Brian Clowers - Publications

Affiliations: 
Chemistry Washington State University, Pullman, WA, United States 

104 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2024 Cabrera ER, Schrader RL, Walker TE, Laganowsky A, Russell DH, Clowers BH. Nonlinear Frequency Modulation for Fourier Transform Ion Mobility Mass Spectrometry Improves Experimental Efficiency. International Journal of Mass Spectrometry. 497. PMID 38352886 DOI: 10.1016/j.ijms.2024.117197  0.434
2023 Schramm HM, Tamadate T, Hogan CJ, Clowers BH. Evaluation of Hydrogen-Deuterium Exchange during Transient Vapor Binding of MeOD with Model Peptide Systems Angiotensin II and Bradykinin. The Journal of Physical Chemistry. A. 127: 8849-8861. PMID 37827113 DOI: 10.1021/acs.jpca.3c04608  0.353
2023 Kinlein Z, Clowers BH. Evaluating dynamic traveling wave profiles for the enhancement of separation and sensitivity in traveling wave structures for lossless ion manipulations. Journal of Chromatography. A. 1706: 464207. PMID 37506460 DOI: 10.1016/j.chroma.2023.464207  0.387
2023 Greer C, Kinlein Z, Clowers BH. SLIM Tricks: Tools, Concepts, and Strategies for the Development of Planar Ion Guides. Journal of the American Society For Mass Spectrometry. 34: 1715-1723. PMID 37470389 DOI: 10.1021/jasms.3c00163  0.32
2023 Greer C, Clowers BH. Simultaneous Ion Swarm Profiling and Ion Mobility Measurement using Ion Cameras. Journal of the American Society For Mass Spectrometry. 34: 1545-1548. PMID 37403971 DOI: 10.1021/jasms.3c00131  0.472
2023 Naylor CN, Clowers BH, Schlottmann F, Solle N, Zimmermann S. Implementation of an Open-Source Multiplexing Ion Gate Control for High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS). Journal of the American Society For Mass Spectrometry. PMID 37276587 DOI: 10.1021/jasms.3c00013  0.456
2023 Cabrera ER, Laganowsky A, Clowers BH. FTflow: An Open-Source Python GUI for FT-IM-MS Experiments. Journal of the American Society For Mass Spectrometry. PMID 36854177 DOI: 10.1021/jasms.2c00352  0.364
2023 Schramm HM, Tamadate T, Hogan CJ, Clowers BH. Ion-neutral clustering alters gas-phase hydrogen-deuterium exchange rates. Physical Chemistry Chemical Physics : Pccp. 25: 4959-4968. PMID 36722872 DOI: 10.1039/d2cp04388b  0.308
2022 Butalewicz JP, Sanders JD, Clowers BH, Brodbelt JS. Improving Ion Mobility Mass Spectrometry of Proteins through Tristate Gating and Optimization of Multiplexing Parameters. Journal of the American Society For Mass Spectrometry. PMID 36469482 DOI: 10.1021/jasms.2c00274  0.52
2022 Cabrera ER, Clowers BH. Considerations for Generating Frequency Modulation Waveforms for Fourier Transform-Ion Mobility Experiments. Journal of the American Society For Mass Spectrometry. 33: 1858-1864. PMID 36066398 DOI: 10.1021/jasms.2c00168  0.475
2022 Reinecke T, Kenyon S, Gendreau K, Clowers BH. Characterization of a Modulated X-ray Source for Ion Mobility Spectrometry. Analytical Chemistry. PMID 36001409 DOI: 10.1021/acs.analchem.2c00729  0.41
2022 Sipe SN, Sanders JD, Reinecke T, Clowers BH, Brodbelt JS. Separation and Collision Cross Section Measurements of Protein Complexes Afforded by a Modular Drift Tube Coupled to an Orbitrap Mass Spectrometer. Analytical Chemistry. 94: 9434-9441. PMID 35736993 DOI: 10.1021/acs.analchem.2c01653  0.446
