Year |
Citation |
Score |
2018 |
Beattie C, Fazio P, Zmeureanu R, Rao J. Experimental study of air-to-air heat exchangers for use in arctic housing Applied Thermal Engineering. 129: 1281-1291. DOI: 10.1016/J.Applthermaleng.2017.10.112 |
0.339 |
|
2016 |
Lam TC, Ge H, Fazio P. Energy positive curtain wall configurations for a cold climate using the Analysis of Variance (ANOVA) approach Building Simulation. 9: 297-310. DOI: 10.1007/S12273-016-0275-6 |
0.654 |
|
2015 |
Tariku F, Kumaran K, Fazio P. Application of a Whole-Building Hygrothermal model in energy, durability, and indoor humidity retrofit design Journal of Building Physics. 39: 3-34. DOI: 10.1177/1744259114522400 |
0.414 |
|
2015 |
Molina G, Bustamante W, Rao J, Fazio P, Vera S. Evaluation of radiance's genBSDF capability to assess solar bidirectional properties of complex fenestration systems Journal of Building Performance Simulation. 8: 216-225. DOI: 10.1080/19401493.2014.912355 |
0.337 |
|
2015 |
Wyss S, Fazio P, Rao J, Kayello A. Investigation of Thermal Performance of Structural Insulated Panels for Northern Canada Journal of Architectural Engineering. 21: 4015006. DOI: 10.1061/(Asce)Ae.1943-5568.0000174 |
0.311 |
|
2015 |
Liu X, Chen Y, Ge H, Fazio P, Chen G. Determination of Optimum Insulation Thickness of Exterior Wall with Moisture Transfer in Hot Summer and Cold Winter Zone of China Procedia Engineering. 121: 1008-1015. DOI: 10.1016/J.Proeng.2015.09.072 |
0.625 |
|
2015 |
Liu X, Chen Y, Ge H, Fazio P, Chen G, Guo X. Determination of optimum insulation thickness for building walls with moisture transfer in hot summer and cold winter zone of China Energy and Buildings. 109: 361-368. DOI: 10.1016/J.Enbuild.2015.10.021 |
0.626 |
|
2015 |
Liu X, Chen Y, Ge H, Fazio P, Chen G. Numerical investigation for thermal performance of exterior walls of residential buildings with moisture transfer in hot summer and cold winter zone of China Energy and Buildings. 93: 259-268. DOI: 10.1016/J.Enbuild.2015.02.016 |
0.637 |
|
2015 |
Lam TC, Ge H, Fazio P. Impact of curtain wall configurations on building energy performance in the perimeter zone for a cold climate Energy Procedia. 78: 352-357. DOI: 10.1016/J.Egypro.2015.11.665 |
0.654 |
|
2015 |
Thirunavukarasu A, Fazio P, Ge H, Athienitis A. Performance Assessment Protocol for Pre-engineered Manufactured Self-sustaining (PEMaSS) Housing to Remote Regions Energy Procedia. 78: 207-212. DOI: 10.1016/J.Egypro.2015.11.375 |
0.632 |
|
2015 |
Beattie C, Fazio P, Zmeureanu R, Rao J. A preliminary study of the performance of sensible and latent heat exchanger cores at the frosting limit for use in Arctic housing Energy Procedia. 78: 2596-2601. DOI: 10.1016/J.Egypro.2015.11.299 |
0.367 |
|
2014 |
Zmeureanu R, Fazio P. Computer–aided design of energy–efficient buildings Journal of Computer Applications in Technology. DOI: 10.1504/Ijcat.1990.062714 |
0.441 |
|
2014 |
Hachem C, Athienitis A, fazio P. Design of Curtain Wall Facades for Improved Solar Potential and Daylight Distribution Energy Procedia. 57: 1815-1824. DOI: 10.1016/J.Egypro.2014.10.045 |
0.403 |
|
2014 |
Ge H, Yang X, Fazio P, Rao J. Influence of moisture load profiles on moisture buffering potential and moisture residuals of three groups of hygroscopic materials Building and Environment. 81: 162-171. DOI: 10.1016/J.Buildenv.2014.06.021 |
0.586 |
|
2014 |
