Alonso N. Gutierrez, Ph.D. - Publications

Affiliations: 
2007 University of Wisconsin, Madison, Madison, WI 
Area:
Radiation Physics, Medical Biophysics

162 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2024 La Rosa A, Mittauer KE, Bassiri N, Rzepczynski AE, Chuong MD, Yarlagadda S, Kutuk T, McAllister NC, Hall MD, Gutierrez AN, Tolakanahalli R, Mehta MP, Kotecha R. Accelerated Hypofractionated Magnetic Resonance Guided Adaptive Radiation Therapy for Ultracentral Lung Tumors. Tomography (Ann Arbor, Mich.). 10: 169-180. PMID 38250959 DOI: 10.3390/tomography10010013  0.675
2023 Barsky AR, George J, Wroe AJ, Mittauer KE, Kaiser A, Herrera R, Yu J, Gutierrez AN, Alvarez D, McCulloch J, Kasper ME, Mehta MP, Chuong MD. Dosimetric comparison of magnetic resonance-guided radiation therapy, intensity-modulated proton therapy and volumetric-modulated arc therapy for distal esophageal cancer. Medical Dosimetry : Official Journal of the American Association of Medical Dosimetrists. PMID 38001010 DOI: 10.1016/j.meddos.2023.09.004  0.357
2023 Mittauer KE, Tolakanahalli R, Kotecha R, Chuong MD, Mehta MP, Gutierrez AN, Bassiri N. Commissioning Intracranial Stereotactic Radiosurgery (SRS) for an MR-guided Radiotherapy (MRgRT) system: MR-RT Localization and Dosimetric End-to-End Validation. International Journal of Radiation Oncology, Biology, Physics. PMID 37793574 DOI: 10.1016/j.ijrobp.2023.08.043  0.664
2023 Kutuk T, Tolakanahalli R, Chaswal V, Yarlagadda S, Herrera R, Appel H, La Rosa A, Mishra V, Wieczorek DJJ, McDermott MW, Siomin V, Mehta MP, Odia Y, Gutierrez AN, Kotecha R. Surgically targeted radiation therapy (STaRT) for recurrent brain metastases: Initial clinical experience. Brachytherapy. PMID 37722990 DOI: 10.1016/j.brachy.2023.08.002  0.65
2023 Lee YC, Wieczorek DJ, Chaswal V, Kotecha R, Hall MD, Tom MC, Mehta MP, McDermott MW, Gutierrez AN, Tolakanahalli R. A study on inter-planner plan quality variability using a manual planning- or Lightning dose optimizer-approach for single brain lesions treated with the Gamma Knife Icon™. Journal of Applied Clinical Medical Physics. e14088. PMID 37415385 DOI: 10.1002/acm2.14088  0.678
2023 La Rosa A, Mittauer KE, Chuong MD, Hall MD, Kutuk T, Bassiri N, McCulloch J, Alvarez D, Herrera R, Gutierrez AN, Tolakanahalli R, Mehta MP, Kotecha R. Accelerated hypofractionated magnetic resonance-guided adaptive radiotherapy for oligoprogressive non-small cell lung cancer. Medical Dosimetry : Official Journal of the American Association of Medical Dosimetrists. PMID 37330328 DOI: 10.1016/j.meddos.2023.05.002  0.694
2023 La Rosa A, Mittauer KE, Rzepczynski AE, Chuong MD, Kutuk T, Bassiri N, McAllister NC, Hall MD, McCulloch J, Alvarez D, Herrera R, Gutierrez AN, Tolakanahalli R, Odia Y, Ahluwalia MS, et al. Treatment of glioblastoma using MRIdian® A3i BrainTx™: Imaging and treatment workflow demonstration. Medical Dosimetry : Official Journal of the American Association of Medical Dosimetrists. PMID 36966049 DOI: 10.1016/j.meddos.2023.02.001  0.689
2023 Tolakanahalli R, Wieczorek DJJ, Lee YC, Tom MC, Hall MD, McDermott MW, Mehta MP, Kotecha R, Gutierrez AN. OptImal Gamma kNife lIghTnIng sOlutioN (IGNITION) score to characterize the solution space of the Gamma Knife FIP optimizer for stereotactic radiosurgery. Journal of Applied Clinical Medical Physics. e13936. PMID 36855958 DOI: 10.1002/acm2.13936  0.641
2023 Lee YC, Davis SD, Romaguera W, Chaswal V, Tolakanahalli R, Gutierrez AN, Kalman NS. Implementation of superficial radiation therapy (SRT) using SRT-100 Vision™ for non-melanoma skin cancer in a Radiation Oncology clinic. Journal of Applied Clinical Medical Physics. e13926. PMID 36800309 DOI: 10.1002/acm2.13926  0.631
2023 La Rosa A, Wieczorek DJJ, Tolakanahalli R, Lee YC, Kutuk T, Tom MC, Hall MD, McDermott MW, Mehta MP, Gutierrez AN, Kotecha R. Dosimetric Impact of Lesion Number, Size, and Volume on Mean Brain Dose with Stereotactic Radiosurgery for Multiple Brain Metastases. Cancers. 15. PMID 36765738 DOI: 10.3390/cancers15030780  0.662
2022 Abraham U, Romaguera T, Tolakanahalli R, Gutierrez AN, Hall M. Fractionated Total Body Irradiation on an Infant Using Tomotherapy. Cureus. 14: e28143. PMID 36148186 DOI: 10.7759/cureus.28143  0.679
2022 Kutuk T, Kotecha R, Tolakanahalli R, Wieczorek DJJ, Lee YC, Ahluwalia MS, Hall MD, McDermott MW, Appel H, Gutierrez AN, Mehta MP, Tom MC. Zero Setup Margin Mask versus Frame Immobilization during Gamma Knife Icon™ Stereotactic Radiosurgery for Brain Metastases. Cancers. 14. PMID 35884453 DOI: 10.3390/cancers14143392  0.657
2022 Kutuk T, Tolakanahalli R, McAllister NC, Hall MD, Tom MC, Rubens M, Appel H, Gutierrez AN, Odia Y, Mohler A, Ahluwalia MS, Mehta MP, Kotecha R. Pulsed-Reduced Dose Rate (PRDR) Radiotherapy for Recurrent Primary Central Nervous System Malignancies: Dosimetric and Clinical Results. Cancers. 14. PMID 35740612 DOI: 10.3390/cancers14122946  0.638
2022 Kutuk T, Abrams KJ, Tom MC, Rubens M, Appel H, Sidani C, Hall MD, Tolakanahalli R, Wieczorek DJJ, Gutierrez AN, McDermott MW, Ahluwalia MS, Mehta MP, Kotecha R. Dedicated isotropic 3-D T1 SPACE sequence imaging for radiosurgery planning improves brain metastases detection and reduces the risk of intracranial relapse. Radiotherapy and Oncology : Journal of the European Society For Therapeutic Radiology and Oncology. 173: 84-92. PMID 35662657 DOI: 10.1016/j.radonc.2022.05.029  0.663
2022 Al-Hallaq HA, Cerviño L, Gutierrez AN, Havnen-Smith A, Higgins SA, Kügele M, Padilla L, Pawlicki T, Remmes N, Smith K, Tang X, Tomé WA. AAPM task group report 302: Surface guided radiotherapy. Medical Physics. PMID 35179229 DOI: 10.1002/mp.15532  0.471
2021 Kutuk T, Tolakanahalli R, Williams A, Tom MC, Vadhan JD, Appel H, Hall MD, Wieczorek DJJ, Davis S, McDermott MW, Ahluwalia MS, Mehta MP, Gutierrez AN, Kotecha R. Impact of MRI timing on tumor volume and anatomic displacement for brain metastases undergoing stereotactic radiosurgery. Neuro-Oncology Practice. 8: 674-683. PMID 34777836 DOI: 10.1093/nop/npab047  0.664
