Masoud Agah, Ph.D. - Publications

Affiliations: 
2005 University of Michigan, Ann Arbor, Ann Arbor, MI 

82 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2023 Thamatam N, Ahn J, Chowdhury M, Sharma A, Gupta P, Marr LC, Nazhandali L, Agah M. A MEMS-enabled portable gas chromatography injection system for trace analysis. Analytica Chimica Acta. 1261: 341209. PMID 37147055 DOI: 10.1016/j.aca.2023.341209  0.347
2021 Gholizadeh A, Chowdhury M, Agah M. Ionic liquid stationary phase coating optimization for semi-packed microfabricated columns. Journal of Chromatography. A. 1647: 462144. PMID 33957352 DOI: 10.1016/j.chroma.2021.462144  0.301
2020 Gholizadeh A, Chowdhury M, Agah M. Parallel Ionic Liquid Semi-Packed Microfabricated Columns for Complex Gas Analysis. Analytical Chemistry. PMID 32640785 DOI: 10.1021/Acs.Analchem.0C01721  0.469
2020 Kikkeri K, Kerr BA, Bertke AS, Strobl JS, Agah M. Passivated-Electrode Insulator-based Dielectrophoretic Separation of Heterogeneous Cell Mixtures. Journal of Separation Science. PMID 31991043 DOI: 10.1002/Jssc.201900553  0.342
2019 Ghassemi P, Ren X, Foster BM, Kerr BA, Agah M. Post-enrichment circulating tumor cell detection and enumeration via deformability impedance cytometry. Biosensors & Bioelectronics. 111868. PMID 31767345 DOI: 10.1016/J.Bios.2019.111868  0.311
2019 Nam W, Ren X, Tali SAS, Ghassemi P, Kim I, Agah M, Zhou W. RI-Insensitive Nanolaminated SERS Substrates for Label-free Raman Profiling and Classification of Living Cancer Cells. Nano Letters. PMID 31525057 DOI: 10.1021/Acs.Nanolett.9B02864  0.308
2019 Ren X, Ghassemi P, Strobl JS, Agah M. Biophysical phenotyping of cells via impedance spectroscopy in parallel cyclic deformability channels. Biomicrofluidics. 13: 044103. PMID 31341524 DOI: 10.1063/1.5099269  0.301
2019 Chan R, Agah M. Semi-Packed Gas Chromatography Columns With Density Modulated Pillars Journal of Microelectromechanical Systems. 28: 114-124. DOI: 10.1109/Jmems.2018.2881532  0.459
2018 Regmi BP, Agah M. Micro Gas Chromatography: An Overview of Critical Components and Their Integration. Analytical Chemistry. PMID 30359512 DOI: 10.1021/Acs.Analchem.8B01461  0.44
2018 Regmi BP, Chan R, Atta A, Agah M. Ionic liquid-coated alumina-pretreated micro gas chromatography columns for high-efficient separations. Journal of Chromatography. A. 1566: 124-134. PMID 30017088 DOI: 10.1016/J.Chroma.2018.06.058  0.451
2018 Ren X, Foster B, Ghassemi P, Strobl JS, Kerr BA, Agah M. Entrapment of Prostate Cancer Circulating Tumor Cells with a Sequential Size-Based Microfluidic Chip. Analytical Chemistry. PMID 29790741 DOI: 10.1021/Acs.Analchem.8B01134  0.329
2018 Kikkeri K, Riquelme Breazeal MV, Ren X, Pruden A, Agah M. A Monolithic Dielectrophoresis Chip With Impedimetric Sensing for Assessment of Pathogen Viability Journal of Microelectromechanical Systems. 27: 810-817. DOI: 10.1109/Jmems.2018.2860926  0.338
2017 Ren X, Ghassemi P, Babahosseini H, Strobl JS, Agah M. Single-Cell Mechanical Characteristics Analyzed by Multiconstriction Microfluidic Channels. Acs Sensors. 2: 290-299. PMID 28723132 DOI: 10.1021/Acssensors.6B00823  0.312
2017 Regmi BP, Chan R, Agah M. Ionic liquid functionalization of semi-packed columns for high-performance gas chromatographic separations. Journal of Chromatography. A. PMID 28662852 DOI: 10.1016/J.Chroma.2017.06.050  0.5
2017 Hosseini Y, Soltanian-Zadeh S, Srinivasaraghavan V, Agah M. A Silicon-Based Porous Thin Membrane as a Cancer Cell Transmigration Assay Journal of Microelectromechanical Systems. 26: 308-316. DOI: 10.1109/Jmems.2016.2618774  0.359
