Year |
Citation |
Score |
2022 |
He X, Trigila C, Ariño-Estrada G, Roncali E. Potential of Depth-of-Interaction-Based Detection Time Correction in Cherenkov Emitter Crystals for TOF-PET. Ieee Transactions On Radiation and Plasma Medical Sciences. 7: 233-240. PMID 36994147 DOI: 10.1109/trpms.2022.3226950 |
0.343 |
|
2022 |
Taebi A, Janibek N, Goldman R, Pillai R, Vu CT, Roncali E. On the impact of injection distance to bifurcations on yttrium-90 distribution in liver cancer radioembolization. Journal of Vascular and Interventional Radiology : Jvir. PMID 35301128 DOI: 10.1016/j.jvir.2022.03.006 |
0.704 |
|
2021 |
Ariño-Estrada G, Roncali E, Selfridge AR, Du J, Glodo J, Shah KS, Cherry SR. Study of Čerenkov Light Emission in the Semiconductors TlBr and TlCl for TOF-PET. Ieee Transactions On Radiation and Plasma Medical Sciences. 5: 630-637. PMID 34485785 DOI: 10.1109/trpms.2020.3024032 |
0.505 |
|
2021 |
Taebi A, Berk S, Roncali E. Realistic boundary conditions in SimVascular through inlet catheter modeling. Bmc Research Notes. 14: 215. PMID 34103097 DOI: 10.1186/s13104-021-05631-7 |
0.71 |
|
2021 |
Trigila C, Moghe E, Roncali E. Technical note: Standalone application to generate custom reflectance Look-Up Table for advanced optical Monte Carlo simulation in GATE/Geant4. Medical Physics. PMID 33772816 DOI: 10.1002/mp.14863 |
0.325 |
|
2020 |
Meikle SR, Sossi V, Roncali E, Cherry SR, Banati R, Mankoff DA, Jones T, James ML, Sutcliffe J, Ouyang J, Petibon Y, Ma C, El Fakhri G, Surti S, Karp JS, et al. Quantitative PET in the 2020s: A Roadmap. Physics in Medicine and Biology. PMID 33339012 DOI: 10.1088/1361-6560/abd4f7 |
0.464 |
|
2020 |
Taebi A, Vu CT, Roncali E. Estimation of Yttrium-90 Distribution in Liver Radioembolization using Computational Fluid Dynamics and Deep Neural Networks. Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual International Conference. 2020: 4974-4977. PMID 33019103 DOI: 10.1109/EMBC44109.2020.9176328 |
0.736 |
|
2020 |
St James S, Bednarz B, Benedict S, Buchsbaum JC, Dewaraja Y, Frey E, Hobbs R, Grudzinski J, Roncali E, Sgouros G, Capala J, Xiao Y. Current Status of Radiopharmaceutical Therapy. International Journal of Radiation Oncology, Biology, Physics. PMID 32805300 DOI: 10.1016/J.Ijrobp.2020.08.035 |
0.32 |
|
2020 |
Taebi A, Pillai RM, Roudsari BS, Vu CT, Roncali E. Computational Modeling of the Liver Arterial Blood Flow for Microsphere Therapy: Effect of Boundary Conditions. Bioengineering (Basel, Switzerland). 7. PMID 32610459 DOI: 10.3390/Bioengineering7030064 |
0.726 |
|
2020 |
Taebi A, Vu CT, Roncali E. Multi-Scale Computational Fluid Dynamics Modeling for Personalized Liver Cancer Radioembolization Dosimetry. Journal of Biomechanical Engineering. PMID 32601676 DOI: 10.1115/1.4047656 |
0.74 |
|
2020 |
Roncali E, Taebi A, Foster C, Vu CT. Personalized Dosimetry for Liver Cancer Y-90 Radioembolization Using Computational Fluid Dynamics and Monte Carlo Simulation. Annals of Biomedical Engineering. PMID 32006268 DOI: 10.1007/S10439-020-02469-1 |
0.749 |
|
2019 |
Roncali E, Kwon SI, Jan S, Berg E, Cherry SR. Cerenkov light transport in scintillation crystals explained: realistic simulation with GATE. Biomedical Physics & Engineering Express. 5. PMID 33304614 DOI: 10.1088/2057-1976/ab0f93 |
0.548 |
|
2019 |
Kwon SI, Roncali E, Gola A, Paternoster G, Piemonte C, Cherry SR. Dual-ended readout of bismuth germanate to improve timing resolution in time-of-flight PET. Physics in Medicine and Biology. PMID 30978713 DOI: 10.1088/1361-6560/Ab18Da |
0.585 |
|
2019 |
Roncali E, Il Kwon S, Jan S, Berg E, Cherry SR. Cerenkov light transport in scintillation crystals explained: realistic simulation with GATE Biomedical Physics & Engineering Express. 5: 035033. DOI: 10.1088/2057-1976/Ab0F93 |
