Year |
Citation |
Score |
2024 |
Esplen N, Egoriti L, Planche T, Rädel S, Koay HW, Humphries B, Ren X, Ford N, Hoehr C, Gottberg A, Bazalova-Carter M. Dosimetric characterization of a novel UHDR megavoltage X-ray source for FLASH radiobiological experiments. Scientific Reports. 14: 822. PMID 38191885 DOI: 10.1038/s41598-023-50412-w |
0.362 |
|
2023 |
O'Connell J, Weil MD, Bazalova-Carter M. Non-coplanar lung SABR treatments delivered with a gantry-mounted x-ray tube. Physics in Medicine and Biology. PMID 38035372 DOI: 10.1088/1361-6560/ad111a |
0.343 |
|
2023 |
Clements N, Esplen N, Bazalova-Carter M. A feasibility study of ultra-high dose rate mini-GRID therapy using very-high-energy electron beams for a simulated pediatric brain case. Physica Medica : Pm : An International Journal Devoted to the Applications of Physics to Medicine and Biology : Official Journal of the Italian Association of Biomedical Physics (Aifb). 112: 102637. PMID 37454482 DOI: 10.1016/j.ejmp.2023.102637 |
0.305 |
|
2022 |
Clements N, Bazalova-Carter M, Esplen N. Monte Carlo optimization of a GRID collimator for preclinical megavoltage ultra-high dose rate spatially-fractionated radiation therapy. Physics in Medicine and Biology. 67. PMID 35998651 DOI: 10.1088/1361-6560/ac8c1a |
0.304 |
|
2022 |
Hart AJ, Cecchi D, Giguère C, Larose F, Therriault-Proulx F, Esplen NM, Beaulieu L, Bazalova-Carter M. Lead-doped scintillator dosimeters for detection of ultrahigh dose-rate x-rays. Physics in Medicine and Biology. PMID 35453128 DOI: 10.1088/1361-6560/ac69a5 |
0.342 |
|
2022 |
Esplen NM, Egoriti L, Paley W, Planche T, Hoehr C, Gottberg A, Bazalova-Carter M. Design optimization of an electron-to-photon conversion target for ultra-high dose rate x-ray (FLASH) experiments at TRIUMF. Physics in Medicine and Biology. PMID 35299167 DOI: 10.1088/1361-6560/ac5ed6 |
0.341 |
|
2022 |
O'Connell J, Bazalova-Carter M. Investigation of image quality of MV and kV CBCT with low-Z beams and high DQE detector. Medical Physics. 49: 2334-2341. PMID 35098549 DOI: 10.1002/mp.15503 |
0.319 |
|
2021 |
Cecchi DD, Therriault-Proulx F, Lambert-Girard S, Hart A, Macdonald A, Pfleger M, Lenckowski M, Bazalova-Carter M. Characterization of an x-ray tube-based ultrahigh dose-rate system for in vitro irradiations. Medical Physics. PMID 34528283 DOI: 10.1002/mp.15234 |
0.35 |
|
2021 |
Stalbaum T, Partain L, Weil MD, Kim J, Han JY, Plies MJ, Chen H, Ziskin V, Bazalova-Carter M, Song S, Rand R, Boyd D. Dosimetry of a novel converging x-ray source for kilovoltage radiotherapy. Medical Physics. PMID 34390498 DOI: 10.1002/mp.15167 |
0.335 |
|
2021 |
O'Connell J, Bazalova-Carter M. fastCAT: Fast cone beam CT (CBCT) simulation. Medical Physics. PMID 34053094 DOI: 10.1002/mp.15007 |
0.311 |
|
2020 |
Breitkreutz DY, Weil MD, Bazalova-Carter M. External beam radiation therapy with kilovoltage x-rays. Physica Medica : Pm : An International Journal Devoted to the Applications of Physics to Medicine and Biology : Official Journal of the Italian Association of Biomedical Physics (Aifb). 79: 103-112. PMID 33221545 DOI: 10.1016/j.ejmp.2020.11.001 |
0.759 |
|
2020 |
Curry CB, Dunning CAS, Gauthier M, Chou HJ, Fiuza F, Glenn GD, Tsui YY, Bazalova-Carter M, Glenzer SH. Optimization of radiochromic film stacks to diagnose high-flux laser-accelerated proton beams. The Review of Scientific Instruments. 91: 093303. PMID 33003776 DOI: 10.1063/5.0020568 |
0.571 |
|
2020 |