2017 Shakeel H, Agah M. High density semipacked separation columns with optimized atomic layer deposited phases Sensors and Actuators B: Chemical. 242: 215-223. DOI: 10.1016/J.Snb.2016.11.046  0.421
2015 Srinivasaraghavan V, Strobl J, Agah M. Microelectrode bioimpedance analysis distinguishes basal and claudin-low subtypes of triple negative breast cancer cells. Biomedical Microdevices. 17: 80. PMID 26216474 DOI: 10.1007/S10544-015-9977-2  0.302
2015 Nakidde D, Zellner P, Alemi MM, Shake T, Hosseini Y, Riquelme MV, Pruden A, Agah M. Three dimensional passivated-electrode insulator-based dielectrophoresis. Biomicrofluidics. 9: 014125. PMID 25784964 DOI: 10.1063/1.4913497  0.328
2015 Akbar M, Shakeel H, Agah M. GC-on-chip: integrated column and photoionization detector. Lab On a Chip. 15: 1748-58. PMID 25673367 DOI: 10.1039/C4Lc01461H  0.485
2015 Zellner P, Shake T, Hosseini Y, Nakidde D, Riquelme MV, Sahari A, Pruden A, Behkam B, Agah M. 3D Insulator-based dielectrophoresis using DC-biased, AC electric fields for selective bacterial trapping. Electrophoresis. 36: 277-83. PMID 25257669 DOI: 10.1002/Elps.201400236  0.315
2015 Akbar M, Shakeel H, Agah M. An integrated chromatographychip for rapid gas separation and detection Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 2015: 771-774. DOI: 10.1109/MEMSYS.2015.7051072  0.384
2015 Akbar M, Restaino M, Agah M. Chip-scale gas chromatography: From injection through detection Microsystems & Nanoengineering. 1. DOI: 10.1038/Micronano.2015.39  0.785
2015 Shakeel H, Wang D, Heflin JR, Agah M. Improved self-assembled thiol stationary phases in microfluidic gas separation columns Sensors and Actuators, B: Chemical. 216: 349-357. DOI: 10.1016/J.Snb.2015.03.107  0.406
2015 Garg A, Akbar M, Vejerano E, Narayanan S, Nazhandali L, Marr LC, Agah M. Zebra GC: A mini gas chromatography system for trace-level determination of hazardous air pollutants Sensors and Actuators, B: Chemical. 212: 145-154. DOI: 10.1016/J.Snb.2014.12.136  0.452
2015 Narayanan S, Rice G, Agah M. Characterization of a micro-helium discharge detector for gas chromatography Sensors and Actuators, B: Chemical. 206: 190-197. DOI: 10.1016/J.Snb.2014.09.014  0.363
2014 Akbar M, Narayanan S, Restaino M, Agah M. A purge and trap integrated microGC platform for chemical identification in aqueous samples. The Analyst. 139: 3384-92. PMID 24837988 DOI: 10.1039/C4An00254G  0.775
2014 Shakeel H, Wang D, Heflin JR, Agah M. Width-modulated microfluidic columns for gas separations Ieee Sensors Journal. 14: 3352-3357. DOI: 10.1109/Jsen.2014.2326593  0.379
2014 Garg A, Akbar M, Narayanan S, Nazhandali L, Agah M. Zebra GC: A fully integrated micro gas chromatography system Proceedings of Ieee Sensors. 2014: 673-676. DOI: 10.1109/ICSENS.2014.6985088  0.362
2014 Shakeel H, Rice GW, Agah M. Semipacked columns with atomic layer-deposited alumina as a stationary phase Sensors and Actuators, B: Chemical. 203: 641-646. DOI: 10.1016/J.Snb.2014.06.017  0.393
2014 Narayanan S, Rice G, Agah M. A micro-discharge photoionization detector for micro-gas chromatography Microchimica Acta. 181: 493-499. DOI: 10.1007/S00604-013-1146-9  0.447
2013 Akbar M, Wang D, Goodman R, Hoover A, Rice G, Heflin JR, Agah M. Improved performance of micro-fabricated preconcentrators using silica nanoparticles as a surface template. Journal of Chromatography. A. 1322: 1-7. PMID 24268363 DOI: 10.1016/J.Chroma.2013.10.083  0.368
2013 Shake T, Zellner P, Sahari A, Breazeal MV, Behkam B, Pruden A, Agah M. Embedded passivated-electrode insulator-based dielectrophoresis (EπDEP). Analytical and Bioanalytical Chemistry. 405: 9825-33. PMID 24162823 DOI: 10.1007/S00216-013-7435-7  0.329
