Year |
Citation |
Score |
2020 |
Johnson LC, Guerraty MA, Moore SC, Metzler SD. Quantification of defect contrast in microSPECT imaging of a myocardial phantom. Physics in Medicine and Biology. PMID 32369789 DOI: 10.1088/1361-6560/Ab9065 |
0.335 |
|
2019 |
Metzler SD, Moore SC. Analytic Determination of Rectangular-Pinhole Sensitivity With Penetration. Ieee Transactions On Medical Imaging. PMID 31425068 DOI: 10.1109/Tmi.2019.2936187 |
0.311 |
|
2019 |
Johnson LC, Guerraty MA, Moore SC, Metzler SD. Quantification of myocardial uptake rate constants in dynamic small-animal SPECT using a cardiac phantom. Physics in Medicine and Biology. PMID 30721887 DOI: 10.1088/1361-6560/Ab0472 |
0.356 |
|
2017 |
Cal-Gonzalez J, Li X, Heber D, Rausch I, Moore SC, Schäfers K, Hacker M, Beyer T. Partial volume correction for improved PET quantification in (18)F-NaF imaging of atherosclerotic plaques. Journal of Nuclear Cardiology : Official Publication of the American Society of Nuclear Cardiology. PMID 28176255 DOI: 10.1007/S12350-017-0778-2 |
0.314 |
|
2016 |
Moore SC, Park MA, Liu Z, Lyon MC, Johnson LC, Lushear VH, Westberg JG, Metzler SD. Design of a dual-resolution collimator for preclinical cardiac SPECT with a stationary triple-detector system. Medical Physics. 43: 6336. PMID 27908172 DOI: 10.1118/1.4966697 |
0.361 |
|
2016 |
Lyon MC, Sitek A, Metzler SD, Moore SC. Reconstruction of multiple-pinhole micro-SPECT data using origin ensembles. Medical Physics. 43: 5475. PMID 27782695 DOI: 10.1118/1.4962480 |
0.371 |
|
2016 |
Park MA, Kijewski MF, Keijzers R, Keijzers M, Lyon MC, Horky L, Moore SC. Introduction of a novel ultrahigh sensitivity collimator for brain SPECT imaging. Medical Physics. 43: 4734. PMID 27487891 DOI: 10.1118/1.4958962 |
0.334 |
|
2016 |
Lyon MC, Foster C, Ding X, Dorbala S, Spence D, Bhattacharya M, Vija AH, DiCarli MF, Moore SC. Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation. Journal of Nuclear Cardiology : Official Publication of the American Society of Nuclear Cardiology. PMID 27033352 DOI: 10.1007/S12350-016-0471-X |
0.325 |
|
2016 |
Johnson LC, Moore SC, Metzler SD. Effect of pinhole shape on projection resolution. Physics in Medicine and Biology. 61: 2003-2013. PMID 26894917 DOI: 10.1088/0031-9155/61/5/2003 |
0.344 |
|
2015 |
Xia D, Moore SC, Park MA, Cervo M, Metzler SD. Investigation of imaging properties for submillimeter rectangular pinholes. Medical Physics. 42: 6933. PMID 26632049 DOI: 10.1118/1.4935200 |
0.344 |
|
2015 |
Van Audenhaege K, Van Holen R, Vandenberghe S, Vanhove C, Metzler SD, Moore SC. Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging. Medical Physics. 42: 4796. PMID 26233207 DOI: 10.1118/1.4927061 |
0.333 |
|
2015 |
Drozdovitch V, Brill AB, Callahan RJ, Clanton JA, DePietro A, Goldsmith SJ, Greenspan BS, Gross MD, Hays MT, Moore SC, Ponto JA, Shreeve WW, Melo DR, Linet MS, Simon SL. Use of radiopharmaceuticals in diagnostic nuclear medicine in the United States: 1960-2010. Health Physics. 108: 520-37. PMID 25811150 DOI: 10.1097/Hp.0000000000000261 |
0.31 |
|
2015 |