Esplen N, Mendonca MS, Bazalova-Carter M. Physics and biology of ultrahigh dose-rate (FLASH) radiotherapy: a topical review. Physics in Medicine and Biology. 65: 23TR03. PMID 32721941 DOI: 10.1088/1361-6560/Abaa28 |
0.396 |
|
2020 |
Dunning CAS, O'Connell J, Robinson SM, Murphy KJ, Frencken AL, van Veggel FCJM, Iniewski K, Bazalova-Carter M. Photon-counting computed tomography of lanthanide contrast agents with a high-flux 330-m-pitch cadmium zinc telluride detector in a table-top system. Journal of Medical Imaging (Bellingham, Wash.). 7: 033502. PMID 32566695 DOI: 10.1117/1.Jmi.7.3.033502 |
0.664 |
|
2020 |
Poirier Y, Johnstone CD, Anvari A, Brodin NP, Dos Santos M, Bazalova-Carter M, Sawant A. A Failure Modes and Effects Analysis Quality Management Framework for Image-Guided Small Animal Irradiators : A Change in Paradigm for Radiation Biology. Medical Physics. PMID 31986221 DOI: 10.1002/mp.14049 |
0.695 |
|
2020 |
Byrne K, Alharbi M, Esplen N, Woulfe P, O'Keeffe S, Bazalova-Carter M, Foley M. Initial Evaluation of the Performance of Novel Inorganic Scintillating Detectors for Small Animal Irradiation Dosimetry Ieee Sensors Journal. 20: 4704-4712. DOI: 10.1109/Jsen.2020.2964989 |
0.399 |
|
2020 |
Richtsmeier D, Dunning C, Iniewski K, Bazalova-Carter M. Multi-contrast K-edge imaging on a bench-top photon-counting CT system: acquisition parameter study Journal of Instrumentation. 15: P10029-P10029. DOI: 10.1088/1748-0221/15/10/p10029 |
0.58 |
|
2020 |
Dunning C, Bazalova-Carter M. Design of a combined X-ray fluorescence Computed Tomography (CT) and photon-counting CT table-top imaging system Journal of Instrumentation. 15: P06031-P06031. DOI: 10.1088/1748-0221/15/06/p06031 |
0.608 |
|
2019 |
Breitkreutz DY, Renaud MA, Weil MD, Zavgorodni S, Han J, Baxter H, Seuntjens J, Song S, Boyd D, Bazalova-Carter M. Monte Carlo calculated kilovoltage x-ray arc therapy plans for three lung cancer patients. Biomedical Physics & Engineering Express. 5. PMID 34170854 DOI: 10.1088/2057-1976/ab4dc5 |
0.74 |
|
2019 |
Bazalova-Carter M, Esplen N. On the capabilities of conventional x-ray tubes to deliver ultra-high (FLASH) dose rates. Medical Physics. 46: 5690-5695. PMID 31600830 DOI: 10.1002/mp.13858 |
0.345 |
|
2019 |
Dunning CAS, Bazalova-Carter M. X-Ray Fluorescence Computed Tomography Induced by Photon, Electron, and Proton Beams. Ieee Transactions On Medical Imaging. 38: 2735-2743. PMID 31021762 DOI: 10.1109/Tmi.2019.2912137 |
0.692 |
|
2019 |
Breitkreutz DY, Bialek S, Vojnovic B, Kavanagh A, Johnstone CD, Rovner Z, Tsouchlos P, Kanesalingam T, Bazalova-Carter M. A 3D-printed modular phantom for quality assurance of image-guided small animal irradiators: design, imaging experiments and Monte Carlo simulations. Medical Physics. PMID 30947359 DOI: 10.1002/mp.13525 |
0.737 |
|
2019 |
Johnstone CD, Therriault-Proulx F, Beaulieu L, Bazalova-Carter M. Characterization of a plastic scintillating detector for the Small Animal Radiation Research Platform (SARRP). Medical Physics. 46: 394-404. PMID 30417377 DOI: 10.1002/mp.13283 |
0.751 |
|
2019 |
Breitkreutz DY, Renaud M, Weil MD, Zavgorodni S, Han J, Baxter H, Seuntjens J, Song S, Boyd D, Bazalova-Carter M. Monte Carlo calculated kilovoltage x-ray arc therapy plans for three lung cancer patients Biomedical Physics & Engineering Express. 5: 65022. DOI: 10.1088/2057-1976/Ab4Dc5 |
0.749 |
|
2019 |
O'Connell J, Iniewski K, Bazalova-Carter M. Optimal planar X-ray imaging soft tissue segmentation using a photon counting detector Journal of Instrumentation. 14: P01020-P01020. DOI: 10.1088/1748-0221/14/01/P01020 |
0.33 |
|
