Year |
Citation |
Score |
2021 |
Zhou H, Reeves SJ, Panizzi PR. Estimating the Center of Rotation of Tomographic Imaging Systems with a Limited Number of Projections. Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual International Conference. 2021: 3157-3160. PMID 34891911 DOI: 10.1109/EMBC46164.2021.9629527 |
0.496 |
|
2019 |
Bian Y, Reeves SJ, Beyers R. An efficient motion correction method for frequency-domain images based on Fast Robust Correlation Electronic Imaging. 2019: 142-1-142-5. DOI: 10.2352/Issn.2470-1173.2019.13.Coimg-142 |
0.41 |
|
2017 |
Hu C, Reeves S, Peters D, Twieg D. An efficient reconstruction algorithm based on the alternating direction method of multipliers for joint estimation of R2* and off-resonance in fMRI. Ieee Transactions On Medical Imaging. PMID 28207389 DOI: 10.1109/Tmi.2017.2667698 |
0.437 |
|
2017 |
Anglin P, Reeves SJ, Thurow BS. Characterization of Plenoptic Imaging Systems and Efficient Volumetric Estimation From Plenoptic Data Ieee Journal of Selected Topics in Signal Processing. 11: 1020-1033. DOI: 10.1109/Jstsp.2017.2747481 |
0.566 |
|
2016 |
Price Tack JL, West BS, McGowan CP, Ditchkoff SS, Reeves SJ, Keever AC, Grand JB. AnimalFinder: A semi-automated system for animal detection in time-lapse camera trap images Ecological Informatics. 36: 145-151. DOI: 10.1016/J.Ecoinf.2016.11.003 |
0.53 |
|
2015 |
Hu C, Reeves S. Trust region methods for estimation of a complex exponential decay model in MRI with a single-shot or multi-shot trajectory. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. PMID 26068316 DOI: 10.1109/Tip.2015.2442917 |
0.485 |
|
2014 |
Anglin P, Reeves SJ, Thurow BS. Efficient volumetric estimation from plenoptic data Proceedings of Spie - the International Society For Optical Engineering. 9020. DOI: 10.1117/12.2047257 |
0.578 |
|
2014 |
Reeves SJ. Image Restoration: Fundamentals of Image Restoration Academic Press Library in Signal Processing. 4: 165-192. DOI: 10.1016/B978-0-12-396501-1.00006-6 |
0.599 |
|
2012 |
Reeves SJ. Optimal space-varying regularization in iterative image restoration. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. 3: 319-24. PMID 18291932 DOI: 10.1109/83.287028 |
0.51 |
|
2011 |
Reeves SJ. Accelerating Sparse Reconstruction for Fast and Precomputable System Matrix Inverses Electronic Imaging. 7873. DOI: 10.1117/12.884583 |
0.394 |
|
2011 |
Ma T, Reeves SJ. Optimal image acquisition by auto-defocusing Proceedings of Spie. 7876: 787605. DOI: 10.1117/12.872630 |
0.525 |
|
2010 |
Parmar M, Reeves SJ. Selection of optimal spectral sensitivity functions for color filter arrays. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. 19: 3190-203. PMID 20519156 DOI: 10.1109/Tip.2010.2051622 |
0.668 |
|
2010 |
Twieg DB, Reeves SJ. Basic properties of SS-PARSE parameter estimates. Ieee Transactions On Medical Imaging. 29: 1156-72. PMID 20304731 DOI: 10.1109/Tmi.2010.2041787 |
0.421 |
|
2009 |
Feng W, Reeves SJ, Denney TS, Lloyd S, Dell'Italia L, Gupta H. A new consistent image registration formulation with a B-spline deformation model Proceedings - 2009 Ieee International Symposium On Biomedical Imaging: From Nano to Macro, Isbi 2009. 979-982. DOI: 10.1109/ISBI.2009.5193218 |
0.409 |
|
2008 |
Tang W, Reeves SJ, Twieg DB. A new approach for joint estimation of local magnitude, decay and frequency from single-shot MRI Proceedings of Spie - the International Society For Optical Engineering. 6814. DOI: 10.1117/12.774013 |
