Year |
Citation |
Score |
2019 |
Kagan ZB, Mize JT, Kosta P, Lazzi G, Normann RA, Warren DJ. Reduced Heat Generation During Magnetic Stimulation of Rat Sciatic Nerve Using Current Waveform Truncation. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. PMID 30990431 DOI: 10.1109/Tnsre.2019.2911054 |
0.404 |
|
2016 |
Normann RA, Fernandez E. Clinical applications of penetrating neural interfaces and Utah Electrode Array technologies. Journal of Neural Engineering. 13: 061003. PMID 27762237 DOI: 10.1088/1741-2560/13/6/061003 |
0.461 |
|
2016 |
Frankel MA, Mathews VJ, Clark GA, Normann RA, Meek SG. Control of Dynamic Limb Motion Using Fatigue-Resistant Asynchronous Intrafascicular Multi-Electrode Stimulation. Frontiers in Neuroscience. 10: 414. PMID 27679557 DOI: 10.3389/Fnins.2016.00414 |
0.622 |
|
2016 |
Kagan Z, RamRakhyani A, Lazzi G, Normann R, Warren D. In Vivo Magnetic Stimulation of Rat Sciatic Nerve with Centimeter- and Millimeter-Scale Solenoid Coils. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. PMID 27019496 DOI: 10.1109/Tnsre.2016.2544247 |
0.426 |
|
2016 |
Davis TS, Wark HA, Hutchinson DT, Warren DJ, O'Neill K, Scheinblum T, Clark GA, Normann RA, Greger B. Restoring motor control and sensory feedback in people with upper extremity amputations using arrays of 96 microelectrodes implanted in the median and ulnar nerves. Journal of Neural Engineering. 13: 036001. PMID 27001946 DOI: 10.1088/1741-2560/13/3/036001 |
0.813 |
|
2015 |
Ramrakhyani A, Kagan Z, Warren D, Normann R, Lazzi G. A μm-scale Computational Model of Magnetic Neural Stimulation in Multifascicular Peripheral Nerves. Ieee Transactions On Bio-Medical Engineering. PMID 26087483 DOI: 10.1109/Tbme.2015.2446761 |
0.402 |
|
2015 |
Wark HA, Black SR, Mathews KS, Cartwright PC, Gustafson KJ, Normann RA. Restoration from acute urinary dysfunction using utah electrode arrays implanted into the feline pudendal nerve. Neuromodulation : Journal of the International Neuromodulation Society. 18: 317-23. PMID 25430001 DOI: 10.1111/Ner.12259 |
0.827 |
|
2014 |
Kagan ZB, RamRakhyani AK, Khan F, Lazzi G, Normann RA, Warren DJ. Magnetic stimulation of mammalian peripheral nerves in vivo: an alternative to functional electrical stimulation. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2014: 2573-6. PMID 25570516 DOI: 10.1109/EMBC.2014.6944148 |
0.323 |
|
2014 |
Clark GA, Wendelken S, Page DM, Davis T, Wark HA, Normann RA, Warren DJ, Hutchinson DT. Using multiple high-count electrode arrays in human median and ulnar nerves to restore sensorimotor function after previous transradial amputation of the hand. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2014: 1977-80. PMID 25570369 DOI: 10.1109/EMBC.2014.6944001 |
0.835 |
|
2014 |
Mathews KS, Wark HA, Warren DJ, Christensen MB, Nolta NF, Cartwright PC, Normann RA. Acute monitoring of genitourinary function using intrafascicular electrodes: selective pudendal nerve activity corresponding to bladder filling, bladder fullness, and genital stimulation. Urology. 84: 722-9. PMID 25168559 DOI: 10.1016/J.Urology.2014.05.021 |
0.857 |
|
2014 |
Fernández E, Greger B, House PA, Aranda I, Botella C, Albisua J, Soto-Sánchez C, Alfaro A, Normann RA. Acute human brain responses to intracortical microelectrode arrays: challenges and future prospects. Frontiers in Neuroengineering. 7: 24. PMID 25100989 DOI: 10.3389/Fneng.2014.00024 |
0.435 |
|
2014 |
Wark HA, Mathews KS, Normann RA, Fernandez E. Behavioral and cellular consequences of high-electrode count Utah Arrays chronically implanted in rat sciatic nerve. Journal of Neural Engineering. 11: 046027. PMID 25031219 DOI: 10.1088/1741-2560/11/4/046027 |
