Graeme M. Clark - Publications

Affiliations: 
University of Melbourne, Parkville, Victoria, Australia 
Area:
Auditory system
Website:
http://www.bionicear.org/people/clarkg/

316 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2016 Spiers K, Cardamone T, Furness JB, Clark JC, Patrick JF, Clark GM. An X-ray fluorescence microscopic analysis of the tissue surrounding the multi-channel cochlear implant electrode array. Cochlear Implants International. 1-3. PMID 27078517 DOI: 10.1080/14670100.2016.1157943  0.378
2016 Harris AR, Hutchinson R, Molino PJ, Kapsa RMI, Clark GM, Paolini AG, Wallace GG. Correlation of impedance and effective electrode area of dextran sulfate doped PEDOT modified electrodes Journal of the Electrochemical Society. 163: H534-H540. DOI: 10.1149/2.0711607jes  0.354
2016 Harris AR, Molino PJ, Kapsa RMI, Clark GM, Paolini AG, Wallace GG. Effective area and charge density of dextran sulphate doped PEDOT modified electrodes Synthetic Metals. 220: 394-401. DOI: 10.1016/j.synthmet.2016.07.010  0.329
2015 Allitt BJ, Harris AR, Morgan SJ, Clark GM, Paolini AG. Thin-film micro-electrode stimulation of the cochlea in rats exposed to aminoglycoside induced hearing loss. Hearing Research. 331: 13-26. PMID 26471198 DOI: 10.1016/j.heares.2015.10.003  0.453
2015 Harris AR, Molino PJ, Kapsa RM, Clark GM, Paolini AG, Wallace GG. Correlation of the impedance and effective electrode area of doped PEDOT modified electrodes for brain-machine interfaces. The Analyst. 140: 3164-74. PMID 25773879 DOI: 10.1039/c4an02362e  0.336
2015 Harris AR, Molino PJ, Kapsa RM, Clark GM, Paolini AG, Wallace GG. Optical and electrochemical methods for determining the effective area and charge density of conducting polymer modified electrodes for neural stimulation. Analytical Chemistry. 87: 738-46. PMID 25495574 DOI: 10.1021/ac503733s  0.367
2015 Clark GM. The multi-channel cochlear implant: multi-disciplinary development of electrical stimulation of the cochlea and the resulting clinical benefit. Hearing Research. 322: 4-13. PMID 25159273 DOI: 10.1016/j.heares.2014.08.002  0.477
2014 Clark GM, Clark J, Cardamone T, Clarke M, Nielsen P, Jones R, Arhatari B, Birbilis N, Curtain R, Xu J, Wagstaff S, Gibson P, O'Leary S, Furness J. Biomedical studies on temporal bones of the first multi-channel cochlear implant patient at the University of Melbourne. Cochlear Implants International. 15: S1-15. PMID 24915284 DOI: 10.1179/1754762814Y.0000000087  0.342
2013 Clark GM. The multichannel cochlear implant for severe-to-profound hearing loss. Nature Medicine. 19: 1236-9. PMID 24100994 DOI: 10.1038/nm.3340  0.433
2013 Clark GM, Clark JC, Furness JB. The evolving science of cochlear implants. Jama. 310: 1225-6. PMID 24018758 DOI: 10.1001/Jama.2013.278142  0.404
2013 Quigley AF, Bulluss KJ, Kyratzis IL, Gilmore K, Mysore T, Schirmer KS, Kennedy EL, O'Shea M, Truong YB, Edwards SL, Peeters G, Herwig P, Razal JM, Campbell TE, Lowes KN, ... ... Clark GM, et al. Engineering a multimodal nerve conduit for repair of injured peripheral nerve. Journal of Neural Engineering. 10: 016008. PMID 23283383 DOI: 10.1088/1741-2560/10/1/016008  0.317
2012 Allitt BJ, Morgan SJ, Bell S, Nayagam DA, Arhatari B, Clark GM, Paolini AG. Midbrain responses to micro-stimulation of the cochlea using high density thin-film arrays. Hearing Research. 287: 30-42. PMID 22531007 DOI: 10.1016/j.heares.2012.04.004  0.438
2012 Clark G. The multi-channel cochlear implant and the relief of severe-to-profound deafness Cochlear Implants International. 13: 69-85. PMID 22334029 DOI: 10.1179/1754762811Y.0000000019  0.448
2011 Nayagam DA, Williams RA, Chen J, Magee KA, Irwin J, Tan J, Innis P, Leung RT, Finch S, Williams CE, Clark GM, Wallace GG. Biocompatibility of immobilized aligned carbon nanotubes. Small (Weinheim An Der Bergstrasse, Germany). 7: 1035-42. PMID 21374804 DOI: 10.1002/Smll.201002083  0.313
2011 Nayagam DAX, Williams RA, Chen J, Magee KA, Irwin J, Tan J, Innis P, Leung RT, Finch S, Williams CE, Clark GM, Wallace GG. Carbon Nanotubes: Biocompatibility of Immobilized Aligned Carbon Nanotubes (Small 8/2011) Small. 7: 981-981. DOI: 10.1002/Smll.201190025  0.301
2010 Wei BP, Shepherd RK, Robins-Browne RM, Clark GM, O'Leary SJ. Pneumococcal meningitis post-cochlear implantation: preventative measures. Otolaryngology--Head and Neck Surgery : Official Journal of American Academy of Otolaryngology-Head and Neck Surgery. 143: S9-14. PMID 20970694 DOI: 10.1016/J.Otohns.2010.08.011  0.406
2010 Wei BP, Shepherd RK, Robins-Browne RM, Clark GM, O'Leary SJ. Pneumococcal meningitis post-cochlear implantation: potential routes of infection and pathophysiology. Otolaryngology--Head and Neck Surgery : Official Journal of American Academy of Otolaryngology-Head and Neck Surgery. 143: S15-23. PMID 20970686 DOI: 10.1016/J.Otohns.2010.08.010  0.396
2010 Thompson BC, Richardson RT, Moulton SE, Evans AJ, O'Leary S, Clark GM, Wallace GG. Conducting polymers, dual neurotrophins and pulsed electrical stimulation--dramatic effects on neurite outgrowth. Journal of Controlled Release : Official Journal of the Controlled Release Society. 141: 161-7. PMID 19788902 DOI: 10.1016/j.jconrel.2009.09.016  0.383
2009 Wallace GG, Moulton SE, Clark GM. Applied physics. Electrode-cellular interface. Science (New York, N.Y.). 324: 185-6. PMID 19359568 DOI: 10.1126/science.1168346  0.311
2009 Richardson RT, Wise AK, Thompson BC, Flynn BO, Atkinson PJ, Fretwell NJ, Fallon JB, Wallace GG, Shepherd RK, Clark GM, O'Leary SJ. Polypyrrole-coated electrodes for the delivery of charge and neurotrophins to cochlear neurons. Biomaterials. 30: 2614-24. PMID 19178943 DOI: 10.1016/J.Biomaterials.2009.01.015  0.455
2009 Clark G. The multi-channel cochlear implant: Past, present and future perspectives Cochlear Implants International. 10: 2-13. PMID 19127562 DOI: 10.1002/cii.378  0.471
2009 Evans AJ, Thompson BC, Wallace GG, Millard R, O'Leary SJ, Clark GM, Shepherd RK, Richardson RT. Promoting neurite outgrowth from spiral ganglion neuron explants using polypyrrole/BDNF-coated electrodes. Journal of Biomedical Materials Research. Part A. 91: 241-50. PMID 18814235 DOI: 10.1002/Jbm.A.32228  0.421
2009 Clark G. Research directions for future generations of cochlear implants. Cochlear Implants International. 2-8. PMID 18792214 DOI: 10.1002/cii.146  0.351
2008 Clark GM. Personal reflections on the multichannel cochlear implant and a view of the future. Journal of Rehabilitation Research and Development. 45: 651-93. PMID 18816421 DOI: 10.1682/JRRD.2007.05.0064  0.417
2008 Wei BP, Robins-Browne RM, Shepherd RK, Clark GM, O'Leary SJ. Can we prevent cochlear implant recipients from developing pneumococcal meningitis? Clinical Infectious Diseases : An Official Publication of the Infectious Diseases Society of America. 46: e1-7. PMID 18171202 DOI: 10.1086/524083  0.41
2007 Wei BP, Clark GM, O'Leary SJ, Shepherd RK, Robins-Browne RM. Meningitis after cochlear implantation. Bmj (Clinical Research Ed.). 335: 1058. PMID 18033888 DOI: 10.1136/Bmj.39380.598380.80  0.406
2007 Wei BP, Robins-Browne RM, Shepherd RK, Azzopardi K, Clark GM, O'Leary SJ. Assessment of the protective effect of pneumococcal vaccination in preventing meningitis after cochlear implantation. Archives of Otolaryngology--Head & Neck Surgery. 133: 987-94. PMID 17938321 DOI: 10.1001/Archotol.133.10.987  0.345
2007 Wei BP, Shepherd RK, Robins-Browne RM, Clark GM, O'Leary SJ. Threshold shift: effects of cochlear implantation on the risk of pneumococcal meningitis. Otolaryngology--Head and Neck Surgery : Official Journal of American Academy of Otolaryngology-Head and Neck Surgery. 136: 589-96. PMID 17418257 DOI: 10.1016/J.Otohns.2006.11.039  0.392
2007 Kha HN, Chen BK, Clark GM. 3D finite element analyses of insertion of the Nucleus standard straight and the Contour electrode arrays into the human cochlea. Journal of Biomechanics. 40: 2796-805. PMID 17408675 DOI: 10.1016/j.jbiomech.2007.01.013  0.326
2007 Wei BP, Shepherd RK, Robins-Browne RM, Clark GM, O'Leary SJ. Effects of inner ear trauma on the risk of pneumococcal meningitis. Archives of Otolaryngology--Head & Neck Surgery. 133: 250-9. PMID 17372082 DOI: 10.1001/Archotol.133.3.250  0.356
2007 Richardson RT, Thompson B, Moulton S, Newbold C, Lum MG, Cameron A, Wallace G, Kapsa R, Clark G, O'Leary S. The effect of polypyrrole with incorporated neurotrophin-3 on the promotion of neurite outgrowth from auditory neurons Biomaterials. 28: 513-523. PMID 17007922 DOI: 10.1016/J.Biomaterials.2006.09.008  0.439
2007 Chen BK, Kha HN, Clark GM. Development of a steerable cochlear implant electrode array Ifmbe Proceedings. 15: 607-610.  0.317
2006 Wei BP, Robins-Browne RM, Shepherd RK, Azzopardi K, Clark GM, O'Leary SJ. Protective effects of local administration of ciprofloxacin on the risk of pneumococcal meningitis after cochlear implantation. The Laryngoscope. 116: 2138-44. PMID 17146386 DOI: 10.1097/01.Mlg.0000243192.43574.81  0.378
2006 Wei BP, Shepherd RK, Robins-Browne RM, Clark GM, O'Leary SJ. Pneumococcal meningitis threshold model: A potential tool to assess infectious risk of new or existing inner ear surgical interventions. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 27: 1152-61. PMID 16980916 DOI: 10.1097/01.Mao.0000227898.80656.54  0.379
2006 Wei BP, Shepherd RK, Robins-Browne RM, Clark GM, O'Leary SJ. Pneumococcal meningitis: development of a new animal model. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 27: 844-54. PMID 16936571 DOI: 10.1097/01.Mao.0000231603.25961.F1  0.375