2022 Lee J, Clowers BH, Hogan CJ. Condensable Vapor Sorption by Low Charge State Protein Ions. Analytical Chemistry. PMID 35500255 DOI: 10.1021/acs.analchem.2c00357  0.387
2022 Kinlein ZR, Anderson GA, Clowers BH. Accelerating prototyping experiments for traveling wave structures for lossless ion manipulations. Talanta. 244: 123446. PMID 35397327 DOI: 10.1016/j.talanta.2022.123446  0.372
2022 Cabrera ER, Clowers BH. Synchronized Stepped Frequency Modulation for Multiplexed Ion Mobility Measurements. Journal of the American Society For Mass Spectrometry. PMID 35108007 DOI: 10.1021/jasms.1c00365  0.373
2021 McKenna KR, Clowers BH, Krishnamurthy R, Liotta CL, Fernández FM. Separations of Carbohydrates with Noncovalent Shift Reagents by Frequency-Modulated Ion Mobility-Orbitrap Mass Spectrometry. Journal of the American Society For Mass Spectrometry. PMID 34351139 DOI: 10.1021/jasms.1c00184  0.418
2021 Sanders JD, Butalewicz JP, Clowers BH, Brodbelt JS. Absorption Mode Fourier Transform Ion Mobility Mass Spectrometry Multiplexing Combined with Half-Window Apodization Windows Improves Resolution and Shortens Acquisition Times. Analytical Chemistry. PMID 34185992 DOI: 10.1021/acs.analchem.1c01427  0.401
2021 Morrison KA, Clowers BH. Non-contact detection of thiodiglycol vapors and associated degradation products using atmospheric flow tube mass spectrometry. The Analyst. 146: 3263-3272. PMID 33999081 DOI: 10.1039/d0an01793k  0.696
2021 Clowers BH, Cabrera E, Anderson G, Deng L, Moser K, Van Aken G, DeBord JD. Masked Multiplexed Separations to Enhance Duty Cycle for Structures for Lossless Ion Manipulations. Analytical Chemistry. 93: 5727-5734. PMID 33797223 DOI: 10.1021/acs.analchem.0c04799  0.415
2021 Ligare MR, Morrison KA, Hewitt MA, Reveles JU, Govind N, Hernandez H, Baker ES, Clowers BH, Laskin J, Johnson GE. Ion Mobility Spectrometry Characterization of the Intermediate Hydrogen-Containing Gold Cluster Au(PPh)H. The Journal of Physical Chemistry Letters. 2502-2508. PMID 33667097 DOI: 10.1021/acs.jpclett.0c03664  0.729
2021 Naylor CN, Clowers BH. Reevaluating the Role of Polarizability in Ion Mobility Spectrometry. Journal of the American Society For Mass Spectrometry. PMID 33533630 DOI: 10.1021/jasms.0c00338  0.362
2021 Davis EJ, Walker D, Gibney M, Clowers BH. Optical and mass spectral characterization of the electrospray ionization/corona discharge ionization interface. Talanta. 224: 121870. PMID 33379080 DOI: 10.1016/j.talanta.2020.121870  0.4
2020 Morrison KA, Valenzuela BR, Denis EH, Nims MK, Atkinson DA, Clowers BH, Ewing RG. Non-contact vapor detection of illicit drugs via atmospheric flow tube-mass spectrometry. The Analyst. PMID 32748910 DOI: 10.1039/d0an00691b  0.686
2020 Kwantwi-Barima P, Hogan CJ, Clowers BH. Probing Gas-Phase Clustering Thermodynamics with Ion Mobility-Mass Spectrometry: Association Energies of Phenylalanine Ions with Gas-Phase Alcohols. Journal of the American Society For Mass Spectrometry. PMID 32687705 DOI: 10.1021/jasms.0c00020  0.377
2020 Naylor CN, Ridgeway ME, Park MA, Clowers BH. Evaluation of Trapped Ion Mobility Spectrometry (TIMS) Source Conditions Using Benzylammonium Thermometer Ions. Journal of the American Society For Mass Spectrometry. PMID 32510214 DOI: 10.1021/jasms.0c00151  0.382
2020 Naylor CN, Reinecke T, Clowers BH. Assessing the Impact of Drift Gas Polarizability in Polyatomic Ion Mobility Experiments. Analytical Chemistry. PMID 32058698 DOI: 10.1021/acs.analchem.9b04468  0.392
