Year |
Citation |
Score |
2013 |
Chow EY, Morris MM, Irazoqui PP. Implantable RF medical devices: The benefits of high-speed communication and much greater communication distances in biomedical applications Ieee Microwave Magazine. 14: 64-73. DOI: 10.1109/Mmm.2013.2248586 |
0.727 |
|
2013 |
Chow E, Joshi H, Wilats A, Thompson D, Cotton K, Nair S, Warren C, Tomayko B, Adkins A, Shen A, Morris M, Byerman B. Commercial development of RF medical implantable devices 2013 Ieee Mtt-S International Microwave Workshop Series On Rf and Wireless Technologies For Biomedical and Healthcare Applications, Imws-Bio 2013 - Proceedings. DOI: 10.1109/IMWS-BIO.2013.6756251 |
0.452 |
|
2012 |
Chlebowski AL, Chow EY, Ellison C, Irazoqui PP. Integrated LTCC packaging for use in biomedical devices. Bio-Medical Materials and Engineering. 22: 361-72. PMID 23114465 DOI: 10.3233/Bme-2012-0725 |
0.702 |
|
2011 |
Chow EY, Yang CL, Ouyang Y, Chlebowski AL, Irazoqui PP, Chappell WJ. Wireless powering and the study of RF propagation through ocular tissue for development of implantable sensors Ieee Transactions On Antennas and Propagation. 59: 2379-2387. DOI: 10.1109/Tap.2011.2144551 |
0.678 |
|
2010 |
Chow EY, Chlebowski AL, Irazoqui PP. A Miniature-Implantable RF-Wireless Active Glaucoma Intraocular Pressure Monitor. Ieee Transactions On Biomedical Circuits and Systems. 4: 340-9. PMID 23850751 DOI: 10.1109/Tbcas.2010.2081364 |
0.713 |
|
2010 |
Kahn AR, Chow EY, Abdel-Latief O, Irazoqui PP. Low-power, high data rate transceiver system for implantable prostheses. International Journal of Telemedicine and Applications. 2010: 563903. PMID 21317982 DOI: 10.1155/2010/563903 |
0.674 |
|
2010 |
Chow EY, Ha D, Lin TY, Devries WN, John SW, Chappell WJ, Irazoqui PP. Sub-cubic millimeter intraocular pressure monitoring implant to enable genetic studies on pressure-induced neurodegeneration. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2010: 6429-32. PMID 21096710 DOI: 10.1109/IEMBS.2010.5627324 |
0.59 |
|
2010 |
Chow EY, Chlebowski AL, Chakraborty S, Chappell WJ, Irazoqui PP. Fully wireless implantable cardiovascular pressure monitor integrated with a medical stent. Ieee Transactions On Bio-Medical Engineering. 57: 1487-96. PMID 20172781 DOI: 10.1109/Tbme.2010.2041058 |
0.676 |
|
2010 |
Chow EY, Chakraborty S, Chappell WJ, Irazoqui PP. Mixed-signal integrated circuits for self-contained sub-cubic millimeter biomedical implants Digest of Technical Papers - Ieee International Solid-State Circuits Conference. 53: 236-237. DOI: 10.1109/ISSCC.2010.5433933 |
0.609 |
|
2009 |
Chow EY, Beier BL, Francino A, Chappell WJ, Irazoqui PP. Toward an implantable wireless cardiac monitoring platform integrated with an FDA-approved cardiovascular stent. Journal of Interventional Cardiology. 22: 479-87. PMID 19807844 DOI: 10.1111/J.1540-8183.2009.00483.X |
0.713 |
|
2009 |
Jaroch DB, Ward MP, Chow EY, Rickus JL, Irazoqui PP. Magnetic insertion system for flexible electrode implantation. Journal of Neuroscience Methods. 183: 213-22. PMID 19596378 DOI: 10.1016/J.Jneumeth.2009.07.001 |
0.64 |
|
2009 |
Chow EY, Ouyang Y, Beier B, Chappell WJ, Irazoqui PP. Evaluation of cardiovascular stents as antennas for implantable wireless applications Ieee Transactions On Microwave Theory and Techniques. 57: 2523-2532. DOI: 10.1109/Tmtt.2009.2029954 |
0.716 |
|
2009 |
Chow EY, Beier B, Ouyang Y, Chappell WJ, Irazoqui PP. High frequency transcutaneous transmission using stents configured as a dipole radiator for cardiovascular implantable devices Ieee Mtt-S International Microwave Symposium Digest. 1317-1320. DOI: 10.1109/MWSYM.2009.5165947 |
0.716 |
|
2008 |
Chow EY, Yang CL, Chlebowski A, Moon S, Chappell WJ, Irazoqui PP. Implantable wireless telemetry boards for in Vivo transocular transmission Ieee Transactions On Microwave Theory and Techniques. 56: 3200-3208. DOI: 10.1109/Tmtt.2008.2007338 |
0.745 |
|
2007 |
Chow EY, Kahn A, Irazoqui PP. High data-rate 6.7 GHz wireless ASIC transmitter for neural prostheses. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2007: 6581-4. PMID 18003533 DOI: 10.1109/IEMBS.2007.4353867 |
0.589 |
|
Show low-probability matches. |