0.674 |
|
2007 |
Tang W, Reeves SJ, Twieg DB. Fast joint estimation of local magnitude, decay and frequency from single-shot MRI Proceedings of Spie - the International Society For Optical Engineering. 6498. DOI: 10.1117/12.704505 |
0.743 |
|
2006 |
Pan R, Reeves SJ. Efficient Huber-Markov edge-preserving image restoration. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. 15: 3728-35. PMID 17153946 DOI: 10.1109/Tip.2006.881971 |
0.74 |
|
2006 |
Gao Y, Strakowski SM, Reeves SJ, Hetherington HP, Chu WJ, Lee JH. Fast spectroscopic imaging using online optimal sparse k-space acquisition and projections onto convex sets reconstruction. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 55: 1265-71. PMID 16680731 DOI: 10.1002/Mrm.20905 |
0.525 |
|
2006 |
Feng W, Reeves SJ. Estimation of color filter array data from JPEG images for improved demosaicking Electronic Imaging. 6065: 606510. DOI: 10.1117/12.657899 |
0.596 |
|
2006 |
Denney TS, Reeves SJ. Bayesian image reconstruction from fourier-domain samples using prior edge information convergence and parameter sensitivity Proceedings of Spie - the International Society For Optical Engineering. 6065. DOI: 10.1117/12.641706 |
0.614 |
|
2006 |
Parmar M, Reeves SJ, Denney TS. Bayesian restoration of color images using a non-homogenous cross-channel prior Proceedings - International Conference On Image Processing, Icip. 3. DOI: 10.1109/ICIP.2007.4379357 |
0.702 |
|
2005 |
Reeves SJ. Fast image restoration without boundary artifacts. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. 14: 1448-53. PMID 16238051 DOI: 10.1109/Tip.2005.854474 |
0.578 |
|
2005 |
Parmar M, Reeves SJ, Denney TS. Bayesian edge-preserving color image reconstruction from color filter array data Proceedings of Spie - the International Society For Optical Engineering. 5674: 259-268. DOI: 10.1117/12.597627 |
0.73 |
|
2005 |
Pan R, Reeves SJ. Fast Huber-Markov edge-preserving image restoration Proceedings of Spie - the International Society For Optical Engineering. 5674: 138-146. DOI: 10.1117/12.587823 |
0.755 |
|
2005 |
Chaudhari KA, Reeves SJ. Mosaic image compression Electronic Imaging. 5678: 189-197. DOI: 10.1117/12.587186 |
0.595 |
|
2005 |
Denney TS, Reeves SJ. Bayesian image reconstruction from Fourier-domain samples using prior edge information Journal of Electronic Imaging. 14. DOI: 10.1117/1.2135747 |
0.598 |
|
2004 |
Parmar M, Reeves SJ. Color filter array design based on a human visual model Electronic Imaging. 5299: 73-82. DOI: 10.1117/12.538833 |
0.651 |
|
2003 |
Nguyen TD, Reeves SJ, Denney TR. On the optimality of magnetic resonance tag patterns for heart wall motion estimation. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. 12: 524-32. PMID 18237929 DOI: 10.1109/Tip.2003.812387 |
0.386 |
|
2003 |
Denney TS, Reeves SJ. MR Spectroscopic Image Reconstruction Using Structural Information from Anatomical MR Images Proceedings of Spie - the International Society For Optical Engineering. 5016: 131-140. DOI: 10.1117/12.479701 |
0.587 |
|
2002 |
Gao Y, Reeves SJ. Fast kappa-space sample selection in MRSI with a limited region of support. Ieee Transactions On Medical Imaging. 20: 868-76. PMID 11585204 DOI: 10.1109/42.952725 |
0.553 |
|
2001 |
Gao Y, Reeves SJ. Optimal k-space sampling in MRSI for images with a limited region of support. Ieee Transactions On Medical Imaging. 19: 1168-78. PMID 11212365 DOI: 10.1109/42.897808 |