Dorbala S, Blankstein R, Skali H, Park MA, Fantony J, Mauceri C, Semer J, Moore SC, Di Carli MF. Approaches to reducing radiation dose from radionuclide myocardial perfusion imaging. Journal of Nuclear Medicine : Official Publication, Society of Nuclear Medicine. 56: 592-9. PMID 25766891 DOI: 10.2967/Jnumed.112.115097 |
0.315 |
|
2015 |
Cal-González J, Lage E, Herranz E, Vicente E, Udias JM, Moore SC, Park MA, Dave SR, Parot V, Herraiz JL. Simulation of triple coincidences in PET. Physics in Medicine and Biology. 60: 117-36. PMID 25479147 DOI: 10.1088/0031-9155/60/1/117 |
0.319 |
|
2015 |
Willowson KP, Tapner M, The QUEST Investigator Team, Bailey DL, Tapner MJ, Ahmadzadehfar H, Amthauer H, Großer OS, Arbizu J, Martí-Climent JM, Rodriguez-Fraile M, Attarwala AA, Glatting G, Molina-Duran F, Bagni O, ... ... Moore SC, et al. A multicentre comparison of quantitative 90Y PET/CT for dosimetric purposes after radioembolization with resin microspheres: The QUEST Phantom Study European Journal of Nuclear Medicine and Molecular Imaging. 42: 1202-1222. DOI: 10.1007/S00259-015-3059-9 |
0.301 |
|
2014 |
Park M, Kijewski M, Horky L, Keijzers M, Keijzers R, Kalfin L, Crough J, Goswami M, Moore S. SU-C-9A-07: Fabrication and Calibration of a Novel High-Sensitivity Collimator for Brain SPECT Imaging. Medical Physics. 41: 106. PMID 28037334 DOI: 10.1118/1.4887848 |
0.315 |
|
2013 |
Cervo M, Gerbaudo VH, Park MA, Moore SC. Quantitative simultaneous 111In∕99mTc SPECT-CT of osteomyelitis. Medical Physics. 40: 082501. PMID 23927346 DOI: 10.1118/1.4812421 |
0.377 |
|
2013 |
Sitek A, Moore SC. Evaluation of imaging systems using the posterior variance of emission counts. Ieee Transactions On Medical Imaging. 32: 1829-39. PMID 23744672 DOI: 10.1109/Tmi.2013.2265886 |
0.319 |
|
2013 |
Ben-Haim S, Murthy VL, Breault C, Allie R, Sitek A, Roth N, Fantony J, Moore SC, Park MA, Kijewski M, Haroon A, Slomka P, Erlandsson K, Baavour R, Zilberstien Y, et al. Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study. Journal of Nuclear Medicine : Official Publication, Society of Nuclear Medicine. 54: 873-9. PMID 23578996 DOI: 10.2967/Jnumed.112.109652 |
0.33 |
|
2013 |
Park MA, Moore SC, Müller SP, McQuaid SJ, Kijewski MF. Performance of a high-sensitivity dedicated cardiac SPECT scanner for striatal uptake quantification in the brain based on analysis of projection data. Medical Physics. 40: 042504. PMID 23556920 DOI: 10.1118/1.4794488 |
0.355 |
|
2012 |
Southekal S, McQuaid SJ, Kijewski MF, Moore SC. Evaluation of a method for projection-based tissue-activity estimation within small volumes of interest. Physics in Medicine and Biology. 57: 685-701. PMID 22241591 DOI: 10.1088/0031-9155/57/3/685 |
0.335 |
|
2012 |
Moore SC, Southekal S, Park MA, McQuaid SJ, Kijewski MF, Müller SP. Improved regional activity quantitation in nuclear medicine using a new approach to correct for tissue partial volume and spillover effects. Ieee Transactions On Medical Imaging. 31: 405-16. PMID 21965196 DOI: 10.1109/Tmi.2011.2169981 |
0.343 |
|
2008 |
Ouyang J, El Fakhri G, Moore SC. Improved activity estimation with MC-JOSEM versus TEW-JOSEM in 111In SPECT. Medical Physics. 35: 2029-40. PMID 18561679 DOI: 10.1118/1.2907561 |
0.322 |
|
2008 |
