Year |
Citation |
Score |
2010 |
Bangera NB, Schomer DL, Dehghani N, Ulbert I, Cash S, Papavasiliou S, Eisenberg SR, Dale AM, Halgren E. Experimental validation of the influence of white matter anisotropy on the intracranial EEG forward solution. Journal of Computational Neuroscience. 29: 371-87. PMID 20063051 DOI: 10.1007/S10827-009-0205-Z |
0.37 |
|
2004 |
Mocanu D, Kettenbach J, Sweeney MO, Kikinis R, Kenknight BH, Eisenberg SR. Patient-specific computational analysis of transvenous defibrillation: a comparison to clinical metrics in humans. Annals of Biomedical Engineering. 32: 775-83. PMID 15255208 DOI: 10.1023/B:Abme.0000030253.95538.80 |
0.601 |
|
2004 |
Mocanu D, Kettenbach J, Sweeney MO, Kikinis R, Kenknight BH, Eisenberg SR. A comparison of biventricular and conventional transvenous defibrillation: a computational study using patient derived models. Pacing and Clinical Electrophysiology : Pace. 27: 586-93. PMID 15125713 DOI: 10.1111/J.1540-8159.2004.00491.X |
0.599 |
|
2003 |
Cullinane DM, Salisbury KT, Alkhiary Y, Eisenberg S, Gerstenfeld L, Einhorn TA. Effects of the local mechanical environment on vertebrate tissue differentiation during repair: does repair recapitulate development? The Journal of Experimental Biology. 206: 2459-71. PMID 12796461 DOI: 10.1242/Jeb.00453 |
0.308 |
|
2000 |
Bursać P, McGrath CV, Eisenberg SR, Stamenović D. A microstructural model of elastostatic properties of articular cartilage in confined compression. Journal of Biomechanical Engineering. 122: 347-53. PMID 11036557 DOI: 10.1115/1.1286561 |
0.349 |
|
1999 |
Bursać PM, Obitz TW, Eisenberg SR, Stamenović D. Confined and unconfined stress relaxation of cartilage: appropriateness of a transversely isotropic analysis. Journal of Biomechanics. 32: 1125-30. PMID 10476852 DOI: 10.1016/S0021-9290(99)00105-0 |
0.308 |
|
1998 |
Levenston ME, Eisenberg SR, Grodzinsky AJ. A variational formulation for coupled physicochemical flows during finite deformations of charged porous media International Journal of Solids and Structures. 35: 4999-5019. DOI: 10.1016/S0020-7683(98)00106-1 |
0.623 |
|
1997 |
Kinst TF, Sweeney MO, Lehr JL, Eisenberg SR. Simulated internal defibrillation in humans using an anatomically realistic three-dimensional finite element model of the thorax. Journal of Cardiovascular Electrophysiology. 8: 537-47. PMID 9160230 DOI: 10.1111/J.1540-8167.1997.Tb00822.X |
0.467 |
|
1995 |
Camacho MA, Lehr JL, Eisenberg SR. A three-dimensional finite element model of human transthoracic defibrillation: paddle placement and size. Ieee Transactions On Bio-Medical Engineering. 42: 572-8. PMID 7790013 DOI: 10.1109/10.387196 |
0.377 |
|
1995 |
Ragan PM, Wang W, Eisenberg SR. Magnetically induced currents in the canine heart: a finite element study. Ieee Transactions On Bio-Medical Engineering. 42: 1110-6. PMID 7498915 DOI: 10.1109/10.469378 |
0.409 |
|
1994 |
Karlon WJ, Lehr JL, Eisenberg SR. Finite element models of thoracic conductive anatomy: sensitivity to changes in inhomogeneity and anisotropy. Ieee Transactions On Bio-Medical Engineering. 41: 1010-7. PMID 8001989 DOI: 10.1109/10.335838 |
0.37 |
|
1994 |
Wang W, Eisenberg SR. A three-dimensional finite element method for computing magnetically induced currents in tissues Ieee Transactions On Magnetics. 30: 5015-5023. DOI: 10.1109/20.334289 |
0.38 |
|
1994 |
Chammas P, Federspiel WJ, Eisenberg SR. A Microcontinuum Model of Electrokinetic Coupling in the Extracellular Matrix: Perturbation Formulation and Solution Journal of Colloid and Interface Science. 168: 526-538. DOI: 10.1006/Jcis.1994.1451 |
0.323 |
|
1993 |
Karlon WJ, Eisenberg SR, Lehr JL. Effects of paddle placement and size on defibrillation current distribution: a three-dimensional finite element model. Ieee Transactions On Bio-Medical Engineering. 40: 246-55. PMID 8335328 DOI: 10.1109/10.216408 |
0.418 |
|
1989 |
Ramirez IF, Eisenberg SR, Lehr JL, Schoen FJ. Effects of cardiac configuration, paddle placement and paddle size on defibrillation current distribution: a finite-element model Medical & Biological Engineering & Computing. 27: 587-594. DOI: 10.1007/Bf02441640 |
0.379 |
|
1987 |
Eisenberg SR, Grodzinsky AJ. The kinetics of chemically induced nonequilibrium swelling of articular cartilage and corneal stroma. Journal of Biomechanical Engineering. 109: 79-89. PMID 3560885 DOI: 10.1115/1.3138647 |
0.548 |
|
1985 |
Eisenberg SR, Grodzinsky AJ. Swelling of articular cartilage and other connective tissues: electromechanochemical forces. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 3: 148-59. PMID 3998893 DOI: 10.1002/Jor.1100030204 |
0.512 |
|
1984 |
Eisenberg SR, Grodzinsky AJ. Electrically modulated membrane permeability Journal of Membrane Science. 19: 173-194. DOI: 10.1016/S0376-7388(00)80207-0 |
0.489 |
|
1978 |
Grodzinsky AJ, Eisenberg SR. Double layer mediated energy conversion with a protein membrane using an imposed frequency and wavelength Journal of Electrostatics. 5: 33-50. DOI: 10.1016/0304-3886(78)90006-2 |
0.458 |
|
Show low-probability matches. |