2019 Naylor CN, Reinecke T, Ridgeway ME, Park MA, Clowers BH. Validation of Calibration Parameters for Trapped Ion Mobility Spectrometry. Journal of the American Society For Mass Spectrometry. 30: 2152-2162. PMID 31951735 DOI: 10.1021/jasms.8b06234  0.383
2019 Kwantwi-Barima P, Reinecke T, Clowers BH. Increased ion throughput using tristate ion-gate multiplexing. The Analyst. PMID 31595887 DOI: 10.1039/c9an01585j  0.406
2019 Naylor CN, Reinecke T, Ridgeway ME, Park MA, Clowers BH. Validation of Calibration Parameters for Trapped Ion Mobility Spectrometry. Journal of the American Society For Mass Spectrometry. PMID 31392697 DOI: 10.1007/s13361-019-02289-1  0.382
2019 Morrison KA, Bythell BJ, Clowers BH. Interrogating Proton Affinities of Organophosphonate Species Via Atmospheric Flow Tube Mass Spectrometry and Computational Methods. Journal of the American Society For Mass Spectrometry. PMID 30993636 DOI: 10.1007/S13361-019-02202-W  0.735
2019 Reinecke T, Davis AL, Clowers BH. Determination of Gas-Phase Ion Mobility Coefficients Using Voltage Sweep Multiplexing. Journal of the American Society For Mass Spectrometry. PMID 30989619 DOI: 10.1007/S13361-019-02182-X  0.822
2019 Kwantwi-Barima P, Hogan CJ, Clowers BH. Deducing Proton-Bound Heterodimer Association Energies from Shifts in Ion Mobility Arrival Time Distributions. The Journal of Physical Chemistry. A. 123: 2957-2965. PMID 30844278 DOI: 10.1021/acs.jpca.8b11183  0.424
2019 Gabelica V, Shvartsburg AA, Afonso C, Barran P, Benesch JLP, Bleiholder C, Bowers MT, Bilbao A, Bush MF, Campbell JL, Campuzano IDG, Causon T, Clowers BH, Creaser CS, De Pauw E, et al. Recommendations for reporting ion mobility Mass Spectrometry measurements. Mass Spectrometry Reviews. PMID 30707468 DOI: 10.1002/Mas.21585  0.404
2019 Morrison KA, Ewing RG, Clowers BH. Ambient vapor sampling and selective cluster formation for the trace detection of tributyl phosphate via atmospheric flow tube mass spectrometry. Talanta. 195: 683-690. PMID 30625601 DOI: 10.1016/J.Talanta.2018.11.115  0.709
2019 Morrison KA, Clowers BH. Fundamentals and applications of incorporating chromatographic separations with ion mobility-mass spectrometry Trac Trends in Analytical Chemistry. 119: 115625. DOI: 10.1016/J.Trac.2019.115625  0.763
2019 Reinecke T, Naylor CN, Clowers BH. Ion multiplexing: Maximizing throughput and signal to noise ratio for ion mobility spectrometry Trac Trends in Analytical Chemistry. 116: 340-345. DOI: 10.1016/J.TRAC.2019.03.014  0.388
2018 Davis AL, Reinecke T, Morrison KA, Clowers BH. Optimized Reconstruction Techniques for Multiplexed Dual-Gate Ion Mobility Mass Spectrometry Experiments. Analytical Chemistry. PMID 30561982 DOI: 10.1021/Acs.Analchem.8B04175  0.822
2018 Greene NZ, Wiley JL, Yu Z, Clowers BH, Craft RM. Cannabidiol modulation of antinociceptive tolerance to Δ-tetrahydrocannabinol. Psychopharmacology. PMID 30238130 DOI: 10.1007/S00213-018-5036-Z  0.496
2018 Yu Z, Miller HC, Puzon GJ, Clowers BH. Application of untargeted metabolomics for the detection of pathogenic Naegleria fowleri in an operational drinking water distribution system. Water Research. 145: 678-686. PMID 30212806 DOI: 10.1016/J.Watres.2018.09.003  0.529