2021 Wieczorek DJ, Kotecha R, Hall MD, Tom MC, Davis S, Ahluwalia MS, McDermott MW, Mehta MP, Gutierrez AN, Tolakanahalli R. Systematic evaluation and plan quality assessment of the Leksell® gamma knife® lightning dose optimizer. Medical Dosimetry : Official Journal of the American Association of Medical Dosimetrists. PMID 34696931 DOI: 10.1016/j.meddos.2021.08.006  0.688
2021 McConnell K, Kirby N, Rasmussen K, Gutierrez AN, Papanikolaou N, Stanley D. Variability of Breast Surface Positioning Using an Active Breathing Coordinator for a Deep Inspiration Breath Hold Technique. Cureus. 13: e15649. PMID 34306859 DOI: 10.7759/cureus.15649  0.761
2021 Kutuk T, McCulloch J, Mittauer KE, Romaguera T, Alvarez D, Gutierrez AN, Chuong M, Kotecha R. Daily online adaptive magnetic resonance image (MRI) guided stereotactic body radiation therapy for primary renal cell cancer. Medical Dosimetry : Official Journal of the American Association of Medical Dosimetrists. PMID 33814259 DOI: 10.1016/j.meddos.2021.02.008  0.307
2020 Chuong MD, Bryant J, Mittauer KE, Hall M, Kotecha R, Alvarez D, Romaguera T, Rubens M, Adamson S, Godley A, Mishra V, Luciani G, Gutierrez AN. Ablative 5-fraction stereotactic magnetic resonance-guided radiation therapy (MRgRT) with on-table adaptive replanning and elective nodal irradiation for inoperable pancreas cancer. Practical Radiation Oncology. PMID 32947042 DOI: 10.1016/J.Prro.2020.09.005  0.366
2019 Bergamo AM, Kauweloa K, Gan G, Shi Z, Daniels J, Crownover R, Narayanasamy G, Stathakis S, Mavroidis P, Papanikolaou N, Gutierrez A. Correlation between Biological Effective Dose and Radiation-induced Liver Disease from Hypofractionated Radiotherapy. Journal of Medical Physics. 44: 185-190. PMID 31576066 DOI: 10.4103/Jmp.Jmp_54_18  0.317
2019 Kauweloa KI, Bergamo A, Gutierrez AN, Stathakis S, Papanikolaou N, Mavroidis P. Use of 3D biological effective dose (BED) for optimizing multi-target liver cancer treatments. Australasian Physical & Engineering Sciences in Medicine. PMID 31297729 DOI: 10.1007/S13246-019-00771-4  0.416
2018 McConnell KA, Marston T, Zehren BE, Lirani A, Stanley DN, Bishop A, Crownover R, Eng T, Shi Z, Li Y, Baacke D, Kirby N, Rasmussen K, Papanikolaou N, Gutierrez AN. Dosimetric Evaluation of Pinnacle's Automated Treatment Planning Software to Manually Planned Treatments. Technology in Cancer Research & Treatment. 17: 1533033818780064. PMID 29909735 DOI: 10.1177/1533033818780064  0.786
2018 Stanley DN, Rasmussen K, Kirby N, Papanikolaou N, Gutiérrez AN. An evaluation of the stability of image quality parameters of Elekta X-ray volume imager and iViewGT imaging systems. Journal of Applied Clinical Medical Physics. PMID 29520938 DOI: 10.1002/Acm2.12289  0.769
2018 Brito Delgado A, Rasmussen K, Shi Z, Pesqueira TM, Kauweloa K, Cohen D, Eng T, Kirby N, Saenz D, Stathakis S, Papanikolaou N, Gutierrez A. The Analytical Hierarchy Process (AHP) to Score Plan Quality of Intact Prostate Treatment Plans International Journal of Radiation Oncology*Biology*Physics. 102: e534. DOI: 10.1016/J.Ijrobp.2018.07.1497  0.665
2017 Stanley DN, McConnell KA, Kirby N, Gutiérrez AN, Papanikolaou N, Rasmussen K. Comparison of initial patient setup accuracy between surface imaging and three point localization: A retrospective analysis. Journal of Applied Clinical Medical Physics. PMID 28901684 DOI: 10.1002/Acm2.12183  0.774
2016 Gutierrez A, Stanley D, Papanikolaou N, Crownover R. SU-F-J-22: Lung VolumeVariability Assessed by Bh-CBCT in 3D Surface Image Guided Deep InspirationBreath Hold (DIBH) Radiotherapy for Left-Sided Breast Cancer. Medical Physics. 43: 3410-3411. PMID 28048690 DOI: 10.1118/1.4955930  0.697
2016 Stanley D, Rasmussen K, Kirby N, Papanikolaou N, Gutierrez A. SU-F-J-20: Commissioning and Acceptance Testing of the C-Rad CatalystHD Surface Imaging System. Medical Physics. 43: 3410. PMID 28048156 DOI: 10.1118/1.4955928  0.699
2016 Cline K, Obeidat M, Stathakis S, Kabat C, Markovic M, Papanikolaou N, Rasmussen K, Gutierrez A, Ha C, Lee S, Shim E, Kirby N. TU-H-CAMPUS-TeP2-04: Measurement of Stereotactic Output Factors with DNA Double-Strand Breaks. Medical Physics. 43: 3784. PMID 28047206 DOI: 10.1118/1.4957692  0.667
2016 Papanikolaou KN, Watts LT, Pappas E, Maris T, Ha C, Kirby N, Rasmussen K, Gutierrez AN, Stathakis S. SU-F-T-585: A Novel Phantom for Dosimetric Validation of SBRT for Spinal Lesions. Medical Physics. 43: 3598. PMID 28046929 DOI: 10.1118/1.4956770  0.645
2016 Rasmussen K, Baumgarten A, Stanley D, Pelletier C, Corbett M, Jung J, Feng Y, Huang Z, Ju A, Eng T, Kirby N, Gutierrez A, Stathakis S, Papanikolaou N. SU-G-201-07: Dosimetric Verification of a 3D Printed HDR Skin Brachytherapy Applicator. Medical Physics. 43: 3624. PMID 28046821 DOI: 10.1118/1.4956880  0.767
2016 Roring JE, Stanley D, Papanikolaou N, Gutierrez AN. SU-F-T-484: Initial Evaluation of a Novel 6D QA Phantom (HexaCheck) for Daily 6D Couch Correction Assessment. Medical Physics. 43: 3574. PMID 28046558 DOI: 10.1118/1.4956669  0.695
2016 Saenz D, Gutierrez A. SU-F-T-330: Characterization of the Clinically Released ScandiDos Discover Diode Array for In-Vivo Dose Monitoring. Medical Physics. 43: 3539. PMID 28046550 DOI: 10.1118/1.4956515  0.318
2016 Papanikolaou P, Watts L, Pappas E, Kalaitzakis G, Maris T, Kirby N, Rasmussen K, Gutierrez A, Stathakis S, Pappas E. SU-F-T-513: Dosimetric Validation of Spatially Fractionated Radiotherapy Using Gel Dosimetry. Medical Physics. 43: 3581. PMID 28046543 DOI: 10.1118/1.4956698  0.342
2016 Alexandrian A, Kabat C, Defoor D, Saenz D, Rasmussen K, Kirby N, Gutierrez A, Papanikolaou N, Stathakis S. SU-F-T-458: Tracking Trends of TG-142 Parameters Via Analysis of Data Recorded by 2D Chamber Array. Medical Physics. 43: 3568. PMID 28046434 DOI: 10.1118/1.4956643  0.643
