cached image

David Ress - Publications

Affiliations: 
Brown University, Providence, RI 
Area:
Visual cortex
Website:
http://neuroscience.brown.edu/ress.html

74 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2019 Kim JH, Taylor AJ, Wang DJ, Zou X, Ress D. Dynamics of the cerebral blood flow response to brief neural activity in human visual cortex. Journal of Cerebral Blood Flow and Metabolism : Official Journal of the International Society of Cerebral Blood Flow and Metabolism. 271678X19869034. PMID 31429358 DOI: 10.1177/0271678X19869034  0.64
2019 Taylor AJ, Kim JH, Singh V, Halfen EJ, Pfeuffer J, Ress D. More than BOLD: Dual-spin populations create functional contrast. Magnetic Resonance in Medicine. PMID 31423634 DOI: 10.1002/mrm.27941  0.64
2018 Taylor AJ, Kim JH, Ress D. Characterization of the hemodynamic response function across the majority of human cerebral cortex. Neuroimage. PMID 29501554 DOI: 10.1016/j.neuroimage.2018.02.061  0.64
2017 Savjani RR, Katyal S, Halfen E, Kim JH, Ress D. Polar-angle representation of saccadic eye movements in human superior colliculus. Neuroimage. PMID 29292132 DOI: 10.1016/j.neuroimage.2017.12.080  1
2017 Kim JH, Ress D. Reliability of the depth-dependent high-resolution BOLD hemodynamic response in human visual cortex and vicinity. Magnetic Resonance Imaging. PMID 28137626 DOI: 10.1016/j.mri.2017.01.019  0.64
2016 Lal TM, Baldwin PR, Cai MB, Savjani RR, Eagleman DM, Ress D, Salas R. Real time functional MRI training to decrease motion in imaging studies: Lack of significant improvement. Bulletin of the Menninger Clinic. 80: 348-356. PMID 27936900 DOI: 10.1521/bumc.2016.80.4.348  0.64
2015 Kim JH, Ress D. Arterial impulse model for the BOLD response to brief neural activation. Neuroimage. PMID 26363350 DOI: 10.1016/j.neuroimage.2015.08.068  1
2015 Floren A, Naylor B, Miikkulainen R, Ress D. Accurately decoding visual information from fMRI data obtained in a realistic virtual environment Frontiers in Human Neuroscience. 9. DOI: 10.3389/fnhum.2015.00327  1
2015 Erwin A, O'Malley MK, Ress D, Sergi F. Development, control, and MRI-compatibility of the MR-SoftWrist Ieee International Conference On Rehabilitation Robotics. 2015: 187-192. DOI: 10.1109/ICORR.2015.7281197  1
2015 Singh V, Tewfik AH, Ress DB. Under-sampled functional MRI using low-rank plus sparse matrix decomposition Icassp, Ieee International Conference On Acoustics, Speech and Signal Processing - Proceedings. 2015: 897-901. DOI: 10.1109/ICASSP.2015.7178099  1
2014 Greene CA, Dumoulin SO, Harvey BM, Ress D. Measurement of population receptive fields in human early visual cortex using back-projection tomography. Journal of Vision. 14. PMID 24453343 DOI: 10.1167/14.1.17  1
2014 Katyal S, Ress D. Endogenous attention signals evoked by threshold contrast detection in human superior colliculus. The Journal of Neuroscience : the Official Journal of the Society For Neuroscience. 34: 892-900. PMID 24431447 DOI: 10.1523/JNEUROSCI.3026-13.2014  1
2013 Ress D, Chandrasekaran B. Tonotopic organization in the depth of human inferior colliculus. Frontiers in Human Neuroscience. 7: 586. PMID 24065909 DOI: 10.3389/fnhum.2013.00586  1
2013 Kim JH, Khan R, Thompson JK, Ress D. Model of the transient neurovascular response based on prompt arterial dilation. Journal of Cerebral Blood Flow and Metabolism : Official Journal of the International Society of Cerebral Blood Flow and Metabolism. 33: 1429-39. PMID 23756690 DOI: 10.1038/jcbfm.2013.90  1
