Year |
Citation |
Score |
2017 |
Niederauer S, de Gennaro J, Nygaard I, Petelenz T, Hitchcock R. Development of a novel intra-abdominal pressure transducer for large scale clinical studies. Biomedical Microdevices. 19: 80. PMID 28844111 DOI: 10.1007/S10544-017-0211-2 |
0.303 |
|
2016 |
Huang C, Sachse FB, Hitchcock RW, Kaza AK. Sensitivity and Specificity of Cardiac Tissue Discrimination Using Fiber-Optics Confocal Microscopy. Plos One. 11: e0147667. PMID 26808149 DOI: 10.1371/Journal.Pone.0147667 |
0.345 |
|
2015 |
Egger MJ, Hamad NM, Hitchcock RW, Coleman TJ, Shaw JM, Hsu Y, Nygaard IE. Reproducibility of intra-abdominal pressure measured during physical activities via a wireless vaginal transducer. Female Pelvic Medicine & Reconstructive Surgery. 21: 164-9. PMID 25730430 DOI: 10.1097/Spv.0000000000000167 |
0.665 |
|
2015 |
Coleman TJ, Nygaard IE, Holder DN, Egger MJ, Hitchcock R. Intra-abdominal pressure during Pilates: unlikely to cause pelvic floor harm. International Urogynecology Journal. 26: 1123-30. PMID 25672647 DOI: 10.1007/S00192-015-2638-4 |
0.653 |
|
2015 |
Coleman TJ, Hamad NM, Shaw JM, Egger MJ, Hsu Y, Hitchcock R, Jin H, Choi CK, Nygaard IE. Effects of walking speeds and carrying techniques on intra-abdominal pressure in women. International Urogynecology Journal. 26: 967-74. PMID 25527480 DOI: 10.1007/S00192-014-2593-5 |
0.654 |
|
2014 |
Huang C, Kaza AK, Hitchcock RW, Sachse FB. Local delivery of fluorescent dye for fiber-optics confocal microscopy of the living heart. Frontiers in Physiology. 5: 367. PMID 25309455 DOI: 10.3389/Fphys.2014.00367 |
0.302 |
|
2014 |
Shaw JM, Hamad NM, Coleman TJ, Egger MJ, Hsu Y, Hitchcock R, Nygaard IE. Intra-abdominal pressures during activity in women using an intra-vaginal pressure transducer. Journal of Sports Sciences. 32: 1176-85. PMID 24575741 DOI: 10.1080/02640414.2014.889845 |
0.665 |
|
2014 |
Emmert MY, Hitchcock RW, Hoerstrup SP. Cell therapy, 3D culture systems and tissue engineering for cardiac regeneration. Advanced Drug Delivery Reviews. 69: 254-69. PMID 24378579 DOI: 10.1016/J.Addr.2013.12.004 |
0.323 |
|
2013 |
Huang C, Kaza AK, Hitchcock RW, Sachse FB. Identification of nodal tissue in the living heart using rapid scanning fiber-optics confocal microscopy and extracellular fluorophores. Circulation. Cardiovascular Imaging. 6: 739-46. PMID 23811748 DOI: 10.1161/Circimaging.112.000121 |
0.33 |
|
2013 |
Hamad NM, Shaw JM, Nygaard IE, Coleman TJ, Hsu Y, Egger M, Hitchcock RW. More complicated than it looks: the vagaries of calculating intra-abdominal pressure. Journal of Strength and Conditioning Research / National Strength & Conditioning Association. 27: 3204-15. PMID 23439349 DOI: 10.1519/Jsc.0B013E31828B8E4C |
0.67 |
|
2012 |
Lasher RA, Pahnke AQ, Johnson JM, Sachse FB, Hitchcock RW. Electrical stimulation directs engineered cardiac tissue to an age-matched native phenotype. Journal of Tissue Engineering. 3: 2041731412455354. PMID 22919458 DOI: 10.1177/2041731412455354 |
0.777 |
|
2012 |
Hsu Y, Coleman TJ, Hitchcock RW, Heintz K, Shaw JM, Nygaard IE. Clinical evaluation of a wireless intra-vaginal pressure transducer. International Urogynecology Journal. 23: 1741-7. PMID 22618208 DOI: 10.1007/S00192-012-1811-2 |
0.676 |
|
2012 |
Coleman TJ, Thomsen JC, Maass SD, Hsu Y, Nygaard IE, Hitchcock RW. Development of a wireless intra-vaginal transducer for monitoring intra-abdominal pressure in women. Biomedical Microdevices. 14: 347-55. PMID 22147020 DOI: 10.1007/S10544-011-9611-X |
0.678 |
|
2011 |
Lackey DP, Carruth ED, Lasher RA, Boenisch J, Sachse FB, Hitchcock RW. Three-dimensional modeling and quantitative analysis of gap junction distributions in cardiac tissue. Annals of Biomedical Engineering. 39: 2683-94. PMID 21822740 DOI: 10.1007/S10439-011-0369-3 |
0.767 |
|
2011 |
Kennedy JP, McCandless SP, Rauf A, Williams LM, Hillam J, Hitchcock RW. Engineered channels enhance cellular density in perfused scaffolds. Acta Biomaterialia. 7: 3896-904. PMID 21745609 DOI: 10.1016/J.Actbio.2011.06.037 |
0.333 |
|
2011 |
Dittami GM, Rajguru SM, Lasher RA, Hitchcock RW, Rabbitt RD. Intracellular calcium transients evoked by pulsed infrared radiation in neonatal cardiomyocytes. The Journal of Physiology. 589: 1295-306. PMID 21242257 DOI: 10.1113/Jphysiol.2010.198804 |
0.738 |
|
2011 |
Arp M, Lasher RA, Seemann G, Doessel O, Hitchcock RW, Sachse FB. Imaging the micro-structure of cardiac tissue by fluorescence confocal microscopy based on quadruple labelling Biomedizinische Technik. 56. DOI: 10.1515/Bmt.2011.835 |
