Kim S. Schairer, Ph.D. - Publications

Affiliations: 
Communication Sciences and Disorders  University of Wisconsin, Madison, Madison, WI 
Area:
Psychoacoustics

31 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2023 Ryan DB, Eckert MA, Sellers EW, Schairer KS, McBee MT, Ridley EA, Smith SL. Performance Monitoring and Cognitive Inhibition during a Speech-in-Noise Task in Older Listeners. Seminars in Hearing. 44: 124-139. PMID 37122879 DOI: 10.1055/s-0043-1767695  0.34
2023 Feeney MP, Schairer KS, Putterman DB. Wideband Acoustic Reflex Measurement. Seminars in Hearing. 44: 84-92. PMID 36925659 DOI: 10.1055/s-0043-1763296  0.318
2018 Schairer K, Keefe DH, Fitzpatrick D, Putterman D, Kolberg E, Garinis A, Kurth M, McGregor K, Light A, Feeney MP. Wideband transient otoacoustic emissions in ears with normal hearing and sensorineural hearing loss The Journal of the Acoustical Society of America. 144: 1834-1834. DOI: 10.1121/1.5068081  0.353
2018 Feeney MP, Schairer K, Keefe DH, Fitzpatrick D, Putterman D, Garinis A, Kurth M, Kolberg E, McGregor K, Light A. Comparison of wideband and clinical acoustic reflex thresholds in patients with normal hearing and sensorineural hearing loss The Journal of the Acoustical Society of America. 144: 1834-1834. DOI: 10.1121/1.5068080  0.408
2013 Neely ST, Stenfelt S, Schairer KS. Alternative ear-canal measures related to absorbance. Ear and Hearing. 34: 72S-77S. PMID 23900185 DOI: 10.1097/Aud.0B013E31829C7229  0.427
2013 Schairer KS, Feeney MP, Sanford CA. Acoustic reflex measurement. Ear and Hearing. 34: 43S-47S. PMID 23900179 DOI: 10.1097/Aud.0B013E31829C70D9  0.414
2011 Schairer KS, Morrison B, Szewczyk E, Fowler CG. Relationships among standard and wideband measures of middle ear function and distortion product otoacoustic emissions. Journal of the American Academy of Audiology. 22: 253-64. PMID 21756841 DOI: 10.3766/Jaaa.22.5.2  0.461
2011 Helfer TM, Jordan NN, Lee RB, Pietrusiak P, Cave K, Schairer K. Noise-induced hearing injury and comorbidities among postdeployment U.S. army soldiers: April 2003-june 2009 American Journal of Audiology. 20: 33-41. PMID 21474555 DOI: 10.1044/1059-0889(2011/10-0033)  0.363
2011 Keefe DH, Schairer KS. Specification of absorbed-sound power in the ear canal: application to suppression of stimulus frequency otoacoustic emissions. The Journal of the Acoustical Society of America. 129: 779-91. PMID 21361437 DOI: 10.1121/1.3531796  0.414
2009 Jesteadt W, Schairer KS, Nizami L, Khaddam S, Neely ST. Effects of external noise on detection of intensity increments. The Journal of the Acoustical Society of America. 126: 1941-53. PMID 19813806 DOI: 10.1121/1.3203994  0.766
2009 Keefe DH, Schairer KS, Ellison JC, Fitzpatrick DF, Jesteadt W. Use of stimulus-frequency otoacoustic emissions to investigate efferent and cochlear contributions to temporal overshoot. The Journal of the Acoustical Society of America. 125: 1595-604. PMID 19275317 DOI: 10.1121/1.3068443  0.709
2009 Schairer K, Morrison B, Steininger E, Fowler C. Comparison of measurements at ambient pressure on clinical immittance and wideband acoustic transfer function systems. The Journal of the Acoustical Society of America. 125: 2720-2720. DOI: 10.1121/1.4784440  0.401
2008 Schairer KS, Messersmith J, Jesteadt W. Use of psychometric-function slopes for forward-masked tones to investigate cochlear nonlinearity. The Journal of the Acoustical Society of America. 124: 2196-215. PMID 19062859 DOI: 10.1121/1.2968686  0.757
2007 Schairer KS, Ellison JC, Fitzpatrick D, Keefe DH. Wideband ipsilateral measurements of middle-ear muscle reflex thresholds in children and adults. The Journal of the Acoustical Society of America. 121: 3607-16. PMID 17552712 DOI: 10.1121/1.2722213  0.446