2016 Delgado AB, Cohen D, Eng T, Gutierrez A. SU-F-T-590: Modeling PTV Dose Fall-Off for Cervical Cancer SBRT Treatment Planning Using VMAT and Step-And-Shoot IMRT. Medical Physics. 43: 3599. PMID 28046395 DOI: 10.1118/1.4956775  0.413
2016 Cohen D, Delgado AB, Eng TY, Gutierrez AN. Dosimetric Evaluation of Noncoplanar Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Delivery Techniques for Cervical Stereotactic Body Radiation Therapy Treatments. International Journal of Radiation Oncology, Biology, Physics. 96: E666-E667. PMID 27675304 DOI: 10.1016/J.Ijrobp.2016.06.2296  0.303
2016 Papanikolaou N, Pappas E, Watts L, Clarke G, Gutierrez AN, Kirby N, Rasmussen K, Ha CS, Stathakis S. A Pseudo-In Vivo Evaluation of Dose Delivered in Spine Stereotactic Body Radiation Therapy: Dosimetric and Clinical Implications. International Journal of Radiation Oncology, Biology, Physics. 96: E119. PMID 27673824 DOI: 10.1016/J.Ijrobp.2016.06.889  0.358
2016 Narayanasamy G, Avila G, Mavroidis P, Papanikolaou N, Gutierrez A, Baacke D, Shi Z, Stathakis S. Comparison of composite prostate radiotherapy plan doses with dependent and independent boost phases. Australasian Physical & Engineering Sciences in Medicine / Supported by the Australasian College of Physical Scientists in Medicine and the Australasian Association of Physical Sciences in Medicine. PMID 27550442 DOI: 10.1007/S13246-016-0469-3  0.403
2016 Kauweloa KI, Gutierrez AN, Stathakis S, Papanikolaou N, Mavroidis P. A graphical user interface (GUI) toolkit for the calculation of three-dimensional (3D) multi-phase biological effective dose (BED) distributions including statistical analyses. Computer Methods and Programs in Biomedicine. 131: 1-12. PMID 27265044 DOI: 10.1016/J.Cmpb.2016.03.028  0.388
2015 Stanley DN, Popp T, Ha CS, Swanson GP, Eng TY, Papanikolaou N, Gutiérrez AN. Dosimetric effect of photon beam energy on volumetric modulated arc therapy treatment plan quality due to body habitus in advanced prostate cancer. Practical Radiation Oncology. 5: e625-33. PMID 26419443 DOI: 10.1016/J.Prro.2015.06.012  0.706
2015 Stanley DN, Papanikolaou N, Gutierrez AN. An evaluation of the stability of image-quality parameters of Varian on-board imaging (OBI) and EPID imaging systems. Journal of Applied Clinical Medical Physics / American College of Medical Physics. 16: 5088. PMID 26103178 DOI: 10.1120/Jacmp.V16I2.5088  0.699
2015 Narayanasamy G, Granatowicz D, Baacke D, Li Y, Gutierrez A, Papanikolaou N, Stathakis S. A Comparison between Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, and Volumetric-Modulated Arc Therapy Techniques for Stereotactic Body Radiotherapy of Lung Tumors International Journal of Medical Physics, Clinical Engineering and Radiation Oncology. 4: 104-112. DOI: 10.4236/Ijmpcero.2015.42014  0.43
2015 Quino LAV, Hernandez CI, Papanikolaou N, Gutierrez A, Esquivel C, Eng T, Manciu M, Stathakis S. A Monte Carlo model for independent dose verification in IMRT and VMAT for the Varian Novalis TX with high definition MLC International Journal of Cancer Therapy and Oncology. 3: 3312. DOI: 10.14319/Ijcto.33.12  0.419
2015 Papanikolaou N, Narayanasamy G, Stathakis S, Pappas E, Kirby N, Mavroidis P, Crownover R, Gutierrez A. SU‐E‐T‐85: A Systematic Analysis of Mono‐Isocentric Techniques for the Treatment of Multiple Metastasis Medical Physics. 42: 3350-3350. DOI: 10.1118/1.4924446  0.448
2015 Pappas E, Papanikolaou N, Gutierrez A, Kirby N, Mavroidis P, Efstathopoulos E, Makris D, Crownover R, Stathakis S. SU‐E‐T‐80: A Study of the Effect of Dose Grid Resolution On Stereotactic Plan Evaluation as a Function of Target Size Medical Physics. 42: 3349-3349. DOI: 10.1118/1.4924441  0.418
2015 Kauweloa K, Bergamo A, Gutierrez A, Stathakis S, Mavroidis P, Papanikolaou N, Kirby N. SU‐E‐J‐116: Uncertainties Associated with Dose Summation of High‐Dose Rate Brachytherapy and Intensity Modulated Radiotherapy for Gynecological Cases Medical Physics. 42: 3291-3291. DOI: 10.1118/1.4924203  0.409
2015 Stanley D, Kirby N, Papanikolaou N, Gutierrez A. SU‐E‐J‐82: Evaluation of the Spatial Reproducibility and Temporal Drift of the CRAD CatalystHD System Medical Physics. 42: 3282-3283. DOI: 10.1118/1.4924169  0.681
2015 Stanley D, Papanikolaou N, Gutierrez A. SU-E-J-50: An Evaluation of the Stability of Image Quality Parameters of the Elekta XVI and IView Imaging Systems Medical Physics. 42: 3275-3275. DOI: 10.1118/1.4924137  0.7
2015 Bergamo A, Kauweloa K, Daniels J, Crownover R, Mavroidis P, Papanikolaou N, Gutierrez A. SU‐E‐P‐52: Dose‐Volume Toxicity Analysis of Stereotactic Body Radiation Therapy for Hepatocellular Carcinoma Medical Physics. 42: 3238-3238. DOI: 10.1118/1.4923986  0.358
2015 Kauweloa K, Gutierrez A, Stathakis S, Papanikolaou N, Mavroidis P. SU-E-P-06: A Graphical User Interface (GUI) Toolkit Created for Multi-Phase Biological Effective Dose (BED) Calculations Including Statistical Analyses Medical Physics. 42: 3227-3227. DOI: 10.1118/1.4923940  0.398
2015 Cline K, Stanley D, Defoor D, Stathakis S, Gutierrez A, Papanikolaou N, Kirby N. SU‐E‐E‐02: An Excel‐Based Study Tool for ABR‐Style Exams Medical Physics. 42: 3223-3223. DOI: 10.1118/1.4923924  0.659
2015 Kauweloa K, Bergamo A, Gutierrez AN, Stathakis S, Papanikolaou N, Mavroidis P. Use of the 3-D Biological Effective Dose (BED) for Optimizing Liver Cancer SBRT Treatments International Journal of Radiation Oncology Biology Physics. 93. DOI: 10.1016/J.Ijrobp.2015.07.2030  0.332
2015 Stanley D, Popp T, Ha C, Swanson G, Eng T, Papanikolaou N, Gutierrez A. Dosimetric Effect of Photon Beam Energy on VMAT Treatment Plan Quality Due to Body Habitus for Advanced Prostate Cancer International Journal of Radiation Oncology*Biology*Physics. 93: E565. DOI: 10.1016/J.Ijrobp.2015.07.1993  0.677
2014 Stanley DN, Papanikolaou N, Gutierrez AN. Development of image quality assurance measures of the ExacTrac localization system using commercially available image evaluation software and hardware for image-guided radiotherapy. Journal of Applied Clinical Medical Physics. 15: 81-91. PMID 28297269 DOI: 10.1120/jacmp.v15i6.4877  0.679