0.831 |
|
2014 |
Mathews KS, Wark HA, Normann RA. Assessment of rat sciatic nerve function following acute implantation of high density Utah slanted electrode array (25 electrodes/mm(2) ) based on neural recordings and evoked muscle activity. Muscle & Nerve. 50: 417-24. PMID 24638985 DOI: 10.1002/mus.24171 |
0.848 |
|
2013 |
Wark HA, Sharma R, Mathews KS, Fernandez E, Yoo J, Christensen B, Tresco P, Rieth L, Solzbacher F, Normann RA, Tathireddy P. A new high-density (25 electrodes/mm²) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures. Journal of Neural Engineering. 10: 045003. PMID 23723133 DOI: 10.1088/1741-2560/10/4/045003 |
0.846 |
|
2012 |
Sharma A, Rieth L, Tathireddy P, Harrison R, Oppermann H, Klein M, Töpper M, Jung E, Normann R, Clark G, Solzbacher F. Evaluation of the packaging and encapsulation reliability in fully integrated, fully wireless 100 channel Utah Slant Electrode Array (USEA): Implications for long term functionality. Sensors and Actuators. a, Physical. 188: 167-172. PMID 23288983 DOI: 10.1016/J.Sna.2011.11.015 |
0.618 |
|
2012 |
Davis TS, Parker RA, House PA, Bagley E, Wendelken S, Normann RA, Greger B. Spatial and temporal characteristics of V1 microstimulation during chronic implantation of a microelectrode array in a behaving macaque. Journal of Neural Engineering. 9: 065003. PMID 23186948 DOI: 10.1088/1741-2560/9/6/065003 |
0.484 |
|
2012 |
Normann RA, Dowden BR, Frankel MA, Wilder AM, Hiatt SD, Ledbetter NM, Warren DA, Clark GA. Coordinated, multi-joint, fatigue-resistant feline stance produced with intrafascicular hind limb nerve stimulation. Journal of Neural Engineering. 9: 026019. PMID 22414699 DOI: 10.1088/1741-2560/9/2/026019 |
0.813 |
|
2012 |
Dowden BR, Frankel MA, Normann RA, Clark GA. Non-invasive method for selection of electrodes and stimulus parameters for FES applications with intrafascicular arrays. Journal of Neural Engineering. 9: 016006. PMID 22173566 DOI: 10.1088/1741-2560/9/1/016006 |
0.847 |
|
2012 |
Frankel MA, Clark GA, Meek SG, Normann RA, Mathews VJ. Adaptive parameter selection for asynchronous intrafascicular multi-electrode stimulation Icassp, Ieee International Conference On Acoustics, Speech and Signal Processing - Proceedings. 753-756. DOI: 10.1109/ICASSP.2012.6287993 |
0.607 |
|
2011 |
Parker RA, Davis TS, House PA, Normann RA, Greger B. The functional consequences of chronic, physiologically effective intracortical microstimulation. Progress in Brain Research. 194: 145-65. PMID 21867801 DOI: 10.1016/B978-0-444-53815-4.00010-8 |
0.441 |
|
2011 |
Sharma A, Rieth L, Tathireddy P, Harrison R, Oppermann H, Klein M, Töpper M, Jung E, Normann R, Clark G, Solzbacher F. Long term in vitro functional stability and recording longevity of fully integrated wireless neural interfaces based on the Utah Slant Electrode Array. Journal of Neural Engineering. 8: 045004. PMID 21775785 DOI: 10.1088/1741-2560/8/4/045004 |
0.627 |
|
2011 |
Torab K, Davis TS, Warren DJ, House PA, Normann RA, Greger B. Multiple factors may influence the performance of a visual prosthesis based on intracortical microstimulation: nonhuman primate behavioural experimentation. Journal of Neural Engineering. 8: 035001. PMID 21593550 DOI: 10.1088/1741-2560/8/3/035001 |
0.516 |
|
2011 |
Butson CR, Miller IO, Normann RA, Clark GA. Selective neural activation in a histologically derived model of peripheral nerve. Journal of Neural Engineering. 8: 036009. PMID 21478574 DOI: 10.1088/1741-2560/8/3/036009 |
0.678 |
|
2011 |
Frankel MA, Dowden BR, Mathews VJ, Normann RA, Clark GA, Meek SG. Multiple-input single-output closed-loop isometric force control using asynchronous intrafascicular multi-electrode stimulation. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 19: 325-32. PMID 21385670 DOI: 10.1109/Tnsre.2011.2123920 |