2006 Clark GM. The multiple-channel cochlear implant: the interface between sound and the central nervous system for hearing, speech, and language in deaf people-a personal perspective. Philosophical Transactions of the Royal Society of London. Series B, Biological Sciences. 361: 791-810. PMID 16627295 DOI: 10.1098/rstb.2005.1782  0.455
2005 Richardson RT, O'Leary S, Wise A, Hardman J, Clark G. A single dose of neurotrophin-3 to the cochlea surrounds spiral ganglion neurons and provides trophic support Hearing Research. 204: 37-47. PMID 15925190 DOI: 10.1016/j.heares.2005.01.001  0.359
2005 Noushi F, Richardson RT, Hardman J, Clark G, O'Leary S. Delivery of neurotrophin-3 to the cochlea using alginate beads Otology and Neurotology. 26: 528-533. PMID 15891662 DOI: 10.1097/01.mao.0000169780.84588.a5  0.349
2005 Wise AK, Richardson R, Hardman J, Clark G, O'Leary S. Resprouting and survival of guinea pig cochlear neurons in response to the administration of the neurotrophins brain-derived neurotrophic factor and neurotrophin-3 Journal of Comparative Neurology. 487: 147-165. PMID 15880560 DOI: 10.1002/cne.20563  0.391
2005 Gillespie LN, Marzella PL, Clark GM, Crook JM. Netrin-1 as a guidance molecule in the postnatal rat cochlea. Hearing Research. 199: 117-23. PMID 15574306 DOI: 10.1016/J.Heares.2004.07.004  0.74
2004 Richardson RT, Wise A, O'Leary S, Hardman J, Casley D, Clark G. Tracing neurotrophin-3 diffusion and uptake in the guinea pig cochlea Hearing Research. 198: 25-35. PMID 15567599 DOI: 10.1016/j.heares.2004.02.012  0.333
2004 Kha HN, Chen BK, Clark GM, Jones R. Stiffness properties for Nucleus standard straight and contour electrode arrays. Medical Engineering & Physics. 26: 677-85. PMID 15471696 DOI: 10.1016/j.medengphy.2004.05.001  0.33
2004 Paolini AG, Clarey JC, Needham K, Clark GM. Fast inhibition alters first spike timing in auditory brainstem neurons. Journal of Neurophysiology. 92: 2615-21. PMID 15140909 DOI: 10.1152/jn.00327.2004  0.342
2004 Gillespie LN, Clark GM, Marzella PL. Delayed neurotrophin treatment supports auditory neuron survival in deaf guinea pigs. Neuroreport. 15: 1121-5. PMID 15129158 DOI: 10.1097/00001756-200405190-00008  0.767
2004 Clarey JC, Paolini AG, Grayden DB, Burkitt AN, Clark GM. Ventral cochlear nucleus coding of voice onset time in naturally spoken syllables. Hearing Research. 190: 37-59. PMID 15051129 DOI: 10.1016/S0378-5955(04)00017-6  0.357
2004 Clark GM, Wallace G. Bionic ears: their development and future advances using neurotrophins and inherently conducting polymers Applied Bionics and Biomechanics. 1: 67-89. DOI: 10.3233/Abb-2004-9693538  0.386
2004 Clark G. Research directions for future generations of cochlear implants Cochlear Implants International. 5: 2-8. DOI: 10.1002/Cii.146  0.456
2004 Grayden DB, Burkitt AN, Kenny OP, Clarey JC, Paolini AG, Clark GM. A cochlear implant speech processing strategy based on an auditory model Proceedings of the 2004 Intelligent Sensors, Sensor Networks and Information Processing Conference, Issnip '04. 491-496.  0.322
2003 Clark G. Cochlear implants in children: Safety as well as speech and language International Journal of Pediatric Otorhinolaryngology. 67: S7-S20. PMID 14662167 DOI: 10.1016/j.ijporl.2003.08.006  0.393
2003 Gillespie LN, Clark GM, Bartlett PF, Marzella PL. BDNF-induced survival of auditory neurons in vivo: Cessation of treatment leads to accelerated loss of survival effects. Journal of Neuroscience Research. 71: 785-90. PMID 12605404 DOI: 10.1002/Jnr.10542  0.779
2003 Chen BK, Clark GM, Jones R. Evaluation of trajectories and contact pressures for the straight nucleus cochlear implant electrode array - a two-dimensional application of finite element analysis. Medical Engineering & Physics. 25: 141-7. PMID 12538068 DOI: 10.1016/S1350-4533(02)00150-9  0.355
2002 Dawson PW, McKay CM, Busby PA, Clark GM. Rate-of-processing ability in children using cochlear implants and its relevance to speech perception. Cochlear Implants International. 3: 126-38. PMID 18792119 DOI: 10.1179/cim.2002.3.2.126  0.409
2002 Dowell RC, Dettman SJ, Blamey PJ, Barker EJ, Clark GM. Speech perception in children using cochlear implants: prediction of long-term outcomes. Cochlear Implants International. 3: 1-18. PMID 18792108 DOI: 10.1179/cim.2002.3.1.1  0.431
2002 Dawson PW, Busby PA, McKay CM, Clark GM. Short-term auditory memory in children using cochlear implants and its relevance to receptive language. Journal of Speech, Language, and Hearing Research : Jslhr. 45: 789-801. PMID 12199408 DOI: 10.1044/1092-4388(2002/064)  0.388
2002 Dowell RC, Dettman SJ, Hill K, Winton E, Barker EJ, Clark GM. Speech perception outcomes in older children who use multichannel cochlear implants: older is not always poorer. The Annals of Otology, Rhinology & Laryngology. Supplement. 189: 97-101. PMID 12018359 DOI: 10.1177/00034894021110S520  0.421
2002 Surowiecki VN, Sarant J, Maruff P, Blamey PJ, Busby PA, Clark GM. Cognitive processing in children using cochlear implants: the relationship between visual memory, attention, and executive functions and developing language skills. The Annals of Otology, Rhinology & Laryngology. Supplement. 189: 119-26. PMID 12018338 DOI: 10.1177/00034894021110S524  0.324
2002 Kuhlmann L, Burkitt AN, Paolini A, Clark GM. Summation of spatiotemporal input patterns in leaky integrate-and-fire neurons: application to neurons in the cochlear nucleus receiving converging auditory nerve fiber input. Journal of Computational Neuroscience. 12: 55-73. PMID 11932560 DOI: 10.1023/A:1014994113776  0.336
2001 Briggs RJ, Tykocinski M, Saunders E, Hellier W, Dahm M, Pyman B, Clark GM. Surgical implications of perimodiolar cochlear implant electrode design: avoiding intracochlear damage and scala vestibuli insertion. Cochlear Implants International. 2: 135-49. PMID 18792095 DOI: 10.1179/cim.2001.2.2.135  0.396
2001 Clark GM. Cochlear implants: climbing new mountains the Graham Fraser memorial lecture 2001. Cochlear Implants International. 2: 75-97. PMID 18792091 DOI: 10.1179/cim.2001.2.2.75  0.386
2001 Xu J, Stevenson AW, Gao D, Tykocinski M, Lawrence D, Wilkins SW, Clark GM, Saunders E, Cowan RS. The role of radiographic phase-contrast imaging in the development of intracochlear electrode arrays. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 22: 862-8. PMID 11698810 DOI: 10.1097/00129492-200111000-00026  0.392
2001 Paolini AG, FitzGerald JV, Burkitt AN, Clark GM. Temporal processing from the auditory nerve to the medial nucleus of the trapezoid body in the rat. Hearing Research. 159: 101-16. PMID 11520638 DOI: 10.1016/S0378-5955(01)00327-6  0.315
2001 FitzGerald JV, Burkitt AN, Clark GM, Paolini AG. Delay analysis in the auditory brainstem of the rat: comparison with click latency. Hearing Research. 159: 85-100. PMID 11520637 DOI: 10.1016/S0378-5955(01)00325-2  0.32
2001 Cohen LT, Saunders E, Clark GM. Psychophysics of a prototype peri-modiolar cochlear implant electrode array. Hearing Research. 155: 63-81. PMID 11335077 DOI: 10.1016/S0378-5955(01)00248-9  0.43
2001 Tykocinski M, Saunders E, Cohen LT, Treaba C, Briggs RJ, Gibson P, Clark GM, Cowan RS. The contour electrode array: safety study and initial patient trials of a new perimodiolar design. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 22: 33-41. PMID 11314713 DOI: 10.1097/00129492-200101000-00007  0.385
2001 Sarant JZ, Blamey PJ, Dowell RC, Clark GM, Gibson WP. Variation in speech perception scores among children with cochlear implants. Ear and Hearing. 22: 18-28. PMID 11271973 DOI: 10.1097/00003446-200102000-00003  0.392
2001 Gillespie LN, Clark GM, Bartlett PF, Marzella PL. LIF is more potent than BDNF in promoting neurite outgrowth of mammalian auditory neurons in vitro. Neuroreport. 12: 275-9. PMID 11209934 DOI: 10.1097/00001756-200102120-00019  0.775
2000 Clark GM. The cochlear implant: a search for answers. Cochlear Implants International. 1: 1-15. PMID 18791989 DOI: 10.1179/cim.2000.1.1.1  0.387
2000 Briggs RJ, Fagan P, Atlas M, Kaye AH, Sheehy J, Hollow R, Shaw S, Clark GM. Multichannel auditory brainstem implantation: the Australian experience. The Journal of Laryngology and Otology. Supplement. 46-9. PMID 11211439 DOI: 10.1258/0022215001904734  0.475
2000 Vandali AE, Whitford LA, Plant KL, Clark GM. Speech perception as a function of electrical stimulation rate: using the Nucleus 24 cochlear implant system. Ear and Hearing. 21: 608-24. PMID 11132787 DOI: 10.1097/00003446-200012000-00008  0.394
2000 Dawson PW, McKay CM, Busby PA, Grayden DB, Clark GM. Electrode discrimination and speech perception in young children using cochlear implants. Ear and Hearing. 21: 597-607. PMID 11132786 DOI: 10.1097/00003446-200012000-00007  0.442
2000 Bruce IC, Irlicht LS, White MW, O'Leary SJ, Clark GM. Renewal-process approximation of a stochastic threshold model for electrical neural stimulation. Journal of Computational Neuroscience. 9: 119-32. PMID 11030517 DOI: 10.1023/A:1008942623671  0.586
2000 Henry BA, McKay CM, McDermott HJ, Clark GM. The relationship between speech perception and electrode discrimination in cochlear implantees. The Journal of the Acoustical Society of America. 108: 1269-80. PMID 11008827 DOI: 10.1121/1.1287711  0.403
2000 Busby PA, Clark GM. Electrode discrimination by early-deafened subjects using the cochlear limited multiple-electrode cochlear implant. Ear and Hearing. 21: 291-304. PMID 10981605 DOI: 10.1097/00003446-200008000-00004  0.447
2000 Tykocinski M, Cohen LT, Pyman BC, Roland T, Treaba C, Palamara J, Dahm MC, Shepherd RK, Xu J, Cowan RS, Cohen NL, Clark GM. Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays. The American Journal of Otology. 21: 205-11. PMID 10733185 DOI: 10.1016/S0196-0709(00)80010-1  0.401