2014 Kauweloa K, Gutierrez A, Bergamo A, Stathakis S, Papanikolaou N, Mavroidis P. SU-E-T-490: Clinical Analysis of the Approximate Multi-Phase Biological Effective Dose (BED) Calculation. Medical Physics. 41: 339. PMID 28038276 DOI: 10.1118/1.4888823  0.332
2014 Stanley D, Papanikolaou N, Gutierrez A. SU-E-J-24: An Evaluation of the Stability of Image Quality Parameters of Varian On-Board Imaging (OBI) and EPID Imaging Systems. Medical Physics. 41: 160. PMID 28038273 DOI: 10.1118/1.4888075  0.694
2014 Kauweloa K, Gutierrez A, Bergamo A, Stathakis S, Papanikolaou N, Mavroidis P. SU-E-T-510: Mathematical Analysis of Approximate Biological Effective Dose (BED) Calculation for Multi-Phase Radiotherapy Treatment Plans. Medical Physics. 41: 344. PMID 28037329 DOI: 10.1118/1.4888843  0.372
2014 Narayanasamy G, Cruz W, Breton C, Gutierrez A, Mavroidis P, Papanikolaou N, Stathakis S. SU-E-T-499: Comparison of Measured Tissue Phantom Ratios (TPR) Against Calculated From Percent Depth Doses (PDD) with and Without Peak Scatter Factor (PSF) in 6MV Open Beam. Medical Physics. 41: 341. PMID 28037309 DOI: 10.1118/1.4888832  0.321
2014 Papanikolaou P, Tuohy R, Mavroidis P, Eng T, Gutierrez A, Stathakis S. SU-E-J-27: Appropriateness Criteria for Deformable Image Registration and Dose Propagation. Medical Physics. 41: 160. PMID 28036904 DOI: 10.1118/1.4888078  0.389
2014 Stanley DN, Papanikolaou N, Gutiérrez AN. Development of image quality assurance measures of the ExacTrac localization system using commercially available image evaluation software and hardware for image-guided radiotherapy. Journal of Applied Clinical Medical Physics / American College of Medical Physics. 15: 4877. PMID 25493511 DOI: 10.1120/Jacmp.V15I6.4877  0.679
2014 Kauweloa KI, Gutierrez AN, Bergamo A, Stathakis S, Papanikolaou N, Mavroidis P. Practical aspects and uncertainty analysis of biological effective dose (BED) regarding its three-dimensional calculation in multiphase radiotherapy treatment plans. Medical Physics. 41: 071707. PMID 24989376 DOI: 10.1118/1.4883775  0.409
2014 Vazquez Quino LA, Chen X, Fitzpatrick M, Shi C, Stathakis S, Gutierrez A, Esquivel C, Mavroidis P, Alkhatib H, Papanikolaou N. Patient specific pre-treatment QA verification using an EPID approach. Technology in Cancer Research & Treatment. 13: 1-10. PMID 23819492 DOI: 10.7785/Tcrt.2012.500351  0.467
2014 Stanley DN, Narayanasamy G, Breton C, Papanikolaou N, Gutierrez AN. Comparison of low contrast sensitivity among multi-slice CT units using various mAs setting for the potential benefit of non-MRI compatible, stereotactic radiosurgery (SRS) patients International Journal of Cancer Therapy and Oncology. 2: 20237. DOI: 10.14319/Ijcto.0202.37  0.691
2014 Kauweloa KI, Gutierrez AN, Bergamo A, Stathakis S, Papanikolaou N, Mavroidis P. Mathematical analysis of approximate biological effective dose (BED) calculation for multi-phase radiotherapy treatment plans International Journal of Cancer Therapy and Oncology. 2: 20226. DOI: 10.14319/Ijcto.0202.26  0.379
2014 Defoor DL, Mavroidis P, Quino LV, Gutierrez A, Papanikolaou N, Stathakis S. On the evaluation of patient specific IMRT QA using EPID, dynalog files and patient anatomy International Journal of Cancer Therapy and Oncology. 2: 20219. DOI: 10.14319/Ijcto.0202.19  0.434
2014 Bosse C, Tuohy R, Mavroidis P, Shi Z, Crownover R, Gutierrez A, Papanikolaou N, Stathakis S. Daily fraction dose recalculation based on rigid registration using Cone Beam CT International Journal of Cancer Therapy and Oncology. 2: 020217. DOI: 10.14319/Ijcto.0202.17  0.428
2014 Defoor D, Mavroidis P, Gutierrez A, Papanikolaou N, Stathakis S. On the Evaluation of Patient-Specific IMRT QA Using EPID, Dynalog Files, and Patient Anatomy International Journal of Radiation Oncology Biology Physics. 90. DOI: 10.1016/J.Ijrobp.2014.05.2524  0.412
2014 Tuohy R, Bosse C, Mavroidis P, Zheng S, Richard C, Gutierrez A, Papanikolaou N, Stathakis S. Strategies for Evaluation of Daily Delivered Dose Using Cone Beam CT (CBCT) International Journal of Radiation Oncology Biology Physics. 90. DOI: 10.1016/J.Ijrobp.2014.05.2517  0.344
2013 Markovic M, Stathakis S, Ha C, Poppe B, Gutierrez A, Papanikolaou N. SU-E-T-323: Characterization of the Two-Dimensional Liquid Field Ion Chamber Detector Array Used for the Verification of the Treatments in Radiation Therapy. Medical Physics. 40: 278. PMID 28518594 DOI: 10.1118/1.4814757  0.338
2013 Myers P, Stathakis S, Mavroidis P, Gutierrez A, Esquivel C, Jones W, Eng T, Ha C, Papanikolaou N. SU-E-T-308: Radiobiological Evaluation of the Three Dimensional Conformal Radiation Therapy, SmartArc, and Helical Tomotherapy Treatment Techniques for Pediatric Cranio-Spinal Axis Irradiation. Medical Physics. 40: 275. PMID 28518586 DOI: 10.1118/1.4814742  0.358
2013 Myers P, Stathakis S, Mavroidis P, Esquivel C, Gutierrez A, Jones W, Eng T, Ha C, Papanikolaou N. SU-E-T-281: Pediatric Cranio-Spinal Axis Irradiation: Comparison of Radiation-Induced Secondary Malignancy Estimations Based On Three Methods of Analysis for Three Different Treatment Techniques. Medical Physics. 40: 268-269. PMID 28518560 DOI: 10.1118/1.4814715  0.303
2013 Esquivel C, Stathakis S, Eng T, Patel A, Gutierrez A, Mavroidis P, Papanikolaou N. SU-E-T-346: Dosimetric Evaluation of a High-Dose-Rate Modified-Rotte "Y" Applicator for Treatment of Inoperable Endometrial Cancer. Medical Physics. 40: 284. PMID 28517738 DOI: 10.1118/1.4814780  0.324
2013 Myers P, Stathakis S, Gutiérrez AN, Esquivel C, Mavroidis P, Papanikolaou N. Dosimetric Comparison of Craniospinal Axis Irradiation (CSI) Treatments Using Helical Tomotherapy, Smartarc TM , and 3D Conventional Radiation Therapy * International Journal of Medical Physics, Clinical Engineering and Radiation Oncology. 2: 30-38. DOI: 10.4236/Ijmpcero.2013.21005  0.442