0.81 |
|
2011 |
Wark HAC, Dowden BR, Cartwright PC, Normann RA. Selective activation of the muscles of micturition using intrafascicular stimulation of the pudendal nerve Ieee Journal On Emerging and Selected Topics in Circuits and Systems. 1: 631-636. DOI: 10.1109/Jetcas.2011.2174490 |
0.838 |
|
2011 |
Sharma R, Tathireddy P, Lee S, Rieth L, Bamberg E, Dorval A, Normann R, Solzbacher F. Application-specific customizable architectures of Utah neural interfaces Procedia Engineering. 25: 1016-1019. DOI: 10.1016/J.Proeng.2011.12.250 |
0.445 |
|
2010 |
Dowden BR, Wark HA, Normann RA. Muscle-selective block using intrafascicular high-frequency alternating current. Muscle & Nerve. 42: 339-47. PMID 20806397 DOI: 10.1002/Mus.21678 |
0.819 |
|
2009 |
Dowden BR, Wilder AM, Hiatt SD, Normann RA, Brown NA, Clark GA. Selective and graded recruitment of cat hamstring muscles with intrafascicular stimulation. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 17: 545-52. PMID 19696002 DOI: 10.1109/Tnsre.2008.2011988 |
0.824 |
|
2009 |
Wilder AM, Hiatt SD, Dowden BR, Brown NA, Normann RA, Clark GA. Automated stimulus-response mapping of high-electrode-count neural implants. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 17: 504-11. PMID 19666339 DOI: 10.1109/Tnsre.2009.2029494 |
0.825 |
|
2009 |
Normann RA, Greger B, Greger BA, House P, Romero SF, Pelayo F, Fernandez E. Toward the development of a cortically based visual neuroprosthesis. Journal of Neural Engineering. 6: 035001. PMID 19458403 DOI: 10.1088/1741-2552/6/4/049802 |
0.324 |
|
2009 |
Hsu JM, Rieth L, Normann RA, Tathireddy P, Solzbacher F. Encapsulation of an integrated neural interface device with Parylene C. Ieee Transactions On Bio-Medical Engineering. 56: 23-9. PMID 19224715 DOI: 10.1109/Tbme.2008.2002155 |
0.382 |
|
2009 |
Gunalan K, Warren DJ, Perry JD, Normann RA, Clark GA. An automated system for measuring tip impedance and among-electrode shunting in high-electrode count microelectrode arrays. Journal of Neuroscience Methods. 178: 263-9. PMID 19150630 DOI: 10.1016/j.jneumeth.2008.12.020 |
0.655 |
|
2009 |
Bhandari R, Negi S, Rieth L, Normann RA, Solzbacher F. A novel masking method for high aspect ratio penetrating microelectrode arrays Journal of Micromechanics and Microengineering. 19. DOI: 10.1088/0960-1317/19/3/035004 |
0.459 |
|
2008 |
Bhandari R, Negi S, Rieth L, Normann RA, Solzbacher F. A Novel Method of Fabricating Convoluted Shaped Electrode Arrays for Neural and Retinal Prostheses. Sensors and Actuators. a, Physical. 145: 123-130. PMID 19122774 DOI: 10.1016/J.Sna.2007.10.072 |
0.508 |
|
2007 |
Kim S, Tathireddy P, Normann RA, Solzbacher F. Thermal impact of an active 3-D microelectrode array implanted in the brain. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 15: 493-501. PMID 18198706 DOI: 10.1109/Tnsre.2007.908429 |
0.336 |
|
2007 |
Mushahwar VK, Jacobs PL, Normann RA, Triolo RJ, Kleitman N. New functional electrical stimulation approaches to standing and walking. Journal of Neural Engineering. 4: S181-97. PMID 17873417 DOI: 10.1088/1741-2560/4/3/S05 |
0.362 |
|
2007 |
Normann RA. Technology insight: future neuroprosthetic therapies for disorders of the nervous system. Nature Clinical Practice. Neurology. 3: 444-52. PMID 17671522 DOI: 10.1038/ncpneuro0556 |
0.427 |
|
2007 |
Kim SJ, Badi AN, Normann RA. Selective activation of cat primary auditory cortex by way of direct intraneural auditory nerve stimulation. The Laryngoscope. 117: 1053-62. PMID 17545868 DOI: 10.1097/Mlg.0B013E31804714A7 |