2018 |
Dunning CAS, Bazalova-Carter M. Optimization of a table-top x-ray fluorescence computed tomography (XFCT) system. Physics in Medicine and Biology. 63: 235013. PMID 30474621 DOI: 10.1088/1361-6560/aaece9 |
0.633 |
|
2018 |
Lindsay C, Bazalova-Carter M, Wang A, Shedlock D, Wu M, Newson M, Xing L, Ansbacher W, Fahrig R, Star-Lack J. Investigation of combined kV/MV CBCT imaging with a high-DQE MV detector. Medical Physics. PMID 30428131 DOI: 10.1002/Mp.13291 |
0.327 |
|
2018 |
Breitkreutz DY, Renaud MA, Seuntjens J, Weil MD, Zavgorodni S, Bazalova-Carter M. Inverse optimization of low-cost kilovoltage x-ray arc therapy plans. Medical Physics. PMID 30152125 DOI: 10.1002/Mp.13153 |
0.733 |
|
2018 |
Esplen NM, Chergui L, Johnstone CD, Bazalova-Carter M. Monte Carlo optimization of a microbeam collimator design for use on the small animal radiation research platform (SARRP). Physics in Medicine and Biology. 63: 175004. PMID 30074490 DOI: 10.1088/1361-6560/Aad7E2 |
0.73 |
|
2018 |
Johnstone CD, Bazalova-Carter M. MicroCT imaging dose to mouse organs using a validated Monte Carlo model of the small animal radiation research platform (SARRP). Physics in Medicine and Biology. 63: 115012. PMID 29741161 DOI: 10.1088/1361-6560/Aac335 |
0.746 |
|
2018 |
Dunning CAS, Bazalova-Carter M. Sheet beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticles. Medical Physics. 45: 2572-2582. PMID 29604070 DOI: 10.1002/Mp.12893 |
0.68 |
|
2017 |
Breitkreutz DY, Weil MD, Zavgorodni S, Bazalova-Carter M. Monte Carlo simulations of a kilovoltage external beam radiotherapy system on phantoms and breast patients. Medical Physics. 44: 6548-6559. PMID 28986987 DOI: 10.1002/Mp.12619 |
0.754 |
|
2017 |
Johnstone CD, Lindsay P, Graves E, Wong E, Perez J, Poirier Y, Ben-Bouchta Y, Kanesalingam T, Chen H, Rubinstein A, Sheng K, Bazalova-Carter M. Multi-institutional MicroCT image comparison of image-guided small animal irradiators. Physics in Medicine and Biology. PMID 28574405 DOI: 10.1088/1361-6560/Aa76B4 |
0.723 |
|
2017 |
Giacometti V, Guatelli S, Bazalova-Carter M, Rosenfeld AB, Schulte RW. Development of a high resolution voxelised head phantom for medical physics applications. Physica Medica : Pm : An International Journal Devoted to the Applications of Physics to Medicine and Biology : Official Journal of the Italian Association of Biomedical Physics (Aifb). PMID 28108101 DOI: 10.1016/J.Ejmp.2017.01.007 |
0.384 |
|
2016 |
Bazalova-Carter M, Weil MD, Breitkreutz DY, Wilfley BP, Graves EE. Feasibility of external beam radiation therapy to deep-seated targets with kilovoltage x-rays. Medical Physics. PMID 28133751 DOI: 10.1002/Mp.12047 |
0.772 |
|
2016 |
Bazalova-Carter M, Wang A, Wu M, Newson M, Xing L, Ansbacher W, Fahrig R, Star-Lack J. SU-D-BRA-07: Applications of Combined KV/MV CBCT Imaging with a High-DQE MV Detector. Medical Physics. 43: 3340-3341. PMID 28046211 DOI: 10.1118/1.4955640 |
0.346 |
|
2016 |
Lloyd SA, Gagne IM, Bazalova-Carter M, Zavgorodni S. Measured and Monte Carlo simulated electron backscatter to the monitor chamber for the Varian TrueBeam Linac. Physics in Medicine and Biology. 61: 8779-8793. PMID 27897141 DOI: 10.1088/1361-6560/61/24/8779 |
0.338 |
|
2016 |
Lloyd SA, Gagne IM, Bazalova-Carter M, Zavgorodni S. Validation of Varian TrueBeam electron phase-spaces for Monte Carlo simulation of MLC-shaped fields. Medical Physics. 43: 2894. PMID 27277038 DOI: 10.1118/1.4949000 |
0.336 |
|
2016 |
