Yixian Qin - Publications

Affiliations: 
Stony Brook University, Stony Brook, NY, United States 
Area:
Mechanical Engineering, Biomedical Engineering

93 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2023 Zhou J, Georgas E, Su Y, Zhou J, Kröger N, Benn F, Kopp A, Qin YX, Zhu D. Evolution from Bioinert to Bioresorbable: In Vivo Comparative Study of Additively Manufactured Metal Bone Scaffolds. Advanced Science (Weinheim, Baden-Wurttemberg, Germany). e2302702. PMID 37424385 DOI: 10.1002/advs.202302702  0.335
2021 Sun S, Tang L, Zhao T, Kang Y, Sun L, Liu C, Li Y, Xu F, Qin YX, Ta D. Longitudinal effects of low-intensity pulsed ultrasound on osteoporosis and osteoporotic bone defect in ovariectomized rats. Ultrasonics. 113: 106360. PMID 33561635 DOI: 10.1016/j.ultras.2021.106360  0.335
2020 Cockerill I, Su Y, Sinha S, Qin YX, Zheng Y, Young ML, Zhu D. Porous zinc scaffolds for bone tissue engineering applications: A novel additive manufacturing and casting approach. Materials Science & Engineering. C, Materials For Biological Applications. 110: 110738. PMID 32204047 DOI: 10.1016/J.Msec.2020.110738  0.446
2020 Yi X, Wu L, Liu J, Qin YX, Li B, Zhou Q. Low-intensity pulsed ultrasound protects subchondral bone in rabbit temporomandibular joint osteoarthritis by suppressing TGF-β1/Smad3 pathway. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. PMID 32060941 DOI: 10.1002/Jor.24628  0.395
2019 Yu W, Wu X, Cen H, Guo Y, Li C, Wang Y, Qin Y, Chen W. Study on the biomechanical responses of the loaded bone in macroscale and mesoscale by multiscale poroelastic FE analysis. Biomedical Engineering Online. 18: 122. PMID 31870380 DOI: 10.1186/S12938-019-0741-3  0.463
2019 Hu M, Lee W, Jiao J, Li X, Gibbons DE, Hassan CR, Tian GW, Qin YX. Mechanobiological modulation of in situ and in vivo osteocyte calcium oscillation by acoustic radiation force. Annals of the New York Academy of Sciences. PMID 31646646 DOI: 10.1111/Nyas.14262  0.309
2019 Sun S, Sun L, Kang Y, Tang L, Qin YX, Ta D. Therapeutic Effects of Low-Intensity Pulsed Ultrasound on Osteoporosis in Ovariectomized Rats: Intensity-Dependent Study. Ultrasound in Medicine & Biology. PMID 31587953 DOI: 10.1016/J.Ultrasmedbio.2019.08.025  0.433
2019 Qin YX, Xia Y, Muir J, Lin W, Rubin CT. Quantitative ultrasound imaging monitoring progressive disuse osteopenia and mechanical stimulation mitigation in calcaneus region through a 90-day bed rest human study. Journal of Orthopaedic Translation. 18: 48-58. PMID 31508307 DOI: 10.1016/J.Jot.2018.11.004  0.449
2019 Grover K, Hu M, Lin L, Muir J, Qin YX. Functional disuse initiates medullary endosteal micro-architectural impairment in cortical bone characterized by nanoindentation. Journal of Bone and Mineral Metabolism. PMID 31292723 DOI: 10.1007/S00774-019-01011-1  0.454
2019 Wang Y, Xue Y, Wang J, Zhu Y, Zhu Y, Zhang X, Liao J, Li X, Wu X, Qin YX, Chen W. A Composite Hydrogel with High Mechanical Strength, Fluorescence, and Degradable Behavior for Bone Tissue Engineering. Polymers. 11. PMID 31266178 DOI: 10.3390/Polym11071112  0.346
2019 Zhu D, Cockerill I, Su Y, Zhang Z, Fu J, Lee KW, Ma J, Okpokwasili C, Tang L, Zheng Y, Qin YX, Wang Y. Mechanical Strength, Biodegradation, and In Vitro and In Vivo Biocompatibility of Zn Biomaterials. Acs Applied Materials & Interfaces. PMID 30693753 DOI: 10.1021/Acsami.8B20634  0.302