2012 Kim JH, Khan RK, Ress D. Computational modeling of the transient hemodynamic response in cerebral cortex. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2012: 645-8. PMID 23365975 DOI: 10.1109/EMBC.2012.6346014  1
2012 Gopinath A, Xu G, Ress D, Öktem O, Subramaniam S, Bajaj C. Shape-based regularization of electron tomographic reconstruction. Ieee Transactions On Medical Imaging. 31: 2241-52. PMID 22922711 DOI: 10.1109/TMI.2012.2214229  1
2012 Katyal S, Greene CA, Ress D. High-resolution functional magnetic resonance imaging methods for human midbrain. Journal of Visualized Experiments : Jove. e3746. PMID 22617680 DOI: 10.3791/3746  1
2011 Khan R, Zhang Q, Darayan S, Dhandapani S, Katyal S, Greene C, Bajaj C, Ress D. Surface-based analysis methods for high-resolution functional magnetic resonance imaging. Graphical Models. 73: 313-322. PMID 22125419 DOI: 10.1016/j.gmod.2010.11.002  1
2010 Katyal S, Zughni S, Greene C, Ress D. Topography of covert visual attention in human superior colliculus. Journal of Neurophysiology. 104: 3074-83. PMID 20861435 DOI: 10.1152/jn.00283.2010  1
2010 Ress D, Dhandapani S, Katyal S, Greene C, Bajaj C. Surface-based imaging methods for high-resolution functional magnetic resonance imaging Lecture Notes in Computer Science (Including Subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics). 6026: 130-140. DOI: 10.1007/978-3-642-12712-0_12  1
2009 Ress D, Thompson JK, Rokers B, Khan RK, Huk AC. A model for transient oxygen delivery in cerebral cortex. Frontiers in Neuroenergetics. 1: 3. PMID 19597566 DOI: 10.3389/neuro.14.003.2009  1
2009 Nagwaney S, Harlow ML, Jung JH, Szule JA, Ress D, Xu J, Marshall RM, McMahan UJ. Macromolecular connections of active zone material to docked synaptic vesicles and presynaptic membrane at neuromuscular junctions of mouse. The Journal of Comparative Neurology. 513: 457-68. PMID 19226520 DOI: 10.1002/cne.21975  1
2008 Heitsch AT, Smith DK, Patel RE, Ress D, Korgel BA. Multifunctional Particles: Magnetic Nanocrystals and Gold Nanorods Coated with Fluorescent Dye-Doped Silica Shells. Journal of Solid State Chemistry. 181: 1590-1599. PMID 19578476 DOI: 10.1016/j.jssc.2008.05.002  1
2007 Ress D, Glover GH, Liu J, Wandell B. Laminar profiles of functional activity in the human brain. Neuroimage. 34: 74-84. PMID 17011213 DOI: 10.1016/j.neuroimage.2006.08.020  1
2007 Silver MA, Ress D, Heeger DJ. Neural correlates of sustained spatial attention in human early visual cortex. Journal of Neurophysiology. 97: 229-37. PMID 16971677 DOI: 10.1152/jn.00677.2006  1
2006 Grill-Spector K, Sayres R, Ress D. High-resolution imaging reveals highly selective nonface clusters in the fusiform face area. Nature Neuroscience. 9: 1177-85. PMID 16892057 DOI: 10.1038/nn1745  1
2005 Silver MA, Ress D, Heeger DJ. Topographic maps of visual spatial attention in human parietal cortex. Journal of Neurophysiology. 94: 1358-71. PMID 15817643 DOI: 10.1152/jn.01316.2004  1
2005 Ress D, Heeger DJ. Nonsensory signals in early visual cortex Neurobiology of Attention. 311-316. DOI: 10.1016/B978-012375731-9/50055-0  1
2005 Sayres R, Ress D, Grill-Spector K. Identifying distributed object representations in human extrastriate visual cortex Advances in Neural Information Processing Systems. 1169-1176.  1