0.827 |
|
2007 |
Badi AN, Owa AO, Shelton C, Normann RA. Electrode independence in intraneural cochlear nerve stimulation. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 28: 16-24. PMID 17195741 DOI: 10.1097/01.Mao.0000244368.70190.38 |
0.839 |
|
2007 |
Bhandari R, Negi S, Rieth L, Normann RA, Solzbacher F. A novel method of fabricating convoluted shaped electrode arrays for neural and retinal prosthesis Transducers and Eurosensors '07 - 4th International Conference On Solid-State Sensors, Actuators and Microsystems. 1231-1234. DOI: 10.1109/SENSOR.2007.4300359 |
0.325 |
|
2007 |
Berger D, Warren D, Normann R, Arieli A, Grün S. Spatially organized spike correlation in cat visual cortex Neurocomputing. 70: 2112-2116. DOI: 10.1016/J.Neucom.2006.10.141 |
0.322 |
|
2006 |
House PA, MacDonald JD, Tresco PA, Normann RA. Acute microelectrode array implantation into human neocortex: preliminary technique and histological considerations. Neurosurgical Focus. 20: E4. PMID 16711661 DOI: 10.3171/Foc.2006.20.5.5 |
0.397 |
|
2006 |
Kim SJ, Manyam SC, Warren DJ, Normann RA. Electrophysiological mapping of cat primary auditory cortex with multielectrode arrays. Annals of Biomedical Engineering. 34: 300-9. PMID 16496084 DOI: 10.1007/s10439-005-9037-9 |
0.624 |
|
2006 |
Guillory KS, Shoham S, Normann RA. Discrete stimulus estimation from neural responses in the turtle retina. Vision Research. 46: 1876-85. PMID 16442582 DOI: 10.1016/j.visres.2005.12.001 |
0.656 |
|
2006 |
Lehmkuhle MJ, Normann RA, Maynard EM. Trial-by-trial discrimination of three enantiomer pairs by neural ensembles in mammalian olfactory bulb. Journal of Neurophysiology. 95: 1369-79. PMID 16306170 DOI: 10.1152/jn.01334.2004 |
0.736 |
|
2005 |
Normann R, McDonnall D, Clark G. Control of skeletal muscle force with currents injected via an intrafascicular, microelectrode array. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 7: 7644-7. PMID 17282051 DOI: 10.1109/IEMBS.2005.1616282 |
0.84 |
|
2005 |
Shoham S, Paninski LM, Fellows MR, Hatsopoulos NG, Donoghue JP, Normann RA. Statistical encoding model for a primary motor cortical brain-machine interface. Ieee Transactions On Bio-Medical Engineering. 52: 1312-22. PMID 16041995 DOI: 10.1109/TBME.2005.847542 |
0.633 |
|
2005 |
Warren DJ, Normann RA. Functional reorganization of primary visual cortex induced by electrical stimulation in the cat. Vision Research. 45: 551-65. PMID 15621174 DOI: 10.1016/j.visres.2004.09.021 |
0.364 |
|
2005 |
Normann RA, McDonnall D, Clark GA, Stein RB, Branner A. Physiological activation of the hind limb muscles of the anesthetized cat using the utah slanted electrode array Proceedings of the International Joint Conference On Neural Networks. 5: 3103-3108. DOI: 10.1109/IJCNN.2005.1556422 |
0.814 |
|
2005 |
BADI A, KELLER C, NORMANN R, FRIEDLAND D. Three Dimensional Computed Tomography Reconstruction of the Temporal Bone at 21 Micron Resolution Otolaryngology - Head and Neck Surgery. 133: P84-P84. DOI: 10.1016/J.Otohns.2005.05.175 |
0.74 |
|
2005 |
Solzbacher F, Harrison R, Normann R, Oppermann H, Klein M, Koch K. Integrated neural interfaces arrays for neuroprosthetics applications Nanomedicine: Nanotechnology, Biology and Medicine. 1: 250-251. DOI: 10.1016/J.Nano.2005.09.028 |
0.333 |
|
2005 |
Normann RA, McDonnall D, Clark GA. Control of skeletal muscle force with currents injected via an intrafascicular, microelectrode array Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 7: 7644-7647. |
0.788 |
|
2004 |
Stein RB, Aoyagi Y, Weber DJ, Shoham S, Normann RA. Encoding mechanisms for sensory neurons studied with a multielectrode array in the cat dorsal root ganglion. Canadian Journal of Physiology and Pharmacology. 82: 757-68. PMID 15523533 DOI: 10.1139/Y04-075 |