2019 Zhang D, Miranda M, Li X, Han J, Sun Y, Rojas N, He S, Hu M, Lin L, Li X, Ke HZ, Qin YX. Retention of osteocytic micromorphology by sclerostin antibody in a concurrent ovariectomy and functional disuse model. Annals of the New York Academy of Sciences. PMID 30644553 DOI: 10.1111/Nyas.13991  0.482
2018 Li X, Sun Y, Zhou Z, Zhang D, Jiao J, Hu M, Hassan CR, Qin YX. Mitigation of Articular Cartilage Degeneration and Subchondral Bone Sclerosis in Osteoarthritis Progression Using Low-Intensity Ultrasound Stimulation. Ultrasound in Medicine & Biology. PMID 30322672 DOI: 10.1016/J.Ultrasmedbio.2018.08.022  0.391
2018 Liu J, Li X, Zhang D, Jiao J, Wu L, Hao F, Qin YX. Acceleration of Bone Defect Healing and Regeneration by Low-Intensity Ultrasound Radiation Force in a Rat Tibial Model. Ultrasound in Medicine & Biology. PMID 30286949 DOI: 10.1016/J.Ultrasmedbio.2018.08.002  0.483
2018 Moonga SS, Qin YX. MC3T3 infiltration and proliferation in bovine trabecular scaffold regulated by dynamic flow bioreactor and augmented by low-intensity pulsed ultrasound. Journal of Orthopaedic Translation. 14: 16-22. PMID 30035029 DOI: 10.1016/J.Jot.2018.02.002  0.384
2017 Zhang ZK, Guo X, Lao J, Qin YX. Effect of capsaicin-sensitive sensory neurons on bone architecture and mechanical properties in the rat hindlimb suspension model. Journal of Orthopaedic Translation. 10: 12-17. PMID 29662756 DOI: 10.1016/J.Jot.2017.03.001  0.379
2017 Gadomski BC, McGilvray KC, Easley JT, Palmer RH, Jiao J, Li X, Qin YX, Puttlitz CM. An Investigation of Shock Wave Therapy and Low-Intensity Pulsed Ultrasound on Fracture Healing Under Reduced Loading Conditions in an Ovine Model. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. PMID 28762588 DOI: 10.1002/Jor.23666  0.392
2017 Meng Y, Faillace ME, Dorst K, Palmaccio SJ, Miller LM, Qin YX. In situ examination of osteoblast biomineralization on sulfonated polystyrene-modified substrates using Fourier transform infrared microspectroscopy. Biointerphases. 12: 031001. PMID 28693327 DOI: 10.1116/1.4992137  0.433
2017 Saikia E, Hassan CR, Qin Y. Simulation of phased array ultrasound propagation for fluid flow regulation in enhancement of bone adaptation Journal of the Acoustical Society of America. 141: 4015-4015. DOI: 10.1121/1.4989229  0.401
2016 Vojdani S, Fernandez L, Jiao J, Enders T, Ortiz S, Lin L, Qin YX, Komatsu DE, Penna J, Ruotolo CJ. Novel Spiked-Washer Repair Is Biomechanically Superior To Suture And Bone Tunnels for Arcuate Fracture Repair. Journal of Orthopaedic Trauma. PMID 27984448 DOI: 10.1097/Bot.0000000000000752  0.331
2016 Zheng Y, Wang Q, Li T, Qian J, Lu Y, Li Y, Bi E, Reu F, Qin Y, Drazba J, Hsi E, Yang J, Cai Z, Yi Q. Role of Myeloma-Derived MIF in Myeloma Cell Adhesion to Bone Marrow and Chemotherapy Response. Journal of the National Cancer Institute. 108. PMID 27381622 DOI: 10.1093/jnci/djw131  0.334
2016 Qin W, Li X, Peng Y, Harlow LM, Ren Y, Wu Y, Li J, Qin Y, Sun J, Zheng S, Brown T, Feng JQ, Ke HZ, Bauman WA, Cardozo CP. Sclerostin Antibody Preserves the Morphology and Structure of Osteocytes and Blocks the Severe Skeletal Deterioration After Motor-Complete Spinal Cord Injury in Rats. Journal of Bone and Mineral Research : the Official Journal of the American Society For Bone and Mineral Research. 31: 1482. PMID 27377772 DOI: 10.1002/Jbmr.2864  0.347
2016 Zhang D, Hu M, Chu T, Lin L, Wang J, Li X, Ke HZ, Qin YX. Erratum to Sclerostin antibody prevented progressive bone loss in combined ovariectomized and concurrent functional disuse [Bone 87 (2016) 161-168]. Bone. PMID 27262889 DOI: 10.1016/J.Bone.2016.05.007  0.452