2000 Araki S, Kawano A, Seldon HL, Shepherd RK, Funasaka S, Clark GM. Effects of intracochlear factors on spiral ganglion cells and auditory brain stem response after long-term electrical stimulation in deafened kittens. Otolaryngology--Head and Neck Surgery : Official Journal of American Academy of Otolaryngology-Head and Neck Surgery. 122: 425-33. PMID 10699822 DOI: 10.1016/S0194-5998(00)70060-X  0.426
2000 Pyman B, Blamey P, Lacy P, Clark G, Dowell R. The development of speech perception in children using cochlear implants: Effects of etiologic factors and delayed milestones American Journal of Otology. 21: 57-61. PMID 10651436 DOI: 10.1016/S0196-0709(00)80076-9  0.42
2000 Xu J, Xu SA, Cohen LT, Clark GM. Cochlear view: postoperative radiography for cochlear implantation. The American Journal of Otology. 21: 49-56. PMID 10651435 DOI: 10.1016/S0196-0709(00)80075-7  0.424
2000 Busby PA, Clark GM. Pitch estimation by early-deafened subjects using a multiple-electrode cochlear implant. The Journal of the Acoustical Society of America. 107: 547-58. PMID 10641663 DOI: 10.1121/1.428353  0.382
1999 Galvin KL, Mavrias G, Moore A, Cowan RS, Blamey PJ, Clark GM. A comparison of Tactaid II+ and Tactaid 7 use by adults with a profound hearing impairment. Ear and Hearing. 20: 471-82. PMID 10613385 DOI: 10.1097/00003446-199912000-00003  0.329
1999 Bruce IC, White MW, Irlicht LS, O'Leary SJ, Clark GM. The effects of stochastic neural activity in a model predicting intensity perception with cochlear implants: low-rate stimulation. Ieee Transactions On Bio-Medical Engineering. 46: 1393-404. PMID 10612897 DOI: 10.1109/10.804567  0.561
1999 Shepherd RK, Linahan N, Xu J, Clark GM, Araki S. Chronic electrical stimulation of the auditory nerve using non-charge-balanced stimuli. Acta Oto-Laryngologica. 119: 674-84. PMID 10587001 DOI: 10.1080/00016489950180621  0.443
1999 Marzella PL, Gillespie LN, Clark GM, Bartlett PF, Kilpatrick TJ. The neurotrophins act synergistically with LIF and members of the TGF-beta superfamily to promote the survival of spiral ganglia neurons in vitro. Hearing Research. 138: 73-80. PMID 10575116 DOI: 10.1016/S0378-5955(99)00152-5  0.763
1999 Marzella PL, Clark GM. Growth factors, auditory neurones and cochlear implants: a review. Acta Oto-Laryngologica. 119: 407-12. PMID 10445053 DOI: 10.1080/00016489950180919  0.44
1999 Rance G, Beer DE, Cone-Wesson B, Shepherd RK, Dowell RC, King AM, Rickards FW, Clark GM. Clinical findings for a group of infants and young children with auditory neuropathy. Ear and Hearing. 20: 238-52. PMID 10386850 DOI: 10.1097/00003446-199906000-00006  0.365
1999 Bruce IC, Irlicht LS, White MW, O'Leary SJ, Dynes S, Javel E, Clark GM. A stochastic model of the electrically stimulated auditory nerve: pulse-train response. Ieee Transactions On Bio-Medical Engineering. 46: 630-7. PMID 10356869 DOI: 10.1109/10.764939  0.551
1999 Bruce IC, White MW, Irlicht LS, O'Leary SJ, Dynes S, Javel E, Clark GM. A stochastic model of the electrically stimulated auditory nerve: single-pulse response. Ieee Transactions On Bio-Medical Engineering. 46: 617-29. PMID 10356868 DOI: 10.1109/10.764938  0.58
1999 Paolini AG, Clark GM. Intracellular responses of onset chopper neurons in the ventral cochlear nucleus to tones: evidence for dual-component processing. Journal of Neurophysiology. 81: 2347-59. PMID 10322071 DOI: 10.1152/Jn.1999.81.5.2347  0.348
1998 Paolini AG, Cotterill EL, Bairaktaris D, Clark GM. Muscimol suppression of the dorsal cochlear nucleus impairs frequency discrimination in rats. Behavioural Brain Research. 97: 79-88. PMID 9867233 DOI: 10.1016/S0166-4328(98)00029-1  0.305
1998 Dawson PW, Nott PE, Clark GM, Cowan RS. A modification of play audiometry to assess speech discrimination ability in severe-profoundly deaf 2- to 4-year-old children. Ear and Hearing. 19: 371-84. PMID 9796646 DOI: 10.1097/00003446-199810000-00004  0.336
1998 Liu X, Seldon HL, Clark GM. Chronic study on the neuronal excitability of the cochlear nuclei of the cat following electrical stimulation. Acta Oto-Laryngologica. 118: 524-9. PMID 9726677 DOI: 10.1080/00016489850154667  0.411
1998 Richardson LM, Busby PA, Blamey PJ, Clark GM. Studies of prosody perception by cochlear implant patients. Audiology : Official Organ of the International Society of Audiology. 37: 231-45. PMID 9723769 DOI: 10.3109/00206099809072977  0.375
1998 Paolini AG, Clark GM. Intracellular responses of the rat anteroventral cochlear nucleus to intracochlear electrical stimulation. Brain Research Bulletin. 46: 317-27. PMID 9671261 DOI: 10.1016/S0361-9230(98)00017-3  0.383
1998 Richardson LM, Busby PA, Clark GM. Modulation detection interference in cochlear implant subjects. The Journal of the Acoustical Society of America. 104: 442-52. PMID 9670536 DOI: 10.1121/1.423248  0.396
1998 Kawano A, Seldon HL, Clark GM, Ramsden RT, Raine CH. Intracochlear factors contributing to psychophysical percepts following cochlear implantation. Acta Oto-Laryngologica. 118: 313-26. PMID 9655204 DOI: 10.1080/00016489850183386  0.373
1998 Araki S, Kawano A, Seldon L, Shepherd RK, Funasaka S, Clark GM. Effects of chronic electrical stimulation on spiral ganglion neuron survival and size in deafened kittens. The Laryngoscope. 108: 687-95. PMID 9591547 DOI: 10.1097/00005537-199805000-00012  0.41
1998 Flynn MC, Dowell RC, Clark GM. Aided speech recognition abilities of adults with a severe or severe-to-profound hearing loss. Journal of Speech, Language, and Hearing Research : Jslhr. 41: 285-99. PMID 9570583 DOI: 10.1044/Jslhr.4102.285  0.382
1998 Paolini AG, Cotterill EL, Bairaktaris D, Clark GM. Muscimol suppression of the dorsal cochlear nucleus modifies frequency tuning in rats. Brain Research. 785: 309-16. PMID 9518664 DOI: 10.1016/S0006-8993(97)01404-2  0.333
1998 Clark GM. Research advances for cochlear implants. Auris, Nasus, Larynx. 25: 73-87. PMID 9512798 DOI: 10.1016/S0385-8146(97)10030-X  0.478
1998 Huang CQ, Shepherd RK, Seligman PM, Clark GM. Reduction in excitability of the auditory nerve following acute electrical stimulation at high stimulus rates: III. Capacitive versus non-capacitive coupling of the stimulating electrodes. Hearing Research. 116: 55-64. PMID 9508028 DOI: 10.1016/S0378-5955(97)00196-2  0.408
1998 Rance G, Dowell RC, Rickards FW, Beer DE, Clark GM. Steady-state evoked potential and behavioral hearing thresholds in a group of children with absent click-evoked auditory brain stem response. Ear and Hearing. 19: 48-61. PMID 9504272 DOI: 10.1097/00003446-199802000-00003  0.372
1998 Liu X, McPhee G, Seldon HL, Clark GM. Acute study on the efficacy and safety of an auditory brainstem prosthesis. Acta Oto-Laryngologica. 118: 37-45. PMID 9504161 DOI: 10.1080/00016489850155107  0.478
1998 Marzella PL, Clark GM, Shepherd RK, Bartlett PF, Kilpatrick TJ. Synergy between TGF-beta 3 and NT-3 to promote the survival of spiral ganglia neurones in vitro. Neuroscience Letters. 240: 77-80. PMID 9486476 DOI: 10.1016/S0304-3940(97)00928-2  0.466
1998 Bruce IC, Irlicht LS, Clark GM. A mathematical analysis of spatiotemporal summation of auditory nerve firings Information Sciences. 111: 303-334. DOI: 10.1016/S0020-0255(98)10010-5  0.579
1997 Liu X, McPhee G, Seldon HL, Clark GM. Histological and physiological effects of the central auditory prosthesis: surface versus penetrating electrodes. Hearing Research. 114: 264-74. PMID 9447940 DOI: 10.1016/S0378-5955(97)00170-6  0.464
1997 Brown M, McAnally KI, Clark GM. Variability of amplitude and area of the auditory nerve compound action potential. Acta Oto-Laryngologica. 117: 836-40. PMID 9442823 DOI: 10.3109/00016489709114210  0.33
1997 McAnally KI, Brown M, Clark GM. Comparison of current waveforms for the electrical stimulation of residual low frequency hearing. Acta Oto-Laryngologica. 117: 831-5. PMID 9442822 DOI: 10.3109/00016489709114209  0.358
1997 Dawson PW, Clark GM. Changes in synthetic and natural vowel perception after specific training for congenitally deafened patients using a multichannel cochlear implant. Ear and Hearing. 18: 488-501. PMID 9416451 DOI: 10.1097/00003446-199712000-00007  0.403
1997 Tykocinski M, Shepherd RK, Clark GM. Reduction in excitability of the auditory nerve following electrical stimulation at high stimulus rates. II. Comparison of fixed amplitude with amplitude modulated stimuli. Hearing Research. 112: 147-57. PMID 9367237 DOI: 10.1016/S0378-5955(97)00117-2  0.392
1997 Paolini AG, Clark GM, Burkitt AN. Intracellular responses of the rat cochlear nucleus to sound and its role in temporal coding. Neuroreport. 8: 3415-21. PMID 9351683 DOI: 10.1097/00001756-199710200-00044  0.341
1997 van Hoesel RJ, Clark GM. Psychophysical studies with two binaural cochlear implant subjects. The Journal of the Acoustical Society of America. 102: 495-507. PMID 9228813 DOI: 10.1121/1.419611  0.389
1997 Liu X, McPhee G, Seldon HL, Clark GM. Acute study on the neuronal excitability of the cochlear nuclei of the guinea pig following electrical stimulation. Acta Oto-Laryngologica. 117: 363-75. PMID 9199522  0.309
1997 Marzella PL, Clark GM, Shepherd RK, Bartlett PF, Kilpatrick TJ. LIF potentiates the NT-3-mediated survival of spiral ganglia neurones in vitro. Neuroreport. 8: 1641-4. PMID 9189906 DOI: 10.1097/00001756-199705060-00017  0.549
1997 McAnally KI, Brown M, Clark GM. Estimating mechanical responses to pulsatile electrical stimulation of the cochlea. Hearing Research. 106: 146-53. PMID 9112114 DOI: 10.1016/S0378-5955(97)00012-9  0.374
