Year |
Citation |
Score |
2015 |
McCall C, Rostosky R, Wiard RM, Inan OT, Giovangrandi L, Cuttino CM, Kovacs GT. Noninvasive pulse transit time measurement for arterial stiffness monitoring in microgravity. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2015: 6429-6432. PMID 26737764 DOI: 10.1109/EMBC.2015.7319864 |
0.485 |
|
2014 |
McCall C, Stuart Z, Wiard RM, Inan OT, Giovangrandi L, Cuttino CM, Kovacs GT. Standing ballistocardiography measurements in microgravity. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2014: 5180-3. PMID 25571160 DOI: 10.1109/EMBC.2014.6944792 |
0.504 |
|
2013 |
Wiard RM, Inan OT, Giovangrandi L, Cuttino CM, Kovacs GT. Preliminary results from standing ballistocardiography measurements in microgravity. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2013: 7290-3. PMID 24111428 DOI: 10.1109/EMBC.2013.6611241 |
0.507 |
|
2013 |
Inan OT, Pandia K, Giovangrandi L, Zamanian RT, Kovacs GT. A preliminary study investigating the quantification of beat-to-beat in seismocardiogram signals. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2013: 7286-9. PMID 24111427 DOI: 10.1109/EMBC.2013.6611240 |
0.532 |
|
2013 |
Pandia K, Inan OT, Kovacs GT. A frequency domain analysis of respiratory variations in the seismocardiogram signal. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2013: 6881-4. PMID 24111326 DOI: 10.1109/EMBC.2013.6611139 |
0.518 |
|
2013 |
Evander M, Ricco AJ, Morser J, Kovacs GT, Leung LL, Giovangrandi L. Microfluidic impedance cytometer for platelet analysis. Lab On a Chip. 13: 722-9. PMID 23282651 DOI: 10.1039/C2Lc40896A |
0.321 |
|
2013 |
Chen MQ, Wong J, Kuhl E, Giovangrandi L, Kovacs GT. Characterisation of electrophysiological conduction in cardiomyocyte co-cultures using co-occurrence analysis. Computer Methods in Biomechanics and Biomedical Engineering. 16: 185-97. PMID 21970595 DOI: 10.1080/10255842.2011.615310 |
0.333 |
|
2012 |
Giovangrandi L, Inan OT, Banerjee D, Kovacs GT. Preliminary results from BCG and ECG measurements in the heart failure clinic. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2012: 3780-3. PMID 23366751 DOI: 10.1109/EMBC.2012.6346790 |
0.514 |
|
2012 |
Pandia K, Inan OT, Kovacs GT, Giovangrandi L. Extracting respiratory information from seismocardiogram signals acquired on the chest using a miniature accelerometer. Physiological Measurement. 33: 1643-60. PMID 22986375 DOI: 10.1088/0967-3334/33/10/1643 |
0.564 |
|
2012 |
Dura B, Kovacs GT, Giovangrandi L. Spatiotemporally controlled cardiac conduction block using high-frequency electrical stimulation. Plos One. 7: e36217. PMID 22558389 DOI: 10.1371/Journal.Pone.0036217 |
0.341 |
|
2012 |
Dura B, Chen MQ, Inan OT, Kovacs GT, Giovangrandi L. High-frequency electrical stimulation of cardiac cells and application to artifact reduction. Ieee Transactions On Bio-Medical Engineering. 59: 1381-90. PMID 22345525 DOI: 10.1109/Tbme.2012.2188136 |
0.564 |
|
2012 |
Inan OT, Dookun Park, Giovangrandi L, Kovacs GT. Noninvasive measurement of physiological signals on a modified home bathroom scale. Ieee Transactions On Bio-Medical Engineering. 59: 2137-43. PMID 22318479 DOI: 10.1109/Tbme.2012.2186809 |
0.587 |
|
2011 |
Giovangrandi L, Inan OT, Wiard RM, Etemadi M, Kovacs GT. Ballistocardiography--a method worth revisiting. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2011: 4279-82. PMID 22255285 DOI: 10.1109/IEMBS.2011.6091062 |