2016 Zhang D, Hu M, Chu T, Lin L, Wang J, Li X, Ke HZ, Qin YX. Sclerostin antibody prevented progressive bone loss in combined ovariectomized and concurrent functional disuse. Bone. PMID 26868528 DOI: 10.1016/J.Bone.2016.02.005  0.487
2016 Qin Y, Liu J, Zhang D, Li X. Acceleration of critical bone defect healing by guided low-intensity ultrasound in a rat tibial model Journal of the Acoustical Society of America. 140: 3191-3191. DOI: 10.1121/1.4970041  0.44
2015 Grover K, Lin L, Hu M, Muir J, Qin YX. Spatial distribution and remodeling of elastic modulus of bone in micro-regime as prediction of early stage osteoporosis. Journal of Biomechanics. PMID 26705110 DOI: 10.1016/J.Jbiomech.2015.11.052  0.374
2015 Hu M, Tian GW, Gibbons DE, Jiao J, Qin YX. Dynamic fluid flow induced mechanobiological modulation of in situ osteocyte calcium oscillations. Archives of Biochemistry and Biophysics. 579: 55-61. PMID 26045248 DOI: 10.1016/J.Abb.2015.05.012  0.428
2015 Lin L, Lin W, Qin YX. Enhanced correlation between quantitative ultrasound and structural and mechanical properties of bone using combined transmission-reflection measurement. The Journal of the Acoustical Society of America. 137: 1144-52. PMID 25786930 DOI: 10.1121/1.4906830  0.426
2015 Uddin SM, Qin YX. Dynamic acoustic radiation force retains bone structural and mechanical integrity in a functional disuse osteopenia model. Bone. 75: 8-17. PMID 25661670 DOI: 10.1016/J.Bone.2015.01.020  0.49
2015 Zhou Y, Mohan A, Moore DC, Lin L, Zhou FL, Cao J, Wu Q, Qin YX, Reginato AM, Ehrlich MG, Yang W. SHP2 regulates osteoclastogenesis by promoting preosteoclast fusion. Faseb Journal : Official Publication of the Federation of American Societies For Experimental Biology. 29: 1635-45. PMID 25593124 DOI: 10.1096/Fj.14-260844  0.377
2015 Wu L, Lin L, Qin YX. Enhancement of cell ingrowth, proliferation, and early differentiation in a three-dimensional silicon carbide scaffold using low-intensity pulsed ultrasound. Tissue Engineering. Part A. 21: 53-61. PMID 24935158 DOI: 10.1089/Ten.Tea.2013.0597  0.32
2015 Shrivastava V, Patel S, Hu M, Pongkitwitoon S, Sitharaman B, Qin Y. Enhancement of osteogenesis and stem cell differentiation by injectable nanocomposite and dynamic acoustic radiation force stimulation The Journal of the Acoustical Society of America. 137: 2314-2314. DOI: 10.1121/1.4920444  0.348
2015 Jiao J, Li X, Lin L, Sahul R, Nesvijski E, Qin Y. Broadband ultrasound scanning and frequency sweep measurement for trabecular bone with novel wideband single crystal transducer The Journal of the Acoustical Society of America. 137: 2288-2288. DOI: 10.1121/1.4920351  0.441
2015 Qin Y, Muir J. Quantitative ultrasound imaging reconstruction in peripheral skeletal assessment Journal of the Acoustical Society of America. 137: 2287-2287. DOI: 10.1121/1.4920348  0.324
2014 Qin YX, Hu M. Mechanotransduction in musculoskeletal tissue regeneration: effects of fluid flow, loading, and cellular-molecular pathways. Biomed Research International. 2014: 863421. PMID 25215295 DOI: 10.1155/2014/863421  0.464
2014 Pei GX, Qin YX, Hutmacher DW, Zhang ZY. Bone tissue engineering: cell motility, vascularization, micro-nano scaffolding, and remodeling. Biomed Research International. 2014: 286978. PMID 25210708 DOI: 10.1155/2014/286978  0.433