2004 Miller KL, Hargreaves BA, Lee J, Ress D, deCharms RC, Pauly JM. Functional brain imaging with BOSS FMRI. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 7: 5234-7. PMID 17271520 DOI: 10.1109/IEMBS.2004.1404463  1
2004 Ress DB, Harlow ML, Marshall RM, McMahan UJ. Methods for generating high-resolution structural models from electron microscope tomography data. Structure (London, England : 1993). 12: 1763-74. PMID 15458626 DOI: 10.1016/j.str.2004.07.022  1
2003 Miller KL, Hargreaves BA, Lee J, Ress D, deCharms RC, Pauly JM. Functional brain imaging using a blood oxygenation sensitive steady state. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 50: 675-83. PMID 14523951 DOI: 10.1002/mrm.10602  1
2003 Ress D, Heeger DJ. Neuronal correlates of perception in early visual cortex. Nature Neuroscience. 6: 414-20. PMID 12627164 DOI: 10.1038/nn1024  1
2003 Silver MA, Ress D, Heeger DJ. Sustained attention-related activity in primary visual cortex Journal of Vision. 3: 179a. DOI: 10.1167/3.9.179  1
2003 Ress D, Harlow ML, Marshall RM, McMahan UJ. Optimization Method for Isodensity Surface Models Obtained with Electron Microscope Tomography Data Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 1: 774-777.  1
2002 Heeger DJ, Ress D. What does fMRI tell us about neuronal activity? Nature Reviews. Neuroscience. 3: 142-51. PMID 11836522 DOI: 10.1038/nrn730  1
2002 Ress D, Heeger DJ. Cortical activity corresponding to threshold visual pattern perception Journal of Vision. 2: 427a. DOI: 10.1167/2.7.427  1
2001 Huk AC, Ress D, Heeger DJ. Neuronal basis of the motion aftereffect reconsidered. Neuron. 32: 161-72. PMID 11604147 DOI: 10.1016/S0896-6273(01)00452-4  1
2001 Harlow ML, Ress D, Stoschek A, Marshall RM, McMahan UJ. The architecture of active zone material at the frog's neuromuscular junction. Nature. 409: 479-84. PMID 11206537 DOI: 10.1038/35054000  1
2001 Ress D, Heeger DJ. fMRI measurements of orientation-selective adaptation Journal of Vision. 1: 435a. DOI: 10.1167/1.3.435  1
2000 Ress D, Backus BT, Heeger DJ. Activity in primary visual cortex predicts performance in a visual detection task. Nature Neuroscience. 3: 940-5. PMID 10966626 DOI: 10.1038/78856  1
2000 Glover GH, Li TQ, Ress D. Image-based method for retrospective correction of physiological motion effects in fMRI: RETROICOR. Magnetic Resonance in Medicine. 44: 162-7. PMID 10893535 DOI: 10.1002/1522-2594(200007)44:1<162::AID-MRM23>3.0.CO;2-E  1
1999 Ress D, Harlow ML, Schwarz M, Marshall RM, McMahan UJ. Automatic acquisition of fiducial markers and alignment of images in tilt series for electron tomography. Journal of Electron Microscopy. 48: 277-87. PMID 10425746  1
1999 Lerche RA, Ress D, Ellis RJ, Lane SM. Neutron penumbral aperture images of inertial confinement fusion targets achieve 60 μm resolution (abstract) Review of Scientific Instruments. 70: 1220.  1
1998 Harlow M, Ress D, Koster A, Marshall RM, Schwarz M, McMahan UJ. Dissection of active zones at the neuromuscular junction by EM tomography. Journal of Physiology, Paris. 92: 75-8. PMID 9782447 DOI: 10.1016/S0928-4257(98)80141-1  1
1998 Cable MD, Barbee TW, Koch JA, Lane SM, Lerche RA, Moran MJ, Ognibene TE, Ress DB, Sangster TC, Trebes JE, Phillips TW, Hicks D, Li CK, Petrasso RD, Seguin F. Diagnostics for High-Density Implosions at Nova and the National Ignition Facility Plasma Physics Reports. 24: 110-113.  1