Vera S, Rao J, Fazio P, Campo A. Mixed convective heat transfer through a horizontal opening in a full-scale, two-story test-hut Applied Thermal Engineering. 64: 499-507. DOI: 10.1016/J.Applthermaleng.2013.12.039 |
0.327 |
|
2014 |
Hachem C, Athienitis A, Fazio P. Energy performance enhancement in multistory residential buildings Applied Energy. 116: 9-19. DOI: 10.1016/J.Apenergy.2013.11.018 |
0.365 |
|
2013 |
Hachem C, Fazio P, Athienitis A. Solar optimized residential neighborhoods: Evaluation and design methodology Solar Energy. 95: 42-64. DOI: 10.1016/J.Solener.2013.06.002 |
0.405 |
|
2012 |
Hachem C, Athienitis A, Fazio P. Evaluation of energy supply and demand in solar neighborhood Energy and Buildings. 49: 335-347. DOI: 10.1016/J.Enbuild.2012.02.021 |
0.349 |
|
2012 |
Hachem C, Athienitis A, Fazio P. Design Methodology of Solar Neighborhoods Energy Procedia. 30: 1284-1293. DOI: 10.1016/J.Egypro.2012.11.141 |
0.394 |
|
2012 |
Li Y, Fazio P, Rao J. Numerical investigation of the influence of room factors on HAM transport in a full-scale experimental room Building and Environment. 50: 114-124. DOI: 10.1016/J.Buildenv.2011.10.021 |
0.352 |
|
2012 |
Yang X, Fazio P, Ge H, Rao J. Evaluation of moisture buffering capacity of interior surface materials and furniture in a full-scale experimental investigation Building and Environment. 47: 188-196. DOI: 10.1016/J.Buildenv.2011.07.025 |
0.612 |
|
2012 |
Li Y, Fazio P, Rao J. An investigation of moisture buffering performance of wood paneling at room level and its buffering effect on a test room Building and Environment. 47: 205-216. DOI: 10.1016/J.Buildenv.2011.07.021 |
0.323 |
|
2011 |
Hachem C, Athienitis A, Fazio P. Parametric investigation of geometric form effects on solar potential of housing units Solar Energy. 85: 1864-1877. DOI: 10.1016/J.Solener.2011.04.027 |
0.323 |
|
2011 |
Hachem C, Athienitis A, Fazio P. Investigation of solar potential of housing units in different neighborhood designs Energy and Buildings. 43: 2262-2273. DOI: 10.1016/J.Enbuild.2011.05.008 |
0.327 |
|
2011 |
Mao Q, Fazio P, Rao J. A limit state design (LSD) approach for comparing relative drying performance of wood-frame envelope systems with full-scale lab testing Building and Environment. 46: 797-806. DOI: 10.1016/J.Buildenv.2010.10.015 |
0.418 |
|
2011 |
Tariku F, Kumaran K, Fazio P. Erratum to: Determination of indoor humidity profile using a whole-building hygrothermal model Building Simulation. 4: 277-277. DOI: 10.1007/S12273-011-0033-8 |
0.354 |
|
2011 |
Tariku F, Kumaran K, Fazio P. Determination of indoor humidity profile using a whole-building hygrothermal model Building Simulation. 4: 61-78. DOI: 10.1007/S12273-011-0031-X |
0.447 |
|
2010 |
Hachem C, Chaubey Y, Fazio P, Rao J, Bartlett K. Statistical Analysis of Microbial Volatile Organic Compounds in an Experimental Project: Identification and Transport Analysis: Indoor and Built Environment. 19: 275-285. DOI: 10.1177/1420326X09342680 |
0.344 |
|
2010 |
Tan X, Hammad A, Fazio P. Automated Code Compliance Checking for Building Envelope Design Journal of Computing in Civil Engineering. 24: 203-211. DOI: 10.1061/(Asce)0887-3801(2010)24:2(203) |
0.415 |
|
2010 |
Tariku F, Kumaran K, Fazio P. Transient model for coupled heat, air and moisture transfer through multilayered porous media International Journal of Heat and Mass Transfer. 53: 3035-3044. DOI: 10.1016/J.Ijheatmasstransfer.2010.03.024 |
0.379 |
|
2010 |
