Arnold Fontaine - Publications

Affiliations: 
Applied Research Laboratory Pennsylvania State University, State College, PA, United States 

18 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2008 Manning KB, Herbertson LH, Fontaine AA, Deutsch S. A detailed fluid mechanics study of tilting disk mechanical heart valve closure and the implications to blood damage. Journal of Biomechanical Engineering. 130: 041001. PMID 18601443 DOI: 10.1115/1.2927356  0.486
2008 Manning KB, Wivholm BD, Yang N, Fontaine AA, Deutsch S. Flow behavior within the 12-cc Penn State pulsatile pediatric ventricular assist device: an experimental study of the initial design. Artificial Organs. 32: 442-52. PMID 18422800 DOI: 10.1111/J.1525-1594.2008.00565.X  0.498
2007 Medvitz RB, Kreider JW, Manning KB, Fontaine AA, Deutsch S, Paterson EG. Development and validation of a computational fluid dynamics methodology for simulation of pulsatile left ventricular assist devices. Asaio Journal (American Society For Artificial Internal Organs : 1992). 53: 122-31. PMID 17413548 DOI: 10.1097/Mat.0B013E31802F37Dd  0.463
2006 Kreider JW, Manning KB, Oley LA, Fontaine AA, Deutsch S. The 50cc Penn State left ventricular assist device: a parametric study of valve orientation flow dynamics. Asaio Journal (American Society For Artificial Internal Organs : 1992). 52: 123-31. PMID 16557096 DOI: 10.1097/01.Mat.0000199750.89636.77  0.428
2005 Sohn K, Manning KB, Fontaine AA, Tarbell JM, Deutsch S. Acoustic and visual characteristics of cavitation induced by mechanical heart valves. The Journal of Heart Valve Disease. 14: 551-8. PMID 16116884  0.317
2005 Oley LA, Manning KB, Fontaine AA, Deutsch S. Off-design considerations of the 50cc Penn State Ventricular Assist Device. Artificial Organs. 29: 378-86. PMID 15854213 DOI: 10.1111/J.1525-1594.2005.29064.X  0.476
2005 Manning KB, Przybysz TM, Fontaine AA, Tarbell JM, Deutsch S. Near field flow characteristics of the Bjork-Shiley Monostrut valve in a modified single shot valve chamber. Asaio Journal (American Society For Artificial Internal Organs : 1992). 51: 133-8. PMID 15839436 DOI: 10.1097/01.Mat.0000153496.01522.E4  0.45
2004 Hochareon P, Manning KB, Fontaine AA, Tarbell JM, Deutsch S. Correlation of in vivo clot deposition with the flow characteristics in the 50 cc penn state artificial heart: a preliminary study. Asaio Journal (American Society For Artificial Internal Organs : 1992). 50: 537-42. PMID 15672785 DOI: 10.1097/01.Mat.0000145694.40637.A0  0.379
2004 Hochareon P, Manning KB, Fontaine AA, Tarbell JM, Deutsch S. Fluid dynamic analysis of the 50 cc Penn State artificial heart under physiological operating conditions using particle image velocimetry. Journal of Biomechanical Engineering. 126: 585-93. PMID 15648811 DOI: 10.1115/1.1798056  0.407
2004 Hochareon P, Manning KB, Fontaine AA, Tarbell JM, Deutsch S. Wall shear-rate estimation within the 50cc Penn State artificial heart using particle image velocimetry. Journal of Biomechanical Engineering. 126: 430-7. PMID 15543860 DOI: 10.1115/1.1784477  0.367
2003 Hochareon P, Manning KB, Fontaine AA, Deutsch S, Tarbell JM. Diaphragm motion affects flow patterns in an artificial heart. Artificial Organs. 27: 1102-9. PMID 14678424 DOI: 10.1111/J.1525-1594.2003.07206.X  0.369
2003 Manning KB, Kini V, Fontaine AA, Deutsch S, Tarbell JM. Regurgitant flow field characteristics of the St. Jude bileaflet mechanical heart valve under physiologic pulsatile flow using particle image velocimetry. Artificial Organs. 27: 840-6. PMID 12940907 DOI: 10.1046/J.1525-1594.2003.07194.X  0.532
2002 Bachmann C, Kini V, Deutsch S, Fontaine AA, Tarbell JM. Mechanisms of cavitation and the formation of stable bubbles on the Björk-Shiley Monostrut prosthetic heart valve. The Journal of Heart Valve Disease. 11: 105-13. PMID 11843495  0.312
2001 Kini V, Bachmann C, Fontaine A, Deutsch S, Tarbell JM. Integrating particle image velocimetry and laser Doppler velocimetry measurements of the regurgitant flow field past mechanical heart valves. Artificial Organs. 25: 136-45. PMID 11251479 DOI: 10.1046/J.1525-1594.2001.025002136.X  0.502
2000 Kini V, Bachmann C, Fontaine A, Deutsch S, Tarbell JM. Flow visualization in mechanical heart valves: occluder rebound and cavitation potential Annals of Biomedical Engineering. 28: 431-441. PMID 10870900 DOI: 10.1114/1.281  0.487
2000 Bachmann C, Hugo G, Rosenberg G, Deutsch S, Fontaine A, Tarbell JM. Fluid dynamics of a pediatric ventricular assist device. Artificial Organs. 24: 362-72. PMID 10848677 DOI: 10.1046/J.1525-1594.2000.06536.X  0.37
1997 Healy T, Fontaine A, Ellis J, Walton S, Yoganathan A. Visualization Of Regurgitant Flow Patterns Through The Hinge Of A 5: 1 Scale Model Of The Medtronic Parallel Bileaflet Heart Valve Asaio Journal. 43: 24. DOI: 10.1097/00002480-199703000-00085  0.399
1996 Burleson AC, N'Guyen T, Fontaine A, Levine RA, Yoganathan AP. A model based on dimensional analysis for noninvasive quantification of valvular regurgitation under confined and impinging conditions: in vitro pulsatile flow validation. Ultrasound in Medicine & Biology. 21: 899-911. PMID 7491745 DOI: 10.1016/0301-5629(95)00035-P  0.445
Show low-probability matches.