Sandilya V. Garimella, Ph.D. - Publications

Affiliations: 
2012 Biomedical Engineering Purdue University, West Lafayette, IN, United States 
Area:
mass spectrometric instrumentation, including miniature mass spectrometers.

28 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2022 Giberson C, Singh RK, Chun J, Huntley AP, Zhong J, Ibrahim YM, Schenter GK, Lee JY, Garimella SV. SimELIT: A Novel GUI-Based Comprehensive Ion Trajectory Simulation Software for Mass Spectrometry. Journal of the American Society For Mass Spectrometry. 33: 1453-1457. PMID 35852821 DOI: 10.1021/jasms.1c00301  0.509
2017 Tummalacherla M, Garimella SV, Prost SA, Ibrahim YM. Toward artifact-free data in Hadamard transform-based double multiplexing of ion mobility-Orbitrap mass spectrometry. The Analyst. PMID 28406514 DOI: 10.1039/C7An00289K  0.329
2017 Deng L, Webb IK, Garimella SV, Hamid AM, Zheng X, Norheim RV, Prost SA, Anderson GA, Sandoval JA, Baker ES, Ibrahim YM, Smith RD. Serpentine Ultra-long Path with Extended Routing (SUPER) High Resolution Traveling Wave Ion Mobility-MS using Structures for Lossless Ion Manipulations. Analytical Chemistry. PMID 28332832 DOI: 10.1021/Acs.Analchem.7B00185  0.463
2017 Ibrahim YM, Hamid AM, Deng L, Garimella SV, Webb IK, Baker ES, Smith RD. New frontiers for mass spectrometry based upon structures for lossless ion manipulations. The Analyst. PMID 28262893 DOI: 10.1039/C7An00031F  0.526
2017 Ibrahim YM, Hamid AM, Cox JT, Garimella SV, Smith RD. Ion Elevators and Escalators in Multilevel Structures for Lossless Ion Manipulations. Analytical Chemistry. 89: 1972-1977. PMID 28208272 DOI: 10.1021/Acs.Analchem.6B04500  0.501
2017 Wojcik R, Webb IK, Deng L, Garimella SV, Prost SA, Ibrahim YM, Baker ES, Smith RD. Lipid and Glycolipid Isomer Analyses Using Ultra-High Resolution Ion Mobility Spectrometry Separations. International Journal of Molecular Sciences. 18. PMID 28106768 DOI: 10.3390/Ijms18010183  0.308
2016 Ibrahim YM, Garimella SV, Prost SA, Wojcik R, Norheim RV, Baker ES, Rusyn I, Smith RD. Development of an Ion Mobility Spectrometry-Orbitrap Mass Spectrometer Platform. Analytical Chemistry. 88: 12152-12160. PMID 28193022 DOI: 10.1021/Acs.Analchem.6B03027  0.325
2016 Garimella SV, Hamid AM, Deng L, Ibrahim YM, Webb IK, Baker ES, Prost SA, Norheim RV, Anderson GA, Smith RD. Squeezing of Ion Populations and Peaks in Traveling Wave Ion Mobility Separations and Structures for Lossless Ion Manipulations Using Compression Ratio Ion Mobility Programming. Analytical Chemistry. 88: 11877-11885. PMID 27934097 DOI: 10.1021/Acs.Analchem.6B03660  0.477
2016 Deng L, Ibrahim YM, Garimella SV, Webb IK, Hamid AM, Norheim RV, Prost SA, Sandoval JA, Baker ES, Smith RD. Greatly Increasing Trapped Ion Populations for Mobility Separations Using Traveling Waves in Structures for Lossless Ion Manipulations. Analytical Chemistry. PMID 27715008 DOI: 10.1021/Acs.Analchem.6B02678  0.509
2016 Deng L, Ibrahim YM, Hamid AM, Garimella SV, Webb IK, Zheng X, Prost SA, Sandoval JA, Norheim RV, Anderson GA, Tolmachev AV, Baker ES, Smith RD. Ultra-High Resolution Ion Mobility Separations Utilizing Traveling Waves in a 13-m Serpentine Path Length Structures for Lossless Ion Manipulations Module. Analytical Chemistry. PMID 27531027 DOI: 10.1021/Acs.Analchem.6B01915  0.377
2016 Hamid AM, Garimella SV, Ibrahim YM, Deng L, Zheng X, Webb IK, Anderson GA, Prost SA, Norheim RV, Tolmachev AV, Baker ES, Smith RD. Achieving high resolution ion mobility separations using traveling waves in compact multi-turn Structures for Lossless Ion Manipulations. Analytical Chemistry. PMID 27479234 DOI: 10.1021/Acs.Analchem.6B01914  0.483
2016 Webb IK, Garimella SV, Norheim RV, Baker ES, Ibrahim YM, Smith RD. A Structures for Lossless Ion Manipulations (SLIM) Module for Collision Induced Dissociation. Journal of the American Society For Mass Spectrometry. PMID 27098413 DOI: 10.1007/S13361-016-1397-X  0.427
2016 Garimella SV, Ibrahim YM, Tang K, Webb IK, Baker ES, Tolmachev AV, Chen TC, Anderson GA, Smith RD. Spatial Ion Peak Compression and its Utility in Ion Mobility Spectrometry. Journal of the American Society For Mass Spectrometry. PMID 27052738 DOI: 10.1007/S13361-016-1371-7  0.593