Tariku F, Kumaran K, Fazio P. Integrated analysis of whole building heat, air and moisture transfer International Journal of Heat and Mass Transfer. 53: 3111-3120. DOI: 10.1016/J.Ijheatmasstransfer.2010.03.016 |
0.456 |
|
2010 |
Vera S, Fazio P, Rao J. Interzonal air and moisture transport through large horizontal openings in a full-scale two-story test-hut: Part 2 – CFD study Building and Environment. 45: 622-631. DOI: 10.1016/J.Buildenv.2009.07.021 |
0.345 |
|
2009 |
Fazio P, Alturkistani A, Rao J, Mao Q. A New Testing Method to Evaluate the Relative Drying Performance of Different Building Envelope Systems Using Water Trays in Stud Cavities as Moisture Source Journal of Astm International. 6: 102085. DOI: 10.1520/Jai102085 |
0.363 |
|
2009 |
Mao Q, Fazio P, Rao J. In-cavity evaporation allowance―A drying capacity indicator for wood-frame wall system Building and Environment. 44: 2418-2429. DOI: 10.1016/J.Buildenv.2009.04.005 |
0.393 |
|
2009 |
Hachem C, Fazio P, Rao J, Bartlett K, Chaubey YP. Identification and transport investigation of microbial volatile organic compounds in full-scale stud cavities Building and Environment. 44: 1691-1698. DOI: 10.1016/J.Buildenv.2008.11.011 |
0.341 |
|
2009 |
Rao J, Fazio P, Bartlett K, Yang D. Experimental evaluation of potential transport of mold spores from moldy studs in full-size wall assemblies Building and Environment. 44: 1568-1577. DOI: 10.1016/J.Buildenv.2008.10.001 |
0.36 |
|
2009 |
Li Q, Rao J, Fazio P. Development of HAM tool for building envelope analysis Building and Environment. 44: 1065-1073. DOI: 10.1016/J.Buildenv.2008.07.017 |
0.43 |
|
2008 |
Mitchell MR, Link RE, Wu Y, Fazio P, Kumaran MK(. Moisture Buffering Capacities of Five North American Building Materials Journal of Testing and Evaluation. 36: 101228. DOI: 10.1520/Jte101228 |
0.352 |
|
2008 |
FAZIO P, BEDARD C, GOWRI K. Knowledge-Based System Development Tools for Processing Design Specifications Computer-Aided Civil and Infrastructure Engineering. 3: 333-344. DOI: 10.1111/J.1467-8667.1988.Tb00175.X |
0.375 |
|
2008 |
Fazio P, GoWRI K. Temperature and Vapor Pressure Gradients Across Wall Assemblies Using Microcomputer Graphics Computer-Aided Civil and Infrastructure Engineering. 3: 167-171. DOI: 10.1111/J.1467-8667.1988.Tb00166.X |
0.39 |
|
2008 |
Alturkistani A, Fazio P, Rao J, Mao Q. A new test method to determine the relative drying capacity of building envelope panels of various configurations Building and Environment. 43: 2203-2215. DOI: 10.1016/J.Buildenv.2008.01.008 |
0.389 |
|
2007 |
Fazio P, Mao Q, Ge H, Alturkistani A, Rao J. Test Method to Measure the Relative Capacity of Wall Panels to Evacuate Moisture from Their Stud Cavity Journal of Architectural Engineering. 13: 194-204. DOI: 10.1061/(Asce)1076-0431(2007)13:4(194) |
0.658 |
|
2007 |
Fazio P, He HS, Hammad A, Horvat M. IFC-based framework for evaluating total performance of building envelopes Journal of Architectural Engineering. 13: 44-53. DOI: 10.1061/(Asce)1076-0431(2007)13:1(44) |
0.445 |
|
2005 |
Horvat M, Fazio P. Comparative Review of Existing Certification Programs and Performance Assessment Tools for Residential Buildings Architectural Science Review. 48: 69-80. DOI: 10.3763/Asre.2005.4810 |
0.372 |
|
2005 |
DePani S, Fazio P. Airtightness Testing of Two- and Three-Unit Buildings with a Single Fan Journal of Architectural Engineering. 11: 19-24. DOI: 10.1061/(Asce)1076-0431(2005)11:1(19) |
0.335 |
|
2004 |