2018 Poltash ML, McCabe JW, Shirzadeh M, Laganowsky A, Clowers BH, Russell DH. Fourier Transform-Ion Mobility-Orbitrap Mass Spectrometer: A Next-generation Instrument for Native Mass Spectrometry. Analytical Chemistry. PMID 30091588 DOI: 10.1021/Acs.Analchem.8B02463  0.497
2018 Opačić B, Hoffman NM, Gotlib ZP, Clowers BH, Reilly PTA. Using Digital Waveforms to Mitigate Solvent Clustering During Mass Filter Analysis of Proteins. Journal of the American Society For Mass Spectrometry. 29: 2081-2085. PMID 29987662 DOI: 10.1007/s13361-018-2012-0  0.324
2018 Morrison KA, Clowers BH. Characterization of Alkylphosphonic Acid Vapors Using Atmospheric Flow Tube-Ion Trap Mass Spectrometry. Rapid Communications in Mass Spectrometry : Rcm. PMID 29845656 DOI: 10.1002/Rcm.8177  0.724
2018 Morrison KA, Bendiak BK, Clowers BH. Assessment of Dimeric Metal-Glycan Adducts via Isotopic Labeling and Ion Mobility-Mass Spectrometry. Journal of the American Society For Mass Spectrometry. PMID 29802562 DOI: 10.1007/S13361-018-1982-2  0.77
2018 Davis AL, Clowers BH. Stabilization of gas-phase uranyl complexes enables rapid speciation using electrospray ionization and ion mobility-mass spectrometry. Talanta. 176: 140-150. PMID 28917733 DOI: 10.1016/J.Talanta.2017.07.090  0.821
2018 Reinecke T, Clowers BH. Implementation of a flexible, open-source platform for ion mobility spectrometry Hardwarex. 4: e00030. DOI: 10.1016/J.OHX.2018.E00030  0.395
2018 Opačić B, Hoffman NM, Clowers BH, Reilly PT. Impact of injection potential on measured ion response for digitally driven mass filters International Journal of Mass Spectrometry. 434: 1-6. DOI: 10.1016/J.IJMS.2018.08.009  0.305
2018 Davis AL, Clowers BH. Leveraging spectral sparsity to realize enhanced separation of gas-phase ion populations International Journal of Mass Spectrometry. 427: 141-150. DOI: 10.1016/J.Ijms.2017.11.008  0.811
2018 Yu Z, Huang M, Clowers BH. Comparative metabolite profiling of a metastatic and primary melanoma cell line using untargeted metabolomics: A case study Clinical Mass Spectrometry. 10: 16-24. DOI: 10.1016/J.Clinms.2018.08.001  0.545
2017 Morrison KA, Bendiak BK, Clowers BH. Enhanced Mixture Separations of Metal Adducted Tetrasaccharides Using Frequency Encoded Ion Mobility Separations and Tandem Mass Spectrometry. Journal of the American Society For Mass Spectrometry. 28: 664-677. PMID 31989822 DOI: 10.1021/jasms.8b05498  0.759
2017 Morrison KA, Clowers BH. Contemporary glycomic approaches using ion mobility-mass spectrometry. Current Opinion in Chemical Biology. 42: 119-129. PMID 29248736 DOI: 10.1016/J.Cbpa.2017.11.020  0.774
2017 Kelley MP, Davis A, Clowers B, Clark AE, Clark SB. Acceleration of metal-ligand complexation kinetics by electrospray ionization. The Analyst. PMID 29094733 DOI: 10.1039/C7An01142C  0.808
2017 Kwantwi-Barima P, Ouyang H, Hogan CJ, Clowers BH. Tuning Mobility Separation Factors of Chemical Warfare Agent Degradation Products via Selective Ion-Neutral Clustering. Analytical Chemistry. PMID 29058408 DOI: 10.1021/Acs.Analchem.7B03518  0.301
2017 Keelor JD, Zambrzycki S, Li A, Clowers BH, Fernandez FM. Atmospheric Pressure Drift Tube Ion Mobility-Orbitrap Mass Spectrometry: Initial Performance Characterization. Analytical Chemistry. PMID 29019648 DOI: 10.1021/Acs.Analchem.7B01866  0.48