Park MA, Zimmerman RE, Taberner A, Kaye MW, Moore SC. Design and fabrication of phantoms using stereolithography for small-animal imaging systems. Molecular Imaging and Biology : Mib : the Official Publication of the Academy of Molecular Imaging. 10: 231-6. PMID 18546047 DOI: 10.1007/S11307-008-0150-7 |
0.324 |
|
2008 |
Park MA, Mahmood A, Zimmerman RE, Limpa-Amara N, Makrigiorgos GM, Moore SC. Adsorption of metallic radionuclides on plastic phantom walls. Medical Physics. 35: 1606-10. PMID 18491554 DOI: 10.1118/1.2871191 |
0.303 |
|
2007 |
Zhu X, Park MA, Gerbaudo VH, Moore SC. Quantitative simultaneous In-111/Tc-99m planar imaging in a long-bone infection phantom. Physics in Medicine and Biology. 52: 7353-65. PMID 18065843 DOI: 10.1088/0031-9155/52/24/010 |
0.359 |
|
2007 |
Ouyang J, El Fakhri G, Moore SC. Fast Monte Carlo based joint iterative reconstruction for simultaneous 99mTc/ 123I SPECT imaging. Medical Physics. 34: 3263-72. PMID 17879789 DOI: 10.1118/1.2756601 |
0.312 |
|
2007 |
Di Carli MF, Dorbala S, Meserve J, El Fakhri G, Sitek A, Moore SC. Clinical myocardial perfusion PET/CT. Journal of Nuclear Medicine : Official Publication, Society of Nuclear Medicine. 48: 783-93. PMID 17475968 DOI: 10.2967/Jnumed.106.032789 |
0.314 |
|
2006 |
Moore SC, Ouyang J, Park MA, El Fakhri G. Monte Carlo-based compensation for patient scatter, detector scatter, and crosstalk contamination in In-111 SPECT imaging Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 569: 472-476. DOI: 10.1016/J.Nima.2006.08.079 |
0.326 |
|
2006 |
Park MA, Kijewski MF, Moore SC. Effects of hole tapering on cone-beam collimation for brain SPECT imaging Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 569: 188-192. DOI: 10.1016/J.Nima.2006.08.015 |
0.314 |
|
2005 |
Park MA, Moore SC, Kijewski MF. Brain SPECT with short focal-length cone-beam collimation. Medical Physics. 32: 2236-2244. PMID 28493590 DOI: 10.1118/1.1929208 |
0.349 |
|
2005 |
Moore SC, Foley Kijewski M, El Fakhri G. Collimator optimization for detection and quantitation tasks: application to gallium-67 imaging. Ieee Transactions On Medical Imaging. 24: 1347-56. PMID 16229420 DOI: 10.1109/Tmi.2005.857211 |
0.338 |
|
2002 |
El Fakhri G, Moore SC, Kijewski MF. Optimization of Ga-67 imaging for detection and estimation tasks: dependence of imaging performance on spectral acquisition parameters. Medical Physics. 29: 1859-66. PMID 12201433 DOI: 10.1118/1.1493214 |
0.31 |
|
2002 |
Fakhri GE, Maksud P, Kijewski MF, Zimmerman RE, Moore SC. Quantitative simultaneous /sup 99m/Tc//sup 123/I SPECT: design study and validation with Monte Carlo simulations and physical acquisitions Ieee Transactions On Nuclear Science. 49: 2315-2321. DOI: 10.1109/Tns.2002.803819 |
0.304 |
|
2001 |
Moore SC, Kijewski MF, Müller SP, Rybicki F, Zimmerman RE. Evaluation of scatter compensation methods by their effects on parameter estimation from SPECT projections. Medical Physics. 28: 278-87. PMID 11243353 DOI: 10.1118/1.1344201 |
0.31 |
|
2001 |
Fakhri GE, Kijewski MF, Moore SC. Absolute activity quantitation from projections using an analytical approach: comparison with iterative methods in Tc-99m and I-123 brain SPECT Ieee Transactions On Nuclear Science. 48: 768-773. DOI: 10.1109/23.940161 |