0.776 |
|
2011 |
Dittami GM, Spitzer KW, Rajguru SM, Lasher RA, Hitchcock RW, Rabbitt RD. Mechanisms Underlying Pulsed Infrared Stimulation of Cardiomyocytes Biophysical Journal. 100: 622a. DOI: 10.1016/J.Bpj.2010.12.3577 |
0.754 |
|
2010 |
Coleman TJ, Hsu Y, Nygaard IE, Raynes J, Gordon K, Kumathe M, Hitchcock RW. A Gel filled intravaginal transducer for extended measurements of intra-abdominal pressure. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2010: 1852-5. PMID 21095681 DOI: 10.1109/IEMBS.2010.5625987 |
0.657 |
|
2010 |
Lasher RA, Wolchok JC, Parikh MK, Kennedy JP, Hitchcock RW. Design and characterization of a modified T-flask bioreactor for continuous monitoring of engineered tissue stiffness. Biotechnology Progress. 26: 857-64. PMID 20187075 DOI: 10.1002/Btpr.380 |
0.779 |
|
2010 |
Kennedy JP, McCandless SP, Lasher RA, Hitchcock RW. The mechanically enhanced phase separation of sprayed polyurethane scaffolds and their effect on the alignment of fibroblasts. Biomaterials. 31: 1126-32. PMID 19878993 DOI: 10.1016/J.Biomaterials.2009.10.024 |
0.768 |
|
2010 |
Kennedy JP, Lasher RA, Solomon D, Hitchcock RW. Disinfection of Male Luer Style Connectors for Prevention of Catheter Related Bloodstream Infections Using an Isopropyl Alcohol Dispensing Cap Journal of Medical Devices. 4. DOI: 10.1115/1.3442645 |
0.755 |
|
2009 |
Johnson PJ, Rosenbluth EM, Nygaard IE, Parikh MK, Hitchcock RW. Development of a novel intra-vaginal transducer with improved dynamic response. Biomedical Microdevices. 11: 1213-21. PMID 19629699 DOI: 10.1007/S10544-009-9339-Z |
0.331 |
|
2009 |
Lasher RA, Hitchcock RW, Sachse FB. Towards modeling of cardiac micro-structure with catheter-based confocal microscopy: a novel approach for dye delivery and tissue characterization. Ieee Transactions On Medical Imaging. 28: 1156-64. PMID 19336297 DOI: 10.1109/Tmi.2009.2017376 |
0.779 |
|
2009 |
Lasher RA, Sachse FB, Hitchcock RW. Confocal microscopy and image processing techniques for online monitoring of engineered tissue Proceedings of the Asme Summer Bioengineering Conference 2009, Sbc2009. 1287-1288. DOI: 10.1115/SBC2009-206758 |
0.753 |
|
2009 |
Lasher RA, Parikh MK, Hitchcock RW. A novel bioreactor for continuous monitoring of force-displacement Proceedings of the Asme Summer Bioengineering Conference 2009, Sbc2009. 1003-1004. DOI: 10.1115/SBC2009-205775 |
0.735 |
|
2006 |
Webb K, Hitchcock RW, Smeal RM, Li W, Gray SD, Tresco PA. Cyclic strain increases fibroblast proliferation, matrix accumulation, and elastic modulus of fibroblast-seeded polyurethane constructs. Journal of Biomechanics. 39: 1136-44. PMID 16256125 DOI: 10.1016/J.Jbiomech.2004.08.026 |
0.751 |
|
2005 |
Kim YT, Hitchcock R, Broadhead KW, Messina DJ, Tresco PA. A cell encapsulation device for studying soluble factor release from cells transplanted in the rat brain. Journal of Controlled Release : Official Journal of the Controlled Release Society. 102: 101-11. PMID 15653137 DOI: 10.1016/J.Jconrel.2004.10.003 |
0.721 |
|
2004 |
Titze IR, Hitchcock RW, Broadhead K, Webb K, Li W, Gray SD, Tresco PA. Design and validation of a bioreactor for engineering vocal fold tissues under combined tensile and vibrational stresses. Journal of Biomechanics. 37: 1521-9. PMID 15336927 DOI: 10.1016/J.Jbiomech.2004.01.007 |
0.745 |
|
2004 |
Kim YT, Hitchcock RW, Bridge MJ, Tresco PA. Chronic response of adult rat brain tissue to implants anchored to the skull. Biomaterials. 25: 2229-37. PMID 14741588 DOI: 10.1016/J.Biomaterials.2003.09.010 |
0.757 |
|
2003 |
Webb K, Li W, Hitchcock RW, Smeal RM, Gray SD, Tresco PA. Comparison of human fibroblast ECM-related gene expression on elastic three-dimensional substrates relative to two-dimensional films of the same material. Biomaterials. 24: 4681-90. PMID 12951011 DOI: 10.1016/S0142-9612(03)00368-5 |
0.766 |
|
2001 |
Bridge MJ, Broadhead KW, Hitchcock RW, Webb K, Tresco PA. A simple instrument to characterize convective and diffusive transport of single hollow fibers of short length Journal of Membrane Science. 183: 223-233. DOI: 10.1016/S0376-7388(00)00584-6 |
0.714 |
|
1998 |
Mulder MM, Hitchcock RW, Tresco PA. Skeletal myogenesis on elastomeric substrates: implications for tissue engineering. Journal of Biomaterials Science. Polymer Edition. 9: 731-48. PMID 9686337 DOI: 10.1163/156856298X00118 |
0.602 |
|
Show low-probability matches. |