2013 Wang D, Shakeel H, Lovette J, Rice GW, Heflin JR, Agah M. Highly stable surface functionalization of microgas chromatography columns using layer-by-layer self-assembly of silica nanoparticles. Analytical Chemistry. 85: 8135-41. PMID 23889461 DOI: 10.1021/Ac401080U  0.371
2013 Zellner P, Shake T, Sahari A, Behkam B, Agah M. Off-chip passivated-electrode, insulator-based dielectrophoresis (OπDEP). Analytical and Bioanalytical Chemistry. 405: 6657-66. PMID 23812879 DOI: 10.1007/S00216-013-7123-7  0.309
2013 Alfeeli B, Narayanan S, Moodie D, Zellner P, McMillan M, Hirtenstein D, Rice G, Agah M. Interchannel mixing minimization in semi-packed micro gas chromatography columns Ieee Sensors Journal. 13: 4312-4319. DOI: 10.1109/Jsen.2013.2267795  0.77
2013 Nikkhah M, Strobl JS, Srinivasaraghavan V, Agah M. Isotropically etched silicon microarrays for rapid breast cancer cell capture Ieee Sensors Journal. 13: 1125-1132. DOI: 10.1109/Jsen.2012.2227716  0.333
2013 Narayanan S, Agah M. Fabrication and characterization of a suspended TCD integrated with a gas separation column Journal of Microelectromechanical Systems. 22: 1166-1173. DOI: 10.1109/Jmems.2013.2255117  0.488
2013 Hosseini Y, Zellner P, Agah M. A single-mask process for 3-D microstructure fabrication in PDMS Journal of Microelectromechanical Systems. 22: 356-362. DOI: 10.1109/Jmems.2012.2231402  0.346
2013 Akbar M, Agah M. A microfabricated propofol trap for breath-based anesthesia depth monitoring Journal of Microelectromechanical Systems. 22: 443-451. DOI: 10.1109/Jmems.2012.2227949  0.437
2013 Shakeel H, Agah M. Self-patterned gold-electroplated multicapillary gas separation columns with MPG stationary phases Journal of Microelectromechanical Systems. 22: 62-70. DOI: 10.1109/Jmems.2012.2213068  0.423
2013 Shakeel H, Wang D, Heflin R, Agah M. Width-modulated microgas chromatography separation columns with silica nanoparticles stationary phase Ieee Sensors 2013 - Proceedings. DOI: 10.1109/ICSENS.2013.6688124  0.31
2012 Zellner P, Agah M. Silicon insulator-based dielectrophoresis devices for minimized heating effects. Electrophoresis. 33: 2498-507. PMID 22899257 DOI: 10.1002/Elps.201100661  0.367
2012 Akbar M, Agah M. A golden micro-trap for anesthetic depth monitoring using human breath samples Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 906-909. DOI: 10.1109/MEMSYS.2012.6170332  0.339
2012 Shakeel H, Rice G, Agah M. First reconfigurable MEMS separation columns for micro gas chromatography Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 823-826. DOI: 10.1109/MEMSYS.2012.6170312  0.368
2012 Narayanan S, Alfeeli B, Agah M. Two-port static coated micro gas chromatography column with an embedded thermal conductivity detector Ieee Sensors Journal. 12: 1893-1900. DOI: 10.1109/Jsen.2011.2180017  0.797
2012 Narayanan S, Agah M. A high-performance TCD monolithically integrated with a gas separation column Proceedings of Ieee Sensors. DOI: 10.1109/ICSENS.2012.6411575  0.402
2012 Shakeel H, Agah M. Semipacked separation columns with monolayer protected gold stationary phases for microgas chromatography Proceedings of Ieee Sensors. DOI: 10.1109/ICSENS.2012.6411352  0.337
2012 Akbar M, Agah M. A cascaded micro preconcentration approach for extraction of volatile organic compounds in water Proceedings of Ieee Sensors. DOI: 10.1109/ICSENS.2012.6411337  0.338
2012 Narayanan S, Agah M. A micro gas chromatography column with an embedded out-of-plane thermal conductivity detector Technical Digest - Solid-State Sensors, Actuators, and Microsystems Workshop. 221-224.  0.392