0.327 |
|
2001 |
Moore SC, Fakhri GE. Realistic Monte Carlo simulation of Ga-67 SPECT imaging Ieee Transactions On Nuclear Science. 48: 720-724. DOI: 10.1109/23.940153 |
0.362 |
|
2000 |
Fakhri GE, Maksud P, Kijewski MF, Haberi MO, Todd-Pokropek A, Aurengo A, Moore SC. Scatter and cross-talk corrections in simultaneous Tc-99m/I-123 brain SPECT using constrained factor analysis and artificial neural networks Ieee Transactions On Nuclear Science. 47: 1573-1580. DOI: 10.1109/23.873018 |
0.316 |
|
1995 |
Moore SC, deVries DJ, Nandram B, Kijewski MF, Mueller SP. Collimator optimization for lesion detection incorporating prior information about lesion size. Medical Physics. 22: 703-13. PMID 7565359 DOI: 10.1118/1.597466 |
0.313 |
|
1994 |
Walsh EG, Minematsu K, Leppo J, Moore SC. Radioactive microsphere validation of a volume localized continuous saturation perfusion measurement. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 31: 147-53. PMID 8133750 DOI: 10.1002/Mrm.1910310208 |
0.523 |
|
1992 |
Moore SC, Kouris K, Cullum I. Collimator design for single photon emission tomography. European Journal of Nuclear Medicine. 19: 138-50. PMID 1563442 DOI: 10.1007/Bf00184130 |
0.322 |
|
1992 |
Donoghue C, Brideau M, Newcomer P, Pangrle B, DiBiasio D, Walsh E, Moore S. Use of magnetic resonance imaging to analyze the performance of hollow- fiber bioreactors Annals of the New York Academy of Sciences. 665: 285-300. PMID 1416611 DOI: 10.1111/J.1749-6632.1992.Tb42592.X |
0.532 |
|
1992 |
Gagnon D, Laperriere L, Pouliot N, Vries DJd, Moore SC. Monte Carlo analysis of camera-induced spectral contamination for different primary energies Physics in Medicine and Biology. 37: 1725-1739. DOI: 10.1088/0031-9155/37/9/001 |
0.3 |
|
1992 |
Pangrle BJ, Walsh EG, Moore SC, DiBiasio D. Magnetic resonance imaging of laminar flow in porous tube and shell systems Chemical Engineering Science. 47: 517-526. DOI: 10.1016/0009-2509(92)80001-S |
0.539 |
|
1991 |
Sotak CH, Moore SC. A volume-localized, two-dimensional NMR method for lactate-edited diffusion coefficient measurements using zero-quantum coherence-transfer spectroscopy Journal of Magnetic Resonance (1969). 92: 581-589. DOI: 10.1016/0022-2364(91)90352-T |
0.54 |
|
1990 |
De Vries DJ, Moore SC, Zimmerman RE, Mueller SP, Friedland B, Lanza RC. Development and validation of a Monte Carlo simulation of photon transport in an Anger camera. Ieee Transactions On Medical Imaging. 9: 430-8. PMID 18222790 DOI: 10.1109/42.61758 |
0.314 |
|
1989 |
Pangrle BJ, Walsh EG, Moore S, DiBiasio D. Investigation of fluid flow patterns in a hollow fiber module using magnetic resonance velocity imaging Biotechnology Techniques. 3: 67-72. DOI: 10.1007/Bf01876224 |
0.534 |
|
1987 |
Moore SC, Judy PF. Cardiac computed tomography using redundant-ray prospective gating. Medical Physics. 14: 193-6. PMID 3587137 DOI: 10.1118/1.596134 |
0.322 |
|
1983 |
Moore SC, Judy PF, Garnic JD, Kambic GX, Bonk F, Cochran G, Margosian P, McCroskey W, Foote F. Prospectively gated cardiac computed tomography. Medical Physics. 10: 846-55. PMID 6361507 DOI: 10.1118/1.595420 |
0.311 |
|
Show low-probability matches. |