2013 Stanley D, Papanikolaou N, Gutierrez A. SU‐E‐T‐123: Development of a Methodology to Assess the Image Quality of the ExacTracTM Localization System Using the PIPSproTM Software and Unfors RaySafe Xi R/F Detector Medical Physics. 40: 232-232. DOI: 10.1118/1.4814558  0.69
2012 Quino lV, Stathakis S, Gutierrez A, Esquivel C, Alkhatib H, Papanikolaou N. WE-G-BRB-02: MU-EPID an EPID Based Tool for IMRT Quality Assurance. Medical Physics. 39: 3967-3967. PMID 28519645 DOI: 10.1118/1.4736188  0.471
2012 Esquivel C, Stathakis S, Gutierrez A, Papanikolaou N. SU-E-T-517: Characterization of Relative Doses and Source Strengths for Various Plaque Sizes and Tumor Dimensions in the Treatment of Uveal Melanoma. Medical Physics. 39: 3824-3824. PMID 28518503 DOI: 10.1118/1.4735606  0.373
2012 McKinsey R, Stathakis S, Esquivel C, Gutierrez A, Myers P, Nayebi N, Regan M, Papanikolaou N. SU-E-T-387: Validation of a New System for Patient Specific IMRT QA and Comparison with Other Commerical Systems. Medical Physics. 39: 3793. PMID 28517189 DOI: 10.1118/1.4735476  0.306
2012 Markovic M, Stathakis S, Mavroidis P, Gutierrez A, Esquivel C, Papanikolau N. SU-E-T-601: Dosimetric Evaluation of the Parameter Variation with Varying Calculation Grid Size in the IMRT Cases. Medical Physics. 39: 3844-3844. PMID 28517093 DOI: 10.1118/1.4735690  0.417
2012 Calvo OI, Gutiérrez AN, Stathakis S, Esquivel C, Papanikolaou N. On the quantification of the dosimetric accuracy of collapsed cone convolution superposition (CCCS) algorithm for small lung volumes using IMRT. Journal of Applied Clinical Medical Physics / American College of Medical Physics. 13: 3751. PMID 22584174 DOI: 10.1120/Jacmp.V13I3.3751  0.417
2012 Myers P, Stathakis S, Gutiérrez AN, Esquivel C, Mavroidis P, Papanikolaou N. Evaluation of PTW Seven29 for tomotherapy patient-specific quality assurance and comparison with ScandiDos Delta(4). Journal of Medical Physics / Association of Medical Physicists of India. 37: 72-80. PMID 22557796 DOI: 10.4103/0971-6203.94741  0.396
2012 Calvo O, Stathakis S, Gutiérrez AN, Esquivel C, Papanikolaou N. 3D dose reconstruction of pretreatment verification plans using multiple 2D planes from the OCTAVIUS/Seven29 phantom array Technology in Cancer Research and Treatment. 11: 69-82. PMID 22181333 DOI: 10.7785/Tcrt.2012.500236  0.438
2012 Stathakis S, Esquivel C, Quino LV, Myers P, Calvo O, Mavroidis P, Gutiérrez AN, Papanikolaou N. Accuracy of the Small Field Dosimetry Using the Acuros XB Dose Calculation Algorithm within and beyond Heterogeneous Media for 6 MV Photon Beams International Journal of Medical Physics, Clinical Engineering and Radiation Oncology. 1: 78-87. DOI: 10.4236/Ijmpcero.2012.13011  0.347
2012 Papanikolaou N, Quino LV, Stathakis S, Gutierrez A, Esquivel C, Alkhatib H. SU‐E‐T‐379: Assessment of the Dosimetric Significance of Isocenter Shift by Means of EPIDQA Medical Physics. 39: 3791-3791. DOI: 10.1118/1.4735466  0.421
2012 Quino lV, Stathakis S, Gutierrez A, Esquivel C, Papanikolaou N. SU‐E‐T‐365: IMRT Monte Carlo Dose Calculations for a Novalis TX LINAC Equipped with HD‐120 MLC Medical Physics. 39: 3788-3788. DOI: 10.1118/1.4735452  0.405
2012 Stathakis S, Myers P, Esquivel C, Gutierrez A, Mavroidis P, Papanikolaou N. SU‐E‐T‐361: Evaluation of a New Commercially Device for Patient Specific IMRT QA Medical Physics. 39: 3787-3787. DOI: 10.1118/1.4735448  0.433
2012 Kim S, Stathakis S, Esquivel C, Papanikolaou N, Gutierrez A. SU-E-T-354: Comparative Evaluation of EBT2 Film, Matrixx and PTW729 for Patient Specific, Small-Field, High Dose IMRT Plans Medical Physics. 39: 3785-3785. DOI: 10.1118/1.4735441  0.369
2012 Regan M, Stathakis S, Nayebi N, Mckinsey R, Myers P, Knaup C, Quino lV, Gutierrez A, Esquivel C, Mavroidis P, Papanikolaou N. SU‐E‐T‐350: Three Year Analysis Using Ionization Chamber Array for Patient Specific IMRT QA Medical Physics. 39: 3784-3784. DOI: 10.1118/1.4735437  0.412
2011 Gutiérrez AN, Stathakis S, Crownover R, Esquivel C, Shi C, Papanikolaou N. Clinical evaluation of an immbolization system for stereotactic body radiotherapy using helical tomotherapy. Medical Dosimetry : Official Journal of the American Association of Medical Dosimetrists. 36: 126-9. PMID 20435464 DOI: 10.1016/J.Meddos.2010.02.003  0.371
2011 Calvo O, Kim S, Lei Y, Gutierrez A, Stathakis S, Papanikolaou N. WE‐E‐BRB‐10: Can 2D and 3D Detector Arrays Identify Multileaf Collimator (MLC) Positional Errors during Smart‐Arc Pre‐Treatment Verification Plan Delivery? Medical Physics. 38: 3818-3818. DOI: 10.1118/1.3613377  0.347
2011 Biggers T, Esquivel C, Stathakis S, Gutiérrez A, Papanikolaou N. WE-A-BRB-11: Evaluation of Cervical Cancer Radiation Therapy Using External Beam Therapy and Brachytherapy Medical Physics. 38: 3794-3794. DOI: 10.1118/1.3613278  0.449
2011 Esquivel C, Stathakis S, Sath C, Gutiérrez A, Dorward J, Mihailidis D, Mavroidis P, Papanikolaou N. SU‐E‐T‐707: Clinical Evaluation of a New Commercial Dose Calculation Algorithm Medical Physics. 38: 3653-3653. DOI: 10.1118/1.3612669  0.366
2011 Stathakis S, Esquivel C, Gutierrez A, Mihailidis D, Buckey C, Myers P, Mavroidis P, Papanikolaou N. SU‐E‐T‐702: Accuracy of a Commercially Available Dose Calculation Algorithm for Small Field Dosimetry Medical Physics. 38: 3651-3652. DOI: 10.1118/1.3612664  0.328
2011 Nayebi N, Gutierrez A, Papanikolaou N. SU‐E‐T‐498: Comparison of Inter‐Fraction Setup Uncertainty of Two Commercially‐ Available, Cranial Immobilization Masks Using KV‐CBCT and ExacTrac® Imaging Systems Medical Physics. 38: 3603-3603. DOI: 10.1118/1.3612451  0.342
2011 Buckey C, Myers P, Esquivel C, Mihailidis D, Mavroidis P, Gutiérrez A, Papanikolaou N, Stathakis S. SU-E-T-155: Evaluation of An in Vivo Device for Daily Patient Treatment Delivery Measurements Using a Varian Linear Accelerator Medical Physics. 38: 3521-3522. DOI: 10.1118/1.3612105  0.4