0.537 |
|
2001 |
Bakir T, Reeves SJ. A filter design method for minimizing ringing in a region of interest in MR spectroscopic images. Ieee Transactions On Medical Imaging. 19: 585-600. PMID 11026462 DOI: 10.1109/42.870664 |
0.403 |
|
2001 |
Gao Y, Reeves SJ. Optimal dithering of focal plane arrays in passive millimeter-wave imaging Optical Engineering. 40: 2179-2187. DOI: 10.1117/1.1402622 |
0.545 |
|
2000 |
Gao Y, Reeves SJ. Efficient backward selection of k -space samples in MRI on a hexagonal grid Circuits Systems and Signal Processing. 19: 267-278. DOI: 10.1007/Bf01200888 |
0.517 |
|
1999 |
Reeves SJ. Imaging a class of non-Gaussian fields beyond the diffraction limit Journal of the Optical Society of America A. 16: 264. DOI: 10.1364/Josaa.16.000264 |
0.518 |
|
1999 |
Reeves SJ. An efficient implementation of the backward greedy algorithm for sparse signal reconstruction Ieee Signal Processing Letters. 6: 266-268. DOI: 10.1109/97.789606 |
0.395 |
|
1999 |
Reeves SJ, Zhe Z. Sequential algorithms for observation selection Ieee Transactions On Signal Processing. 47: 123-132. DOI: 10.1109/78.738245 |
0.368 |
|
1995 |
Reeves SJ, Higdon AC. Perceptual evaluation of the mean-square error choice of regularization parameter. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. 4: 107-10. PMID 18289964 DOI: 10.1109/83.350808 |
0.396 |
|
1995 |
Reeves SJ. Selection of K-space samples in localized MR spectroscopy of arbitrary volumes of interest. Journal of Magnetic Resonance Imaging : Jmri. 5: 245-7. PMID 7766989 DOI: 10.1002/Jmri.1880050222 |
0.532 |
|
1995 |
Reeves S. On the selection of median structure for image filtering Ieee Transactions On Circuits and Systems Ii: Analog and Digital Signal Processing. 42: 556-558. DOI: 10.1109/82.404089 |
0.464 |
|
1995 |
Reeves S, Heck L. Selection of observations in signal reconstruction Ieee Transactions On Signal Processing. 43: 788-791. DOI: 10.1109/78.370637 |
0.36 |
|
1995 |
Reeves SJ. Generalized cross-validation as a stopping rule for the Richardson-Lucy algorithm International Journal of Imaging Systems and Technology. 6: 387-391. DOI: 10.1002/Ima.1850060412 |
0.458 |
|
1994 |
Perry KM, Reeves SJ. A Practical Stopping Rule for Iterative Signal Restoration Ieee Transactions On Signal Processing. 42: 1829-1833. DOI: 10.1109/78.298292 |
0.389 |
|
1993 |
Reeves SJ, Eddins SL. Comments on “Iterative Procedures for Reduction of Blocking Effects in Transform Image Coding” Ieee Transactions On Circuits and Systems For Video Technology. 3: 439-440. DOI: 10.1109/76.260202 |
0.447 |
|
1992 |
Reeves SJ, Mersereau RM. Blur identification by the method of generalized cross-validation. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. 1: 301-11. PMID 18296164 DOI: 10.1109/83.148604 |
0.575 |
|
1992 |
Reeves SJ, Mersereau RM. Automatic assessment of constraint sets in image restoration. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. 1: 119-23. PMID 18296147 DOI: 10.1109/83.128038 |
0.394 |
|
1992 |
Reeves SJ, Perry KM. Practical stopping rule for iterative image restoration Elektrotechnik Und Informationstechnik. 1657: 192-200. DOI: 10.1117/12.58327 |
0.613 |
|
1992 |
Reeves SJ. A cross-validation framework for solving image restoration problems Journal of Visual Communication and Image Representation. 3: 433-445. DOI: 10.1016/1047-3203(92)90044-T |
0.53 |
|
Show low-probability matches. |