Year |
Citation |
Score |
2019 |
Brodnick SK, Ness JP, Richner TJ, Thongpang S, Novello J, Hayat M, Cheng KP, Krugner-Higby L, Suminski AJ, Ludwig KA, Williams JC. μECoG Recordings Through a Thinned Skull. Frontiers in Neuroscience. 13: 1017. PMID 31632232 DOI: 10.3389/Fnins.2019.01017 |
0.591 |
|
2019 |
Richner TJ, Brodnick SK, Thongpang S, Sandberg AA, Krugner-Higby L, Williams JC. Phase relationship between micro-electrocorticography and cortical neurons. Journal of Neural Engineering. PMID 31318702 DOI: 10.1088/1741-2552/Ab335B |
0.543 |
|
2018 |
Nimbalkar S, Castagnola E, Balasubramani A, Scarpellini A, Samejima S, Khorasani A, Boissenin A, Thongpang S, Moritz C, Kassegne S. Ultra-Capacitive Carbon Neural Probe Allows Simultaneous Long-Term Electrical Stimulations and High-Resolution Neurotransmitter Detection. Scientific Reports. 8: 6958. PMID 29725133 DOI: 10.1038/S41598-018-25198-X |
0.43 |
|
2017 |
Pizarro R, Richner T, Brodnick S, Thongpang S, Williams J, Van Veen B. Estimating cortical column sensory networks in rodents from micro-Electrocorticograph (μECoG) recordings. Neuroimage. PMID 28951350 DOI: 10.1016/J.Neuroimage.2017.09.043 |
0.578 |
|
2016 |
Park DW, Brodnick SK, Ness JP, Atry F, Krugner-Higby L, Sandberg A, Mikael S, Richner TJ, Novello J, Kim H, Baek DH, Bong J, Frye ST, Thongpang S, Swanson KI, et al. Fabrication and utility of a transparent graphene neural electrode array for electrophysiology, in vivo imaging, and optogenetics. Nature Protocols. 11: 2201-2222. PMID 27735935 DOI: 10.1038/Nprot.2016.127 |
0.607 |
|
2014 |
Kimtan T, Thupmongkol J, Williams JC, Thongpang S. Printable and transparent micro-electrocorticography (μECoG) for optogenetic applications. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2014: 482-5. PMID 25570001 DOI: 10.1109/EMBC.2014.6943633 |
0.603 |
|
2014 |
Park DW, Schendel AA, Mikael S, Brodnick SK, Richner TJ, Ness JP, Hayat MR, Atry F, Frye ST, Pashaie R, Thongpang S, Ma Z, Williams JC. Graphene-based carbon-layered electrode array technology for neural imaging and optogenetic applications. Nature Communications. 5: 5258. PMID 25327513 DOI: 10.1038/Ncomms6258 |
0.647 |
|
2014 |
Krakova Y, Tajalli H, Thongpang S, Derafshi Z, Ban T, Rahmani S, Selner AN, Al-Tarouti A, Williams JC, Hetling JR. Spatial differences in corneal electroretinogram potentials measured in rat with a contact lens electrode array. Documenta Ophthalmologica. Advances in Ophthalmology. 129: 151-66. PMID 25266461 DOI: 10.1007/S10633-014-9459-5 |
0.533 |
|
2014 |
Schendel AA, Nonte MW, Vokoun C, Richner TJ, Brodnick SK, Atry F, Frye S, Bostrom P, Pashaie R, Thongpang S, Eliceiri KW, Williams JC. The effect of micro-ECoG substrate footprint on the meningeal tissue response. Journal of Neural Engineering. 11: 046011. PMID 24941335 DOI: 10.1088/1741-2560/11/4/046011 |
0.588 |
|
2014 |
Richner TJ, Thongpang S, Brodnick SK, Schendel AA, Falk RW, Krugner-Higby LA, Pashaie R, Williams JC. Optogenetic micro-electrocorticography for modulating and localizing cerebral cortex activity. Journal of Neural Engineering. 11: 016010. PMID 24445482 DOI: 10.1088/1741-2560/11/1/016010 |
0.565 |
|
2013 |
Schendel AA, Thongpang S, Brodnick SK, Richner TJ, Lindevig BD, Krugner-Higby L, Williams JC. A cranial window imaging method for monitoring vascular growth around chronically implanted micro-ECoG devices. Journal of Neuroscience Methods. 218: 121-30. PMID 23769960 DOI: 10.1016/J.Jneumeth.2013.06.001 |
0.591 |
|
2013 |
Williams JJ, Rouse AG, Thongpang S, Williams JC, Moran DW. Differentiating closed-loop cortical intention from rest: building an asynchronous electrocorticographic BCI. Journal of Neural Engineering. 10: 046001. PMID 23715295 DOI: 10.1088/1741-2560/10/4/046001 |
0.482 |
|
2011 |
Thongpang S, Richner TJ, Brodnick SK, Schendel A, Kim J, Wilson JA, Hippensteel J, Krugner-Higby L, Moran D, Ahmed AS, Neimann D, Sillay K, Williams JC. A micro-electrocorticography platform and deployment strategies for chronic BCI applications. Clinical Eeg and Neuroscience. 42: 259-65. PMID 22208124 DOI: 10.1177/155005941104200412 |
0.659 |
|
2011 |
Selner AN, Ban T, Williams J, Thongpang S, Hetling JR. Novel contact lens electrode array for multi-electrode electroretinography (meERG) 2011 Ieee 37th Annual Northeast Bioengineering Conference, Nebec 2011. DOI: 10.1109/NEBC.2011.5778713 |
0.427 |
|
2009 |
Wilks SJ, Koivuniemi AS, Thongpang S, Williams JC, Otto KJ. Evaluation of micro-electrocorticographic electrodes for electrostimulation. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2009: 5510-3. PMID 19964123 DOI: 10.1109/IEMBS.2009.5333178 |
0.589 |
|
2009 |
Kim J, Richner TJ, Thongpang S, Sillay KA, Niemann DB, Ahmed AS, Krugner-Higby LA, Williams JC. Flexible thin film electrode arrays for minimally-invasive neurological monitoring. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2009: 5506-9. PMID 19964122 DOI: 10.1109/IEMBS.2009.5333177 |
0.634 |
|
Show low-probability matches. |