2014 Hu M, Cheng J, Bethel N, Serra-Hsu F, Ferreri S, Lin L, Qin YX. Interrelation between external oscillatory muscle coupling amplitude and in vivo intramedullary pressure related bone adaptation. Bone. 66: 178-81. PMID 24947450 DOI: 10.1016/J.Bone.2014.05.018  0.475
2014 Hu M, Qin YX. Dynamic fluid flow stimulation on cortical bone and alterations of the gene expressions of osteogenic growth factors and transcription factors in a rat functional disuse model. Archives of Biochemistry and Biophysics. 545: 154-61. PMID 24486201 DOI: 10.1016/J.Abb.2014.01.021  0.399
2014 Xu K, Ta D, He R, Qin YX, Wang W. Axial transmission method for long bone fracture evaluation by ultrasonic guided waves: simulation, phantom and in vitro experiments. Ultrasound in Medicine & Biology. 40: 817-27. PMID 24433749 DOI: 10.1016/J.Ultrasmedbio.2013.10.019  0.335
2014 Lin L, Oon HY, Lin W, Qin YX. Principal trabecular structural orientation predicted by quantitative ultrasound is strongly correlated with μFEA determined anisotropic apparent stiffness. Biomechanics and Modeling in Mechanobiology. 13: 961-71. PMID 24419558 DOI: 10.1007/S10237-013-0547-3  0.461
2014 Klein GL, Xie Y, Qin YX, Lin L, Hu M, Enkhbaatar P, Bonewald LF. Preliminary evidence of early bone resorption in a sheep model of acute burn injury: an observational study. Journal of Bone and Mineral Metabolism. 32: 136-41. PMID 23784552 DOI: 10.1007/S00774-013-0483-4  0.322
2014 Lin L, Ambike E, Sahul R, Qin Y. Super wideband quantitative ultrasound imaging for trabecular bone with novel wideband single crystal transducer and frequency sweep measurement The Journal of the Acoustical Society of America. 135: 2372-2372. DOI: 10.1121/1.4877827  0.469
2014 Qin Y, Muir J, Cheng J, Lin L, Lin W. Acoustic imaging for bone diagnosis using a hand-held focal quantitative ultrasound Journal of Orthopaedic Translation. 2: 209-210. DOI: 10.1016/J.Jot.2014.07.138  0.409
2013 Ni Q, Dixon H, Gutierrez G, Bi L, Qin YX. Characterization of synthesized NANO-encapsulated drug for bone loss on hind limb suspension rat model by NMR and micro-CT. Advances in Bioscience and Bioengineering (New York, Ny). 1: 1-7. PMID 28042594 DOI: 10.11648/J.Abb.20130101.11  0.427
2013 Hu M, Yeh R, Lien M, Teeratananon M, Agarwal K, Qin YX. Dynamic Fluid Flow Mechanical Stimulation Modulates Bone Marrow Mesenchymal Stem Cells. Bone Research. 1: 98-104. PMID 26273495 DOI: 10.4248/Br201301007  0.478
2013 Uddin SM, Qin YX. Enhancement of osteogenic differentiation and proliferation in human mesenchymal stem cells by a modified low intensity ultrasound stimulation under simulated microgravity. Plos One. 8: e73914. PMID 24069248 DOI: 10.1371/Journal.Pone.0073914  0.317
2013 Qin YX, Lin W, Mittra E, Xia Y, Cheng J, Judex S, Rubin C, Müller R. Prediction of trabecular bone qualitative properties using scanning quantitative ultrasound. Acta Astronautica. 92: 79-88. PMID 23976803 DOI: 10.1016/J.Actaastro.2012.08.032  0.483
2013 Hu M, Serra-Hsu F, Bethel N, Lin L, Ferreri S, Cheng J, Qin YX. Dynamic hydraulic fluid stimulation regulated intramedullary pressure. Bone. 57: 137-41. PMID 23895997 DOI: 10.1016/J.Bone.2013.07.030  0.479
2013 Uddin SM, Hadjiargyrou M, Cheng J, Zhang S, Hu M, Qin YX. Reversal of the detrimental effects of simulated microgravity on human osteoblasts by modified low intensity pulsed ultrasound. Ultrasound in Medicine & Biology. 39: 804-12. PMID 23453382 DOI: 10.1016/J.Ultrasmedbio.2012.11.016  0.368