1997 McAnally KI, Brown M, Clark GM. Acoustic and electric forward-masking of the auditory nerve compound action potential: evidence for linearity of electro-mechanical transduction. Hearing Research. 106: 137-45. PMID 9112113 DOI: 10.1016/S0378-5955(97)00011-7  0.407
1997 Dawson PW, Skok M, Clark GM. The effect of loudness imbalance between electrodes in cochlear implant users. Ear and Hearing. 18: 156-65. PMID 9099565 DOI: 10.1097/00003446-199704000-00008  0.434
1997 Xu J, Shepherd RK, Millard RE, Clark GM. Chronic electrical stimulation of the auditory nerve at high stimulus rates: a physiological and histopathological study. Hearing Research. 105: 1-29. PMID 9083801 DOI: 10.1016/S0378-5955(96)00193-1  0.472
1997 Busby PA, Clark GM. Pitch and loudness estimation for single and multiple pulse per period electric pulse rates by cochlear implant patients. The Journal of the Acoustical Society of America. 101: 1687-95. PMID 9069636 DOI: 10.1121/1.418178  0.307
1997 Cowan RS, Galvin KL, Klieve S, Barker EJ, Sarant JZ, Dettman S, Hollow R, Rance G, Dowell RC, Pyman B, Clark GM. Contributing factors to improved speech perception in children using the Nucleus 22-channel cochlear prosthesis. Advances in Oto-Rhino-Laryngology. 52: 193-7. PMID 9042485 DOI: 10.1159/000059009  0.332
1997 Henry BA, McKay CM, McDermott HJ, Clark GM. The relationship between speech information perceived by cochlear implantees in different spectral regions and electrode discrimination The Journal of the Acoustical Society of America. 101: 3199-3200. DOI: 10.1121/1.419355  0.383
1997 Clark G. COCHLEAR IMPLANTS IN ADULTS AND CHILDREN: COMMENT Anz Journal of Surgery. 67: 381-381. DOI: 10.1111/j.1445-2197.1997.tb01994.x  0.354
1996 Cohen LT, Busby PA, Clark GM. Cochlear implant place psychophysics. 2. Comparison of forward masking and pitch estimation data. Audiology & Neuro-Otology. 1: 278-92. PMID 9390809 DOI: 10.1159/000259211  0.364
1996 Cohen LT, Busby PA, Whitford LA, Clark GM. Cochlear implant place psychophysics 1. Pitch estimation with deeply inserted electrodes. Audiology & Neuro-Otology. 1: 265-77. PMID 9390808 DOI: 10.1159/000259210  0.409
1996 Blamey PJ, Dooley GJ, Parisi ES, Clark GM. Pitch comparisons of acoustically and electrically evoked auditory sensations. Hearing Research. 99: 139-50. PMID 8970822 DOI: 10.1016/S0378-5955(96)00095-0  0.443
1996 Cohen LT, Xu J, Xu SA, Clark GM. Improved and simplified methods for specifying positions of the electrode bands of a cochlear implant array. The American Journal of Otology. 17: 859-65. PMID 8915414  0.303
1996 Clark GM. Electrical stimulation of the auditory nerve: the coding of frequency, the perception of pitch and the development of cochlear implant speech processing strategies for profoundly deaf people. Clinical and Experimental Pharmacology & Physiology. 23: 766-76. PMID 8911712 DOI: 10.1111/J.1440-1681.1996.Tb01178.X  0.455
1996 Burton MJ, Shepherd RK, Clark GM. Cochlear histopathologic characteristics following long-term implantation. Safety studies in the young monkey. Archives of Otolaryngology--Head & Neck Surgery. 122: 1097-104. PMID 8859123 DOI: 10.1001/Archotol.1996.01890220063011  0.431
1996 Seldon HL, Kawano A, Clark GM. Does age at cochlear implantation affect the distribution of 2-deoxyglucose label in cat inferior colliculus? Hearing Research. 95: 108-19. PMID 8793513 DOI: 10.1016/0378-5955(96)00028-7  0.406
1996 Busby PA, Clark GM. Electrode discrimination by early-deafened cochlear implant patients. Audiology : Official Organ of the International Society of Audiology. 35: 8-22. PMID 8790867 DOI: 10.3109/00206099609071926  0.459
1996 McKay CM, McDermott HJ, Clark GM. The perceptual dimensions of single-electrode and nonsimultaneous dual-electrode stimuli in cochlear implantees. The Journal of the Acoustical Society of America. 99: 1079-90. PMID 8609291 DOI: 10.1121/1.414594  0.415
1996 Flynn MC, Dowell RC, Clark GM. Speech perception for hearing aid users versus cochlear implantees The Journal of the Acoustical Society of America. 100: 2692-2692. DOI: 10.1121/1.417045  0.434
1995 Dawson PW, Blamey PJ, Dettman SJ, Rowland LC, Barker EJ, Tobey EA, Busby PA, Cowan RC, Clark GM. A clinical report on speech production of cochlear implant users. Ear and Hearing. 16: 551-61. PMID 8747805 DOI: 10.1097/00003446-199512000-00002  0.402
1995 Tykocinski M, Shepherd RK, Clark GM. Reduction in excitability of the auditory nerve following electrical stimulation at high stimulus rates. Hearing Research. 88: 124-42. PMID 8575988 DOI: 10.1016/0378-5955(95)00108-G  0.41
1995 Shepherd RK, Clark GM, Xu SA, Pyman BC. Cochlear pathology following reimplantation of a multichannel scala tympani electrode array in the macaque. The American Journal of Otology. 16: 186-99. PMID 8572119  0.328
1995 Galvin KL, Cowan RS, Sarant JZ, Tobey EA, Blamey PJ, Clark GM. Articulation accuracy of children using an electrotactile speech processor. Ear and Hearing. 16: 209-19. PMID 7789672 DOI: 10.1097/00003446-199504000-00008  0.357
1995 van Hoesel RJ, Clark GM. Evaluation of a portable two-microphone adaptive beamforming speech processor with cochlear implant patients. The Journal of the Acoustical Society of America. 97: 2498-503. PMID 7714267 DOI: 10.1121/1.411970  0.346
1995 O'Leary SJ, Tong YC, Clark GM. Responses of dorsal cochlear nucleus single units to electrical pulse train stimulation of the auditory nerve with a cochlear implant electrode. The Journal of the Acoustical Society of America. 97: 2378-93. PMID 7714256 DOI: 10.1121/1.412977  0.385
1995 McKay CM, McDermott HJ, Clark GM. Pitch matching of amplitude-modulated current pulse trains by cochlear implantees: the effect of modulation depth. The Journal of the Acoustical Society of America. 97: 1777-85. PMID 7699159 DOI: 10.1121/1.412054  0.323
1995 Dawson PW, Blamey PJ, Dettman SJ, Barker EJ, Clark GM. A clinical report on receptive vocabulary skills in cochlear implant users. Ear and Hearing. 16: 287-94. PMID 7672477 DOI: 10.1097/00003446-199506000-00005  0.388
1995 Clark GM, Shute SA, Shepherd RK, Carter TD. Cochlear implantation: osteoneogenesis, electrode-tissue impedance, and residual hearing. The Annals of Otology, Rhinology & Laryngology. Supplement. 166: 40-2. PMID 7668722  0.328
1995 Vandali AE, Harrison JM, Huigen JM, Plant K, Clark GM. Multichannel cochlear implant speech processing: further variations of the spectral maxima sound processor strategy. The Annals of Otology, Rhinology & Laryngology. Supplement. 166: 378-81. PMID 7668714  0.31
1995 Au D, Bruce I, Irlicht L, Clark GM. Cross-fiber interspike interval probability distribution in acoustic stimulation: a computer modeling study. The Annals of Otology, Rhinology & Laryngology. Supplement. 166: 346-9. PMID 7668700  0.481
1995 Clark GM, McAnally KI, Black RC, Shepherd RK. Electrical stimulation of residual hearing in the implanted cochlea. The Annals of Otology, Rhinology & Laryngology. Supplement. 166: 111-3. PMID 7668596  0.33
1995 Irlicht LS, Clark GM. Control strategies for neurons modeled by self‐exciting point processes Journal of the Acoustical Society of America. 100: 3237-3247. DOI: 10.1121/1.417207  0.427
1994 Burton MJ, Shepherd RK, Xu SA, Xu J, Franz BK, Clark GM. Cochlear implantation in young children: histological studies on head growth, leadwire design, and electrode fixation in the monkey model. The Laryngoscope. 104: 167-75. PMID 8302119 DOI: 10.1288/00005537-199402000-00008  0.431
1994 Busby PA, Whitford LA, Blamey PJ, Richardson LM, Clark GM. Pitch perception for different modes of stimulation using the Cochlear multiple-electrode prosthesis Journal of the Acoustical Society of America. 95: 2658-2669. PMID 8207139 DOI: 10.1121/1.409835  0.402
1994 Shepherd RK, Xu SA, Clark GM. Partial hearing loss in the macaque following the co-administration of kanamycin and ethacrynic acid. Hearing Research. 72: 89-98. PMID 8150749 DOI: 10.1016/0378-5955(94)90209-7  0.317
1994 McKay CM, Vandali AE, McDermott HJ, Clark GM. Speech processing for multichannel cochlear implants: variations of the Spectral Maxima Sound Processor strategy. Acta Oto-Laryngologica. 114: 52-8. PMID 8128854 DOI: 10.3109/00016489409126016  0.434
1994 O'Leary SJ, Tong YC, Clark GM. Neural processes in the dorsal cochlear nucleus of the anaesthetised cat investigated from unit responses to electrical stimulation of the auditory nerve. Hearing Research. 74: 181-96. PMID 8040087 DOI: 10.1016/0378-5955(94)90186-4  0.368
1994 McKay CM, McDermott HJ, Clark GM. Pitch percepts associated with amplitude-modulated current pulse trains in cochlear implantees. The Journal of the Acoustical Society of America. 96: 2664-73. PMID 7983272 DOI: 10.1121/1.411377  0.398
1994 McAnally KI, Clark GM. Stimulation of residual hearing in the cat by pulsatile electrical stimulation of the cochlea. Acta Oto-Laryngologica. 114: 366-72. PMID 7976307 DOI: 10.3109/00016489409126071  0.382
1994 Seldon HL, Dahm MC, Clark GM, Crowe S. Silastic with polyacrylic acid filler: swelling properties, biocompatibility and potential use in cochlear implants. Biomaterials. 15: 1161-9. PMID 7893919 DOI: 10.1016/0142-9612(94)90237-2  0.411
1994 Dahm MC, Clark GM, Franz BK, Shepherd RK, Burton MJ, Robins-Browne R. Cochlear implantation in children: labyrinthitis following pneumococcal otitis media in unimplanted and implanted cat cochleas. Acta Oto-Laryngologica. 114: 620-5. PMID 7879619 DOI: 10.3109/00016489409126115  0.397
1994 Sarant JZ, Cowan RS, Blamey PJ, Galvin KL, Clark GM. Cochlear implants for congenitally deaf adolescents: is open-set speech perception a realistic expectation? Ear and Hearing. 15: 400-3. PMID 7813826 DOI: 10.1097/00003446-199410000-00007  0.409
