Marinna Salluzzi - Publications

Affiliations: 
2006-2010 Electrical Engineering University of Calgary, Calgary, Alberta, Canada 

9 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2020 McCreary CR, Salluzzi M, Andersen LB, Gobbi D, Lauzon L, Saad F, Smith EE, Frayne R. Calgary Normative Study: design of a prospective longitudinal study to characterise potential quantitative MR biomarkers of neurodegeneration over the adult lifespan. Bmj Open. 10: e038120. PMID 32792445 DOI: 10.1136/Bmjopen-2020-038120  0.477
2019 Bento M, Souza R, Salluzzi M, Rittner L, Zhang Y, Frayne R. Automatic identification of atherosclerosis subjects in a heterogeneous MR brain imaging data set. Magnetic Resonance Imaging. PMID 31228556 DOI: 10.1016/J.Mri.2019.06.007  0.392
2016 Lauzon ML, McCreary CR, McLean DA, Salluzzi M, Frayne R. Quantitative susceptibility mapping at 3 T: comparison of acquisition methodologies. Nmr in Biomedicine. PMID 26887659 DOI: 10.1002/Nbm.3492  0.538
2011 Gauderon P, Salluzzi M, Lauzon M, McCreary C, Smith M, Frayne R. SU-E-I-132: Whole-Brain DCE Quantitative Perfusion Imaging Medical Physics. 38: 3426-3426. DOI: 10.1118/1.3611706  0.553
2008 Smith M, Salluzzi M, Frayne R. Obtaining DSC MRI cerebral blood flow estimates without tissue specific errors Iet Conference Publications. DOI: 10.1049/cp:20080456  0.501
2007 Ko L, Salluzzi M, Frayne R, Smith M. Reexamining the quantification of perfusion MRI data in the presence of bolus dispersion. Journal of Magnetic Resonance Imaging : Jmri. 25: 639-43. PMID 17326085 DOI: 10.1002/Jmri.20781  0.505
2006 Salluzzi M, Frayne R, Smith MR. Is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies? Physics in Medicine and Biology. 51: 407-24. PMID 16394347 DOI: 10.1088/0031-9155/51/2/015  0.55
2005 Salluzzi M, Frayne R, Smith MR. An alternative viewpoint of the similarities and differences of SVD and FT deconvolution algorithms used for quantitative MR perfusion studies. Magnetic Resonance Imaging. 23: 481-92. PMID 15862650 DOI: 10.1016/J.Mri.2004.12.001  0.513
2004 Salluzzi M, Smith MR, Frayne R. Applying the transient error reconstruction algorithm in the assessment of the cerebral blood flow. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2: 1092-5. PMID 17271873 DOI: 10.1109/IEMBS.2004.1403354  0.527
Show low-probability matches.