2011 Buckey C, Myers P, Mavroidis P, Esquivel C, Mihailidis D, Gutiérrez A, Papanikolaou N, Stathakis S. SU‐E‐T‐151: Application of a 2D Ionization Chamber Array for Monthly and Annual Linear Accelerator QA Medical Physics. 38: 3521-3521. DOI: 10.1118/1.3612102  0.325
2011 Myers P, Buckey C, Mihailidis D, Mavroidis P, Esquivel C, Gutiérrez A, Papanikolaou N, Stathakis S. SU‐E‐T‐91: VMAT Monthly Quality Assurance Using an in Vivo Dosimetric Device Attached to the Linac Gantry Medical Physics. 38: 3506-3506. DOI: 10.1118/1.3612042  0.387
2011 Zalman T, Stathakis S, Esquivel C, Gutierrez A, Mihailidis D, Mavroidis P, Papanikolaou N. SU‐E‐T‐73: Investigation of Dose Reconstruction Using the Dosimetry Check Platform for Different Anatomical Sites Medical Physics. 38: 3502-3502. DOI: 10.1118/1.3612024  0.431
2011 Zalman T, Stathakis S, Esquivel C, Gutierrez A, Mihailidis D, Mavroidis P, Papanikolaou N. SU‐E‐T‐61: IMRT Patient QA with Dosimetry Check: The Effect of Detector Selection in Volumetric Dose Reconstruction Medical Physics. 38: 3499-3499. DOI: 10.1118/1.3612012  0.449
2011 Gutierrez A, Stathakis S, Crownover RL, Esquivel C, Papanikolaou N. SU‐E‐J‐132: Inter‐Fractional Setup Accuracy of the Body Pro‐Lok™ System for Hypo‐Fractionated Liver Radiotherapy Using Novalis Tx™ Medical Physics. 38: 3473-3473. DOI: 10.1118/1.3611899  0.351
2011 Esquivel C, Zalman T, Fitzpatrick M, Vazquez‐quino L, Gutiérrez A, Papanikolaou N, Stathakis S. SU‐D‐214‐04: Accuracy of the Dose Calculation Algorithm of a Commercially Availale Fluence Based IMRT QA Software Medical Physics. 38: 3386-3386. DOI: 10.1118/1.3611534  0.437
2010 Buckey C, Stathakis S, Cashon K, Gutierrez A, Esquivel C, Shi C, Papanikolaou N. Evaluation of a commercially-available block for spatially fractionated radiation therapy Journal of Applied Clinical Medical Physics / American College of Medical Physics. 11: 3163. PMID 20717082 DOI: 10.1120/Jacmp.V11I3.3163  0.39
2010 Deveau MA, Gutiérrez AN, Mackie TR, Tomé WA, Forrest LJ. Dosimetric impact of daily setup variations during treatment of canine nasal tumors using intensity-modulated radiation therapy. Veterinary Radiology & Ultrasound : the Official Journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association. 51: 90-6. PMID 20166402 DOI: 10.1111/J.1740-8261.2009.01629.X  0.596
2010 Papanikolaou N, He W, Luis AVQ, Gutierrez A, Stathakis S, Alkhatib H, Shi C. MU-Tomo: Independent dose validation software for helical tomotherapy Journal of Cancer Science & Therapy. 2: 145-152. DOI: 10.4172/1948-5956.1000040  0.422
2010 Gutiérrez AN, Tomé WA, Ghia A, Thomas S, Cannon G, Khuntia D, Kuo JS, Mehta M. Simultaneously integrated boost to multiple brain metastases during whole brain radiation therapy-hippocampal avoidance Radiosurgery. 7: 247-257. DOI: 10.1159/000288736  0.419
2010 He W, Shi C, Quino LV, Dzintars E, Gutiérrez A, Stathakis S, Alkhatib H, Papanikolaou N. MO‐EE‐A3‐04: Development and Dosimetric Studies of Independent Dose Validation Software on Helical Tomotherapy Medical Physics. 37: 3350-3350. DOI: 10.1118/1.3469094  0.414
2010 Papanikolaou N, Stathakis S, Holmes R, Gutiérrez A, Esquivel C, Shi C, Mavroidis P, Mihailidis D. SU‐GG‐T‐567: Comparison of Two Different Implementations for Volumetric Modulated Arc Therapy Medical Physics. 37: 3317-3318. DOI: 10.1118/1.3468965  0.425
2010 Gutiérrez A, Dick D, Stathakis S, Papanikolaou N. SU‐GG‐T‐564: Secondary Cancer Risk Characterization of Pediatric Craniospinal Irradiation (CSI) Using Helical Tomotherapy and Conventional 3‐Field Technique Medical Physics. 37: 3317-3317. DOI: 10.1118/1.3468962  0.401
2010 Stathakis S, Papanikolaou N, Buckey C, Mavroidis P, Mihailidis D, Shi C, Gutiérrez A, Esquivel C. SU‐GG‐T‐561: The Effect of MLC Leaf Width in RapidArc Plan Optimization Medical Physics. 37: 3316-3316. DOI: 10.1118/1.3468959  0.403
2010 Quino LV, Stathakis S, Gutiérrez A, Shi C, Papanikolaou N. SU‐GG‐T‐435: Novalis Tx MonteCarlo Based Linear Accelerator Medical Physics. 37: 3286-3286. DOI: 10.1118/1.3468832  0.378
2010 Stathakis S, Mihailidis D, Esquivel C, Gutiérrez A, Mavroidis P, Shi C, Papanikolaou N. SU‐GG‐T‐398: Monte Carlo Commissioning of BrainLab SRS Cones on a NovalisTX Medical Physics. 37: 3278-3278. DOI: 10.1118/1.3468795  0.332
2010 Gutiérrez A, Calvo O, Stathakis S, Papanikolaou N. SU‐GG‐T‐342: Dosimetric Evaluation and Characterization of a MicroLion Liquid Ionization Chamber Medical Physics. 37: 3264-3265. DOI: 10.1118/1.3468739  0.353
2010 Myers P, Stathakis S, Gutiérrez A, Mavroidis P, Mihailidis D, Papanikolaou N. SU‐GG‐T‐308: Commissioning of PTW Seven29 for Helical TomoTherapy Quality Assurance Medical Physics. 37: 3256-3256. DOI: 10.1118/1.3468704  0.42
2010 Myers P, Stathakis S, Gutiérrez A, Mavroidis P, Mihailidis D, Papanikolaou N. SU‐GG‐T‐292: Comparison of Helical TomoTherapy Patient Quality Assurance Using PTW Seven29 and ScandiDos Delta4 Medical Physics. 37: 3253-3253. DOI: 10.1118/1.3468686  0.398
2010 Calvo O, Guo B, Stathakis S, Gutiérrez A, Papanikolaou N. SU‐GG‐T‐250: 3D Dose Reconstruction for Delivery Quality Assurance (DQA) from Multiple 2D Planes Using the OCTAVIOUS Phantom Medical Physics. 37: 3243-3243. DOI: 10.1118/1.3468642  0.431
2009 Roland T, Mavroidis P, Gutierrez A, Goytia V, Papanikolaou N. A radiobiological analysis of the effect of 3D versus 4D image-based planning in lung cancer radiotherapy Physics in Medicine and Biology. 54: 5509-5523. PMID 19717886 DOI: 10.1088/0031-9155/54/18/011  0.433
2009 Mavroidis P, Stathakis S, Gutierrez A, Esquivel C, Shi C, Papanikolaou N. Expected clinical impact of the differences between planned and delivered dose distributions in helical tomotherapy for treating head and neck cancer using helical megavoltage CT images. Journal of Applied Clinical Medical Physics. 10: 2969. PMID 19692977 DOI: 10.1120/Jacmp.V10I3.2969  0.477