2011 Vereb H, Dietrich AM, Alfeeli B, Agah M. The possibilities will take your breath away: breath analysis for assessing environmental exposure. Environmental Science & Technology. 45: 8167-75. PMID 21838235 DOI: 10.1021/Es202041J  0.725
2011 Nikkhah M, Strobl JS, Schmelz EM, Roberts PC, Zhou H, Agah M. MCF10A and MDA-MB-231 human breast basal epithelial cell co-culture in silicon micro-arrays. Biomaterials. 32: 7625-32. PMID 21764441 DOI: 10.1016/J.Biomaterials.2011.06.041  0.304
2011 Alfeeli B, Agah M. Toward handheld diagnostics of cancer biomarkers in breath: Micro preconcentration of trace levels of volatiles in human breath Ieee Sensors Journal. 11: 2756-2762. DOI: 10.1109/Jsen.2011.2160390  0.762
2011 Shakeel H, Agah M. High-performance multicapillary gas separation columns with MPG stationary phases Proceedings of Ieee Sensors. 1909-1912. DOI: 10.1109/ICSENS.2011.6127406  0.367
2011 Alfeeli B, Narayanan S, McMillan M, Hirtenstein D, Rice G, Agah M. The effect of pillar array in semi-packed micro gas chromatography Proceedings of Ieee Sensors. 1097-1100. DOI: 10.1109/ICSENS.2011.6127373  0.351
2011 Alfeeli B, Jain V, Johnson RK, Beyer FL, Heflin JR, Agah M. Characterization of poly(2,6-diphenyl-p-phenylene oxide) films as adsorbent for microfabricated preconcentrators Microchemical Journal. 98: 240-245. DOI: 10.1016/J.Microc.2011.02.006  0.731
2010 Strobl JS, Nikkhah M, Agah M. Actions of the anti-cancer drug suberoylanilide hydroxamic acid (SAHA) on human breast cancer cytoarchitecture in silicon microstructures. Biomaterials. 31: 7043-50. PMID 20579727 DOI: 10.1016/J.Biomaterials.2010.05.023  0.305
2010 Zareian-Jahromi MA, Agah M. Microfabricated gas chromatography columns with monolayer-protected gold stationary phases Journal of Microelectromechanical Systems. 19: 294-304. DOI: 10.1109/JMEMS.2009.2038936  0.335
2010 Narayanan S, Alfeeli B, Agah M. Thermostatted micro gas chromatography column with on-chip thermal conductivity detector for elevated temperature separation Proceedings of Ieee Sensors. 2504-2507. DOI: 10.1109/ICSENS.2010.5690117  0.378
2010 Zellner P, Renaghan L, Hasnain Z, Agah M. A fabrication technology for three-dimensional micro total analysis systems Journal of Micromechanics and Microengineering. 20. DOI: 10.1088/0960-1317/20/4/045013  0.376
2010 Narayanan S, Nikkhah M, Strob JS, Agah M. Analysis of the passivation layer by testing and modeling a cell impedance micro-sensor Sensors and Actuators, a: Physical. 159: 241-247. DOI: 10.1016/J.Sna.2009.12.036  0.314
2010 Alfeeli B, Hogg D, Agah M. Solid-phase microextraction using silica fibers coated with tenax-TA films Procedia Engineering. 5: 1152-1155. DOI: 10.1016/J.Proeng.2010.09.315  0.717
2010 Narayanan S, Alfeeli B, Agah M. A micro gas chromatography chip with an embedded non-cascaded thermal conductivity detector Procedia Engineering. 5: 29-32. DOI: 10.1016/J.Proeng.2010.09.040  0.783
2010 Alfeeli B, Taylor LT, Agah M. Evaluation of Tenax TA thin films as adsorbent material for micro preconcentration applications Microchemical Journal. 95: 259-267. DOI: 10.1016/J.Microc.2009.12.011  0.75
2009 Alfeeli B, Zareian-Jahromi MA, Agah M. Selective micro preconcentration of propofol for anesthetic depth monitoring by using seedless electroplated gold as adsorbent. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2009: 2763-6. PMID 19964594 DOI: 10.1109/IEMBS.2009.5333868  0.759
2009 Alfeeli B, Agah M. MEMS-Based selective preconcentration of trace level breath analytes Ieee Sensors Journal. 9: 1068-1075. DOI: 10.1109/Jsen.2009.2025822  0.762
