Year |
Citation |
Score |
2014 |
Chang G, Deniz CM, Honig S, Egol K, Regatte RR, Zhu Y, Sodickson DK, Brown R. MRI of the hip at 7T: feasibility of bone microarchitecture, high-resolution cartilage, and clinical imaging. Journal of Magnetic Resonance Imaging : Jmri. 39: 1384-93. PMID 24115554 DOI: 10.1002/Jmri.24305 |
0.313 |
|
2013 |
Deniz CM, Brown R, Lattanzi R, Alon L, Sodickson DK, Zhu Y. Maximum efficiency radiofrequency shimming: Theory and initial application for hip imaging at 7 tesla. Magnetic Resonance in Medicine. 69: 1379-88. PMID 22714835 DOI: 10.1002/Mrm.24377 |
0.461 |
|
2013 |
Alon L, Deniz CM, Brown R, Sodickson DK, Zhu Y. Method for in situ characterization of radiofrequency heating in parallel transmit MRI. Magnetic Resonance in Medicine. 69: 1457-65. PMID 22714806 DOI: 10.1002/Mrm.24374 |
0.436 |
|
2012 |
Zhu Y, Alon L, Deniz CM, Brown R, Sodickson DK. System and SAR characterization in parallel RF transmission. Magnetic Resonance in Medicine. 67: 1367-78. PMID 22139808 DOI: 10.1002/Mrm.23126 |
0.432 |
|
2012 |
Deniz CM, Alon L, Brown R, Sodickson DK, Zhu Y. Specific absorption rate benefits of including measured electric field interactions in parallel excitation pulse design. Magnetic Resonance in Medicine. 67: 164-74. PMID 22135040 DOI: 10.1002/Mrm.23004 |
0.403 |
|
2009 |
Lattanzi R, Sodickson DK, Grant AK, Zhu Y. Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitations. Magnetic Resonance in Medicine. 61: 315-34. PMID 19165885 DOI: 10.1002/Mrm.21782 |
0.435 |
|
2008 |
Xu D, King KF, Zhu Y, McKinnon GC, Liang ZP. Designing multichannel, multidimensional, arbitrary flip angle RF pulses using an optimal control approach. Magnetic Resonance in Medicine. 59: 547-60. PMID 18306407 DOI: 10.1002/Mrm.21485 |
0.37 |
|
2007 |
Xu D, King KF, Zhu Y, McKinnon GC, Liang ZP. A noniterative method to design large-tip-angle multidimensional spatially-selective radio frequency pulses for parallel transmission. Magnetic Resonance in Medicine. 58: 326-34. PMID 17654576 DOI: 10.1002/Mrm.21314 |
0.387 |
|
2006 |
Niendorf T, Hardy CJ, Giaquinto RO, Gross P, Cline HE, Zhu Y, Kenwood G, Cohen S, Grant AK, Joshi S, Rofsky NM, Sodickson DK. Toward single breath-hold whole-heart coverage coronary MRA using highly accelerated parallel imaging with a 32-channel MR system. Magnetic Resonance in Medicine. 56: 167-76. PMID 16755538 DOI: 10.1002/Mrm.20923 |
0.351 |
|
2005 |
Sodickson DK, Hardy CJ, Zhu Y, Giaquinto RO, Gross P, Kenwood G, Niendorf T, Lejay H, McKenzie CA, Ohliger MA, Grant AK, Rofsky NM. Rapid volumetric MRI using parallel imaging with order-of-magnitude accelerations and a 32-element RF coil array: feasibility and implications. Academic Radiology. 12: 626-35. PMID 15866137 DOI: 10.1016/J.Acra.2005.01.012 |
0.451 |
|
2004 |
Zhu Y, Hardy CJ, Sodickson DK, Giaquinto RO, Dumoulin CL, Kenwood G, Niendorf T, Lejay H, McKenzie CA, Ohliger MA, Rofsky NM. Highly parallel volumetric imaging with a 32-element RF coil array. Magnetic Resonance in Medicine. 52: 869-77. PMID 15389961 DOI: 10.1002/Mrm.20209 |
0.422 |
|
2004 |
Hardy CJ, Darrow RD, Saranathan M, Giaquinto RO, Zhu Y, Dumoulin CL, Bottomley PA. Large field-of-view real-time MRI with a 32-channel system. Magnetic Resonance in Medicine. 52: 878-84. PMID 15389946 DOI: 10.1002/Mrm.20225 |
0.457 |
|
2004 |
Zhu Y. Parallel excitation with an array of transmit coils. Magnetic Resonance in Medicine. 51: 775-84. PMID 15065251 DOI: 10.1002/mrm.20011 |
0.322 |
|
2003 |
Zhu Y, Dumoulin CL. Extended field-of-view imaging with table translation and frequency sweeping. Magnetic Resonance in Medicine. 49: 1106-12. PMID 12768589 DOI: 10.1002/Mrm.10470 |
0.419 |
|
2000 |
Hardy CJ, Saranathan M, Zhu Y, Darrow RD. Coronary angiography by real-time MRI with adaptive averaging. Magnetic Resonance in Medicine. 44: 940-6. PMID 11108632 DOI: 10.1002/1522-2594(200012)44:6<940::Aid-Mrm16>3.0.Co;2-F |
0.35 |
|
Show low-probability matches. |