2013 Lin L, Lin W, Qin Y. Integrated transmission-reflection quantitative ultrasound noninvasive prediction of trabecular bone principal structural orientation validated with mechanical testing The Journal of the Acoustical Society of America. 134: 4121-4121. DOI: 10.1121/1.4831140  0.385
2012 Hu M, Cheng J, Qin YX. Dynamic hydraulic flow stimulation on mitigation of trabecular bone loss in a rat functional disuse model. Bone. 51: 819-25. PMID 22820398 DOI: 10.1016/J.Bone.2012.06.030  0.483
2012 Zhang S, Cheng J, Qin YX. Mechanobiological modulation of cytoskeleton and calcium influx in osteoblastic cells by short-term focused acoustic radiation force. Plos One. 7: e38343. PMID 22701628 DOI: 10.1371/Journal.Pone.0038343  0.382
2012 Lin L, Cheng J, Lin W, Qin YX. Prediction of trabecular bone principal structural orientation using quantitative ultrasound scanning. Journal of Biomechanics. 45: 1790-5. PMID 22560370 DOI: 10.1016/J.Jbiomech.2012.04.022  0.477
2012 Qin Y, Zhang S, Ferreri S, Cheng J. Therapeutic ultrasound on bone cellular and in vivo adaptation The Journal of the Acoustical Society of America. 131: 3458-3458. DOI: 10.1121/1.4709032  0.439
2012 Xu K, He R, Ta D, Qin Y, Sun P, Wang W. A simulation and experimental study of long cortical bones fracture evaluation using lamb waves Journal of the Acoustical Society of America. 131: 3425-3425. DOI: 10.1121/1.4708845  0.353
2011 Zia Uddin SM, Cheng J, Lin W, Qin YX. Low-Intensity Amplitude Modulated Ultrasound Increases Osteoblastic Mineralization. Cellular and Molecular Bioengineering. 4: 81-90. PMID 28018491 DOI: 10.1007/S12195-010-0153-8  0.32
2011 Cheng J, Serra-Hsu F, Tian Y, Lin W, Qin YX. Effects of phase cancellation and receiver aperture size on broadband ultrasonic attenuation for trabecular bone in vitro. Ultrasound in Medicine & Biology. 37: 2116-25. PMID 22033134 DOI: 10.1016/J.Ultrasmedbio.2011.08.009  0.382
2011 Serra-Hsu F, Cheng J, Lynch T, Qin YX. Evaluation of a pulsed phase-locked loop system for noninvasive tracking of bone deformation under loading with finite element and strain analysis. Physiological Measurement. 32: 1301-13. PMID 21765205 DOI: 10.1088/0967-3334/32/8/019  0.482
2011 Ferreri SL, Talish R, Trandafir T, Qin YX. Mitigation of bone loss with ultrasound induced dynamic mechanical signals in an OVX induced rat model of osteopenia. Bone. 48: 1095-102. PMID 21241838 DOI: 10.1016/J.Bone.2011.01.002  0.459
2011 Lam H, Hu M, Qin YX. Alteration of contraction-to-rest ratio to optimize trabecular bone adaptation induced by dynamic muscle stimulation. Bone. 48: 399-405. PMID 20850577 DOI: 10.1016/J.Bone.2010.09.018  0.456
2011 Ni Q, Dixon H, Qin Y. Synthesis and Characterization of Nano-encapsulated Drug Delivery System for Bone Loss Energy Procedia. 11: 2748-2755. DOI: 10.1016/J.Egypro.2011.10.604  0.39
2010 Lam H, Brink P, Qin YX. Skeletal nutrient vascular adaptation induced by external oscillatory intramedullary fluid pressure intervention. Journal of Orthopaedic Surgery and Research. 5: 18. PMID 20222973 DOI: 10.1186/1749-799X-5-18  0.403
2010 Ozcivici E, Luu YK, Adler B, Qin YX, Rubin J, Judex S, Rubin CT. Mechanical signals as anabolic agents in bone. Nature Reviews. Rheumatology. 6: 50-9. PMID 20046206 DOI: 10.1038/Nrrheum.2009.239  0.38
2010 Serra‐Hsu F, Cheng J, Lin W, Qin Y. Bone quality assessment at multiple skeletal sites using quantitative ultrasound imaging. The Journal of the Acoustical Society of America. 127: 2034-2034. DOI: 10.1121/1.3385343  0.385