1997 Ze F, Langer SH, Kauffman RL, Kilkenny JD, Landen O, Ress D, Rosen MD, Suter LJ, Wallace RJ, Wiedwald JD. A comparative study of x-ray emission from laser spots in laser-heated hohlraums relative to spots on simple disk targets Physics of Plasmas. 4: 778-787.  1
1997 Leeper RJ, Chandler GA, Cooper GW, Derzon MS, Fehl DL, Hebron DE, Moats AR, Noack DD, Porter JL, Ruggles LE, Ruiz CL, Torres JA, Cable MD, Bell PM, Clower CA, ... ... Ress D, et al. Target diagnostic system for the national ignition facility (invited) Review of Scientific Instruments. 68: 868-879.  1
1996 Da Silva LB, Cauble R, Barbee TW, Celliers P, Ciarlo D, Libby S, London RA, Matthews D, Mrowka S, Moreno JC, Ress D, Trebes JE, Wan AS, Weber F. Two-dimensional interferogram of an exploding selenium foil using a soft x-ray laser interferometer Ieee Transactions On Plasma Science. 24: 31-32. DOI: 10.1109/27.491676  1
1995 Da Silva LB, Barbee TW, Cauble R, Celliers P, Ciarlo D, Libby S, London RA, Matthews D, Mrowka S, Moreno JC, Ress D, Trebes JE, Wan AS, Weber F. Electron Density Measurements of High Density Plasmas Using Soft X-Ray Laser Interferometry. Physical Review Letters. 74: 3991-3994. PMID 10058385 DOI: 10.1103/PhysRevLett.74.3991  1
1995 Hauer AA, Suter L, Delamater N, Ress D, Powers L, Magelssen G, Harris D, Landen O, Lindmann E, Hsing W, Wilson D, Amendt P, Thiessen R, Kopp R, Phillion D, et al. Role of symmetry in indirect-drive laser fusion Physics of Plasmas. 2: 2488-2494. DOI: 10.1063/1.871210  1
1995 Ress D, DaSilva LB, London RA, Trebes JE, Lerche RA, Bradley DK. Novel x-ray imaging methods at the Nova laser facility (invited) Review of Scientific Instruments. 66: 579-584. DOI: 10.1063/1.1146290  1
1995 Da Silva LB, Barbee TW, Cauble R, Celliers P, Harder J, Lee HR, London RA, Matthews DL, Mrowka S, Moreno JC, Ress D, Trebes JE, Wan A, Weber F. X-ray lasers for high density plasma diagnostics (invited) Review of Scientific Instruments. 66: 574-578. DOI: 10.1063/1.1146289  1
1995 Hauer A, Delamater N, Ress D, Hsing W, Suter L, Powers L, Landen O, Harris D, Thiessen R, Magelssen G, Lindman E, Phillion D, Amendt P, Watt R, Hammel B. Review of drive symmetry measurement and control experiments on the Nova laser system Review of Scientific Instruments. 66: 672-677. DOI: 10.1063/1.1146257  1
1995 Ress D, Lerche RA, Ellis RJ, Heaton GW, Lehr DE. High-sensitivity scintillating-fiber imaging detector for high-energy neutrons Review of Scientific Instruments. 66: 4943-4948. DOI: 10.1063/1.1146179  1
1995 Celliers P, Barbee TW, Cauble R, Da Silva LB, Moreno JC, Ress D, Trebes JE, Wan AS, Weber F. Applications of soft x-ray lasers for plasma diagnostics Conference Proceedings - Lasers and Electro-Optics Society Annual Meeting-Leos. 1: 323-324.  1
1995 Cauble R, Da Silva LB, Barbee TW, Celliers P, Libby S, Moreno JC, Ress D, Trebes J, Wan AS, Weber F. High density plasma diagnostics utilizing a neon-like yttrium x-ray laser Journal of Quantitative Spectroscopy and Radiative Transfer. 54: 97-103.  1
1994 Ress D, Dasilva LB, London RA, Trebes JE, Mrowka S, Procassini RJ, Barbee TW, Lehr DE. Measurement of Laser-Plasma Electron Density with a Soft X-ray Laser Deflectometer. Science (New York, N.Y.). 265: 514-7. PMID 17781311 DOI: 10.1126/science.265.5171.514  1