2009 Stathakis S, Esquivel C, Gutiérrez AN, Shi C, Papanikolaou N. Dosimetric evaluation of multi-pattern spatially fractionated radiation therapy using a multi-leaf collimator and collapsed cone convolution superposition dose calculation algorithm. Applied Radiation and Isotopes : Including Data, Instrumentation and Methods For Use in Agriculture, Industry and Medicine. 67: 1939-44. PMID 19632125 DOI: 10.1016/J.Apradiso.2009.06.012  0.342
2009 Stathakis S, Esquivel C, Gutierrez AN, Buckey CR, Papanikolaou N. Treatment planning and delivery of IMRT using 6 and 18 MV photon beams without flattening filter Applied Radiation and Isotopes. 67: 1629-1637. PMID 19369083 DOI: 10.1016/J.Apradiso.2009.03.014  0.384
2009 Tynan P, Joyner M, Smith M, Gutiérrez A, Stathakis S, Mavroidis P, Papanikolaou N, Swanson GP. MO‐EE‐A3‐06: Comparison of Pre‐ and Post‐Implant Prostate Volume Segmentation Using Trans‐Rectal Ultrasound and Computed Tomography Medical Physics. 36: 2705-2705. DOI: 10.1118/1.3182264  0.301
2009 Vazquez L, Gutiérrez A, Stathakis S, Roland T, Esquivel C, Shi C, Mavroidis P, Papanikolaou N. SU‐FF‐T‐623: Dosimetric Comparison Among 3D Conformal, IMRT, and Phase‐Average Compensators for SBRT Treatment Planning Medical Physics. 36: 2668-2668. DOI: 10.1118/1.3182121  0.4
2009 Gutiérrez A, Chotaliya H, Stathakis S, Esquivel C, Papanikolaou N. SU‐FF‐T‐597: Dosimetric Characterization of Whole Brain Radiotherapy (WBRT) Using Helical Tomotherapy Medical Physics. 36: 2662-2662. DOI: 10.1118/1.3182095  0.417
2009 Myers P, Weber L, Gutiérrez A, Papanikolaou N. SU‐FF‐T‐582: Delivery Angle Dependency On Treatment Plan Quality for Whole Breast Radiotherapy Using Helical Tomotherapy Medical Physics. 36: 2658-2658. DOI: 10.1118/1.3182080  0.404
2009 Dzintars E, Mavroidis P, Stathakis S, Shi C, Gutierrez A, Esquivel C, Su F, Papanikolaou N. SU‐FF‐T‐526: Radiobiological Evaluation of Inhomogenity Corrections in Tissue for Lung Cancer Patients Medical Physics. 36: 2645-2645. DOI: 10.1118/1.3182024  0.435
2009 Rodriguez S, Su F, Shi C, Stathakis S, Gutiérrez A, Esquivel C, Mavroidis P, Papanikolaou N. SU-FF-T-510: Comparison of Helical Tomotherapy, MLC-Based IMRT, and 3D-Conformal Radiation Modalities in BEUD Utilization and Analysis Medical Physics. 36: 2641-2641. DOI: 10.1118/1.3182008  0.394
2009 Corona I, Esquivel C, Gutiérrez A, Stathakis S, Shi C, Papanikolaou N. SU‐FF‐T‐461: Dosimetric Evaluation of a 120‐MLC Plan Delivered On a 80‐MLC Linear Accelerator Medical Physics. 36: 2629-2629. DOI: 10.1118/1.3181943  0.427
2009 Calvo O, Gutiérrez A, Stathakis S, Mavroidis P, Moral S, Esquivel C, Shi C, Papanikolaou N. SU‐FF‐T‐386: Validation of the Delta4 Dosimetry Phantom Against Ionometric Measurements Medical Physics. 36: 2610-2610. DOI: 10.1118/1.3181867  0.415
2009 Gutiérrez A, Calvo O, Stathakis S, Papanikolaou N. SU‐FF‐T‐358: Evaluation of the Delta4 ™ 3D Cylindrical Phantom for Delivery Quality Assurance of Stereotactic Body Radiotherapy (SBRT) Treatments Using Helical Tomotherapy Medical Physics. 36: 2604-2604. DOI: 10.1118/1.3181839  0.461
2009 Calvo O, Stathakis S, Gutiérrez A, Mavroidis P, Moral S, Esquivel C, Shi C, Papanikolaou N. SU‐FF‐T‐352: Characterization of Small Volume Ion Chambers for Absolute Dosimetry Medical Physics. 36: 2602-2602. DOI: 10.1118/1.3181833  0.355
2009 Esquivel C, Smith M, Stathakis S, Gutierrez A, Shi C, Papanikolaou N. SU-FF-T-267: Total Skin Electron Therapy Skin Dose Validation Using Optically Stimulated Luminescent Dosimeters Medical Physics. 36: 2582-2582. DOI: 10.1118/1.3181744  0.362
2009 Esquivel C, Smith M, Stathakis S, Gutiérrez A, Shi C, Papanikolaou N. SU‐FF‐T‐260: In Vivo Dose Measurements for Total Body Irradiation Using Optically Stimulated Luminescent Dosimeters Medical Physics. 36: 2580-2580. DOI: 10.1118/1.3181737  0.353
2009 Shi C, Gutiérrez A, Liu Y, Zhai Y, Papanikolaou N. SU-FF-T-250: Impact of Pulse Forming Network (PFN) and Injection Current (IC) Parameters On Output and Energy Variations of Helical TomoTherapy Medical Physics. 36: 2578-2578. DOI: 10.1118/1.3181726  0.316
2009 Holmes R, He W, Gutiérrez A, Shi C, Papanikolaou N. SU‐FF‐T‐242: Evaluation of Tomo Quality Assurance™ (TQA™) Performance for Daily Quality Assurance Medical Physics. 36: 2576-2576. DOI: 10.1118/1.3181718  0.315
2009 Moral S, Calvo O, Armas J, Gutiérrez A, Stathakis S, Roland T, Esquivel C, Shi C, Papanikolaou N. SU‐FF‐T‐217: Assessing the Sensitivity of a Multi‐Detector Array for IMRT Patient QA Medical Physics. 36: 2570-2570. DOI: 10.1118/1.3181692  0.425
2009 Buckey C, Stathakis S, Gutiérrez A, Esquivel C, Mavroidis P, Mihailidis D, Papanikolaou N. SU‐FF‐T‐140: The Inter‐ and Intra‐Fraction Reproducibility of Three Common IMRT Delivery Techniques Medical Physics. 36: 2552-2552. DOI: 10.1118/1.3181614  0.416
2009 Xu J, Buckey C, Swanson G, Stathakis S, Esquivel C, Gutiérrez A, Shi C, Mavroidis P, Papanikolaou N. SU-FF-T-99: Impact of Proper Bladder and Rectum Delineation in the Evaluation of the Effectiveness of IMRT in Prostate Cancer Radiotherapy Medical Physics. 36: 2542-2542. DOI: 10.1118/1.3181573  0.407
2009 Stathakis S, Buckey C, Gutiérrez A, Mavroidis P, Esquivel C, Shi C, Mihailidis D, Papanikolaou N. SU‐EE‐A1‐05: Dosimetric Evalualtion of a Commercial Compensator for Spatially Fractionated Radiation Therapy Medical Physics. 36: 2428-2428. DOI: 10.1118/1.3181097  0.35
2009 Rodriguez S, Su F, Mavroidis P, Gutierrez A, Stathakis S, Esquivel C, Shi C, Papanikolaou N. BEUD/SECONDARY MALIGNANCY ANALYSIS: COMPARISON OF HT, MLC-BASED IMRT, AND CRT IN PROSTATE TREATMENT PLANNING Radiotherapy and Oncology. 92: S238. DOI: 10.1016/S0167-8140(12)73230-9  0.447
2009 Roland T, Mavroidis P, Stathakis S, Gutierrez A, Papanikolaou N. ANALYSIS OF 4D TUMOR TRACKING RADIOTHERAPY FOR MOBILE TARGETS USING RADIOBIOLOGICAL ASSESSMENT Radiotherapy and Oncology. 92: S238. DOI: 10.1016/S0167-8140(12)73229-2  0.438
2009 Holmes R, Shi C, Esquivel C, Gutierrez A, Stathakis S, He W, Papanikolaou N. Smartarc™ Imrt Delivery: Influence Of Arc Angle And Dose Rate Radiotherapy and Oncology. 92. DOI: 10.1016/S0167-8140(12)73170-5  0.336