1994 Rickards FW, Tan LE, Cohen LT, Wilson OJ, Drew JH, Clark GM. Auditory steady-state evoked potential in newborns. British Journal of Audiology. 28: 327-37. PMID 7757032 DOI: 10.3109/03005369409077316  0.303
1994 Shepherd RK, Matsushima J, Martin RL, Clark GM. Cochlear pathology following chronic electrical stimulation of the auditory nerve: II. Deafened kittens. Hearing Research. 81: 150-66. PMID 7737922 DOI: 10.1016/0378-5955(94)90162-7  0.473
1993 Xu SA, McAnally KI, Xu J, Clark GM. Comparison of half-band and full-band electrodes for intracochlear electrical stimulation. The Annals of Otology, Rhinology, and Laryngology. 102: 363-7. PMID 8489166 DOI: 10.1177/000348949310200508  0.358
1993 Xu J, Shepherd RK, Xu SA, Seldon HL, Clark GM. Pediatric cochlear implantation. Radiologic observations of skull growth. Archives of Otolaryngology--Head & Neck Surgery. 119: 525-34. PMID 8484942 DOI: 10.1001/Archotol.1993.01880170049010  0.41
1993 Shepherd RK, Hatsushika S, Clark GM. Electrical stimulation of the auditory nerve: the effect of electrode position on neural excitation. Hearing Research. 66: 108-20. PMID 8473242 DOI: 10.1016/0378-5955(93)90265-3  0.426
1993 Busby PA, Tong YC, Clark GM. Electrode position, repetition rate, and speech perception by early- and late-deafened cochlear implant patients. The Journal of the Acoustical Society of America. 93: 1058-67. PMID 8445117 DOI: 10.1121/1.405554  0.448
1993 Dooley GJ, Blamey PJ, Seligman PM, Alcantara JI, Clark GM, Shallop JK, Arndt P, Heller JW, Menapace CM. Combined electrical and acoustical stimulation using a bimodal prosthesis. Archives of Otolaryngology--Head & Neck Surgery. 119: 55-60. PMID 8417744 DOI: 10.1001/ARCHOTOL.1993.01880130057007  0.449
1993 Dahm MC, Shepherd RK, Clark GM. The postnatal growth of the temporal bone and its implications for cochlear implantation in children. Acta Oto-Laryngologica. Supplementum. 505: 1-39. PMID 8379315 DOI: 10.3109/00016489309128539  0.404
1993 Ni D, Seldon HL, Shepherd RK, Clark GM. Effect of chronic electrical stimulation on cochlear nucleus neuron size in normal hearing kittens. Acta Oto-Laryngologica. 113: 489-97. PMID 8379304 DOI: 10.3109/00016489309135851  0.457
1993 Busby PA, Tong YC, Clark GM. The perception of temporal modulations by cochlear implant patients. The Journal of the Acoustical Society of America. 94: 124-31. PMID 8354754 DOI: 10.1121/1.408212  0.346
1993 McAnally KI, Clark GM, Syka J. Hair cell mediated responses of the auditory nerve to sinusoidal electrical stimulation of the cochlea in the cat. Hearing Research. 67: 55-68. PMID 8340278 DOI: 10.1016/0378-5955(93)90232-P  0.382
1993 van Hoesel RJ, Tong YC, Hollow RD, Clark GM. Psychophysical and speech perception studies: a case report on a binaural cochlear implant subject. The Journal of the Acoustical Society of America. 94: 3178-89. PMID 8300953 DOI: 10.1121/1.407223  0.471
1993 Xu SA, Shepherd RK, Chen Y, Clark GM. Profound hearing loss in the cat following the single co-administration of kanamycin and ethacrynic acid. Hearing Research. 70: 205-15. PMID 8294265 DOI: 10.1016/0378-5955(93)90159-X  0.344
1993 Rance G, Rickards FW, Cohen LT, Burton MJ, Clark GM. Steady state evoked potentials: a new tool for the accurate assessment of hearing in cochlear implant candidates. Advances in Oto-Rhino-Laryngology. 48: 44-8. PMID 8273498 DOI: 10.1159/000422556  0.397
1993 O'Leary SJ, Tong YC, Clark GM. Responses from single units in the dorsal cochlear nucleus to electrical stimulation of the cochlea. Advances in Oto-Rhino-Laryngology. 48: 4-8. PMID 8273497 DOI: 10.1159/000422549  0.346
1993 Cowan RS, Dowell RC, Pyman BC, Dettman SJ, Dawson PW, Rance G, Barker EJ, Sarant JZ, Clark GM. Preliminary speech perception results for children with the 22-electrode Melbourne/cochlear hearing prosthesis. Advances in Oto-Rhino-Laryngology. 48: 231-5. PMID 8273486 DOI: 10.1159/000422589  0.418
1993 Richardson LM, Busby PA, Blarney PJ, Doweii RC, Clark GM. The effects of auditory feedback from the nucleus cochlear implant on the vowel formant frequencies produced by children and adults Ear and Hearing. 14: 339-349. PMID 8224577 DOI: 10.1097/00003446-199310000-00005  0.428
1993 McKay CM, McDermott HJ, Clark GM. Temporal pitch coding for cochlear implantees: The effects of carrier rate and amplitude modulation of pulsatile electrical stimuli The Journal of the Acoustical Society of America. 93: 2333-2333. DOI: 10.1121/1.406310  0.348
1993 Cohen LT, Clark GM, Whitford L. Forward masking patterns and pitch estimation for bipolar and remote ground stimulation in a subject implanted with a Cochlear Pty. Limited ‘‘20+2’’ cochlear implant The Journal of the Acoustical Society of America. 93: 2333-2333. DOI: 10.1121/1.406309  0.424
1992 Patrick JF, Clark GM. The Nucleus 22-channel cochlear implant system. Ear and Hearing. 12: 3S-9S. PMID 1955088 DOI: 10.1097/00003446-199108001-00002  0.436
1992 Cowan RS, Blamey PJ, Alcántara JI, Blombery PA, Hopkins IJ, Whitford LA, Clark GM. Safety studies with the University of Melbourne multichannel electrotactile speech processor. Journal of Rehabilitation Research and Development. 29: 35-52. PMID 1740777 DOI: 10.1682/JRRD.1992.01.0035  0.363
1992 Brown M, Shepherd RK, Webster WR, Martin RL, Clark GM. Cochleotopic selectivity of a multichannel scala tympani electrode array using the 2-deoxyglucose technique. Hearing Research. 59: 224-40. PMID 1618713 DOI: 10.1016/0378-5955(92)90119-8  0.409
1992 Busby PA, Tong YC, Clark GM. Psychophysical studies using a multiple-electrode cochlear implant in patients who were deafened early in life. Audiology : Official Organ of the International Society of Audiology. 31: 95-111. PMID 1610317 DOI: 10.3109/00206099209072905  0.396
1992 Dawson PW, Blamey PJ, Rowland LC, Dettman SJ, Clark GM, Busby PA, Brown AM, Dowell RC, Rickards FW. Cochlear implants in children, adolescents, and prelinguistically deafened adults: speech perception. Journal of Speech and Hearing Research. 35: 401-17. PMID 1573879 DOI: 10.1044/JSHR.3502.401  0.424
1992 Blamey PJ, Pyman BC, Gordon M, Clark GM, Brown AM, Dowell RC, Hollow RD. Factors predicting postoperative sentence scores in postlinguistically deaf adult cochlear implant patients. The Annals of Otology, Rhinology, and Laryngology. 101: 342-8. PMID 1562140 DOI: 10.1177/000348949210100410  0.446
1992 McKay CM, McDermott HJ, Vandali AE, Clark GM. A comparison of speech perception of cochlear implantees using the Spectral Maxima Sound Processor (SMSP) and the MSP (MULTIPEAK) processor. Acta Oto-Laryngologica. 112: 752-61. PMID 1456029 DOI: 10.3109/00016489209137470  0.416
1992 Burton MJ, Cohen LT, Rickards FW, Mcnally KI, Clark GM. Steady-state evoked potentials to amplitude modulated tones in the monkey Acta Oto-Laryngologica. 112: 745-751. PMID 1456028 DOI: 10.3109/00016489209137469  0.331
1992 Millard RE, McAnally KI, Clark GM. A gated differential amplifier for recording physiological responses to electrical stimulation. Journal of Neuroscience Methods. 44: 81-4. PMID 1434753 DOI: 10.1016/0165-0270(92)90116-U  0.343
1992 Ni D, Shepherd RK, Seldon HL, Xu SA, Clark GM, Millard RE. Cochlear pathology following chronic electrical stimulation of the auditory nerve. I: Normal hearing kittens. Hearing Research. 62: 63-81. PMID 1429252 DOI: 10.1016/0378-5955(92)90203-Y  0.479
1991 Cowan RS, Blamey PJ, Sarant JZ, Galvin KL, Alcantara JI, Whitford LA, Clark GM. Role of a multichannel electrotactile speech processor in a cochlear implant program for profoundly hearing-impaired adults. Ear and Hearing. 12: 39-46. PMID 2026287 DOI: 10.1097/00003446-199102000-00005  0.428
1991 Webb RL, Lehnhardt E, Clark GM, Laszig R, Pyman BC, Franz BK. Surgical complications with the cochlear multiple-channel intracochlear implant: experience at Hannover and Melbourne. The Annals of Otology, Rhinology, and Laryngology. 100: 131-6. PMID 1992899 DOI: 10.1177/000348949110000208  0.388
1991 Clark GM, Cohen NL, Shepherd RK. Surgical and safety considerations of multichannel cochlear implants in children. Ear and Hearing. 12: 15S-24S. PMID 1955086 DOI: 10.1097/00003446-199108001-00004  0.387
1991 Shepherd RK, Clark GM. Scanning electron microscopy of platinum scala tympani electrodes following chronic stimulation in patients. Biomaterials. 12: 417-23. PMID 1888811 DOI: 10.1016/0142-9612(91)90011-X  0.381
1991 Cowan RS, Blamey PJ, Sarant JZ, Galvin KL, Clark GM. Perception of multiple electrode stimulus patterns: implications for design of an electrotactile speech processor. The Journal of the Acoustical Society of America. 89: 360-8. PMID 1825833 DOI: 10.1121/1.400471  0.38
1991 Matsushima JI, Shepherd RK, Seldon HL, Xu SA, Clark GM. Electrical stimulation of the auditory nerve in deaf kittens: effects on cochlear nucleus morphology. Hearing Research. 56: 133-42. PMID 1769908 DOI: 10.1016/0378-5955(91)90162-3  0.439
1991 Shepherd RK, Matsushima J, Millard RE, Clark GM. Cochlear pathology following chronic electrical stimulation using non charge balanced stimuli. Acta Oto-Laryngologica. 111: 848-60. PMID 1759570 DOI: 10.3109/00016489109138421  0.367
1991 Busby PA, Roberts SA, Tong YC, Clark GM. Results of speech perception and speech production training for three prelingually deaf patients using a multiple-electrode cochlear implant. British Journal of Audiology. 25: 291-302. PMID 1742555 DOI: 10.3109/03005369109076601  0.411
1991 Seldon HL, Clark GM. Human cochlear nucleus: comparison of Nissl-stained neurons from deaf and hearing patients. Brain Research. 551: 185-94. PMID 1717104 DOI: 10.1016/0006-8993(91)90932-L  0.357