1994 Suter LJ, Hauer AA, Powers LV, Ress DB, Delameter N, Hsing WW, Landen OL, Thiessen AR, Turner RE. Modeling and interpretation of Nova's symmetry scaling data base. Physical Review Letters. 73: 2328-2331. PMID 10057032 DOI: 10.1103/PhysRevLett.73.2328  1
1994 Cable MD, Hatchett SP, Caird JA, Kilkenny JD, Kornblum HN, Lane SM, Laumann C, Lerche RA, Murphy TJ, Murray J, Nelson MB, Phillion DW, Powell H, Ress DB. Indirectly driven, high convergence inertial confinement fusion implosions. Physical Review Letters. 73: 2316-2319. PMID 10057029 DOI: 10.1103/PhysRevLett.73.2316  1
1994 Libby SB, Da Silva LB, Barbee TW, Cauble R, Celliers P, Lee HR, London RA, Matthews DL, Mrowka S, Moreno JC, Ress D, Trebes JE, Wan A, Weber F, Van Wonterghem B. X-ray laser as a tool for imaging plasmas Ieee Leos Annual Meeting - Proceedings. 1: 291-292.  1
1994 Ress DB, Lerche RA, Ellis RJ, Heaton GW, Nelson MB, Mant G, Lehr DE. Scintillating fiber imaging detector for 14-MeV neutrons Proceedings of Spie - the International Society For Optical Engineering. 2281: 95-112.  1
1993 Ress D, Bell PM, Bradley DK. A time-resolved x-ray ring coded-aperture microscope for inertial confinement fusion applications Review of Scientific Instruments. 64: 1404-1406. DOI: 10.1063/1.1144051  1
1992 Ress D, Ciarlo DR, Stewart JE, Bell PM, Kania DR. A ring coded-aperture microscope for high-resolution imaging of high-energy x rays Review of Scientific Instruments. 63: 5086-5088. DOI: 10.1063/1.1143500  1
1992 Ress D, Lerche RA, Da Silva L. Demonstration of an x-ray ring-aperture microscope for inertial-confinement fusion experiments Applied Physics Letters. 60: 410-412. DOI: 10.1063/1.106673  1
1991 Lerche RA, Ress D, Ellis RJ, Lane SM, Nugent KA. Neutron penumbral imaging of laser-fusion targets Laser and Particle Beams. 9: 99-118. DOI: 10.1017/S0263034600002366  1
1990 Ress D. Design of thick apertures for high-resolution neutron penumbral imaging Ieee Transactions On Nuclear Science. 37: 155-160. DOI: 10.1109/23.106610  1
1990 Ress D, Rice BW, Horton RD. X-ray diagnostic for measurement of hot-electron power loss Review of Scientific Instruments. 61: 2777-2779. DOI: 10.1063/1.1141828  1
1990 Ress D, Lerche RA, Ellis RJ, Lane SM. Design of a neutron penumbral-aperture microscope with 10 μm resolution Review of Scientific Instruments. 61: 3184-3186. DOI: 10.1063/1.1141680  1
1990 Gabl EF, Failor BH, Busch GE, Schroeder RJ, Ress D, Suter L. Plasma evolution from laser-driven gold disks. I. Experiments and results Physics of Fluids B. 2: 2437-2447.  1
1990 Ress D, Suter LJ, Gabl EF, Failor BH. Plasma evolution from laser-driven gold disks. II. Computational design and analysis Physics of Fluids B. 2: 2448-2455.  1
1989 Gabl EF, Failor BH, Armentrout CJ, Delamater ND, Fechner WB, Bosch RA, Busch GE, Koenig ZM, Ress D, Suter L, Schroeder RJ. Plasma jets from laser-irradiated planar targets. Physical Review Letters. 63: 2737-2740. PMID 10040977 DOI: 10.1103/PhysRevLett.63.2737  1
1988 Ress D, Lerche RA, Ellis RJ, Lane SM, Nugent KA. Neutron imaging of laser fusion targets. Science (New York, N.Y.). 241: 956-8. PMID 17731445 DOI: 10.1126/science.241.4868.956  1
1988 Ress D, Lerche RA, Ellis RJ, Lane SM, Nugent KA. Neutron imaging of inertial confinement fusion targets at Nova Review of Scientific Instruments. 59: 1694-1696. DOI: 10.1063/1.1140136  1
Show low-probability matches.