0.511 |
|
2011 |
Inan OT, Park D, Kovacs GT, Giovangrandi L. Multi-signal electromechanical cardiovascular monitoring on a modified home bathroom scale. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2011: 2472-5. PMID 22254842 DOI: 10.1109/IEMBS.2011.6090686 |
0.529 |
|
2011 |
Inan OT, Marcu O, Sanchez ME, Bhattacharya S, Kovacs GT. A portable system for monitoring the behavioral activity of Drosophila. Journal of Neuroscience Methods. 202: 45-52. PMID 21907735 DOI: 10.1016/J.Jneumeth.2011.08.039 |
0.536 |
|
2011 |
Etemadi M, Inan OT, Giovangrandi L, Kovacs GT. Rapid assessment of cardiac contractility on a home bathroom scale. Ieee Transactions On Information Technology in Biomedicine : a Publication of the Ieee Engineering in Medicine and Biology Society. 15: 864-9. PMID 21843998 DOI: 10.1109/TITB.2011.2161998 |
0.479 |
|
2011 |
Wiard RM, Inan OT, Argyres B, Etemadi M, Kovacs GT, Giovangrandi L. Automatic detection of motion artifacts in the ballistocardiogram measured on a modified bathroom scale. Medical & Biological Engineering & Computing. 49: 213-20. PMID 21153058 DOI: 10.1007/S11517-010-0722-Y |
0.555 |
|
2010 |
Chen MQ, Whittington RH, Day PW, Kobilka BK, Giovangrandi L, Kovacs GT. A device for separated and reversible co-culture of cardiomyocytes. Biotechnology Progress. 26: 1164-71. PMID 20730771 DOI: 10.1002/Btpr.431 |
0.611 |
|
2010 |
Inan OT, Kovacs GT, Giovangrandi L. Evaluating the lower-body electromyogram signal acquired from the feet as a noise reference for standing ballistocardiogram measurements. Ieee Transactions On Information Technology in Biomedicine : a Publication of the Ieee Engineering in Medicine and Biology Society. 14: 1188-96. PMID 20371416 DOI: 10.1109/TITB.2010.2044185 |
0.531 |
|
2010 |
Inan OT, Etemadi M, Widrow B, Kovacs GT. Adaptive cancellation of floor vibrations in standing ballistocardiogram measurements using a seismic sensor as a noise reference. Ieee Transactions On Bio-Medical Engineering. 57: 722-7. PMID 19362900 DOI: 10.1109/Tbme.2009.2018831 |
0.547 |
|
2009 |
Chen MQ, Xie X, Wilson KD, Sun N, Wu JC, Giovangrandi L, Kovacs GT. Current-Controlled Electrical Point-Source Stimulation of Embryonic Stem Cells. Cellular and Molecular Bioengineering. 2: 625-635. PMID 20652088 DOI: 10.1007/S12195-009-0096-0 |
0.307 |
|
2009 |
Chen MQ, Yu J, Whittington RH, Wu JC, Kovacs GT, Giovangrandi L. Modeling conduction in host-graft interactions between stem cell grafts and cardiomyocytes. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2009: 6014-7. PMID 19964687 DOI: 10.1109/IEMBS.2009.5334024 |
0.542 |
|
2009 |
Inan OT, Etemadi M, Wiard RM, Kovacs GT, Giovangrandi L. Novel methods for estimating the ballistocardiogram signal using a simultaneously acquired electrocardiogram. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2009: 5344-47. PMID 19964385 DOI: 10.1109/IEMBS.2009.5333709 |
0.522 |
|
2009 |
Etemadi M, Inan OT, Wiard RM, Kovacs GT, Giovangrandi L. Non-invasive assessment of cardiac contractility on a weighing scale. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2009: 6773-6. PMID 19963690 DOI: 10.1109/IEMBS.2009.5332508 |
0.48 |
|
2009 |
Ouellette AL, Li JJ, Cooper DE, Ricco AJ, Kovacs GT. Evolving point-of-care diagnostics using up-converting phosphor bioanalytical systems. Analytical Chemistry. 81: 3216-21. PMID 19368339 DOI: 10.1021/Ac900475U |