2006 Schairer KS, Ellison JC, Fitzpatrick D, Keefe DH. Use of stimulus-frequency otoacoustic emission latency and level to investigate cochlear mechanics in human ears. The Journal of the Acoustical Society of America. 120: 901-14. PMID 16938978 DOI: 10.1121/1.2214147  0.512
2005 Jesteadt W, Schairer KS, Neff DL. Effect of variability in level on forward masking and on increment detection. The Journal of the Acoustical Society of America. 118: 325-37. PMID 16119353 DOI: 10.1121/1.1928709  0.747
2005 Schairer KS, Keefe DH. Simultaneous recording of stimulus-frequency and distortion-product otoacoustic emission input-output functions in human ears. The Journal of the Acoustical Society of America. 117: 818-32. PMID 15759702 DOI: 10.1121/1.1850341  0.494
2005 Schairer KS, Messersmith J, Jesteadt W. Psychometric‐function slopes for forward‐masked tones in listeners with cochlear hearing loss The Journal of the Acoustical Society of America. 117: 2599-2599. DOI: 10.1121/1.4809469  0.761
2005 Schairer K, Gray L. Effects of Lead Exposure on Auditory Function and Perception Perspectives On Hearing and Hearing Disorders Research and Diagnostics. 9: 22. DOI: 10.1044/Hhd9.1.22  0.315
2004 Jesteadt W, Nizami L, Neely ST, Schairer KS. Effect of noise on the detection of intensity increments The Journal of the Acoustical Society of America. 115: 2600-2600. DOI: 10.1121/1.4784571  0.767
2003 Jesteadt W, Nizami L, Schairer KS. A measure of internal noise based on sample discrimination. The Journal of the Acoustical Society of America. 114: 2147-57. PMID 14587612 DOI: 10.1121/1.1610456  0.759
2003 Schairer KS, Fitzpatrick D, Keefe DH. Input-output functions for stimulus-frequency otoacoustic emissions in normal-hearing adult ears. The Journal of the Acoustical Society of America. 114: 944-66. PMID 12942975 DOI: 10.1121/1.1592799  0.548
2003 Schairer KS, Nizami L, Reimer JF, Jesteadt W. Effects of peripheral nonlinearity on psychometric functions for forward-masked tones. The Journal of the Acoustical Society of America. 113: 1560-73. PMID 12656391 DOI: 10.1121/1.1543933  0.762
2003 Schairer KS, Jesteadt W. Evidence of peripheral nonlinearity in psychometric function slopes of forward‐masked tones at 250 and 4000 Hz The Journal of the Acoustical Society of America. 113: 2226-2226. DOI: 10.1121/1.4808816  0.681
2002 Jesteadt W, Nizami L, Schairer KS. A measure of internal noise based on sample discrimination of level differences The Journal of the Acoustical Society of America. 112: 2299-2299. DOI: 10.1121/1.4779252  0.752
2002 Jesteadt W, Neely ST, Schairer KS. Estimating the form of the peripheral nonlinearity from slopes of psychometric functions in forward masking The Journal of the Acoustical Society of America. 111: 2358. DOI: 10.1121/1.4777930  0.657
2002 Schairer KS, Keefe DH. SFOAE input/output functions elicited by slightly off-frequency suppressors The Journal of the Acoustical Society of America. 111: 2356. DOI: 10.1121/1.4777919  0.369
2001 Schairer KS, Gould HJ, Pousson MA. Source generators of mismatch negativity to multiple deviant stimulus types. Brain Topography. 14: 117-30. PMID 11797810 DOI: 10.1023/A:1012992829580  0.379
2001 Schairer KS, Reimer JF, Jesteadt W. Psychometric functions for detection of tones following on‐ and off‐frequency forward maskers The Journal of the Acoustical Society of America. 109: 2464-2464. DOI: 10.1121/1.4744738  0.691
2001 Keefe DH, Schairer KS, Zhao F, Simmons JL. Measurement and interpretation of stimulus frequency otoacoustic emissions: Input/output functions and transient analyses The Journal of the Acoustical Society of America. 109: 2373-2374. DOI: 10.1121/1.4744355  0.448
2000 Schairer KS, Clukey C, Gould HJ. Distortion product otoacoustic emissions to single and simultaneous tone pairs. Journal of the American Academy of Audiology. 11: 411-7. PMID 11012236  0.481
Show low-probability matches.