2009 Zareian-Jahromi MA, Ashraf-Khorassani M, Taylor LT, Agah M. Design, modeling, and fabrication of MEMS-based multicapillary gas chromatographic columns Journal of Microelectromechanical Systems. 18: 28-37. DOI: 10.1109/Jmems.2008.2007267  0.486
2009 Ali S, Ashraf-Khorassani M, Taylor LT, Agah M. MEMS-based semi-packed gas chromatography columns Sensors and Actuators, B: Chemical. 141: 309-315. DOI: 10.1016/J.Snb.2009.06.022  0.499
2008 Alfeeli B, Agah M. Micro preconcentrator with embedded 3D pillars for breath analysis applications Proceedings of Ieee Sensors. 736-739. DOI: 10.1109/ICSENS.2008.4716547  0.301
2008 Alfeeli B, Ali S, Jain V, Montazami R, Heflin J, Agah M. MEMS-based gas chromatography columns with nano-structured stationary phases Proceedings of Ieee Sensors. 728-731. DOI: 10.1109/ICSENS.2008.4716545  0.301
2008 Gantz K, Renaghan L, Agah M. Development of a comprehensive model for RIE-lag-based three-dimensional microchannel fabrication Journal of Micromechanics and Microengineering. 18. DOI: 10.1088/0960-1317/18/2/025003  0.344
2008 Alfeeli B, Cho D, Ashraf-Khorassani M, Taylor LT, Agah M. MEMS-based multi-inlet/outlet preconcentrator coated by inkjet printing of polymer adsorbents Sensors and Actuators, B: Chemical. 133: 24-32. DOI: 10.1016/J.Snb.2008.01.063  0.797
2007 Reidy S, George D, Agah M, Sacks R. Temperature-programmed GC using silicon microfabricated columns with integrated heaters and temperature sensors. Analytical Chemistry. 79: 2911-7. PMID 17311465 DOI: 10.1021/Ac062148S  0.402
2007 Agah M, Wise KD. Low-mass PECVD oxynitride gas chromatographic columns Journal of Microelectromechanical Systems. 16: 853-860. DOI: 10.1109/Jmems.2007.893515  0.658
2006 Agah M, Lambertus GR, Sacks R, Wise K. High-speed MEMS-based gas chromatography Journal of Microelectromechanical Systems. 15: 1371-1378. DOI: 10.1109/JMEMS.2006.879708  0.545
2005 Lu CJ, Steinecker WH, Tian WC, Oborny MC, Nichols JM, Agah M, Potkay JA, Chan HK, Driscoll J, Sacks RD, Wise KD, Pang SW, Zellers ET. First-generation hybrid MEMS gas chromatograph. Lab On a Chip. 5: 1123-31. PMID 16175269 DOI: 10.1039/B508596A  0.803
2005 Agah M, Wise KD. A fully-dry pecvd-oxynitride process for microgc column fabrication Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 774-777. DOI: 10.1109/MEMSYS.2005.1454044  0.513
2005 Agah M, Potkay JA, Lambertus G, Sacks R, Wise KD. High-performance temperature-programmed microfabricated gas chromatography columns Journal of Microelectromechanical Systems. 14: 1039-1050. DOI: 10.1109/Jmems.2005.856648  0.766
2005 Agah M, Wise KD. PECVD-oxynitride gas chromatographic columns Technical Digest - International Electron Devices Meeting, Iedm. 2005: 302-305.  0.561
2004 Lambertus G, Elstro A, Sensenig K, Potkay J, Agah M, Scheuering S, Wise K, Dorman F, Sacks R. Design, fabrication, and evaluation of microfabricated columns for gas chromatography. Analytical Chemistry. 76: 2629-37. PMID 15117208 DOI: 10.1021/Ac030367X  0.779
2004 Agah M, Lambertus GR, Sacks RD, Wise KD. High-speed MEMS-based gas chromatography Technical Digest - International Electron Devices Meeting, Iedm. 27-30. DOI: 10.1109/Jmems.2006.879708  0.644
2003 Agah M, Potkay JA, Driscoll JA, Sacks RD, Kaviany M, Wise KD. Thermal behavior of high-performance temperature programmed microfabricated gas chromatography columns Transducers 2003 - 12th International Conference On Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers. 2: 1339-1342. DOI: 10.1109/SENSOR.2003.1217021  0.746
2003 Potkay JA, Driscoll JA, Agah M, Sacks RD, Wise KD. A high-performance microfabricated gas chromatography column Proceedings of the Ieee Micro Electro Mechanical Systems (Mems). 395-398.  0.76
Show low-probability matches.