0.515 |
|
2009 |
Inan OT, Etemadi M, Sanchez ME, Marcu O, Bhattacharya S, Kovacs GT. A miniaturized video system for monitoring the locomotor activity of walking Drosophila melanogaster in space and terrestrial settings. Ieee Transactions On Bio-Medical Engineering. 56: 522-4. PMID 19272912 DOI: 10.1109/Tbme.2008.2006018 |
0.54 |
|
2008 |
Inan OT, Etemadi M, Wiard RM, Kovacs GT, Giovangrandi L. Non-invasive measurement of Valsalva-induced hemodynamic changes on a bathroom scale ballistocardiograph. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2008: 674-7. PMID 19162745 DOI: 10.1109/IEMBS.2008.4649242 |
0.51 |
|
2008 |
Li JJ, Ouellette AL, Giovangrandi L, Cooper DE, Ricco AJ, Kovacs GT. Optical scanner for immunoassays with up-converting phosphorescent labels. Ieee Transactions On Bio-Medical Engineering. 55: 1560-71. PMID 18440902 DOI: 10.1109/Tbme.2007.914674 |
0.559 |
|
2008 |
Whittington RH, Kovacs GT. A discrete-time control algorithm applied to closed-loop pacing of HL-1 cardiomyocytes. Ieee Transactions On Bio-Medical Engineering. 55: 21-30. PMID 18232343 DOI: 10.1109/Tbme.2007.910641 |
0.617 |
|
2006 |
Whittington RH, Chen MQ, Giovangrandi L, Kovacs GT. Temporal resolution of stimulation threshold: a tool for electrophysiologic analysis. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 3891-4. PMID 17945812 DOI: 10.1109/IEMBS.2006.259332 |
0.582 |
|
2006 |
Inan OT, Giovangrandi L, Kovacs GT. Robust neural-network-based classification of premature ventricular contractions using wavelet transform and timing interval features. Ieee Transactions On Bio-Medical Engineering. 53: 2507-15. PMID 17153208 DOI: 10.1109/Tbme.2006.880879 |
0.524 |
|
2005 |
Whittington RH, Giovangrandi L, Kovacs GT. A closed-loop electrical stimulation system for cardiac cell cultures. Ieee Transactions On Bio-Medical Engineering. 52: 1261-70. PMID 16041989 DOI: 10.1109/Tbme.2005.847539 |
0.621 |
|
2005 |
Gilchrist KH, Giovangrandi L, Whittington RH, Kovacs GT. Sensitivity of cell-based biosensors to environmental variables. Biosensors & Bioelectronics. 20: 1397-406. PMID 15590295 DOI: 10.1016/J.Bios.2004.06.007 |
0.742 |
|
2001 |
Aravanis AM, DeBusschere BD, Chruscinski AJ, Gilchrist KH, Kobilka BK, Kovacs GT. A genetically engineered cell-based biosensor for functional classification of agents. Biosensors & Bioelectronics. 16: 571-7. PMID 11544051 DOI: 10.1016/S0956-5663(01)00171-3 |
0.66 |
|
2001 |
Gilchrist KH, Barker VN, Fletcher LE, DeBusschere BD, Ghanouni P, Giovangrandi L, Kovacs GT. General purpose, field-portable cell-based biosensor platform. Biosensors & Bioelectronics. 16: 557-64. PMID 11544049 DOI: 10.1016/S0956-5663(01)00169-5 |
0.657 |
|
1998 |
Pancrazio JJ, Bey PP, Loloee A, Manne S, Chao HC, Howard LL, Gosney WM, Borkholder DA, Kovacs GT, Manos P, Cuttino DS, Stenger DA. Description and demonstration of a CMOS amplifier-based-system with measurement and stimulation capability for bioelectrical signal transduction. Biosensors & Bioelectronics. 13: 971-9. PMID 9839386 DOI: 10.1016/S0956-5663(98)00006-2 |
0.413 |
|
1997 |
Borkholder DA, Bao J, Maluf NI, Perl ER, Kovacs GT. Microelectrode arrays for stimulation of neural slice preparations. Journal of Neuroscience Methods. 77: 61-6. PMID 9402558 DOI: 10.1016/S0165-0270(97)00112-X |
