Robert W. Mann - Publications

Affiliations: 
Biomedical Engineering Massachusetts Institute of Technology, Cambridge, MA, United States 
Area:
biomedical prosthetic devices
Website:
http://news.mit.edu/2006/obit-mann

35 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2005 Morrell KC, Hodge WA, Krebs DE, Mann RW. Corroboration of in vivo cartilage pressures with implications for synovial joint tribology and osteoarthritis causation Proceedings of the National Academy of Sciences of the United States of America. 102: 14819-14824. PMID 16203974 DOI: 10.1073/Pnas.0507117102  0.332
2002 Mann RW. Comment on normal hip joint contact pressure distribution in single-leg standing-effect of gender and an atomic parameters Journal of Biomechanics. 35: 1291-1292. PMID 12214587 DOI: 10.1016/S0021-9290(02)00076-3  0.327
2002 Mann RW. Comments on the influence of the acetabular labrum on hip joint cartilage consolidation: a poroelastic finite element model. Journal of Biomechanics. 35: 147-9. PMID 11747894 DOI: 10.1016/S0021-9290(01)00136-1  0.316
1999 Park S, Krebs DE, Mann RW. Hip muscle co-contraction: Evidence from concurrent in vivo pressure measurement and force estimation Gait and Posture. 10: 211-222. PMID 10567753 DOI: 10.1016/S0966-6362(99)00033-8  0.349
1999 McGibbon CA, Krebs DE, Trahan CA, Trippel SB, Mann RW. Cartilage degeneration in relation to repetitive pressure: Case study of a unilateral hip hemiarthroplasty patient Journal of Arthroplasty. 14: 52-58. PMID 9926953 DOI: 10.1016/S0883-5403(99)90202-4  0.319
1998 Krebs DE, Robbins CE, Lavine L, Mann RW. Hip biomechanics during gait Journal of Orthopaedic and Sports Physical Therapy. 28: 51-59. PMID 9653690 DOI: 10.2519/Jospt.1998.28.1.51  0.372
1997 McGibbon CA, Krebs DE, Mann RW. In vivo hip pressures during cane and load-carrying gait Arthritis Care and Research. 10: 300-307. PMID 9362596 DOI: 10.1002/Art.1790100504  0.329
1996 McGibbon C, Krebs D, Mann R. Pressures exerted on acetabular cartilage in-vivo while using a cane and carrying loads in one hand Gait & Posture. 4: 188-189. DOI: 10.1016/0966-6362(96)80619-9  0.328
1995 Fagerson TL, Krebs DE, Harris BA, Mann RW. Examining Shibboleths of Hip Rehabilitation Protocols Using in vivo Contact Pressures from an Instrumented Hemiarthroplasty Physiotherapy. 81: 533-540. DOI: 10.1016/S0031-9406(05)66690-4  0.307
1994 Macirowski T, Tepic S, Mann RW. Cartilage stresses in the human hip joint. Journal of Biomechanical Engineering. 116: 10-8. PMID 8189704 DOI: 10.1115/1.2895693  0.325
1994 Krebs D, Riley P, Carlson K, Mann R. Direct evidence of acetabular joint preloading during locomotion Journal of Biomechanics. 27: 805. DOI: 10.1016/0021-9290(94)91345-5  0.334
1992 Givens-Heiss DL, Krebs DE, Riley PO, Strickland EM, Fares M, Hodge WA, Mann RW. In vivo acetabular contact pressures during rehabilitation, Part II: Postacute phase. Physical Therapy. 72: 700-5; discussion 70. PMID 1528963 DOI: 10.1093/Ptj/72.10.700  0.341
1991 Krebs DE, Elbaum L, Riley PO, Hodge WA, Mann RW. Exercise and gait effects on in vivo hip contact pressures. Physical Therapy. 71: 301-9. PMID 2008453 DOI: 10.1093/Ptj/71.4.301  0.315
1990 Riley PO, Mann RW, Hodge WA. Modelling of the biomechanics of posture and balance. Journal of Biomechanics. 23: 503-6. PMID 2373723 DOI: 10.1016/0021-9290(90)90306-N  0.309
1990 Harris C, Krebs D, Riley P, Carlson K, Hodge W, Mann R. The effects of running and gaining weight in comparison with normal gait on pressures measured in the human hip joint Journal of Biomechanics. 23: 732. DOI: 10.1016/0021-9290(90)90249-3  0.356
1989 Modest VE, Murphy MC, Mann RW. Optical verification of a technique for in situ ultrasonic measurement of articular cartilage thickness. Journal of Biomechanics. 22: 171-6. PMID 2651447 DOI: 10.1016/0021-9290(89)90041-9  0.301
1986 Hodge WA, Fijan RS, Carlson KL, Burgess RG, Harris WH, Mann RW. Contact pressures in the human hip joint measured in vivo. Proceedings of the National Academy of Sciences of the United States of America. 83: 2879-83. PMID 3458248 DOI: 10.1073/Pnas.83.9.2879  0.395
