Linxia Gu - Publications

Affiliations: 
Engineering Mechanics The University of Nebraska - Lincoln, Lincoln, NE 
Area:
General Engineering, Biomechanics Biophysics, Applied Mechanics

25 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2020 Shen X, Jiang J, Zhu H, Lu K, Dong P, Gu L. Comparative study of tapered versus conventional cylindrical balloon for stent implantation in stenotic tapered artery. Artificial Organs. PMID 32017159 DOI: 10.1111/Aor.13661  0.317
2019 Dong P, Mozafari H, Prabhu D, Bezerra HG, Wilson DL, Gu L. Oct-based Modeling of Stent Deployment in Heavily Calcified Coronary Lesion. Journal of Biomechanical Engineering. PMID 31654052 DOI: 10.1115/1.4045285  0.329
2019 Zheng Q, Dong P, Li Z, Han X, Zhou C, An M, Gu L. Mechanical characterizations of braided composite stents made of helical polyethylene terephthalate strips and NiTi wires Nanotechnology Reviews. 8: 168-174. DOI: 10.1515/Ntrev-2019-0016  0.322
2017 Hua Y, Wang Y, Gu L. Primary blast waves induced brain dynamics influenced by head orientations. Biomedical Engineering Letters. 7: 253-259. PMID 30603173 DOI: 10.1007/S13534-017-0027-2  0.352
2017 Lin S, Han X, Bi Y, Ju S, Gu L. Fluid-Structure Interaction in Abdominal Aortic Aneurysm: Effect of Modeling Techniques. Biomed Research International. 2017: 7023078. PMID 28321413 DOI: 10.1155/2017/7023078  0.323
2015 Hua Y, Lin S, Gu L. Relevance of Blood Vessel Networks in Blast-Induced Traumatic Brain Injury. Computational and Mathematical Methods in Medicine. 2015: 928236. PMID 26495036 DOI: 10.1155/2015/928236  0.312
2015 Hua Y, Akula P, Kelso M, Gu L. Characterization of Closed Head Impact Injury in Rat. Biomed Research International. 2015: 272976. PMID 26451365 DOI: 10.1155/2015/272976  0.334
2015 Akula P, Hua Y, Gu L. Blast-induced mild traumatic brain injury through ear canal: A finite element study Biomedical Engineering Letters. 5: 281-288. DOI: 10.1007/S13534-015-0204-0  0.324
2014 Zhao S, Gu L. Implementation and validation of aortic remodeling in hypertensive rats. Journal of Biomechanical Engineering. 136: 091007. PMID 24976411 DOI: 10.1115/1.4027939  0.322
2014 Hua Y, Akula PK, Gu L, Berg J, Nelson CA. Experimental and numerical investigation of the mechanism of blast wave transmission through a surrogate head Journal of Computational and Nonlinear Dynamics. 9. DOI: 10.1115/1.4026156  0.347
2014 Hua Y, Akula PK, Gu L. Experimental and numerical investigation of carbon fiber sandwich panels subjected to blast loading Composites Part B-Engineering. 56: 456-463. DOI: 10.1016/J.Compositesb.2013.08.070  0.333
2013 Zhao S, Gu L, Froemming SR. Experimental investigation of the stent-artery interaction. Journal of Medical Engineering & Technology. 37: 463-9. PMID 24044587 DOI: 10.3109/03091902.2013.831491  0.321
2012 Zhao S, Gu L, Froemming SR. Performance of self-expanding nitinol stent in a curved artery: impact of stent length and deployment orientation. Journal of Biomechanical Engineering. 134. PMID 24763629 DOI: 10.1115/1.4007095  0.323
2012 Zhao S, Gu L, Froemming SR. On the importance of modeling stent procedure for predicting arterial mechanics. Journal of Biomechanical Engineering. 134: 121005. PMID 23363207 DOI: 10.1115/1.4023094  0.334
2012 Steinert BD, Zhao S, Gu L. Monitoring the wall mechanics during stent deployment in a vessel. Journal of Visualized Experiments : Jove. e3945. PMID 22588353 DOI: 10.3791/3945  0.312
2012 Ganpule S, Gu L, Alai A, Chandra N. Role of helmet in the mechanics of shock wave propagation under blast loading conditions. Computer Methods in Biomechanics and Biomedical Engineering. 15: 1233-44. PMID 21806412 DOI: 10.1080/10255842.2011.597353  0.692
2012 Gu L, Zhao S, Froemming SR. Arterial Wall Mechanics And Clinical Implications After Coronary Stenting: Comparisons Of Three Stent Designs International Journal of Applied Mechanics. 4: 1250013. DOI: 10.1142/S1758825112500135  0.326
2012 Zhao S, Liu XC, Gu L. The Impact of Wire Stent Fabrication Technique on the Performance of Stent Placement Journal of Medical Devices-Transactions of the Asme. 6: 11007. DOI: 10.1115/1.4005788  0.307
2012 Gu L, Chafi MS, Ganpule S, Chandra N. The influence of heterogeneous meninges on the brain mechanics under primary blast loading Composites Part B-Engineering. 43: 3160-3166. DOI: 10.1016/J.Compositesb.2012.04.014  0.725
2012 Zhao S, Gu L, Froemming SR. Effects of arterial strain and stress in the prediction of restenosis risk: Computer modeling of stent trials Biomedical Engineering Letters. 2: 158-163. DOI: 10.1007/S13534-012-0067-6  0.323
2011 Chafi MS, Ganpule SG, Gu L, Chandra N. Dynamic Response Of Brain Subjected To Blast Loadings: Influence Of Frequency Ranges International Journal of Applied Mechanics. 3: 803-823. DOI: 10.1142/S175882511100124X  0.713
2010 Gu L, Zhao S, Muttyam AK, Hammel JM. The Relation Between the Arterial Stress and Restenosis Rate After Coronary Stenting Journal of Medical Devices-Transactions of the Asme. 4: 31005. DOI: 10.1115/1.4002238  0.332
2008 Muttyam AK, Gu L. The Effect of Stent Design on the Restenosis Rate Journal of Medical Devices-Transactions of the Asme. 2: 27526. DOI: 10.1115/1.2934540  0.33
2007 Gu L, Santra S, Kumar AV. Biomechanics of stent grafts for intracranial aneurysm repair Proceedings of the 2nd Frontiers in Biomedical Devices Conference 2007. 31-32. DOI: 10.1115/Biomed2007-38025  0.301
2005 Gu L, Santra S, Mericle RA, Kumar AV. Finite element analysis of covered microstents. Journal of Biomechanics. 38: 1221-7. PMID 15863106 DOI: 10.1016/J.Jbiomech.2004.06.008  0.344
Show low-probability matches.