2016 Chen TC, Ibrahim YM, Webb IK, Garimella SV, Zhang X, Hamid AM, Deng L, Karnesky WE, Prost SA, Sandoval JA, Norheim RV, Anderson GA, Tolmachev AV, Baker ES, Smith RD. Mobility-Selected Ion Trapping and Enrichment Using Structures for Lossless Ion Manipulations. Analytical Chemistry. PMID 26752262 DOI: 10.1021/Acs.Analchem.5B03910  0.637
2015 Hamid AM, Ibrahim YM, Garimella SV, Webb IK, Deng L, Chen TC, Anderson GA, Prost SA, Norheim RV, Tolmachev AV, Smith RD. Characterization of Traveling Wave Ion Mobility Separations in Structures for Lossless Ion Manipulations. Analytical Chemistry. PMID 26510005 DOI: 10.1021/Acs.Analchem.5B02481  0.635
2015 Garimella SV, Ibrahim YM, Webb IK, Ipsen AB, Chen TC, Tolmachev AV, Baker ES, Anderson GA, Smith RD. Ion manipulations in structures for lossless ion manipulations (SLIM): computational evaluation of a 90° turn and a switch. The Analyst. 140: 6845-52. PMID 26289106 DOI: 10.1039/C5An00844A  0.623
2015 Zhang X, Garimella SV, Prost SA, Webb IK, Chen TC, Tang K, Tolmachev AV, Norheim RV, Baker ES, Anderson GA, Ibrahim YM, Smith RD. Ion Trapping, Storage, and Ejection in Structures for Lossless Ion Manipulations. Analytical Chemistry. 87: 6010-6. PMID 25971536 DOI: 10.1021/Acs.Analchem.5B00214  0.613
2014 Garimella SV, Ibrahim YM, Webb IK, Tolmachev AV, Zhang X, Prost SA, Anderson GA, Smith RD. Simulation of electric potentials and ion motion in planar electrode structures for lossless ion manipulations (SLIM). Journal of the American Society For Mass Spectrometry. 25: 1890-6. PMID 25257188 DOI: 10.1007/S13361-014-0976-Y  0.512
2014 Webb IK, Garimella SV, Tolmachev AV, Chen TC, Zhang X, Cox JT, Norheim RV, Prost SA, LaMarche B, Anderson GA, Ibrahim YM, Smith RD. Mobility-resolved ion selection in uniform drift field ion mobility spectrometry/mass spectrometry: dynamic switching in structures for lossless ion manipulations. Analytical Chemistry. 86: 9632-7. PMID 25222548 DOI: 10.1021/Ac502139E  0.626
2014 Tolmachev AV, Webb IK, Ibrahim YM, Garimella SV, Zhang X, Anderson GA, Smith RD. Characterization of ion dynamics in structures for lossless ion manipulations. Analytical Chemistry. 86: 9162-8. PMID 25152178 DOI: 10.1021/Ac502054P  0.49
2014 Webb IK, Garimella SV, Tolmachev AV, Chen TC, Zhang X, Norheim RV, Prost SA, LaMarche B, Anderson GA, Ibrahim YM, Smith RD. Experimental evaluation and optimization of structures for lossless ion manipulations for ion mobility spectrometry with time-of-flight mass spectrometry. Analytical Chemistry. 86: 9169-76. PMID 25152066 DOI: 10.1021/Ac502055E  0.612
2014 Ibrahim YM, Garimella SV, Tolmachev AV, Baker ES, Smith RD. Improving ion mobility measurement sensitivity by utilizing helium in an ion funnel trap. Analytical Chemistry. 86: 5295-9. PMID 24786390 DOI: 10.1021/Ac404250Z  0.511
2014 Lin Z, Tan L, Garimella S, Li L, Chen TC, Xu W, Xia Y, Ouyang Z. Characterization of a DAPI-RIT-DAPI system for gas-phase ion/molecule and ion/ion reactions. Journal of the American Society For Mass Spectrometry. 25: 48-56. PMID 24150848 DOI: 10.1007/S13361-013-0757-Z  0.68
2013 Chen CH, Lin Z, Garimella S, Zheng L, Shi R, Cooks RG, Ouyang Z. Development of a mass spectrometry sampling probe for chemical analysis in surgical and endoscopic procedures. Analytical Chemistry. 85: 11843-50. PMID 24251679 DOI: 10.1021/Ac4025279  0.561
2013 Garimella S, Zhou X, Ouyang Z. Simulation of rarefied gas flows in atmospheric pressure interfaces for mass spectrometry systems. Journal of the American Society For Mass Spectrometry. 24: 1890-9. PMID 24043523 DOI: 10.1007/S13361-013-0736-4  0.501
2012 Chen TC, Xu W, Garimella S, Ouyang Z. Study of the efficiency for ion transfer through bent capillaries. Journal of Mass Spectrometry : Jms. 47: 1466-72. PMID 23147823 DOI: 10.1002/Jms.3117  0.684
2012 Garimella S, Xu W, Huang G, Harper JD, Cooks RG, Ouyang Z. Gas-flow assisted ion transfer for mass spectrometry. Journal of Mass Spectrometry : Jms. 47: 201-7. PMID 22359330 DOI: 10.1002/Jms.2955  0.666
2009 Go DB, Fisher TS, Garimella SV. Direct simulation of ionization and ion transport for planar microscale ion generation devices Journal of Physics D: Applied Physics. 42. DOI: 10.1088/0022-3727/42/5/055203  0.415
Show low-probability matches.