Year |
Citation |
Score |
2012 |
Connor DM, Cole EB, Zhong Z, Parham CA, Pisano ED. Preliminary performance measurements from a second generation diffraction enhanced imaging system Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8313. DOI: 10.1117/12.913280 |
0.729 |
|
2011 |
Connor DM, Zhong Z, Foda HD, Wiebe S, Parham CA, Dilmanian FA, Cole EB, Pisano ED. Diffraction enhanced imaging of a rat model of gastric acid aspiration pneumonitis. Academic Radiology. 18: 1515-21. PMID 21958600 DOI: 10.1016/J.Acra.2011.08.005 |
0.639 |
|
2011 |
Connor D, Cole E, Zhong Z, Dilmanian F, Wiebe S, Parham C, Pisano E. SU-C-220-06: Comparison of the Absorption Coefficient and Diffraction Enhanced Imagingˈˈs Apparent Absorption Coefficient of Lung Tissue Medical Physics. 38: 3380-3380. DOI: 10.1118/1.3611512 |
0.599 |
|
2011 |
Connor DM, Pisano ED, Cole EB, Zhong Z, Dilmanian FA, Parham CA, Bravin A, Coan P, Fernández M, Keyriläinen J, Suortti P. Translation of synchrotron-based research into the clinic: Assessing the current clinical potential of diffraction enhanced imaging Synchrotron Radiation News. 24: 29-33. DOI: 10.1080/08940886.2011.567166 |
0.695 |
|
2010 |
Faulconer LS, Parham CA, Connor DM, Kuzmiak C, Koomen M, Lee Y, Cho KR, Rafoth J, Livasy CA, Kim E, Zeng D, Cole E, Zhong Z, Pisano ED. Effect of breast compression on lesion characteristic visibility with diffraction-enhanced imaging. Academic Radiology. 17: 433-40. PMID 20036586 DOI: 10.1016/J.Acra.2009.10.020 |
0.706 |
|
2009 |
Muehleman C, Li J, Connor D, Parham C, Pisano E, Zhong Z. Diffraction-enhanced imaging of musculoskeletal tissues using a conventional x-ray tube. Academic Radiology. 16: 918-23. PMID 19580954 DOI: 10.1016/J.Acra.2009.04.006 |
0.677 |
|
2009 |
Kao T, Connor D, Dilmanian FA, Faulconer L, Liu T, Parham C, Pisano ED, Zhong Z. Characterization of diffraction-enhanced imaging contrast in breast cancer. Physics in Medicine and Biology. 54: 3247-56. PMID 19420420 DOI: 10.1088/0031-9155/54/10/019 |
0.691 |
|
2009 |
Parham C, Zhong Z, Connor DM, Chapman LD, Pisano ED. Design and implementation of a compact low-dose diffraction enhanced medical imaging system. Academic Radiology. 16: 911-7. PMID 19375952 DOI: 10.1016/J.Acra.2009.02.007 |
0.706 |
|
2008 |
Zhong Z, Bennett D, Chapman D, Chen J, Connor D, Dilmanian A, Faulconer L, Kao T, Leskovjan AC, Li J, Liu T, Miller LM, Muehleman C, Parham C, Pisano E, et al. Probing Alzheimer's Disease Pathology and Early Detection at the NSLS with Infrared, XRF, and DEI Synchrotron Radiation News. 21: 11-16. DOI: 10.1080/08940880802123035 |
0.653 |
|
2007 |
Young LW, Parham C, Zhong Z, Chapman D, Reaney MJ. Non-destructive diffraction enhanced imaging of seeds. Journal of Experimental Botany. 58: 2513-23. PMID 17595197 DOI: 10.1093/Jxb/Erm116 |
0.47 |
|
2007 |
Connor D, Dilmanian FA, Parham C, Kao T, Zhong Z. Energy and dose considerations for diffraction enhanced CT in small animal studies Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6510. DOI: 10.1117/12.710309 |
0.474 |
|
2007 |
Kao T, Liu C, Yu X, Young L, Connor D, Dilmanian A, Parham C, Reaney M, Zhong Z. Characterization of diffraction enhanced imaging contrast in plants Nuclear Instruments and Methods in Physics Research Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 582: 208-211. DOI: 10.1016/J.Nima.2007.08.137 |
0.455 |
|
2007 |
Hasnah MO, Zhong Z, Parham C, Zhang H, Chapman D. Compositional images from the Diffraction Enhanced Imaging technique Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 572: 953-957. DOI: 10.1016/J.Nima.2006.11.066 |
0.617 |
|
2006 |
Kelly ME, Beavis RC, Fourney DR, Schültke E, Parham C, Juurlink BH, Zhong Z, Chapman LD. Diffraction-enhanced imaging of the rat spine. Canadian Association of Radiologists Journal = Journal L'Association Canadienne Des Radiologistes. 57: 204-10. PMID 17128887 |
0.557 |
|
2006 |