2008 Murphy S, Gutiérrez A, Lawrence J, Bjorling D, Mackie T, Forrest L. Laparoscopically implanted tissue expander radiotherapy in canine transitional cell carcinoma. Veterinary Radiology & Ultrasound : the Official Journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association. 49: 400-5. PMID 18720776 DOI: 10.1111/J.1740-8261.2008.00389.X  0.36
2008 Gutiérrez A, Tome W, Stathakis S, Papanikolaou N. WE-D-351-08: Integrated Subvolume Boosting Technique to Reduce Normal Tissue Irradiation During SBRT Treatment Planning Using Helical Tomotherapy Medical Physics. 35: 2947-2947. DOI: 10.1118/1.2962752  0.582
2008 Rassiah P, Szegedi M, Peyton J, Stathakis S, Esquivel C, Gutiérrez A, Papanikolaou N. WE‐C‐AUD C‐08: Accuracy of the Finite Size Pencil Beam Without the Flattening Filter Medical Physics. 35: 2937-2937. DOI: 10.1118/1.2962705  0.43
2008 Stathakis S, Gutiérrez A, Mavroidis P, Papanikolaou N. TU‐C‐AUD B‐02: Dosimetric Verification of the CCCS Algorithm for Spatially Fractionated Radiation Therapy Medical Physics. 35: 2888-2888. DOI: 10.1118/1.2962438  0.34
2008 Yam M, Gutiérrez A, Shi C, Papanikolaou N. SU‐GG‐T‐469: On the Dosimetric Characterization of Inclined Target Geometries Using Helical Tomotherapy Medical Physics. 35: 2833-2833. DOI: 10.1118/1.2962217  0.382
2008 Giantsoudi D, Gutiérrez A, Shi C, Papanikolaou N. SU-GG-T-467: On the Sensitivity of Film-Based, In Vivo Dosimetry to Setup Errors for Stereotactic Body Radiotherapy Treatments Medical Physics. 35: 2832-2832. DOI: 10.1118/1.2962215  0.446
2008 Caldwell K, Gutiérrez A, Papanikolaou N, Tome W. SU-GG-T-440: Dosimetric Delivery Verification of Whole Brain Radiotherapy with Hippocampal Avoidance (WBRT-HA) and Simultaneously Integrated Multiple Metastases Boost (SIB) Medical Physics. 35: 2826-2826. DOI: 10.1118/1.2962188  0.599
2008 Esquivel C, Mavroidis P, Shi C, Ferreira B, Lind B, Gutiérrez A, Stathakis S, Papanikolaou N. SU-GG-T-423: Radiobiological Comparison of Helical Tomotherapy and MLC-Based IMRT for Brain and Cranio-Spinal Tumors Medical Physics. 35: 2822-2822. DOI: 10.1118/1.2962171  0.405
2008 Delichas M, Ferreira B, Shi C, Gutiérrez A, Lind B, Papanikolaou N, Mavroidis P. SU-GG-T-422: Radiobiological Effectiveness of 3D-Conformal Radiotherapy, MLC-Based IMRT and Helical Tomotherapy in Lung Cancer Medical Physics. 35: 2821-2822. DOI: 10.1118/1.2962170  0.423
2008 Stathakis S, Gutiérrez A, Rassiah‐Szegedi P, Mavroidis P, Papanikolaou N. SU‐GG‐T‐244: Commissioning of Flattening Filter Free Varian 600C Linear Accelerator Medical Physics. 35: 2781-2781. DOI: 10.1118/1.2961996  0.355
2008 Desai P, Stathakis S, Gutiérrez A, Mavroidis P, Papanikolaou N. SU‐GG‐T‐173: Investigation of the Transmission Detectors for Daily Dose Verification and QA of IMRT Treatments Medical Physics. 35: 2765-2765. DOI: 10.1118/1.2961925  0.363
2008 Calvo O, Buckey C, Stathakis S, Gutiérrez A, Papanikolaou N. SU‐GG‐T‐101: Validation of Collapse Cone Convolution Superposition Algorithm Using Ion Chamber and Field Measurements Medical Physics. 35: 2749-2749. DOI: 10.1118/1.2961853  0.383
2008 Smith M, Stathakis S, Swanson GP, Joyner M, Gutiérrez A, Papanikolaou N. SU‐GG‐T‐22: Dosimetric Analysis of Real Time and Post Implantation Dosimetry for Prostate Medical Physics. 35: 2731-2731. DOI: 10.1118/1.2961772  0.339
2008 Sarkar V, Gutiérrez A, Stathakis S, Swanson GP, Papanikolaou N. SU‐GG‐J‐10: A Graphical User Interface for Virtual Fluoroscopy to Aid in Prostate Seed Implant Verification Medical Physics. 35: 2680-2680. DOI: 10.1118/1.2961567  0.312
2008 Gutiérrez A, Calvo O, Stathakis S, Rassiah‐Szegedi P, Esquivel C, Papanikolaou N. SU‐DD‐A1‐03: On the Quantification of the Dosimetric Accuracy of Collapsed Cone Convolution Superposition Algorithm for Small Lung Volumes Using IMRT Medical Physics. 35: 2631-2631. DOI: 10.1118/1.2961352  0.413
2007 Gutíerrez AN, Deveau M, Forrest LJ, Tomé WA, Mackie TR. Radiobiological and treatment planning study of a simultaneously integrated boost for canine nasal tumors using helical tomotherapy. Veterinary Radiology & Ultrasound : the Official Journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association. 48: 594-602. PMID 18018736 DOI: 10.1111/J.1740-8261.2007.00304.X  0.544
2007 Gutiérrez AN, Westerly DC, Tomé WA, Jaradat HA, Mackie TR, Bentzen SM, Khuntia D, Mehta MP. Whole brain radiotherapy with hippocampal avoidance and simultaneously integrated brain metastases boost: a planning study. International Journal of Radiation Oncology, Biology, Physics. 69: 589-97. PMID 17869672 DOI: 10.1016/J.Ijrobp.2007.05.038  0.687
2007 Gutierrez A, Deveau M, Forrest L, Tomé W, Mackie T. TU-EE-A2-03: Simultaneous Integrated Boost for Canine Nasal Tumors Using Helical Tomotherapy: A Radiobiological and Treatment Planning Study Medical Physics. 34: 2567-2567. DOI: 10.1118/1.2761424  0.535
2007 Gutiérrez A, Westerly D, Tomé W, Jaradat H, Mackie T, Bentzen S, Khuntia D, Mehta M. Whole Brain Radiation Therapy With Hippocampal Avoidance and Simultaneously Integrated Brain Metastases Boost With Helical Tomotherapy: A Planning Study International Journal of Radiation Oncology*Biology*Physics. 69: S674-S675. DOI: 10.1016/J.Ijrobp.2007.07.2033  0.742
2006 Gutiérrez A, Boswell S, Mackie T. SU-FF-T-150: Consequence of CT Couch Sag in Radiation Therapy Medical Physics. 33: 2083-2083. DOI: 10.1118/1.2241074  0.341
2005 Boswell SA, Jeraj R, Ruchala KJ, Olivera GH, Jaradat HA, James JA, Gutierrez A, Pearson D, Frank G, Mackie TR. A novel method to correct for pitch and yaw patient setup errors in helical tomotherapy. Medical Physics. 32: 1630-9. PMID 16013722 DOI: 10.1118/1.1914543  0.304
2005 Gutierrez A, Murphy S, Jaradat H, Forrest L, Mackie T. SU-FF-J-76: Minimally-Invasive Intraoperative Radiotherapy (MIR): Technique Development for Treatment of Canine Bladder Cancer Medical Physics. 32: 1937-1937. DOI: 10.1118/1.1997622  0.367
Show low-probability matches.