0.654 |
|
2004 |
McDonnall D, Clark GA, Normann RA. Selective motor unit recruitment via intrafascicular multielectrode stimulation. Canadian Journal of Physiology and Pharmacology. 82: 599-609. PMID 15523517 DOI: 10.1139/Y04-047 |
0.836 |
|
2004 |
Stein RB, Weber DJ, Aoyagi Y, Prochazka A, Wagenaar JB, Shoham S, Normann RA. Coding of position by simultaneously recorded sensory neurones in the cat dorsal root ganglion. The Journal of Physiology. 560: 883-96. PMID 15331686 DOI: 10.1113/Jphysiol.2004.068668 |
0.652 |
|
2004 |
McDonnall D, Clark GA, Normann RA. Interleaved, multisite electrical stimulation of cat sciatic nerve produces fatigue-resistant, ripple-free motor responses. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 12: 208-15. PMID 15218935 DOI: 10.1109/TNSRE.2004.828425 |
0.825 |
|
2004 |
Branner A, Stein RB, Fernandez E, Aoyagi Y, Normann RA. Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve. Ieee Transactions On Bio-Medical Engineering. 51: 146-57. PMID 14723504 DOI: 10.1109/Tbme.2003.820321 |
0.84 |
|
2004 |
Ma KL, Kindlmann G, Normann RA, Badi A, Keller C, Jones GM, Johnson CR. Scientific visualization in small animal imaging Computer Graphics (Acm). 38: 4-7. DOI: 10.1145/1012283.1012291 |
0.625 |
|
2003 |
Hillman T, Badi AN, Normann RA, Kertesz T, Shelton C. Cochlear nerve stimulation with a 3-dimensional penetrating electrode array. Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 24: 764-8. PMID 14501454 DOI: 10.1097/00129492-200309000-00013 |
0.846 |
|
2003 |
Aoyagi Y, Stein RB, Branner A, Pearson KG, Normann RA. Capabilities of a penetrating microelectrode array for recording single units in dorsal root ganglia of the cat. Journal of Neuroscience Methods. 128: 9-20. PMID 12948544 DOI: 10.1016/S0165-0270(03)00143-2 |
0.816 |
|
2003 |
Lehmkuhle MJ, Normann RA, Maynard EM. High-resolution analysis of the spatio-temporal activity patterns in rat olfactory bulb evoked by enantiomer odors. Chemical Senses. 28: 499-508. PMID 12907587 DOI: 10.1093/chemse/28.6.499 |
0.75 |
|
2003 |
Shoham S, Fellows MR, Normann RA. Robust, automatic spike sorting using mixtures of multivariate t-distributions. Journal of Neuroscience Methods. 127: 111-22. PMID 12906941 DOI: 10.1016/S0165-0270(03)00120-1 |
0.611 |
|
2003 |
Badi AN, Kertesz TR, Gurgel RK, Shelton C, Normann RA. Development of a novel eighth-nerve intraneural auditory neuroprosthesis. The Laryngoscope. 113: 833-42. PMID 12792319 DOI: 10.1097/00005537-200305000-00012 |
0.839 |
|
2003 |
Normann RA. Microfabricated electrode arrays for restoring lost sensory and motor functions Transducers 2003 - 12th International Conference On Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers. 2: 959-962. DOI: 10.1109/SENSOR.2003.1216926 |
0.327 |
|
2002 |
Badi AN, Hillman T, Shelton C, Normann RA. A technique for implantation of a 3-dimensional penetrating electrode array in the modiolar nerve of cats and humans. Archives of Otolaryngology--Head & Neck Surgery. 128: 1019-25. PMID 12220205 DOI: 10.1001/Archotol.128.9.1019 |
0.824 |
|
2001 |
Shoham S, Halgren E, Maynard EM, Normann RA. Motor-cortical activity in tetraplegics. Nature. 413: 793. PMID 11677592 DOI: 10.1038/35101651 |
0.629 |
|
2001 |
Warren DJ, Fernandez E, Normann RA. High-resolution two-dimensional spatial mapping of cat striate cortex using a 100-microelectrode array. Neuroscience. 105: 19-31. PMID 11483297 DOI: 10.1016/S0306-4522(01)00174-9 |
0.343 |
|
2001 |
Normann RA, Warren DJ, Ammermuller J, Fernandez E, Guillory S. High-resolution spatio-temporal mapping of visual pathways using multi-electrode arrays. Vision Research. 41: 1261-75. PMID 11322971 DOI: 10.1016/S0042-6989(00)00273-X |