Ge H, Fazio P. Experimental Evaluation of Thermal Response and Condensation Performance of Metal Curtain Walls Subjected to Air Leakage Journal of Architectural Engineering. 10: 61-68. DOI: 10.1061/(Asce)1076-0431(2004)10:2(61) |
0.6 |
|
2004 |
Ge H, Fazio P. Experimental investigation of cold draft induced by two different types of glazing panels in metal curtain walls Building and Environment. 39: 115-125. DOI: 10.1016/J.Buildenv.2003.08.006 |
0.651 |
|
2003 |
Derome D, Fortin Y, Fazio P. Modeling of Moisture Behavior of Wood Planks in Nonvented Flat Roofs Journal of Architectural Engineering. 9: 26-40. DOI: 10.1061/(Asce)1076-0431(2003)9:1(26) |
0.586 |
|
2002 |
Fazio P, Rao J, Ge H. Measuring Air Leakage Characteristics with Flexible Double Air Chambers Journal of Architectural Engineering. 8: 89-95. DOI: 10.1061/(Asce)1076-0431(2002)8:3(88) |
0.62 |
|
2001 |
Iliescu S, Fazio P, Gowri K. Similarity assessment in a case‐based reasoning framework for building envelope design Logistics Information Management. 14: 376-386. DOI: 10.1108/Eum0000000006249 |
0.669 |
|
2000 |
Desmarais G, Derome D, Fazio P. Mapping of Air Leakage in Exterior Wall Assemblies Journal of Thermal Envelope and Building Science. 24: 132-154. DOI: 10.1106/Bwh8-9D3J-R939-957E |
0.601 |
|
2000 |
Derome D, Fazio P. Large-Scale Testing Of Two Flat Roof Assemblies Insulated With Cellulose Journal of Architectural Engineering. 6: 12-23. DOI: 10.1061/(Asce)1076-0431(2000)6:1(12) |
0.587 |
|
1999 |
Zmeureanu R, Fazio P, DePani S, Calla R. Development of an energy rating system for existing houses Energy and Buildings. 29: 107-119. DOI: 10.1016/S0378-7788(98)00037-1 |
0.303 |
|
1998 |
Koroth SR, Fazio P, Feldman D. Evaluation of Clay Brick Durability Using Ultrasonic Pulse Velocity Journal of Architectural Engineering. 4: 142-147. DOI: 10.1061/(Asce)1076-0431(1998)4:4(142) |
0.303 |
|
1998 |
Koroth SR, Feldman D, Fazio P. Development of New Durability Index for Clay Bricks Journal of Architectural Engineering. 4: 87-93. DOI: 10.1061/(Asce)1076-0431(1998)4:3(87) |
0.302 |
|
1998 |
Koroth SR, Fazio P, Feldman D. Comparative Study of Durability Indices for Clay Bricks Journal of Architectural Engineering. 4: 26-33. DOI: 10.1061/(Asce)1076-0431(1998)4:1(26) |
0.37 |
|
1998 |
Mokhtar A, Bédard C, Fazio P. Information Model for Managing Design Changes in a Collaborative Environment Journal of Computing in Civil Engineering. 12: 82-92. DOI: 10.1061/(Asce)0887-3801(1998)12:2(82) |
0.394 |
|
1998 |
Rivard H, Bédard C, Ha K, Fazio P. Shared conceptual model for the building envelope design process Building and Environment. 34: 175-187. DOI: 10.1016/S0360-1323(98)00005-5 |
0.389 |
|
1998 |
Pasqualetto L, Zmeureanu R, Fazio P. A case study of validation of an energy analysis program: MICRO-DOE2.1E Building and Environment. 33: 21-41. DOI: 10.1016/S0360-1323(97)00032-2 |
0.31 |
|
1997 |
Fazio P, Athienitis AK, Marsh C, Rao J. Environmental Chamber for Investigation of Building Envelope Performance Journal of Architectural Engineering. 3: 97-102. DOI: 10.1061/(Asce)1076-0431(1997)3:2(97) |
0.433 |
|
1996 |
Savin D, Alkass S, Fazio P. Construction resource leveling using neural networks Canadian Journal of Civil Engineering. 23: 917-925. DOI: 10.1139/L96-898 |
0.301 |
|
1995 |
Zmeureanu R, Abushakra B, Fazio P. A case study of energy savings by using the water-side economiser system in a large office building in montreal Architectural Science Review. 38: 21-27. DOI: 10.1080/00038628.1995.9696772 |