2017 Britch SC, Wiley JL, Yu Z, Clowers BH, Craft RM. Cannabidiol-Δ(9)-tetrahydrocannabinol interactions on acute pain and locomotor activity. Drug and Alcohol Dependence. 175: 187-197. PMID 28445853 DOI: 10.1016/J.Drugalcdep.2017.01.046  0.497
2017 Morrison KA, Clowers BH. Differential Fragmentation of Mobility-Selected Glycans via Ultraviolet Photodissociation and Ion Mobility-Mass Spectrometry. Journal of the American Society For Mass Spectrometry. PMID 28421405 DOI: 10.1007/S13361-017-1621-3  0.777
2017 Yu Z, Miller HC, Puzon GJ, Clowers BH. Development of Untargeted Metabolomics Methods for the Rapid Detection of Pathogenic Naegleria fowleri. Environmental Science & Technology. PMID 28290675 DOI: 10.1021/Acs.Est.6B05969  0.543
2017 Liu W, Davis AL, Siems WF, Yin DL, Clowers BH, Hill HH. Ambient pressure inverse ion mobility spectrometry coupled to mass spectrometry. Analytical Chemistry. PMID 28192980 DOI: 10.1021/Acs.Analchem.6B03727  0.832
2017 Garcia L, Saba C, Manocchio G, Anderson GA, Davis E, Clowers BH. An open source ion gate pulser for ion mobility spectrometry International Journal For Ion Mobility Spectrometry. 20: 87-93. DOI: 10.1007/s12127-017-0223-x  0.417
2016 Davis AL, Liu W, Siems WF, Clowers BH. Correlation ion mobility spectrometry. The Analyst. PMID 27965991 DOI: 10.1039/C6An02249A  0.807
2016 Morrison KA, Bendiak BK, Clowers BH. Enhanced Mixture Separations of Metal Adducted Tetrasaccharides Using Frequency Encoded Ion Mobility Separations and Tandem Mass Spectrometry. Journal of the American Society For Mass Spectrometry. PMID 27796835 DOI: 10.1007/S13361-016-1505-Y  0.759
2016 Craft RM, Haas AE, Wiley JL, Yu Z, Clowers BH. Gonadal hormone modulation of ∆(9)-tetrahydrocannabinol-induced antinociception and metabolism in female versus male rats. Pharmacology, Biochemistry, and Behavior. PMID 27670094 DOI: 10.1016/J.Pbb.2016.09.006  0.494
2016 Choy CJ, Ley CR, Davis AL, Backer BS, Geruntho JJ, Clowers BH, Berkman CE. Second-Generation of Tunable pH-Sensitive Phosphoramidate-Based Linkers for Controlled Release. Bioconjugate Chemistry. PMID 27562353 DOI: 10.1021/Acs.Bioconjchem.6B00422  0.715
2016 Morrison KA, Siems WF, Clowers BH. Augmenting Ion Trap Mass Spectrometers Using a Frequency Modulated Drift Tube Ion Mobility Spectrometer. Analytical Chemistry. 88: 3121-9. PMID 26854901 DOI: 10.1021/Acs.Analchem.5B04223  0.774
2016 Morrison KA, Siems WF, Clowers BH. Augmenting Ion Trap Mass Spectrometers Using a Frequency Modulated Drift Tube Ion Mobility Spectrometer Analytical Chemistry. 88: 3121-3129. DOI: 10.1021/acs.analchem.5b04223  0.774
2015 Clowers BH, Siems WF, Yu Z, Davis AL. A two-phase approach to fourier transform ion mobility time-of-flight mass spectrometry. The Analyst. 140: 6862-70. PMID 26275009 DOI: 10.1039/c5an00941c  0.815
2014 Prost SA, Crowell KL, Baker ES, Ibrahim YM, Clowers BH, Monroe ME, Anderson GA, Smith RD, Payne SH. Detecting and removing data artifacts in Hadamard transform ion mobility-mass spectrometry measurements. Journal of the American Society For Mass Spectrometry. 25: 2020-7. PMID 24796262 DOI: 10.1007/S13361-014-0895-Y  0.673
2013 Ewing RG, Clowers BH, Atkinson DA. Direct real-time detection of vapors from explosive compounds. Analytical Chemistry. 85: 10977-83. PMID 24090362 DOI: 10.1021/ac402513r  0.399