0.609 |
|
2017 |
Roncali E, Mosleh-Shirazi MA, Badano A. Modelling the transport of optical photons in scintillation detectors for diagnostic and radiotherapy imaging. Physics in Medicine and Biology. 62: R207-R235. PMID 28976914 DOI: 10.1088/1361-6560/Aa8B31 |
0.34 |
|
2017 |
Stockhoff M, Jan S, Dubois A, Cherry SR, Roncali E. Advanced optical simulation of scintillation detectors in GATE V8.0: first implementation of a reflectance model based on measured data. Physics in Medicine and Biology. 62: L1-L8. PMID 28452339 DOI: 10.1088/1361-6560/Aa7007 |
0.574 |
|
2017 |
Roncali E, Stockhoff M, Cherry SR. An integrated model of scintillator-reflector properties for advanced simulations of optical transport. Physics in Medicine and Biology. 62: 4811-4830. PMID 28398905 DOI: 10.1088/1361-6560/Aa6Ca5 |
0.58 |
|
2016 |
Kwon SI, Ferri A, Gola A, Berg E, Piemonte C, Cherry SR, Roncali E. Reaching 200-ps timing resolution in a time-of-flight and depth-of-interaction positron emission tomography detector using phosphor-coated crystals and high-density silicon photomultipliers. Journal of Medical Imaging (Bellingham, Wash.). 3: 043501. PMID 27921069 DOI: 10.1117/1.Jmi.3.4.043501 |
0.591 |
|
2016 |
Berg E, Roncali E, Hutchcroft W, Qi J, Cherry S. Improving depth, energy and timing estimation in PET detectors with deconvolution and maximum likelihood pulse shape discrimination. Ieee Transactions On Medical Imaging. PMID 27295658 DOI: 10.1109/Tmi.2016.2577539 |
0.582 |
|
2016 |
Berg E, Roncali E, Kapusta M, Du J, Cherry SR. A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography. Medical Physics. 43: 939. PMID 26843254 DOI: 10.1118/1.4940355 |
0.533 |
|
2015 |
Berg E, Roncali E, Cherry SR. Optimizing light transport in scintillation crystals for time-of-flight PET: an experimental and optical Monte Carlo simulation study. Biomedical Optics Express. 6: 2220-30. PMID 26114040 DOI: 10.1364/Boe.6.002220 |
0.607 |
|
2015 |
Du J, Schmall JP, Yang Y, Di K, Roncali E, Mitchell GS, Buckley S, Jackson C, Cherry SR. Evaluation of Matrix9 silicon photomultiplier array for small-animal PET. Medical Physics. 42: 585. PMID 25652479 DOI: 10.1118/1.4905088 |
0.713 |
|
2014 |
Schmall JP, Roncali E, Berg E, Viswanath V, Du J, Cherry SR. Timing properties of phosphor-coated polished LSO crystals. Physics in Medicine and Biology. 59: N139-51. PMID 25047008 DOI: 10.1088/0031-9155/59/15/N139 |
0.733 |
|
2014 |
Roncali E, Schmall JP, Viswanath V, Berg E, Cherry SR. Predicting the timing properties of phosphor-coated scintillators using Monte Carlo light transport simulation. Physics in Medicine and Biology. 59: 2023-39. PMID 24694727 DOI: 10.1088/0031-9155/59/8/2023 |
0.757 |
|
2014 |
Roncali E, Viswanath V, Cherry SR. Design considerations for DOI-encoding PET detectors using phosphor-coated crystals Ieee Transactions On Nuclear Science. 61: 67-73. DOI: 10.1109/Tns.2013.2293313 |
0.567 |
|
2013 |
Roncali E, Cherry SR. Simulation of light transport in scintillators based on 3D characterization of crystal surfaces. Physics in Medicine and Biology. 58: 2185-98. PMID 23475145 DOI: 10.1088/0031-9155/58/7/2185 |
0.595 |
|
2012 |
Roncali E, Phipps JE, Marcu L, Cherry SR. Pulse shape discrimination and classification methods for continuous depth of interaction encoding PET detectors. Physics in Medicine and Biology. 57: 6571-85. PMID 23010690 DOI: 10.1088/0031-9155/57/20/6571 |
0.555 |
|
2011 |
Roncali E, Cherry SR. Application of silicon photomultipliers to positron emission tomography. Annals of Biomedical Engineering. 39: 1358-77. PMID 21321792 DOI: 10.1007/S10439-011-0266-9 |
0.555 |
|
Show low-probability matches. |