1991 McAnally KI, Clark GM. Electrophonic excitation from electrical stimulation of the hearing‐impaired cochlea of the cat. Journal of the Acoustical Society of America. 90: 2291-2291. DOI: 10.1121/1.401147  0.315
1990 Tong YC, Harrison JM, Huigen J, Clark GM. Comparison of Two Speech Processing Schemes Using Normal-hearing Subjects. Acta Oto-Laryngologica. 109: 135-139. PMID 31905520 DOI: 10.1080/00016489.1990.12088420  0.301
1990 Busby PA, Tong YC, Roberts SA, Altidis PM, Dettman SJ, Blamey PJ, Clark GM, Watson RK, Dowell RC, Rickards FW. Results for two children using a multiple-electrode intracochlear implant. The Journal of the Acoustical Society of America. 86: 2088-102. PMID 2600299 DOI: 10.1121/1.398468  0.327
1990 Blamey PJ, Clark GM. Place coding of vowel formants for cochlear implant patients. The Journal of the Acoustical Society of America. 88: 667-73. PMID 2212290 DOI: 10.1121/1.399770  0.413
1990 Blamey PJ, Clark GM, Tong YC, Ling D. Perceptual-oral training of two hearing-impaired children in the recognition and production of /s/ and /z/. British Journal of Audiology. 24: 375-9. PMID 2149081 DOI: 10.3109/03005369009076578  0.339
1990 Blamey PJ, Alcantara JI, Cowan RS, Galvin KL, Sarant JZ, Clark GM. Perception of amplitude envelope variations of pulsatile electrotactile stimuli. The Journal of the Acoustical Society of America. 88: 1765-72. PMID 2148175 DOI: 10.1121/1.400197  0.445
1990 Cowan RS, Blamey PJ, Galvin KL, Sarant JZ, Alcántara JI, Clark GM. Perception of sentences, words, and speech features by profoundly hearing-impaired children using a multichannel electrotactile speech processor. The Journal of the Acoustical Society of America. 88: 1374-84. PMID 2146297 DOI: 10.1121/1.399715  0.387
1990 Alcantara JI, Cowan RS, Blamey PJ, Clark GM. A comparison of two training strategies for speech recognition with an electrotactile speech processor. Journal of Speech and Hearing Research. 33: 195-204. PMID 2138238 DOI: 10.1044/JSHR.3301.195  0.301
1990 O'Leary SJ, Tong YC, Clark GM. Dorsal cochlear nucleus responses to electrical stimulation of the auditory nerve Journal of the Acoustical Society of America. 88. DOI: 10.1121/1.2028868  0.354
1990 van Hoesel R, Tong YC, Hollow RD, Huigen JM, Clark GM. Preliminary studies on a bilateral cochlear implant user The Journal of the Acoustical Society of America. 88: S193-S193. DOI: 10.1121/1.2028867  0.471
1989 Lim HH, Tong YC, Clark GM. Forward masking patterns produced by intracochlear electrical stimulation of one and two electrode pairs in the human cochlea. The Journal of the Acoustical Society of America. 86: 971-80. PMID 2794250 DOI: 10.1121/1.398732  0.379
1989 Franz BK, Kuzma JA, Lehnhardt E, Clark GM, Patrick JF, Laszig R. Implantation of the Melbourne/Cochlear multiple-electrode extracochlear prosthesis. The Annals of Otology, Rhinology, and Laryngology. 98: 591-6. PMID 2764441 DOI: 10.1177/000348948909800804  0.427
1989 Cowan RS, Alcantara JI, Whitford LA, Blamey PJ, Clark GM. Speech perception studies using a multichannel electrotactile speech processor, residual hearing, and lipreading. The Journal of the Acoustical Society of America. 85: 2593-607. PMID 2526169 DOI: 10.1121/1.397754  0.39
1989 Franz B, Busby P, Brown A, Clark G. PRINCIPLE OF THE AUSTRALIAN MULTIPLEELECTRODE COCHLEAR IMPLANT Nippon Jibiinkoka Gakkai Kaiho. 92: 1755a-1757. DOI: 10.3950/JIBIINKOKA.92.10SOKAI_1755A  0.401
1989 Cowan SC, Blamey PJ, Alcantara JI, Whitford LA, Clark G, Plant G. Speech feature encoding through an electrotactile speech processor Robert The Journal of the Acoustical Society of America. 86: S83-S83. DOI: 10.1121/1.2027685  0.321
1989 Lai WK, Tong YC, Millar JB, Clark GM, van Hoesel R. Perceptual independence of pulse rates used in speech coding schemes for a multichannel cochlear implant The Journal of the Acoustical Society of America. 86: S82-S82. DOI: 10.1121/1.2027680  0.45
1989 Alcantara JI, Whitford LA, Blamey PJ, Cowan RSC, Clark GM. Speech feature recognition by profoundly deaf children using the University of Melbourne multichannel electrotactile aid The Journal of the Acoustical Society of America. 86: S81-S81. DOI: 10.1121/1.2027677  0.346
1989 Busby PA, Tong YC, Clark GM, Alcantara JI. Psychophysical studies on cochlear implant patients deafened prior to 4 years of age The Journal of the Acoustical Society of America. 86: S81-S81. DOI: 10.1121/1.2027676  0.382
1989 Dawson PW, Blamey PJ, Clark GM, Busby PA, Rowland LC, Dettman SJ, Brown AM, Dowell RC, Rickards FW, Alcantara JI. Results in children using the 22‐electrode cochlear implant The Journal of the Acoustical Society of America. 86: S81-S81. DOI: 10.1121/1.2027675  0.412
1988 Dowell RC, Seligman PM, Blamey PJ, Clark GM. Speech perception using a two-formant 22-electrode cochlear prosthesis in quiet and in noise. Acta Oto-Laryngologica. 104: 439-46. PMID 3434265 DOI: 10.3109/00016488709128272  0.412
1988 Franz BKHG, Clark GM. The surgical anatomy for multiple-electrode extracochlear implant operations The Journal of Laryngology &Amp; Otology. 102: 685-688. PMID 3418219 DOI: 10.1017/S0022215100106152  0.378
1988 Busby PA, Tong YC, Clark GM. Underlying structure of auditory-visual consonant perception by hearing-impaired children and the influences of syllabic compression. Journal of Speech and Hearing Research. 31: 156-65. PMID 3398489 DOI: 10.1044/JSHR.3102.156  0.328
1988 Blamey PJ, Cowan RS, Alcantara JI, Clark GM. Phonemic information transmitted by a multichannel electrotactile speech processor. Journal of Speech and Hearing Research. 31: 620-9. PMID 3230892 DOI: 10.1044/JSHR.3104.620  0.376
1988 Tong YC, Busby PA, Clark GM. Perceptual studies on cochlear implant patients with early onset of profound hearing impairment prior to normal development of auditory, speech, and language skills. The Journal of the Acoustical Society of America. 84: 951-62. PMID 3183213 DOI: 10.1121/1.396664  0.483
1988 Tong YC, Lim HH, Clark GM. Synthetic vowel studies on cochlear implant patients. The Journal of the Acoustical Society of America. 84: 876-87. PMID 3183206 DOI: 10.1121/1.396657  0.399
1988 Clark GM, Shepherd RK, Franz BK, Dowell RC, Tong YC, Blamey PJ, Webb RL, Pyman BC, McNaughtan J, Bloom DM. The histopathology of the human temporal bone and auditory central nervous system following cochlear implantation in a patient. Correlation with psychophysics and speech perception results. Acta Oto-Laryngologica. Supplementum. 448: 1-65. PMID 3176974 DOI: 10.3109/00016488809098972  0.414
1988 Clark GM, Blamey PJ, Brown AM, Busby PA, Dowell RC, Franz BK, Millar JB, Pyman BC, Shepherd RK, Tong YC. The University of Melbourne/Nucleus cochlear prosthesis. The Australian and New Zealand Journal of Surgery. 58: 89-102. PMID 3046594 DOI: 10.1111/J.1445-2197.1988.Tb01017.X  0.335
1988 Cowan RS, Alcantara JI, Blamey PJ, Clark GM. Preliminary evaluation of a multichannel electrotactile speech processor. The Journal of the Acoustical Society of America. 83: 2328-38. PMID 2970485 DOI: 10.1121/1.396364  0.364
1988 Blamey PJ, Clark GM, Dowell RC. Speech perception with cochlear implants and tactile aids The Journal of the Acoustical Society of America. 84: S41-S41. DOI: 10.1121/1.2026305  0.413
1987 Cowan RS, Alcantara JI, Blamey PJ, Clark GM. Interim results of open-set speech discrimination with a wearable multichannel electrotactile speech processor [43.66.Ts, 43.66. Yw] Journal of the Acoustical Society of America. 82: 1456-1457. PMID 3680785 DOI: 10.1121/1.395231  0.33
1987 Blamey PJ, Dowell RC, Brown AM, Clark GM, Seligman PM. Vowel and consonant recognition of cochlear implant patients using formant-estimating speech processors. The Journal of the Acoustical Society of America. 82: 48-57. PMID 3624640 DOI: 10.1121/1.395436  0.4
1987 Blamey PJ, Dowell RC, Clark GM, Seligman PM. Acoustic parameters measured by a formant-estimating speech processor for a multiple-channel cochlear implant. The Journal of the Acoustical Society of America. 82: 38-47. PMID 3624639 DOI: 10.1121/1.395542  0.381
1987 Clark GM, Blamey PJ, Busby PA, Dowell RC, Franz B, Musgrave GN, Nienhuys TG, Pyman BC, Roberts SA, Tong YC, Webb RL, Kuzma JA, Money DK, Patrick JF, Seligman PM. A Multiple-Electrode Intracochlear Implant for Children Archives of Otolaryngology--Head and Neck Surgery. 113: 825-828. PMID 3620142 DOI: 10.1001/archotol.1987.01860080031010  0.404
1987 Franz BK, Clark GM, Bloom DM. Surgical anatomy of the round window with special reference to cochlear implantation. The Journal of Laryngology and Otology. 101: 97-102. PMID 3572226 DOI: 10.1017/S0022215100101343  0.393
1987 Franz BK, Clark GM, Bloom DM. Effect of experimentally induced otitis media on cochlear implants. The Annals of Otology, Rhinology, and Laryngology. 96: 174-7. PMID 3551743 DOI: 10.1177/000348948709600207  0.372
1987 Blamey PJ, Clark GM. Psychophysical studies relevant to the design of a digital electrotactile speech processor. The Journal of the Acoustical Society of America. 82: 116-25. PMID 2957405 DOI: 10.1121/1.395555  0.383
1987 Dowell RC, Seligman PM, Blamey PJ, Clark GM. Evaluation of a Two-Formant Speech-Processing Strategy for a Multichannel Cochlear Prosthesis Annals of Otology, Rhinology & Laryngology. 96: 132-134. DOI: 10.1177/00034894870960S171  0.443
1987 Brown AM, Dowell RC, Clark GM. Clinical Results for Postlingually Deaf Patients Implanted with Multichannel Cochlear Prostheses Annals of Otology, Rhinology & Laryngology. 96: 127-128. DOI: 10.1177/00034894870960S168  0.389
1987 Xu SA, Dowell RC, Clark GM. Results for Chinese and English in a Multichannel Cochlear Implant Patient Annals of Otology, Rhinology & Laryngology. 96: 126-127. DOI: 10.1177/00034894870960S167  0.41