2013 Ewing RG, Atkinson DA, Clowers BH. Direct real-time detection of RDX vapors under ambient conditions. Analytical Chemistry. 85: 389-97. PMID 23215531 DOI: 10.1021/ac302828g  0.348
2011 Froehlich JW, Barboza M, Chu C, Lerno LA, Clowers BH, Zivkovic AM, German JB, Lebrilla CB. Nano-LC-MS/MS of glycopeptides produced by nonspecific proteolysis enables rapid and extensive site-specific glycosylation determination. Analytical Chemistry. 83: 5541-7. PMID 21661761 DOI: 10.1021/Ac2003888  0.798
2011 Davis EJ, Clowers BH, Siems WF, Hill HH. Comprehensive software suite for the operation, maintenance, and evaluation of an ion mobility spectrometer International Journal For Ion Mobility Spectrometry. 14: 117-124. DOI: 10.1007/s12127-011-0068-7  0.527
2010 Shah AR, Davidson J, Monroe ME, Mayampurath AM, Danielson WF, Shi Y, Robinson AC, Clowers BH, Belov ME, Anderson GA, Smith RD. An efficient data format for mass spectrometry-based proteomics. Journal of the American Society For Mass Spectrometry. 21: 1784-8. PMID 20674389 DOI: 10.1016/J.Jasms.2010.06.014  0.387
2010 Fraga CG, Clowers BH, Moore RJ, Zink EM. Signature-discovery approach for sample matching of a nerve-agent precursor using liquid chromatography-mass spectrometry, XCMS, and chemometrics. Analytical Chemistry. 82: 4165-73. PMID 20405949 DOI: 10.1021/Ac1003568  0.304
2009 Zhu M, Bendiak B, Clowers B, Hill HH. Ion mobility-mass spectrometry analysis of isomeric carbohydrate precursor ions. Analytical and Bioanalytical Chemistry. 394: 1853-67. PMID 19562326 DOI: 10.1007/S00216-009-2865-Y  0.71
2009 Tolmachev AV, Clowers BH, Belov ME, Smith RD. Coulombic effects in ion mobility spectrometry. Analytical Chemistry. 81: 4778-87. PMID 19438247 DOI: 10.1021/Ac900329X  0.565
2009 Chu CS, Niñonuevo MR, Clowers BH, Perkins PD, An HJ, Yin H, Killeen K, Miyamoto S, Grimm R, Lebrilla CB. Profile of native N-linked glycan structures from human serum using high performance liquid chromatography on a microfluidic chip and time-of-flight mass spectrometry. Proteomics. 9: 1939-51. PMID 19288519 DOI: 10.1002/Pmic.200800249  0.724
2009 Dodds ED, Seipert RR, Clowers BH, German JB, Lebrilla CB. Analytical performance of immobilized pronase for glycopeptide footprinting and implications for surpassing reductionist glycoproteomics Journal of Proteome Research. 8: 502-512. PMID 19072223 DOI: 10.1021/Pr800708H  0.766
2008 López-Ferrer D, Petritis K, Lourette NM, Clowers B, Hixson KK, Heibeck T, Prior DC, Pasa-Tolić L, Camp DG, Belov ME, Smith RD. On-line digestion system for protein characterization and proteome analysis. Analytical Chemistry. 80: 8930-6. PMID 19551971 DOI: 10.1021/Ac800927V  0.525
2008 Clowers BH, Dodds ED, Seipert RR, Lebrilla CB. Dual polarity accurate mass calibration for electrospray ionization and matrix-assisted laser desorption/ionization mass spectrometry using maltooligosaccharides Analytical Biochemistry. 381: 205-213. PMID 18655765 DOI: 10.1016/J.Ab.2008.06.041  0.821
2008 Belov ME, Clowers BH, Prior DC, Danielson WF, Liyu AV, Petritis BO, Smith RD. Dynamically multiplexed ion mobility time-of-flight mass spectrometry. Analytical Chemistry. 80: 5873-83. PMID 18582088 DOI: 10.1021/Ac8003665  0.559
2008 Seipert RR, Dodds ED, Clowers BH, Beecroft SM, German JB, Lebrilla CB. Factors that influence fragmentation behavior of N-linked glycopeptide ions Analytical Chemistry. 80: 3684-3692. PMID 18363335 DOI: 10.1021/Ac800067Y  0.83