0.753 |
|
2001 |
Branner A, Stein RB, Normann RA. Selective stimulation of cat sciatic nerve using an array of varying-length microelectrodes. Journal of Neurophysiology. 85: 1585-94. PMID 11287482 DOI: 10.1152/Jn.2001.85.4.1585 |
0.844 |
|
2001 |
Ferrández JM, Bongard M, De Quirós FG, Bolea JA, Ammermüller J, Normann RA, Fernández E. Decoding the population responses of retinal ganglions cells using information theory Lecture Notes in Computer Science (Including Subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics). 2084: 55-62. |
0.707 |
|
2000 |
Fernández E, Ferrandez J, Ammermüller J, Normann RA. Population coding in spike trains of simultaneously recorded retinal ganglion cells. Brain Research. 887: 222-9. PMID 11134610 DOI: 10.1016/S0006-8993(00)03072-9 |
0.761 |
|
2000 |
Maynard EM, Fernandez E, Normann RA. A technique to prevent dural adhesions to chronically implanted microelectrode arrays. Journal of Neuroscience Methods. 97: 93-101. PMID 10788663 DOI: 10.1016/S0165-0270(00)00159-X |
0.463 |
|
2000 |
Branner A, Normann RA. A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats. Brain Research Bulletin. 51: 293-306. PMID 10704779 DOI: 10.1016/S0361-9230(99)00231-2 |
0.843 |
|
2000 |
Clark G, Normann R, Tresco P. Neural interfaces laboratory in bioengineering Annals of Biomedical Engineering. 28: S-106. |
0.503 |
|
1999 |
Guillory KS, Normann RA. A 100-channel system for real time detection and storage of extracellular spike waveforms. Journal of Neuroscience Methods. 91: 21-9. PMID 10522821 DOI: 10.1016/S0165-0270(99)00076-X |
0.419 |
|
1999 |
Normann RA, Maynard EM, Rousche PJ, Warren DJ. A neural interface for a cortical vision prosthesis. Vision Research. 39: 2577-87. PMID 10396626 DOI: 10.1016/S0042-6989(99)00040-1 |
0.761 |
|
1999 |
Rousche PJ, Normann RA. Chronic intracortical microstimulation (ICMS) of cat sensory cortex using the Utah Intracortical Electrode Array. Ieee Transactions On Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 7: 56-68. PMID 10188608 DOI: 10.1109/86.750552 |
0.775 |
|
1999 |
Branner A, Stein RB, Normann RA. Selective stimulation and recording using a slanted multielectrode array Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 1: 377. |
0.789 |
|
1999 |
Normann RA, Branner A. Multichannel, neural interface for the peripheral nervous system Proceedings of the Ieee International Conference On Systems, Man and Cybernetics. 4: IV-370 - IV-375. |
0.755 |
|
1999 |
Guillory KS, Normann RA. PC-based data acquisition system for arrays of 100 extracellular electrodes Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 1: 454. |
0.307 |
|
1998 |
Rousche PJ, Normann RA. Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex. Journal of Neuroscience Methods. 82: 1-15. PMID 10223510 DOI: 10.1016/S0165-0270(98)00031-4 |
0.779 |
|
1997 |
Jones KE, Normann RA. An advanced demultiplexing system for physiological stimulation. Ieee Transactions On Bio-Medical Engineering. 44: 1210-20. PMID 9401220 DOI: 10.1109/10.649992 |
0.377 |
|
1997 |
Maynard EM, Nordhausen CT, Normann RA. The Utah intracortical Electrode Array: a recording structure for potential brain-computer interfaces. Electroencephalography and Clinical Neurophysiology. 102: 228-39. PMID 9129578 DOI: 10.1016/S0013-4694(96)95176-0 |
0.398 |
|
1997 |
Shoham S, Osan R, Ammermuller J, Branner A, Fernandez E, Normann RA. The classification of spatial, chromatic, and intensity features of simple visual stimuli by a network of retinal ganglion cells Lecture Notes in Computer Science (Including Subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics). 1240: 44-53. |