1985 Tepic S, Macirowski T, Mann RW. Experimental temperature rise in human hip joint in vitro in simulated walking. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 3: 516-20. PMID 4067710 DOI: 10.1002/Jor.1100030416  0.355
1985 Tepic S, Macirowski T, Mann RW. Computer Simulation of Interarticular Fluid Flow Journal of Biomechanics. 18: 221-226. DOI: 10.1007/978-94-011-7432-9_28  0.322
1983 Tepic S, Macirowski T, Mann RW. Mechanical properties of articular cartilage elucidated by osmotic loading and ultrasound. Proceedings of the National Academy of Sciences of the United States of America. 80: 3331-3. PMID 6574487 DOI: 10.1073/Pnas.80.11.3331  0.326
1981 Patriarco AG, Mann RW, Simon SR, Mansour JM. An evaluation of the approaches of optimization models in the prediction of muscle forces during human gait. Journal of Biomechanics. 14: 513-25. PMID 7276011 DOI: 10.1016/0021-9290(81)90001-4  0.309
1981 Rushfeldt PD, Mann RW, Harris WH. Improved techniques for measuring in vitro the geometry and pressure distribution in the human acetabulum. II Instrumented endoprosthesis measurement of articular surface pressure distribution. Journal of Biomechanics. 14: 315-23. PMID 7263723 DOI: 10.1016/0021-9290(81)90041-5  0.325
1981 Rushfeldt PD, Mann RW, Harris WH. Improved techniques for measuring in vitro the geometry and pressure distribution in the human acetabulum--I. Ultrasonic measurement of acetabular surfaces, sphericity and cartilage thickness. Journal of Biomechanics. 14: 253-60. PMID 7240287 DOI: 10.1016/0021-9290(81)90070-1  0.338
1981 Tepic S, Mann R, Harris W. Analytical macrogeometry representation and congruency of the human hip joint Journal of Biomechanics. 14: 490. DOI: 10.1016/0021-9290(81)90118-4  0.334
1981 Mann R, Rushfeldt P, Harris W. Quantitative synovial joint geometry and load distribution Journal of Biomechanics. 14: 489. DOI: 10.1016/0021-9290(81)90117-2  0.312
1981 Macirowski T, Mann R, Harris W. Local variations in the pressures in the human hip joint Journal of Biomechanics. 14: 489. DOI: 10.1016/0021-9290(81)90116-0  0.34
1981 Mann RW. Cybernetic limb prosthesis: The ALZA distinguished lecture Annals of Biomedical Engineering. 9: 1-43. DOI: 10.1007/Bf02584556  0.318
1980 Hogan N, Mann RW. Myoelectric signal processing: optimal estimation applied to electromyography--Part II: experimental demonstration of optimal myoprocessor performance. Ieee Transactions On Bio-Medical Engineering. 27: 396-410. PMID 7409805 DOI: 10.1109/Tbme.1980.326653  0.454
1980 Hogan N, Mann RW. Myoelectric signal processing: optimal estimation applied to electromyography--Part I: derivation of the optimal myoprocessor. Ieee Transactions On Bio-Medical Engineering. 27: 382-95. PMID 7409804 DOI: 10.1109/Tbme.1980.326652  0.45
1980 Hardt DE, Mann RW. A five body--three dimensional dynamic analysis of walking. Journal of Biomechanics. 13: 455-7. PMID 7400173 DOI: 10.1016/0021-9290(80)90040-8  0.551
1977 Flowers WC, Mann RW. An electrohydraulic knee-torque controller for a prosthesis simulator. Journal of Biomechanical Engineering. 99: 3-8. PMID 23720163 DOI: 10.1115/1.3426266  0.665
1974 Carlson CE, Mann RW, Harris WH. A radio telemetry device for monitoring cartilage surface pressures in the human hip. Ieee Transactions On Bio-Medical Engineering. 21: 257-64. PMID 4837472 DOI: 10.1109/Tbme.1974.324311  0.327
1974 Carlson CE, Mann RW, Harris WH. A look at the prosthesis-cartilage interface: design of a hip prosthesis containing pressure transducers. Journal of Biomedical Materials Research. 8: 261-9. PMID 4411650 DOI: 10.1002/Jbm.820080405  0.375
1970 Mann R, Reimers S. Kinesthetic Sensing for the EMG Controlled "Boston Arm" Ieee Transactions On Man Machine Systems. 11: 110-115. DOI: 10.1109/Tmms.1970.299971  0.331
1968 Mann RW. Design Criteria, Development and Pre-And Post-Fitting Amputee Evaluation of an EMG Controlled, Force Sensing, Proportional-Rate, Elbow Prosthesis with Cutaneous Kinesthetic Feedback Ifac Proceedings Volumes. 2: 579-586. DOI: 10.1016/S1474-6670(17)68904-3  0.347
Show low-probability matches.