2008 Clowers BH, Belov ME, Prior DC, Danielson WF, Ibrahim Y, Smith RD. Pseudorandom sequence modifications for ion mobility orthogonal time-of-flight mass spectrometry. Analytical Chemistry. 80: 2464-73. PMID 18311942 DOI: 10.1021/Ac7022712  0.547
2008 Clowers BH, Ibrahim YM, Prior DC, Danielson WF, Belov ME, Smith RD. Enhanced ion utilization efficiency using an electrodynamic ion funnel trap as an injection mechanism for ion mobility spectrometry. Analytical Chemistry. 80: 612-23. PMID 18166021 DOI: 10.1021/Ac701648P  0.531
2008 Dodds ED, Clowers BH, Hagerman PJ, Lebrilla CB. Systematic characterization of high mass accuracy influence on false discovery and probability scoring in peptide mass fingerprinting Analytical Biochemistry. 372: 156-166. PMID 17980142 DOI: 10.1016/J.Ab.2007.10.009  0.522
2007 Clowers BH, Dodds ED, Seipert RR, Lebrilla CB. Site determination of protein glycosylation based on digestion with immobilized nonspecific proteases and fourier transform ion cyclotron resonance mass spectrometry Journal of Proteome Research. 6: 4032-4040. PMID 17824634 DOI: 10.1021/Pr070317Z  0.819
2007 Dwivedi P, Bendiak B, Clowers BH, Hill HH. Rapid resolution of carbohydrate isomers by electrospray ionization ambient pressure ion mobility spectrometry-time-of-flight mass spectrometry (ESI-APIMS-TOFMS). Journal of the American Society For Mass Spectrometry. 18: 1163-75. PMID 17532226 DOI: 10.1016/j.jasms.2007.04.007  0.662
2007 Baker ES, Clowers BH, Li F, Tang K, Tolmachev AV, Prior DC, Belov ME, Smith RD. Ion mobility spectrometry-mass spectrometry performance using electrodynamic ion funnels and elevated drift gas pressures. Journal of the American Society For Mass Spectrometry. 18: 1176-87. PMID 17512752 DOI: 10.1016/J.Jasms.2007.03.031  0.724
2007 Kirmiz C, Li B, An HJ, Clowers BH, Chew HK, Lam KS, Ferrige A, Alecio R, Borowsky AD, Sulaimon S, Lebrilla CB, Miyamoto S. A serum glycomics approach to breast cancer biomarkers. Molecular & Cellular Proteomics : McP. 6: 43-55. PMID 16847285 DOI: 10.1074/Mcp.M600171-Mcp200  0.733
2007 Chavarría-Miranda D, Clowers B, Anderson G, Belov M. Simulating data processing for an advanced Ion Mobility mass spectrometer Proceedings - 1st International Workshop On High-Performance Reconfigurable Computing Technology and Applications, Hprcta'07, Held in Conjunction With Sc07. 21-29. DOI: 10.1145/1328554.1328563  0.412
2006 Dwivedi P, Wu C, Matz LM, Clowers BH, Siems WF, Hill HH. Gas-phase chiral separations by ion mobility spectrometry. Analytical Chemistry. 78: 8200-6. PMID 17165808 DOI: 10.1021/ac0608772  0.562
2006 Ninonuevo MR, Park Y, Yin H, Zhang J, Ward RE, Clowers BH, German JB, Freeman SL, Killeen K, Grimm R, Lebrilla CB. A strategy for annotating the human milk glycome. Journal of Agricultural and Food Chemistry. 54: 7471-80. PMID 17002410 DOI: 10.1021/Jf0615810  0.568
2006 Clowers BH, Hill HH. Influence of cation adduction on the separation characteristics of flavonoid diglycoside isomers using dual gate-ion mobility-quadrupole ion trap mass spectrometry. Journal of Mass Spectrometry : Jms. 41: 339-51. PMID 16498610 DOI: 10.1002/jms.994  0.642
2006 Clowers BH, Siems WF, Hill HH, Massick SM. Hadamard transform ion mobility spectrometry. Analytical Chemistry. 78: 44-51. PMID 16383309 DOI: 10.1021/ac050615k  0.609
