Year |
Citation |
Score |
2006 |
Catelas I, Campbell PA, Bobyn JD, Medley JB, Huk OL. Wear particles from metal-on-metal total hip replacements: effects of implant design and implantation time. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine. 220: 195-208. PMID 16669387 DOI: 10.1243/09544119JEIM112 |
0.722 |
|
2006 |
Varano R, Bobyn JD, Medley JB, Yue S. The effect of microstructure on the wear of cobalt-based alloys used in metal-on-metal hip implants. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine. 220: 145-59. PMID 16669383 |
0.306 |
|
2004 |
Catelas I, Medley JB, Campbell PA, Huk OL, Bobyn JD. Comparison of in vitro with in vivo characteristics of wear particles from metal-metal hip implants. Journal of Biomedical Materials Research. Part B, Applied Biomaterials. 70: 167-78. PMID 15264297 DOI: 10.1002/Jbm.B.20036 |
0.747 |
|
2003 |
Catelas I, Bobyn JD, Medley JB, Krygier JJ, Zukor DJ, Huk OL. Size, shape, and composition of wear particles from metal-metal hip simulator testing: effects of alloy and number of loading cycles. Journal of Biomedical Materials Research. Part A. 67: 312-27. PMID 14517891 DOI: 10.1002/Jbm.A.10088 |
0.746 |
|
2001 |
Catelas I, Bobyn JD, Medley JJ, Zukor DJ, Petit A, Huk OL. Effects of digestion protocols on the isolation and characterization of metal-metal wear particles. II. Analysis of ion release and particle composition. Journal of Biomedical Materials Research. 55: 330-7. PMID 11255186 DOI: 10.1002/1097-4636(20010605)55:3<330::Aid-Jbm1021>3.0.Co;2-Y |
0.725 |
|
2001 |
Catelas I, Bobyn JD, Medley JB, Krygier JJ, Zukor DJ, Petit A, Huk OL. Effects of digestion protocols on the isolation and characterization of metal-metal wear particles. I. Analysis of particle size and shape. Journal of Biomedical Materials Research. 55: 320-9. PMID 11255185 DOI: 10.1002/1097-4636(20010605)55:3<320::Aid-Jbm1020>3.0.Co;2-3 |
0.739 |
|
1999 |
Chan FW, Bobyn JD, Medley JB, Krygier JJ, Tanzer M. The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants. Clinical Orthopaedics and Related Research. 10-24. PMID 10611857 |
0.442 |
|
1997 |
Medley JB, Krygier JJ, Bobyn JD, Chan FW, Lippincott A, Tanzer M. Kinematics of the MATCO hip simulator and issues related to wear testing of metal-metal implants. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine. 211: 89-99. PMID 9141894 |
0.4 |
|
1996 |
Chan FW, Bobyn JD, Medley JB, Krygier JJ, Yue S, Tanzer M. Engineering issues and wear performance of metal on metal hip implants. Clinical Orthopaedics and Related Research. 96-107. PMID 8981885 |
0.435 |
|
1996 |
Medley JB, Chan FW, Krygier JJ, Bobyn JD. Comparison of alloys and designs in a hip simulator study of metal on metal implants. Clinical Orthopaedics and Related Research. S148-59. PMID 8769332 |
0.372 |
|
1995 |
Bobyn JD, Jacobs JJ, Tanzer M, Urban RM, Aribindi R, Sumner DR, Turner TM, Brooks CE. The susceptibility of smooth implant surfaces to periimplant fibrosis and migration of polyethylene wear debris. Clinical Orthopaedics and Related Research. 21-39. PMID 7634577 |
0.378 |
|
1994 |
Bobyn JD, Tanzer M, Krygier JJ, Dujovne AR, Brooks CE. Concerns with modularity in total hip arthroplasty. Clinical Orthopaedics and Related Research. 27-36. PMID 8118986 |
0.412 |
|
1992 |
LaBerge M, Bobyn JD, Drouin G, Rivard CH. Evaluation of metallic personalized hemiarthroplasty: A canine patellofemoral model Journal of Biomedical Materials Research. 26: 239-254. PMID 1569116 DOI: 10.1002/Jbm.820260209 |
0.3 |
|
1990 |
LaBerge M, Bobyn JD, Rivard CH, Drouin G, Duval P. Study of soft tissue ingrowth into canine porous coated femoral implants designed for osteosarcomas management. Journal of Biomedical Materials Research. 24: 959-71. PMID 2398080 DOI: 10.1002/jbm.820240712 |
0.305 |
|
1988 |
Engh GA, Bobyn JD, Petersen TL. Radiographic and histologic study of porous coated tibial component fixation in cementless total knee arthroplasty. Orthopedics. 11: 725-31. PMID 3399443 |
0.352 |
|
1987 |
Bobyn JD, Engh CA, Glassman AH. Histologic analysis of a retrieved microporous-coated femoral prosthesis. A seven-year case report. Clinical Orthopaedics and Related Research. 303-10. PMID 3311518 |
0.319 |
|
1986 |
Buchert PK, Vaughn BK, Mallory TH, Engh CA, Bobyn JD. Excessive metal release due to loosening and fretting of sintered particles on porous-coated hip prostheses. Report of two cases. The Journal of Bone and Joint Surgery. American Volume. 68: 606-9. PMID 3957987 |
0.551 |
|
1980 |
Bobyn JD, Pilliar RM, Cameron HU, Weatherly GC. The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone. Clinical Orthopaedics and Related Research. 263-70. PMID 7428231 |
0.422 |
|
1980 |
Bobyn JD, Pilliar RM, Cameron HU, Weatherly GC, Kent GM. The effect of porous surface configuration on the tensile strength of fixation of implants by bone ingrowth. Clinical Orthopaedics and Related Research. 291-8. PMID 7408314 |
0.39 |
|
Show low-probability matches. |