0.33 |
|
1995 |
Zhu D, Mallidi SR, Fazio P. Quantitative driving rain exposure on a vertical wall at various Canadian cities Building and Environment. 30: 533-544. DOI: 10.1016/0360-1323(95)00016-Y |
0.351 |
|
1995 |
Rivard H, Bédard C, Fazio P, Ha KH. Functional analysis of the preliminary building envelope design process Building and Environment. 30: 391-401. DOI: 10.1016/0360-1323(95)00006-R |
0.418 |
|
1995 |
Fazio P, Mallidi SR, Zhu D. A quantitative study for the measurement of driving rain exposure in the montréal region Building and Environment. 30: 1-11. DOI: 10.1016/0360-1323(94)E0028-P |
0.341 |
|
1994 |
Hegazy T, Fazio P, Moselhi O. Developing Practical Neural Network Applications Using Back‐Propagation Computer-Aided Civil and Infrastructure Engineering. 9: 145-159. DOI: 10.1111/J.1467-8667.1994.Tb00369.X |
0.702 |
|
1993 |
Moselhi O, Hegazy T, Fazio P. DBID: Analogy‐Based DSS for Bidding in Construction Journal of Construction Engineering and Management-Asce. 119: 466-479. DOI: 10.1061/(Asce)0733-9364(1993)119:3(466) |
0.703 |
|
1993 |
Diasty RE, Fazio P, Budaiwi I. The dynamic modelling of air humidity behaviour in a multi-zone space Building and Environment. 28: 33-51. DOI: 10.1016/0360-1323(93)90004-M |
0.337 |
|
1993 |
Diasty RE, Fazio P, Budaiwi I. Dynamic modelling of moisture absorption and desorption in buildings Building and Environment. 28: 21-32. DOI: 10.1016/0360-1323(93)90003-L |
0.327 |
|
1992 |
Haghighat F, Auger M, Fazio P. Thermal Comfort Aspect of Three Different Heating Systems:Field Measurements Indoor and Built Environment. 1: 103-111. DOI: 10.1177/1420326X9200100207 |
0.301 |
|
1992 |
Moselhi O, Hegazy T, Fazio P. Potential applications of neural networks in construction Canadian Journal of Civil Engineering. 19: 521-529. DOI: 10.1139/L92-061 |
0.703 |
|
1992 |
Moselhi O, Fazio P, Hason S. Automation of concrete slab-on-grade construction Journal of Construction Engineering and Management-Asce. 118: 731-748. DOI: 10.1061/(Asce)0733-9364(1992)118:4(731) |
0.705 |
|
1991 |
Moselhi O, Leonard C, Fazio P. Impact of change orders on construction productivity Canadian Journal of Civil Engineering. 18: 484-492. DOI: 10.1139/L91-059 |
0.304 |
|
1991 |
Moselhi O, Hegazy T, Fazio P. Neural networks as tools in construction Journal of Construction Engineering and Management-Asce. 117: 606-625. DOI: 10.1061/(Asce)0733-9364(1991)117:4(606) |
0.703 |
|
1991 |
Zmeureanu R, Fazio P. Analysis of the energy performance of office buildings in Montreal in 1988 Energy and Buildings. 17: 63-74. DOI: 10.1016/0378-7788(91)90072-B |
0.337 |
|
1991 |
Haghighat F, Rao J, Fazio P. The influence of turbulent wind on air change rates—a modelling approach Building and Environment. 26: 95-109. DOI: 10.1016/0360-1323(91)90017-6 |
0.318 |
|
1991 |
Gowri K, Marsh C, Bedard C, Fazio P. Knowledge-based assistant for aluminum component design Computers & Structures. 38: 9-20. DOI: 10.1016/0045-7949(91)90118-6 |
0.372 |
|
1990 |
Fazio P. A case study in integrated building design Canadian Journal of Civil Engineering. 17: 636-642. DOI: 10.1139/L90-072 |
0.451 |
|
1990 |
Haghighat F, Fazio P, Rao J. A procedure for measurement of ventilation effectiveness in residential buildings Building and Environment. 25: 163-172. DOI: 10.1016/0360-1323(90)90029-Q |
0.353 |
|
1989 |