2010 Qin Y, Cheng J, Ferreri S, Lin W. Characterization of cortical bone fracture with scanning confocal ultrasound and longitudinal acoustic velocity. The Journal of the Acoustical Society of America. 127: 2033-2033. DOI: 10.1121/1.3385341  0.363
2009 Lin W, Xia Y, Qin YX. Characterization of the trabecular bone structure using frequency modulated ultrasound pulse. The Journal of the Acoustical Society of America. 125: 4071-7. PMID 19507988 DOI: 10.1121/1.3126993  0.344
2009 Qin YX, Lam H. Intramedullary pressure and matrix strain induced by oscillatory skeletal muscle stimulation and its potential in adaptation. Journal of Biomechanics. 42: 140-5. PMID 19081096 DOI: 10.1016/J.Jbiomech.2008.10.018  0.434
2009 Meng Y, Qin YX, DiMasi E, Ba X, Rafailovich M, Pernodet N. Biomineralization of a self-assembled extracellular matrix for bone tissue engineering. Tissue Engineering. Part A. 15: 355-66. PMID 18759666 DOI: 10.1089/Ten.Tea.2007.0371  0.459
2009 Qin Y, Lam H, Malbari M, Shih M, Carroll W. Inhibition of bone loss using dynamic muscle stimulation in a disuse osteopenia model Bone. 44. DOI: 10.1016/J.Bone.2009.01.341  0.385
2008 Lam H, Qin YX. The effects of frequency-dependent dynamic muscle stimulation on inhibition of trabecular bone loss in a disuse model. Bone. 43: 1093-100. PMID 18757047 DOI: 10.1016/J.Bone.2008.07.253  0.409
2008 Ozcivici E, Ferreri S, Qin YX, Judex S. Determination of bone's mechanical matrix properties by nanoindentation. Methods in Molecular Biology (Clifton, N.J.). 455: 323-34. PMID 18463828 DOI: 10.1007/978-1-59745-104-8_22  0.477
2008 Mittra E, Rubin C, Gruber B, Qin YX. Evaluation of trabecular mechanical and microstructural properties in human calcaneal bone of advanced age using mechanical testing, microCT, and DXA. Journal of Biomechanics. 41: 368-75. PMID 17953972 DOI: 10.1016/J.Jbiomech.2007.09.003  0.494
2008 Qin Y, Xia Y, Lin W, Cheng J, Muir J, Rubin C. Longitudinal assessment of human bone quality using scanning confocal quantitative ultrasound Journal of the Acoustical Society of America. 123: 3638-3638. DOI: 10.1121/1.2934896  0.474
2008 Szczupak M, Xia Y, Cheng J, Qin Y. Fracture and bone defect assessment using quantitative ultrasound wave propagation The Journal of the Acoustical Society of America. 123: 3633-3633. DOI: 10.1121/1.2934873  0.404
2008 Qin Y, Malbari M, Shih M, Carroll W. Inhibition of bone loss using duration-sensitive dynamic muscle stimulation in a disuse rat model Bone. 43: S57. DOI: 10.1016/J.Bone.2008.08.055  0.376
2008 Qin Y, Xia Y, Wei L, Gruber B, Rubin C. Noninvasive characterization of trabecular bone quality in human using scanning quantitative ultrasound imaging Bone. 43. DOI: 10.1016/J.Bone.2008.07.100  0.411
2008 Qin Y. Potential new treatment for metabolic bone diseases—Exercise and anabolic agents Bone. 43. DOI: 10.1016/J.Bone.2008.07.070  0.385
2007 Ni Q, Santos ADL, Lam H, Qin Y. Assessment of simulated and functional disuse on cortical bone by nuclear magnetic resonance Advances in Space Research. 40: 1703-1710. DOI: 10.1016/J.Asr.2007.07.021  0.426
2006 Rubin C, Judex S, Qin YX. Low-level mechanical signals and their potential as a non-pharmacological intervention for osteoporosis. Age and Ageing. 35: ii32-ii36. PMID 16926201 DOI: 10.1093/Ageing/Afl082  0.465
2006 Mittra E, Akella S, Qin YX. The effects of embedding material, loading rate and magnitude, and penetration depth in nanoindentation of trabecular bone. Journal of Biomedical Materials Research. Part A. 79: 86-93. PMID 16758456 DOI: 10.1002/Jbm.A.30742  0.449