0.756 |
|
1997 |
Normann RA, Ammermuller J, Shoham S, Branner A. Color and intensity information representations by a network of turtle retinal ganglion cells Ieee International Conference On Neural Networks - Conference Proceedings. 4: 2333-2336. |
0.77 |
|
1996 |
Nordhausen CT, Maynard EM, Normann RA. Single unit recording capabilities of a 100 microelectrode array. Brain Research. 726: 129-40. PMID 8836553 DOI: 10.1016/S0006-8993(96)00321-6 |
0.495 |
|
1996 |
Normann R, Maynard E, Guillory K, Warren D. Cortical implants for the blind Ieee Spectrum. 33: 54-59. DOI: 10.1109/6.490057 |
0.387 |
|
1995 |
Normann RA. Visual Neuroprosthetics—Functional Vision for the Blind Ieee Engineering in Medicine and Biology Magazine. 14: 77-83. DOI: 10.1109/51.340752 |
0.403 |
|
1994 |
Nordhausen CT, Rousche PJ, Normann RA. Optimizing recording capabilities of the Utah Intracortical Electrode Array. Brain Research. 637: 27-36. PMID 8180807 DOI: 10.1016/0006-8993(94)91213-0 |
0.773 |
|
1993 |
Schmidt S, Horch K, Normann R. Biocompatibility of silicon-based electrode arrays implanted in feline cortical tissue Journal of Biomedical Materials Research. 27: 1393-1399. PMID 8263001 DOI: 10.1002/Jbm.820271106 |
0.411 |
|
1992 |
Cha K, Horch KW, Normann RA, Boman DK. Reading speed with a pixelized vision system. Journal of the Optical Society of America. a, Optics and Image Science. 9: 673-7. PMID 1588454 DOI: 10.1364/Josaa.9.000673 |
0.346 |
|
1992 |
Cha K, Horch K, Normann RA. Simulation of a phosphene-based visual field: visual acuity in a pixelized vision system. Annals of Biomedical Engineering. 20: 439-49. PMID 1510295 DOI: 10.1007/Bf02368135 |
0.353 |
|
1992 |
Jones KE, Campbell PK, Normann RA. A glass/silicon composite intracortical electrode array. Annals of Biomedical Engineering. 20: 423-37. PMID 1510294 DOI: 10.1007/BF02368134 |
0.436 |
|
1992 |
Rousche PJ, Normann RA. A method for pneumatically inserting an array of penetrating electrodes into cortical tissue. Annals of Biomedical Engineering. 20: 413-22. PMID 1510293 DOI: 10.1007/Bf02368133 |
0.749 |
|
1992 |
Johansson T, Abbasi M, Huber RJ, Normann RA. A three-dimensional architecture for a parallel processing photosensing array. Ieee Transactions On Bio-Medical Engineering. 39: 1292-7. PMID 1487292 DOI: 10.1109/10.184705 |
0.304 |
|
1992 |
Ammermüller J, Kolb H, Normann R. Color pathways in the inner plexiform layer of the turtle retina Experimental Eye Research. 55: 244. DOI: 10.1016/0014-4835(92)91063-4 |
0.695 |
|
1991 |
Campbell PK, Jones KE, Huber RJ, Horch KW, Normann RA. A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array. Ieee Transactions On Bio-Medical Engineering. 38: 758-68. PMID 1937509 DOI: 10.1109/10.83588 |
0.431 |
|
1991 |
Muller JF, Ammermüller J, Normann RA, Kolb H. Synaptic inputs to physiologically defined turtle retinal ganglion cells. Visual Neuroscience. 7: 409-29. PMID 1764412 DOI: 10.1017/S0952523800009718 |
0.731 |
|
1990 |
Campbell PK, Jones KE, Normann RA. A 100 electrode intracortical array: structural variability. Biomedical Sciences Instrumentation. 26: 161-5. PMID 2334761 |
0.35 |
|
1990 |
Ammermüller J, Guiloff G, Normann R, Kolb H. A 'puff and advance' technique for visually controlled staining of turtle retinal ganglion cells. Journal of Neuroscience Methods. 32: 235-43. PMID 1696675 DOI: 10.1016/0165-0270(90)90146-7 |
0.332 |
|
1989 |
Campbell PK, Normann RA, Horch KW, Stensaas SS. A chronic intracortical electrode array: preliminary results. Journal of Biomedical Materials Research. 23: 245-59. PMID 2674149 |
0.374 |
|
Show low-probability matches. |