2005 Clowers BH, Hill HH. Mass analysis of mobility-selected ion populations using dual gate, ion mobility, quadrupole ion trap mass spectrometry. Analytical Chemistry. 77: 5877-85. PMID 16159117 DOI: 10.1021/ac050700s  0.659
2005 Steiner WE, Klopsch SJ, English WA, Clowers BH, Hill HH. Detection of a chemical warfare agent simulant in various aerosol matrixes by ion mobility time-of-flight mass spectrometry. Analytical Chemistry. 77: 4792-9. PMID 16053290 DOI: 10.1021/ac050278f  0.602
2005 Clowers BH, Dwivedi P, Steiner WE, Hill HH, Bendiak B. Separation of sodiated isobaric disaccharides and trisaccharides using electrospray ionization-atmospheric pressure ion mobility-time of flight mass spectrometry. Journal of the American Society For Mass Spectrometry. 16: 660-9. PMID 15862767 DOI: 10.1016/j.jasms.2005.01.010  0.656
2004 Steiner WE, Clowers BH, English WA, Hill HH. Atmospheric pressure matrix-assisted laser desorption/ionization with analysis by ion mobility time-of-flight mass spectrometry. Rapid Communications in Mass Spectrometry : Rcm. 18: 882-8. PMID 15095357 DOI: 10.1002/rcm.1419  0.614
2003 Steiner WE, Clowers BH, Haigh PE, Hill HH. Secondary ionization of chemical warfare agent simulants: atmospheric pressure ion mobility time-of-flight mass spectrometry. Analytical Chemistry. 75: 6068-76. PMID 14615983 DOI: 10.1021/ac034349r  0.618
2003 Steiner WE, Clowers BH, Hill HH. Rapid separation of phenylthiohydantoin amino acids: ambient pressure ion-mobility mass spectrometry (IMMS). Analytical and Bioanalytical Chemistry. 375: 99-102. PMID 12520443 DOI: 10.1007/s00216-002-1622-2  0.515
2002 Steiner WE, Clowers BH, Matz LM, Siems WF, Hill HH. Rapid screening of aqueous chemical warfare agent degradation products: ambient pressure ion mobility mass spectrometry. Analytical Chemistry. 74: 4343-52. PMID 12236341 DOI: 10.1021/ac025687f  0.556
2002 Matz LM, Steiner WE, Clowers BH, Hill HH. Evaluation of micro-electrospray ionization with ion mobility spectrometry/mass spectrometry International Journal of Mass Spectrometry. 213: 191-202. DOI: 10.1016/S1387-3806(01)00534-6  0.573
2002 Steiner WE, Clowers BH, Matz LM, Siems WF, Hill HH. Rapid screening of aqueous chemical warfare agent degradation products: Ambient pressure ion mobility mass spectrometry (IMMS) Proceedings 50th Asms Conference On Mass Spectrometry and Allied Topics. 861-862.  0.605
2001 Steiner WE, Clowers BH, Fuhrer K, Gonin M, Matz LM, Siems WF, Schultz AJ, Hill HH. Electrospray ionization with ambient pressure ion mobility separation and mass analysis by orthogonal time-of-flight mass spectrometry. Rapid Communications in Mass Spectrometry : Rcm. 15: 2221-6. PMID 11746889 DOI: 10.1002/rcm.495  0.631
2001 Matz LM, Clowers BH, Steiner WE, Siems WF, Hill HH. Liquid-Sheath-Flow Electrospray Ionization Feasibility Study of Direct Water Analysis with the Use of High-Resolution Ion-Mobility Spectrometry Field Analytical Chemistry and Technology. 5: 91-96. DOI: 10.1002/fact.1009  0.532
2001 Clowers BH, Steiner WE, Dion HM, Matz LM, Tam M, Tarver EE, Hill HH. Evaluation of Sulfonylurea Herbicides Using High Resolution Electrospray Ionization Ion Mobility Quadrupole Mass Spectrometry Field Analytical Chemistry and Technology. 5: 302-312. DOI: 10.1002/Fact.10010  0.617
Show low-probability matches.