0.324 |
|
1997 |
Della Santina CC, Kovacs GT, Lewis ER. Multi-unit recording from regenerated bullfrog eighth nerve using implantable silicon-substrate microelectrodes. Journal of Neuroscience Methods. 72: 71-86. PMID 9128171 DOI: 10.1016/S0165-0270(96)00159-8 |
0.322 |
|
1997 |
Yee GM, Maluf NI, Hing PA, Albin M, Kovacs GT. Miniature spectrometers for biochemical analysis Sensors and Actuators a: Physical. 58: 61-66. DOI: 10.1016/S0924-4247(97)80225-7 |
0.74 |
|
1997 |
Suh JW, Glander SF, Darling RB, Storment CW, Kovacs GT. Organic thermal and electrostatic ciliary microactuator array for object manipulation Sensors and Actuators a: Physical. 58: 51-60. DOI: 10.1016/S0924-4247(97)80224-5 |
0.542 |
|
1997 |
Kewley DT, Hills MD, Borkholder DA, Opris IE, Maluf NI, Storment CW, Bower JM, Kovacs GT. Plasma-etched neural probes Sensors and Actuators a: Physical. 58: 27-35. DOI: 10.1016/S0924-4247(97)80221-X |
0.703 |
|
1996 |
Reay RJ, Flannery AF, Storment CW, Kounaves SP, Kovacs GT. Microfabricated electrochemical analysis system for heavy metal detection Sensors and Actuators B: Chemical. 34: 450-455. DOI: 10.1016/S0925-4005(97)80018-4 |
0.305 |
|
1996 |
Maluf N, Reay R, Kovacs G. High-voltage devices and circuits fabricated using foundry CMOS for use with electrostatic MEM actuators Sensors and Actuators a: Physical. 52: 187-192. DOI: 10.1016/0924-4247(96)80147-6 |
0.301 |
|
1996 |
Klaassen EH, Reay RJ, Kovacs GT. Diode-based thermal r.m.s. converter with on-chip circuitry fabricated using CMOS technology Sensors and Actuators a: Physical. 52: 33-40. DOI: 10.1016/0924-4247(96)80122-1 |
0.305 |
|
1996 |
Honer KA, Maluf NI, Martinez E, Kovacs GT. Characterizing deflectable microstructures via a high-resolution laser-based measurement system Sensors and Actuators a: Physical. 52: 12-17. DOI: 10.1016/0924-4247(96)80119-1 |
0.708 |
|
1995 |
Jackson D, Kane BJ, Monroe S, Li J, Storment CW, Kovacs GT, Tanelian DL. A feedback controlled silicon microprobe for quantitative mechanical stimulation of nerve and tissue. Journal of Neuroscience Methods. 60: 157-63. PMID 8544475 DOI: 10.1016/0165-0270(95)00007-H |
0.322 |
|
1995 |
Kane BJ, Storment CW, Crowder SW, Tanelian DL, Kovacs GT. Force-sensing microprobe for precise stimulation of mechanosensitive tissues. Ieee Transactions On Bio-Medical Engineering. 42: 745-50. PMID 7642187 DOI: 10.1109/10.398634 |
0.321 |
|
1995 |
Opris I, Kovacs G. Large-signal subthreshold CMOS transconductance amplifier Electronics Letters. 31: 718. DOI: 10.1049/El:19950504 |
0.351 |
|
1994 |
Maluf NI, McNutt EL, Monroe S, Tanelian DL, Kovacs GT. A thermal signal generator probe for the study of neural thermal transduction. Ieee Transactions On Bio-Medical Engineering. 41: 649-55. PMID 7927385 DOI: 10.1109/10.301731 |
0.309 |
|
1993 |
Martinoia S, Bove M, Carlini G, Ciccarelli C, Grattarola M, Storment C, Kovacs G. A general-purpose system for long-term recording from a microelectrode array coupled to excitable cells. Journal of Neuroscience Methods. 48: 115-21. PMID 8377513 DOI: 10.1016/S0165-0270(05)80013-5 |
0.309 |
|
1991 |
Liang DH, Kovacs GT, Storment CW, White RL. A method for evaluating the selectivity of electrodes implanted for nerve simulation. Ieee Transactions On Bio-Medical Engineering. 38: 443-9. PMID 1874526 DOI: 10.1109/10.81563 |
0.302 |
|
Show low-probability matches. |