Palma B, Bazalova-Carter M, Hårdemark B, Hynning E, Qu B, Loo BW, Maxim PG. Assessment of the quality of very high-energy electron radiotherapy planning. Radiotherapy and Oncology : Journal of the European Society For Therapeutic Radiology and Oncology. 119: 154-8. PMID 26898508 DOI: 10.1016/J.Radonc.2016.01.017 |
0.371 |
|
2016 |
Whelan B, Bazalova-Carter M, Oborn B, Constantin D, Holloway L, Fahrig R, Keall P. TU-H-BRA-03: Performance of a Clinical Gridded Electron Gun in Magnetic Fields: Implications for MRI-Linac Therapy Medical Physics. 43: 3769-3769. DOI: 10.1118/1.4957625 |
0.346 |
|
2015 |
Bazalova-Carter M, Ahmad M, Xing L, Fahrig R. Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study. Journal of Medical Imaging (Bellingham, Wash.). 2: 043501. PMID 26839910 DOI: 10.1117/1.Jmi.2.4.043501 |
0.467 |
|
2015 |
Shuhendler AJ, Ye D, Brewer KD, Bazalova-Carter M, Lee KH, Kempen P, Dane Wittrup K, Graves EE, Rutt B, Rao J. Molecular Magnetic Resonance Imaging of Tumor Response to Therapy. Scientific Reports. 5: 14759. PMID 26440059 DOI: 10.1038/Srep14759 |
0.374 |
|
2015 |
Bazalova-Carter M, Schlosser J, Chen J, Hristov D. Monte Carlo modeling of ultrasound probes for image guided radiotherapy. Medical Physics. 42: 5745. PMID 26429248 DOI: 10.1118/1.4929978 |
0.472 |
|
2015 |
Bazalova-Carter M. The potential of L-shell X-ray fluorescence CT (XFCT) for molecular imaging. The British Journal of Radiology. 88: 20140308. PMID 26204972 DOI: 10.1259/Bjr.20140308 |
0.458 |
|
2015 |
Bazalova-Carter M, Ahmad M, Matsuura T, Takao S, Matsuo Y, Fahrig R, Shirato H, Umegaki K, Xing L. TH-AB-204-11: X-Ray Fluorescence CT Induced by Proton Beam: Experiments and Simulations. Medical Physics. 42: 3716. PMID 26129479 DOI: 10.1118/1.4926178 |
0.526 |
|
2015 |
Bazalova-Carter M, Ahmad M, Xing L, Fahrig R. TH-AB-204-09: High-Sensitivity L-Shell X-Ray Fluorescence CT Imaging of Gold. Medical Physics. 42: 3715. PMID 26129475 DOI: 10.1118/1.4926176 |
0.439 |
|
2015 |
Bazalova-Carter M, Qu B, Palma B, Hårdemark B, Hynning E, Jensen C, Maxim PG, Loo BW. Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans. Medical Physics. 42: 2615. PMID 25979053 DOI: 10.1118/1.4918923 |
0.418 |
|
2015 |
Bazalova-Carter M, Liu M, Palma B, Dunning M, McCormick D, Hemsing E, Nelson J, Jobe K, Colby E, Koong AC, Tantawi S, Dolgashev V, Maxim PG, Loo BW. Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom. Medical Physics. 42: 1606-13. PMID 25832051 DOI: 10.1118/1.4914371 |
0.405 |
|
2015 |
Bazalova-Carter M, Ahmad M, Matsuura T, Takao S, Matsuo Y, Fahrig R, Shirato H, Umegaki K, Xing L. Proton-induced x-ray fluorescence CT imaging. Medical Physics. 42: 900-7. PMID 25652502 DOI: 10.1118/1.4906169 |
0.477 |
|
2015 |
Ahmad M, Bazalova-Carter M, Fahrig R, Xing L. Optimized Detector Angular Configuration Increases the Sensitivity of X-ray Fluorescence Computed Tomography (XFCT). Ieee Transactions On Medical Imaging. 34: 1140-7. PMID 25474808 DOI: 10.1109/Tmi.2014.2376813 |
0.48 |
|
2015 |
Palma B, Bazalova-Carter M, Hardemark B, Hynning E, Qu B, Loo B, Maxim P. MO-FG-303-06: Evaluation of the Performance of Very High-Energy Electron (VHEE) Beams in Radiotherapy: Five Clinical Cases Medical Physics. 42: 3568-3568. DOI: 10.1118/1.4925419 |
0.412 |
|
2015 |
Bazalova-Carter M, Ahmad M, Matsuura T, Takao S, Matsuo Y, Fahrig R, Shirato H, Umegaki K, Xing L. PD-0140: Proton induced x-ray fluorescence CT (pXFCT) imaging: a step towards proton beam range detection Radiotherapy and Oncology. 115: S66-S67. DOI: 10.1016/S0167-8140(15)40138-0 |
0.43 |
|
Show low-probability matches. |