAURA multichannel cochlear implant in a true Mondini dysplasia. European Archives of Oto-Rhino-Laryngology : Official Journal of the European Federation of Oto-Rhino-Laryngological Societies (Eufos) : Affiliated With the German Society For Oto-Rhino-Laryngology - Head and Neck Surgery. 253: 301-4. PMID 8737790 DOI: 10.1007/Bf00171148  0.523
1993 Peeters S, Offeciers FE, Joris P, Moeneclaey L. The Laura cochlear implant programmed with the continuous interleaved and phase-locked continuous interleaved strategies Advances in Oto-Rhino-Laryngology. 48: 261-268. PMID 8273492  0.303
1989 Peeters S, Marquet J, Offeciers FE, Bosiers W, Kinsbergen J, Van Durme M. Cochlear implants: the Laura prosthesis. Journal of Medical Engineering & Technology. 13: 76-80. PMID 2733015 DOI: 10.3109/03091908909030199  0.474
1988 Offeciers FE, Marquet JF. [Cochlear implant in children: posing the problems]. Acta Oto-Rhino-Laryngologica Belgica. 42: 385-92. PMID 3213493  0.345
1985 Offeciers FE, Peeters S, Marquet JF, Sansen W. The UIA-KUL cochlear implant. Goals and status praesens. Acta Oto-Rhino-Laryngologica Belgica. 39: 749-52. PMID 3841456  0.429
Show low-probability matches.