Zmeureanu R, Fazio P. Role of computers in the design of energy-responsive buildings Canadian Journal of Civil Engineering. 16: 55-61. DOI: 10.1139/L89-007 |
0.428 |
|
1989 |
Fazio P, Gowri K. Expert system ‐ flat roofs Batiment International, Building Research and Practice. 17: 294-298. DOI: 10.1080/01823328908726990 |
0.391 |
|
1989 |
Fazio P, Zmeureanu R, Kowalski A. Select-HVAC: knowledge-based system as an advisor to configure HVAC systems Computer-Aided Design. 21: 79-86. DOI: 10.1016/0010-4485(89)90142-5 |
0.435 |
|
1989 |
Fazio P, Bedard C, Gowri K. Knowledge-based system development tools for processing design specifications Computer-Aided Design. 21: 184-185. DOI: 10.1016/0010-4485(89)90088-2 |
0.344 |
|
1989 |
Fazio P, Bedard C, Gowri K. Knowledge-based system approach to building envelope design Computer-Aided Design. 21: 519-527. DOI: 10.1016/0010-4485(89)90060-2 |
0.443 |
|
1988 |
Haghighat F, Fazio P, Zmeureanu R. A systematic approach for derivation of transfer function coefficients of buildings from experimental data Energy and Buildings. 12: 101-111. DOI: 10.1016/0378-7788(88)90072-2 |
0.413 |
|
1988 |
Fazio P, Gowri K. Folded plate sandwich panel roof integrating passive solar glazings Building and Environment. 23: 39-44. DOI: 10.1016/0360-1323(88)90016-9 |
0.305 |
|
1988 |
Zmeureanu R, Fazio P. Thermal performance of a hollow core concrete floor system for passive cooling Building and Environment. 23: 243-252. DOI: 10.1016/0360-1323(88)90009-1 |
0.355 |
|
1988 |
Haghighat F, Fazio P, Unny TE. A predictive stochastic model for indoor air quality Building and Environment. 23: 195-201. DOI: 10.1016/0360-1323(88)90004-2 |
0.313 |
|
1987 |
Zmeureanu R, Fazio P, Haghighat F. Analytical and inter-program validation of a building thermal model Energy and Buildings. 10: 121-133. DOI: 10.1016/0378-7788(87)90014-4 |
0.311 |
|
1987 |
Shapiro MM, Diasty RE, Fazio P. Transient three-dimensional window thermal effects Energy and Buildings. 10: 89-98. DOI: 10.1016/0378-7788(87)90011-9 |
0.309 |
|
1987 |
Zmeureanu R, Fazio P. Use of decision models under uncertainty in thermal design Computer-Aided Design. 19: 523-526. DOI: 10.1016/0010-4485(87)90088-1 |
0.387 |
|
1980 |
Pall AS, Marsh C, Fazio P. Friction Joints for Seismic Control of Large Panel Structures Pci Journal. 38-61. DOI: 10.15554/Pcij.11011980.38.61 |
0.358 |
|
1980 |
El-Shimi M, White R, Fazio P. Influence of façade geometry on weathering Canadian Journal of Civil Engineering. 7: 597-613. DOI: 10.1139/L80-073 |
0.36 |
|
1979 |
Chockalingam S, Ha K, Fazio P. Simplified analysis of cold-formed steel shear diaphragms Canadian Journal of Civil Engineering. 6: 232-242. DOI: 10.1139/L79-024 |
0.304 |
|
1978 |
Moselhi O, Fazio P, Zielinski Z. Simplified analysis of wall-frame structures Canadian Journal of Civil Engineering. 5: 262-273. DOI: 10.1139/L78-030 |
0.704 |
|
1978 |
Mattar S, Manning P, Fazio P, Bitterlich W. Application of the decision by exclusion rule: The design of external walls Building and Environment. 13: 217-232. DOI: 10.1016/0360-1323(78)90013-6 |
0.329 |
|
1978 |
Mattar S, Bitterlich W, Manning P, Fazio P. A decision model for the design of building enclosures Building and Environment. 13: 201-216. DOI: 10.1016/0360-1323(78)90012-4 |
0.368 |
|
1978 |
Ha HK, Fazio P. Flexural behaviour of sandwich floor assembly Building and Environment. 13: 61-67. DOI: 10.1016/0360-1323(78)90009-4 |
0.311 |
|
Show low-probability matches. |