1987 Busby PA, Dowell RC, Nienhuys TG, Clark GM. Audiological Assessment of Profoundly Hearing-Impaired Children Annals of Otology, Rhinology & Laryngology. 96: 85-86. DOI: 10.1177/00034894870960S143  0.362
1987 Nienhuys TG, Musgrave GN, Busby PA, Blamey PJ, Nott P, Tong YC, Dowell RC, Brown LF, Clark GM. Educational Assessment and Management of Children with Multichannel Cochlear Implants Annals of Otology, Rhinology & Laryngology. 96: 80-82. DOI: 10.1177/00034894870960S139  0.342
1987 Millar JB, Martin LFA, Tong YC, Clark GM. Temporal Coding of Speech Information for Cochlear Implant Patients Annals of Otology, Rhinology & Laryngology. 96: 62-64. DOI: 10.1177/00034894870960S129  0.332
1987 Berkowitz RG, Franz BK, Shepherd RK, Clark GM, Bloom DM. Pneumococcal Middle Ear Infection and Cochlear Implantation Annals of Otology, Rhinology & Laryngology. 96: 55-56. DOI: 10.1177/00034894870960S125  0.378
1987 Tong YC, Clark GM, Lim HH. Estimation of the Effective Spread of Neural Excitation Produced by a Bipolar Pair of Scala Tympani Electrodes Annals of Otology, Rhinology & Laryngology. 96: 37-38. DOI: 10.1177/00034894870960S115  0.404
1987 Javel E, Tong YC, Shepherd RK, Clark GM. Responses of Cat Auditory Nerve Fibers to Biphasic Electrical Current Pulses Annals of Otology, Rhinology & Laryngology. 96: 26-30. DOI: 10.1177/00034894870960S111  0.428
1987 Lukies PM, Tong YC, Clark GM. Current Distributions Produced by the Banded Electrode Array: An Experimental Study Conducted with a Tank Model Annals of Otology, Rhinology & Laryngology. 96: 24-25. DOI: 10.1177/00034894870960S110  0.334
1987 Franz BKG, Clark GM. Refined Surgical Technique for Insertion of Banded Electrode Array Annals of Otology, Rhinology & Laryngology. 96: 15-17. DOI: 10.1177/00034894870960S105  0.401
1987 Clark GM, Pyman BC, Webb RL, Franz BKG, Redhead TJ, Shepherd RK. Surgery for the Safe Insertion and Reinsertion of the Banded Electrode Array Annals of Otology, Rhinology & Laryngology. 96: 10-12. DOI: 10.1177/00034894870960S102  0.416
1987 Blamey P, Dowell R, Brown A, Clark G, Seligman P. A formant-estimating speech processor for cochlear implant patients Speech Communication. 6: 293-298. DOI: 10.1016/0167-6393(87)90003-3  0.433
1986 Blamey PJ, Dowell RC, Brown AM, Clark GM. Clinical results with a hearing aid and a single-channel vibrotactile device for profoundly deaf adults. British Journal of Audiology. 19: 203-10. PMID 4063556 DOI: 10.3109/03005368509078974  0.373
1986 Dowell RC, Mecklenburg DJ, Clark GM. Speech recognition for 40 patients receiving multichannel cochlear implants. Archives of Otolaryngology--Head & Neck Surgery. 112: 1054-9. PMID 3755975 DOI: 10.1001/ARCHOTOL.1986.03780100042005  0.408
1986 Dowell RC, Clark GM, Seligman PM, Brown AM. Perception of connected speech without lipreading, using a multi-channel hearing prosthesis. Acta Oto-Laryngologica. 102: 7-11. PMID 3755563 DOI: 10.3109/00016488609108639  0.387
1986 Tong YC, Clark GM. Loudness summation, masking, and temporal interaction for sensations produced by electric stimulation of two sites in the human cochlea. The Journal of the Acoustical Society of America. 79: 1958-66. PMID 3722606 DOI: 10.1121/1.393203  0.425
1986 Busby PA, Tong YC, Clark GM. Speech perception studies in the first year of usage of a multiple electrode cochlear implant by prelingual patients The Journal of the Acoustical Society of America. 80: S30-S30. DOI: 10.1121/1.2023745  0.353
1986 Tong YC, Busby PA, Clark GM. Psychophysical studies on prelingual patients using a multiple electrode cochlear implant The Journal of the Acoustical Society of America. 80: S30-S30. DOI: 10.1121/1.2023744  0.421
1986 Lukies PM, Tong YC, Clark GM, Busby PA. Modeling studies on current distributions produced by an Intracochlear electrode array The Journal of the Acoustical Society of America. 80: S30-S30. DOI: 10.1121/1.2023742  0.332
1986 Clark G. The University of Melbourne/Cochlear Corporation (Nucleus) Program Otolaryngologic Clinics of North America. 19: 329-354. DOI: 10.1016/S0030-6665(20)31774-6  0.41
1985 Shepherd RK, Clark GM. Progressive ototoxicity of neomycin monitored using derived brainstem response audiometry. Hearing Research. 18: 105-10. PMID 4044414 DOI: 10.1016/0378-5955(85)90001-2  0.321
1985 Shepherd RK, Murray MT, Houghton ME, Clark GM. Scanning electron microscopy of chronically stimulated platinum intracochlear electrodes. Biomaterials. 6: 237-42. PMID 3840392 DOI: 10.1016/0142-9612(85)90019-5  0.36
1985 Brennan WJ, Clark GM. An animal model of acute otitis media and the histopathological assessment of a cochlear implant in the cat. The Journal of Laryngology and Otology. 99: 851-6. PMID 3840192 DOI: 10.1017/S0022215100097802  0.331
1985 O'Leary SJ, Black RC, Clark GM. Current distributions in the cat cochlea: A modelling and electrophysiological study Hearing Research. 18: 273-281. PMID 3840160 DOI: 10.1016/0378-5955(85)90044-9  0.391
1985 Tong YC, Clark GM. Absolute identification of electric pulse rates and electrode positions by cochlear implant patients. The Journal of the Acoustical Society of America. 77: 1881-8. PMID 3839004 DOI: 10.1121/1.391939  0.396
1985 Brown AM, Clark GM, Dowell RC, Martin LF, Seligman PM. Telephone use by a multi-channel cochlear implant patient. An evaluation using open-set CID sentences. The Journal of Laryngology and Otology. 99: 231-8. PMID 3838331 DOI: 10.1017/S0022215100096614  0.361
1985 Shepherd RK, Clark GM, Pyman BC, Webb RL. Banded intracochlear electrode array: evaluation of insertion trauma in human temporal bones. The Annals of Otology, Rhinology, and Laryngology. 94: 55-9. PMID 3838226 DOI: 10.1177/000348948509400112  0.325
1985 Blamey PJ, Clark GM. A wearable multiple-electrode electrotactile speech processor for the profoundly deaf. The Journal of the Acoustical Society of America. 77: 1619-20. PMID 3157717 DOI: 10.1121/1.392009  0.365
1985 Patrick JF, Seligman P, Tong YC, Clark GM. Speech processing method and apparatus The Journal of the Acoustical Society of America. 78: 1928-1928. DOI: 10.1121/1.392722  0.436
1984 Busby PA, Tong YC, Clark GM. Underlying dimensions and individual differences in auditory, visual, and auditory-visual vowel perception by hearing-impaired children. The Journal of the Acoustical Society of America. 75: 1858-65. PMID 6747096 DOI: 10.1121/1.390987  0.303
1984 Blamey PJ, Dowell RC, Tong YC, Clark GM. An acoustic model of a multiple-channel cochlear implant. The Journal of the Acoustical Society of America. 76: 97-103. PMID 6547735 DOI: 10.1121/1.391012  0.393
1984 Blamey PJ, Dowell RC, Tong YC, Brown AM, Luscombe SM, Clark GM. Speech processing studies using an acoustic model of a multiple-channel cochlear implant. The Journal of the Acoustical Society of America. 76: 104-10. PMID 6547734 DOI: 10.1121/1.391104  0.461
1984 Millar JB, Tong YC, Clark GM. Speech processing for cochlear implant prostheses. Journal of Speech and Hearing Research. 27: 280-96. PMID 6547495 DOI: 10.1044/JSHR.2702.280  0.459
1984 Clark GM, Pyman BC, Webb RL, Bailey QE, Shepherd RK. Surgery for an improved multiple-channel cochlear implant. The Annals of Otology, Rhinology, and Laryngology. 93: 204-7. PMID 6547284 DOI: 10.1177/000348948409300302  0.404
1984 Clark GM, Tong YC, Patrick JF, Seligman PM, Crosby PA, Kuzma JA, Money DK. A multi-channel hearing prosthesis for profound-to-total hearing loss Journal of Medical Engineering and Technology. 8: 3-8. PMID 6546950 DOI: 10.3109/03091908409032065  0.453
1984 Clark GM, Tong YC, Dowell RC. Comparison of two cochlear implant speech-processing strategies. The Annals of Otology, Rhinology, and Laryngology. 93: 127-31. PMID 6546846 DOI: 10.1177/000348948409300205  0.315
1984 Shepherd RK, Webb RL, Clark GM, Pyman BC, Hirshorn MS, Murray MT, Houghton ME. Implanted material tolerance studies for a multiple-channel cochlear prosthesis. Acta Oto-Laryngologica. Supplementum. 411: 71-81. PMID 6441446 DOI: 10.3109/00016488409129740  0.457
1984 Clark GM, Dowell RC, Pyman BC, Brown AM, Webb RL, Tong YC, Bailey Q, Seligman PM. Clinical trial of a multi-channel cochlear prosthesis: results on 10 postlingually deaf patients. The Australian and New Zealand Journal of Surgery. 54: 519-26. PMID 6393936 DOI: 10.1111/J.1445-2197.1984.TB05439.X  0.359
1984 Dowell RC, Webb RL, Clark GM. Clinical Results Using a Multiple-channel Cochlear Prosthesis Acta Oto-Laryngologica. 98: 230-236. DOI: 10.3109/00016488409121698  0.368
1984 Seligman PM, Patrick JF, Tong YC, Clark GM, Dowell RC, Crosby PA. A Signal Processor for a Multiple-electrode Hearing Prosthesis Acta Oto-Laryngologica. 98: 135-139. DOI: 10.3109/00016488409099557  0.425
1984 Franz B, Clark GM, Bloom DM. Permeability of the implanted round window membrane in the cat: An investigation using horseradish peroxidase Acta Oto-Laryngologica. 98: 17-23. DOI: 10.3109/00016488409098960  0.364
1984 Clark GM, Shepherd RK. Cochlear Implant Round Window Sealing Procedures in the Cat:An Investigation of Autograft and Heterograft Materials Acta Oto-Laryngologica. 98: 5-15. DOI: 10.3109/00016488409098959  0.331
1983 Dowell RC, Martin LF, Tong YC, Clark GM, Seligman PM, Patrick JF. A 12-consonant confusion study on a multiple-channel cochlear implant patient. Journal of Speech and Hearing Research. 25: 509-16. PMID 6897661 DOI: 10.1044/JSHR.2504.509  0.413
1983 Tong YC, Dowell RC, Blamey PJ, Clark GM. Two-component hearing sensations produced by two-electrode stimulation in the cochlea of a deaf patient. Science (New York, N.Y.). 219: 993-4. PMID 6823564 DOI: 10.1126/SCIENCE.6823564  0.412