2006 Mankani MH, Kuznetsov SA, Shannon B, Nalla RK, Ritchie RO, Qin Y, Robey PG. Canine cranial reconstruction using autologous bone marrow stromal cells. The American Journal of Pathology. 168: 542-50. PMID 16436668 DOI: 10.2353/Ajpath.2006.050407  0.445
2006 Meng Y, Ba X, Kwak S, DiMasi E, Ruppel M, Miller L, Ge S, Pernodet N, Rafailovich M, Qin Y. Effect of Substrate Surface Modification on Biomineralization of Osteoblasts Mrs Proceedings. 950. DOI: 10.1557/Proc-0950-D10-09  0.446
2005 Xia Y, Lin W, Qin YX. The influence of cortical end-plate on broadband ultrasound attenuation measurements at the human calcaneus using scanning confocal ultrasound. The Journal of the Acoustical Society of America. 118: 1801-7. PMID 16240838 DOI: 10.1121/1.1979428  0.452
2005 Mittra E, Rubin C, Qin YX. Interrelationship of trabecular mechanical and microstructural properties in sheep trabecular bone. Journal of Biomechanics. 38: 1229-37. PMID 15863107 DOI: 10.1016/J.Jbiomech.2004.06.007  0.501
2004 Qin Y, Xia Y, Lin W, Rubin C, Gruber B. Assessment of trabecular bone quality in human cadaver calcaneus using scanning confocal ultrasound and dual x‐ray absorptiometry (DEXA) measurements The Journal of the Acoustical Society of America. 116: 2492-2492. DOI: 10.1121/1.4784949  0.469
2003 Judex S, Boyd S, Qin YX, Miller L, Müller R, Rubin C. Combining high-resolution micro-computed tomography with material composition to define the quality of bone tissue. Current Osteoporosis Reports. 1: 11-9. PMID 16036060 DOI: 10.1007/S11914-003-0003-X  0.495
2003 Judex S, Boyd S, Qin YX, Turner S, Ye K, Müller R, Rubin C. Adaptations of trabecular bone to low magnitude vibrations result in more uniform stress and strain under load. Annals of Biomedical Engineering. 31: 12-20. PMID 12572652 DOI: 10.1114/1.1535414  0.396
2002 Rubin C, Turner AS, Müller R, Mittra E, McLeod K, Lin W, Qin YX. Quantity and quality of trabecular bone in the femur are enhanced by a strongly anabolic, noninvasive mechanical intervention. Journal of Bone and Mineral Research : the Official Journal of the American Society For Bone and Mineral Research. 17: 349-57. PMID 11811566 DOI: 10.1359/Jbmr.2002.17.2.349  0.484
2002 Lin W, Qin YX, Rubin C. Ultrasonic wave propagation in trabecular bone predicted by the stratified model. Annals of Biomedical Engineering. 29: 781-90. PMID 11599586 DOI: 10.1114/1.1397787  0.48
2001 Rubin CT, Sommerfeldt DW, Judex S, Qin YX. Inhibition of osteopenia by low magnitude, high-frequency mechanical stimuli Drug Discovery Today. 6: 848-858. DOI: 10.1016/S1359-6446(01)01872-4  0.489
1998 McLeod KJ, Rubin CT, Otter MW, Qin YX. Skeletal cell stresses and bone adaptation. The American Journal of the Medical Sciences. 316: 176-83. PMID 9749559 DOI: 10.1016/S0002-9629(15)40398-2  0.472
1998 Qin YX, Rubin CT, McLeod KJ. Nonlinear dependence of loading intensity and cycle number in the maintenance of bone mass and morphology. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 16: 482-9. PMID 9747791 DOI: 10.1002/Jor.1100160414  0.374
1996 Rubin C, Gross T, Qin YX, Fritton S, Guilak F, McLeod K. Differentiation of the bone-tissue remodeling response to axial and torsional loading in the turkey ulna. The Journal of Bone and Joint Surgery. American Volume. 78: 1523-33. PMID 8876580 DOI: 10.2106/00004623-199610000-00010  0.458
Show low-probability matches.