Wernick MN, Yang Y, Mondal I, Chapman D, Hasnah M, Parham C, Pisano E, Zhong Z. Computation of mass-density images from x-ray refraction-angle images. Physics in Medicine and Biology. 51: 1769-78. PMID 16552103 DOI: 10.1088/0031-9155/51/7/009 |
0.678 |
|
2006 |
Wernick MN, Brankov JG, Chapman D, Yang Y, Khelashvili G, Anastasio MA, Zhong Z, Parham C, Li J, Muehleman C. Progress in multiple-image radiography Proceedings of Spie - the International Society For Optical Engineering. 6065. DOI: 10.1117/12.658076 |
0.581 |
|
2005 |
Hasnah MO, Parham C, Pisano ED, Zhong Z, Oltulu O, Chapman D. Mass density images from the diffraction enhanced imaging technique Medical Physics. 32: 549-552. PMID 15789601 DOI: 10.1118/1.1852794 |
0.707 |
|
2004 |
Kiss MZ, Sayers DE, Zhong Z, Parham C, Pisano ED. Improved image contrast of calcifications in breast tissue specimens using diffraction enhanced imaging. Physics in Medicine and Biology. 49: 3427-39. PMID 15379023 DOI: 10.1088/0031-9155/49/15/008 |
0.756 |
|
2002 |
Zhong Z, Chapman D, Connor D, Dilmanian A, Gmur N, Hasnah M, Johnston RE, Kiss MZ, Li J, Muehleman C, Oltulu O, Parham C, Pisano E, Rigon L, Sayers D, et al. Diffraction enhanced imaging of soft tissues Synchrotron Radiation News. 15: 27-34. DOI: 10.1080/08940880208602986 |
0.679 |
|
2000 |
Pisano ED, Parham CA. Digital mammography, sestamibi breast scintigraphy, and positron emission tomography breast imaging. Radiologic Clinics of North America. 38: 861-9, x. PMID 10943283 DOI: 10.1016/S0033-8389(05)70206-2 |
0.669 |
|
Low-probability matches (unlikely to be authored by this person) |
2023 |
Selby HM, Mukherjee P, Parham C, Malik SB, Gevaert O, Napel S, Shah RP. Performance of alternative manual and automated deep learning segmentation techniques for the prediction of benign and malignant lung nodules. Journal of Medical Imaging (Bellingham, Wash.). 10: 044006. PMID 37564098 DOI: 10.1117/1.JMI.10.4.044006 |
0.126 |
|
2018 |
Ibrahim AE, Adelman DM, Parham C, Hong Z, Villa M, Chahine FM, Ghieh FM. The External Jugular Vein Used as Recipient Vessel in Head and Neck Free Flap Reconstruction: Outcomes Compared to the Internal Jugular Vein. The Journal of Craniofacial Surgery. PMID 30394970 DOI: 10.1097/SCS.0000000000004873 |
0.051 |
|
1998 |
Wintemute GJ, Parham CA, Wright MA, Beaumont JJ, Drake CM. Weapons of choice: previous criminal history, later criminal activity, and firearm preference among legally authorized young adult purchasers of handguns. The Journal of Trauma. 44: 155-60. PMID 9464765 DOI: 10.1097/00005373-199801000-00021 |
0.04 |
|
1999 |
Wintemute GJ, Wright MA, Parham CA, Drake CM, Beaumont JJ. Denial of handgun purchase: A description of the affected population and a controlled study of their handgun preferences Journal of Criminal Justice. 27: 21-31. |
0.036 |
|
1999 |
Wintemute GJ, Parham CA, Beaumont JJ, Wright M, Drake C. Mortality among recent purchasers of handguns. The New England Journal of Medicine. 341: 1583-9. PMID 10564689 DOI: 10.1056/Nejm199911183412106 |
0.033 |
|
1998 |
Wintemute GJ, Wright MA, Parham CA, Drake CM, Beaumont JJ. Criminal activity and assault-type handguns: a study of young adults. Annals of Emergency Medicine. 32: 44-50. PMID 9656948 DOI: 10.1016/S0196-0644(98)70098-8 |
0.032 |
|
1998 |
Wintemute GJ, Drake CM, Beaumont JJ, Wright MA, Parham CA. Prior misdemeanor convictions as a risk factor for later violent and firearm-related criminal activity among authorized purchasers of handguns. Jama. 280: 2083-7. PMID 9875875 DOI: 10.1001/Jama.280.24.2083 |
0.032 |
|
1999 |
Fotis JJ, Blackman PH, Wood JH, Wintemute GJ, Drake CM, Beaumont JJ, Wright MA, Parham CA, Cole TB. Violent criminal activity among handgun purchasers with prior misdemeanor convictions [1] (multiple letters) Journal of the American Medical Association. 282: 425-427. PMID 10442649 DOI: 10.1001/Jama.282.5.425 |
0.027 |
|
1977 |
Isa AM, Sanders BR, Parham CA. T-lymphocyte suppressor activity in the cytotoxic response to the teratocarcinoma 402AX of the mouse. Transplantation Proceedings. 9: 1167-9. PMID 301303 |
0.01 |
|
Hide low-probability matches. |