1983 Tong YC, Blamey PJ, Dowell RC, Clark GM. Psychophysical studies evaluating the feasibility of a speech processing strategy for a multiple-channel cochlear implant. The Journal of the Acoustical Society of America. 74: 73-80. PMID 6688434 DOI: 10.1121/1.389620  0.433
1983 Black RC, Steel AC, Clark GM. Amplitude and pulse rate difference limens for electrical stimulation of the cochlea following graded degeneration of the auditory nerve Acta Oto-Laryngologica. 95: 27-33. PMID 6687505 DOI: 10.3109/00016488309130912  0.397
1983 Tong YC, Clark GM. Percepts from scala tympani stimulation. Annals of the New York Academy of Sciences. 405: 264-7. PMID 6575650 DOI: 10.1111/j.1749-6632.1983.tb31639.x  0.407
1983 Clark GM, Shepherd RK, Patrick JF, Black RC, Tong YC. Design and fabrication of the banded electrode array. Annals of the New York Academy of Sciences. 405: 191-201. PMID 6575644 DOI: 10.1111/J.1749-6632.1983.Tb31632.X  0.329
1983 Black RC, Clark GM, Tong YC, Patrick JF. Current distributions in cochlear stimulation Annals of the New York Academy of Sciences. 137-145. PMID 6575639 DOI: 10.1111/j.1749-6632.1983.tb31626.x  0.404
1983 Black RC, Clark GM, O'leary SJ, Walters C. Intracochlear electrical stimulation of normal and DEAF CATS investigated using brainstem response audiometry Acta Oto-Laryngologica. 95: 5-17. PMID 6316713 DOI: 10.3109/00016488309105588  0.405
1983 Shepherd RK, Clark GM, Black RC. Chronic electrical stimulation of the auditory nerve in cats. Physiological and histopathological results. Acta Oto-Laryngologica. Supplementum. 399: 19-31. PMID 6316712 DOI: 10.3109/00016488309105589  0.425
1983 Martin LF, Dowell RC, Clark GM. Preoperative hearing and evaluations for cochlear implant patients. A preliminary report using a Minimal Auditory Capabilities battery. Scandinavian Audiology. 12: 119-24. PMID 6225181 DOI: 10.3109/01050398309076234  0.452
1982 Clark GM, Tong YC. A multiple-channel cochlear implant. A summary of results for two patients. Archives of Otolaryngology (Chicago, Ill. : 1960). 108: 214-7. PMID 6896141 DOI: 10.1001/ARCHOTOL.1982.00790520014005  0.46
1982 Tong YC, Clark GM, Dowell RC, Martin LF, Seligman PM, Patrick JF. A multiple-channel cochlear implant and wearable speech-processor: an audiological evaluation. Acta Oto-Laryngologica. 92: 193-8. PMID 6895683 DOI: 10.3109/00016488109133256  0.376
1982 Tong YC, Clark GM, Blamey PJ, Busby PA, Dowell RC. Psychophysical studies for two multiple-channel cochlear implant patients. The Journal of the Acoustical Society of America. 71: 153-60. PMID 6895638 DOI: 10.1121/1.387342  0.439
1981 Black RC, Clark GM, Patrick JF. Current Distribution Measurements Within the Human Cochlea Ieee Transactions On Biomedical Engineering. 721-725. PMID 7319508 DOI: 10.1109/TBME.1981.324668  0.394
1981 Clark GM, Tong YC, Martin LF. A multiple-channel cochlear implant: an evaluation using open-set CID sentences. The Laryngoscope. 91: 628-34. PMID 7219008 DOI: 10.1288/00005537-198104000-00018  0.427
1981 Clark GM, Tong YC. Multiple-electrode cochlear implant for profound or total hearing loss: a review. The Medical Journal of Australia. 1: 428-9. PMID 7019645 DOI: 10.5694/J.1326-5377.1981.TB135697.X  0.443
1981 Clark GM, Tong YC, Martin LF, Busby PA, Dowell RC, Seligman PM, Patrick JF. A multiple-channel cochlear implant: An evaluation using nonsense syllables Annals of Otology, Rhinology &Amp; Laryngology. 90: 227-230. PMID 6895008 DOI: 10.1177/000348948109000306  0.404
1981 Clark GM, Tong YC, Martin LF, Busby PA. A multiple-channel cochlear implant. An evaluation using an open-set word test. Acta Oto-Laryngologica. 91: 173-5. PMID 6894818 DOI: 10.3109/00016488109138496  0.435
1981 Clark GM, Tong YC, Martin LF. A multiple-channel cochlear implant: an evaluation using closed-set spondaic words. The Journal of Laryngology and Otology. 95: 461-4. PMID 6894608 DOI: 10.1017/S0022215100090964  0.334
1981 Martin LF, Tong YC, Clark GM. A multiple-channel cochlear implant. Evaluation using speech tracking. Archives of Otolaryngology (Chicago, Ill. : 1960). 107: 157-9. PMID 6894085 DOI: 10.1001/ARCHOTOL.1981.00790390023007  0.414
1981 Tong YC, Clark GM, Seligman PM, Patrick JF. Speech processing for a multiple-electrode cochlear implant hearing prosthesis. The Journal of the Acoustical Society of America. 68: 1897-8. PMID 6893993 DOI: 10.1121/1.385184  0.304
1981 Clark GM, Pyman BC, Pavillard RE. A protocol for the prevention of infection in cochlear implant surgery. The Journal of Laryngology and Otology. 94: 1377-86. PMID 6893717 DOI: 10.1017/S0022215100090204  0.314
1981 Blamey PJ, Tong YC, Dowell RC, Clark GM. Pitch and loudness studies on a multipie‐channel cochlear implant patient The Journal of the Acoustical Society of America. 70: S53-S53. DOI: 10.1121/1.2018919  0.325
1981 Dowell RC, Tong JC, Blamey PJ, Clark GM. Perceptual dissimilarity and discrimination studies using two‐electrode stimulation with a multiple‐channel cochlear implant patient The Journal of the Acoustical Society of America. 70: S53-S53. DOI: 10.1121/1.2018918  0.427
1981 Tong YC, Blamey PJ, Dowell RC, Clark GM. The effects of electrode position and stimulus period on the hearing sensations in a multiple‐channel cochlear implant patient The Journal of the Acoustical Society of America. 70: S52-S53. DOI: 10.1121/1.2018917  0.396
1980 Tong YC, Millar JB, Clark GM, Martin LF, Busby PA, Patrick JF. Psychophysical and speech perception studies on two multiple channel cochlear implant patients The Journal of Laryngology &Amp; Otology. 94: 1241-1256. PMID 6893715 DOI: 10.1017/S002221510009006X  0.383
1980 Black RC, Clark GM. Differential electrical excitation of the auditory nerve Journal of the Acoustical Society of America. 67: 868-874. PMID 6892642 DOI: 10.1121/1.383966  0.386
1980 Nienhuys TG, Clark GM. Critical bands following the selective destruction of cochlear inner and outer hair cells. Acta Oto-Laryngologica. 88: 350-8. PMID 532610 DOI: 10.3109/00016487909137179  0.301
1979 Tong YC, Black RC, Clark GM, Forster IC, Millar JB, O'Loughlin BJ, Patrick JF. A preliminary report on a multiple-channel cochlear implant operation Journal of Laryngology and Otology. 93: 679-695. PMID 469398 DOI: 10.1017/S0022215100087545  0.415
1979 Clark GM, Pyman BC, Bailey QR. The surgery for multiple-electrode cochlear implantations. The Journal of Laryngology and Otology. 93: 215-23. PMID 429901 DOI: 10.1017/S0022215100086977  0.38
1979 Clark GM, Patrick JF, Bailey Q. A cochlear implant round window electrode array. The Journal of Laryngology and Otology. 93: 107-9. PMID 429893 DOI: 10.1017/S0022215100086825  0.439
1978 Clark GM, Black R, Forster IC, Patrick JF, Tong YC. Design criteria of a multiple-electrode cochlear implant hearing prosthesis [43.66.Ts, 43.66.Sr]. The Journal of the Acoustical Society of America. 63: 631-3. PMID 670554 DOI: 10.1121/1.2033198  0.441
1978 Clark GM. COCHLEAR IMPLANT SURGERY FOR PROFOUND OR TOTAL HEARING LOSS Medical Journal of Australia. 2: 587-588. DOI: 10.5694/j.1326-5377.1978.tb131753.x  0.388
1977 Clark GM, O'Laughlin BJ, Rickards FW, Tong YC, Williams AJ. The clinical assessment of cochlear implant patients. The Journal of Laryngology and Otology. 91: 697-708. PMID 894122 DOI: 10.1017/S0022215100084231  0.35
1977 Clark GM, Tong YC, Black R, Forster IC, Patrick JF, Dewhurst DJ. A multiple electrode cochlear implant. The Journal of Laryngology and Otology. 91: 935-45. PMID 591780 DOI: 10.1017/S0022215100084607  0.44
1977 Clark GM. An evaluation of per-scalar cochlear electrode implantation techniques The Journal of Laryngology & Otology. 91: 185-199. DOI: 10.1017/S0022215100083560  0.385
1976 Clark GM, Hallworth RJ. A multiple-electrode array for a cochlear implant. The Journal of Laryngology and Otology. 90: 623-7. PMID 956705 DOI: 10.1017/S0022215100082529  0.714
1976 Williams AJ, Clark GM, Stanley GV. Pitch discrimination in the cat through electrical stimulation of the terminal auditory nerve fibers Psychobiology. 4: 23-27. DOI: 10.3758/Bf03326539  0.426
1975 Clark GM, Hallworth RJ, Zdanius K. A cochlear implant electrode. The Journal of Laryngology and Otology. 89: 787-92. PMID 1185061 DOI: 10.1017/S0022215100081020  0.726
1975 Clark GM. A surgical approach for a cochlear implant: an anatomical study. The Journal of Laryngology and Otology. 89: 9-15. PMID 1113035 DOI: 10.1017/S0022215100080038  0.43
1975 Clark GM, Kranz HG, Minas H, Nathar JM. Histopathological findings in cochlear implants in cats. The Journal of Laryngology and Otology. 89: 495-504. PMID 1097552 DOI: 10.1017/S002221510008066X  0.45
1974 Clark GM. A hearing prosthesis for severe perceptive deafness--experimental studies. The Journal of Laryngology and Otology. 87: 929-45. PMID 4593743 DOI: 10.1017/S0022215100077859  0.313
1973 Clark GM, Kranz HG, Minas H. Behavioral thresholds in the cat to frequency modulated sound and electrical stimulation of the auditory nerve. Experimental Neurology. 41: 190-200. PMID 4743485 DOI: 10.1016/0014-4886(73)90189-1  0.359
1972 Clark GM, Nathar JM, Kranz HG, Maritz JS. A behavioral study on electrical stimulation of the cochlea and central auditory pathways of the cat. Experimental Neurology. 36: 350-61. PMID 5053357 DOI: 10.1016/0014-4886(72)90029-5  0.379
1971 Clark GM, Dunlop CW. Extracranial auditory responses from the base of the skull. The Laryngoscope. 80: 1834-46. PMID 5491068 DOI: 10.1002/LARY.5540801205  0.306
1969 Clark GM. HEARING DUE TO ELECTRICAL STIMULATION OF THE AUDITORY SYSTEM Medical Journal of Australia. 1: 1346-1348. DOI: 10.5694/j.1326-5377.1969.tb62399.x  0.392
Show low-probability matches.